Loading...
HomeMy WebLinkAboutT-270308e TIB N0. 8- 1- 102(29) Q GENERAL NOTES• LEGEND 0 1. THESE GENERAL NOTES APPLY TO ALL "TS" PREFIX DRAWINGS. e - EXISTING PROPOSED PROPOSED W~ �"�' As, 2. ALL MATERIALS AND CONSTRUCTION SHALL CONFORM TO CITY OF ® m TYPE 1 JUNCTION BOX ��.,rnu c AN-D 01.wc_ ARID SPECIFICATIONS n SIGNAL POLE NUMBER w $ a � '� %l i�Lii i UIr J i rvrvrU.0 SPECIFICATIONS. _.+, .. -...,. ys �j V�Q9 0 O TYPE 2 JUNCTION BOX 3. FOR POLE FOUNDATIONS, REFER TO DRAWING TSD -1; ALL NE'r'! �4 CnNSTRUCTION NOTE FOUNDATION LOCATIONS IN THE FIELD 'SHALL BE APPROVED IU Is TYPE 3 JUNCTION BOX BY THE ENGINEER' PRIOR TO EXCAVATION. —fl —10- VEHICLE SIGNAL HEAD Q WIRING NOTE w »P - 4. ALL LOOPS, UNLESS OTHERWISE NOTED, SHALL BE 6 FOOT BY 6 FOOT PEDESTRIAN SIGNAL HEAD ti' �A QGen WITH 3 TURNS OF WIRE. SPLICE LOOP' TO LEADING 'CABLE IN JUNCTION BOX. T MASTARM SIGN Q �� OO \` 43 EMERGENCY PRE - EMPTION DETECTOR 5. CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN (TCP) TO THE ® ® CONTROLLER CABINET ENGINEER FOR APPROVAL PRIOR TO DISCONNECT OF EXISTING TRAFFIC ® ® ELECTRICAL SERVICE CABINET � o �� SIGNAL SYSTEM. ALL TCP SHALL CONFORM TO THE MUTCD AND CITY OF ® 0 rr� Q 0 v\ RENTON STANDARD SPECIFICATIONS AND REQUIREMENTS. POWER TRANSFORMER ! —I Q L:' \� 6. ALL SIGNAL POLES SHALL HAVE A MOUNTED TERMINAL CABINET. w O <Z \ �� �� PEDESTRIAN PUSHBUTTON I- \ C� 7. THE LOCATION OF CONDUITS AND JUNCTION BOXES SHOWN ON THESE z _J IS `\ 9 `\ PLANS ARE FOR PRESENTATION ONLY JUNCTION BOX LOCATIONS ARE O�� SIGNAL POLE (TYPE 2) j to Q ': `. \ �� �� SUBJECT "TO - APPROVAL OF ENGINEER WITH TERMINAL CABINET Q � 0 Cn SIGNAL POLE (TYPE 3 ) s Z Q \ e WITH TERMINAL CABINET N Q W = ° e PRE- EM PTION CONDUIT SCHED ULE d 0 Z '" \\\�s ` \�\ lee` _ I TYPE 2 INDUCTION LOOP CIRACUIT m �. �� J (6' `\ �e� 4 7 B 03 & 08 C k71 & 06 M 7 9 1 1 FOR WIRING DIAGRAM NOTES= \ \ b D 03 & 08 IGNAt POLE SCHEDULE SEE DRAWING TSD -1 SEE DRAWING TS -16. v.. CHE R o � � -, �• ,e ,,, c O O o f 2 e` 3 SEE DRAWINGS CH -1 THRU CH -4 FOR INTERCONNECT. 3 e i HMO O■��I_ =_ MM 2" SPARE 2" SPARE 2 v a `w �, NOTE: ALL 'CONDUIT SHALL BE PVC. H o . o •.� \ ..�. 4. SEE DRAWINGS GH 1 `THR GH -4 FOR ILLt1MINALION AND ,SIGNING.. PL ... _ ;i� * TWISTED' PAIR I 2 p O 22 O C 3 z N g 5 � 10 .. ¢ oN 703 8 li :5TH 500+00.0.0= 8 o 0 20 : 40 60 4.,. MAIN 20 +00 N d 8 120-00:010 Lo \` 1 Scale In Feet 5 F yY- - •;: � R-. - _.� « "�,. a 620-00.00= m _ 6 MAIN 20 ,l 4.57 RN OD ,21 ®tt o i� ` 22 A` _ - - - - - -- - W -o. zz. ic « ----- - -__.. _ _,.� ._. .. .. .._ -.. BENSON RD > _ x I 6.16,00. N1 02 E Ni +OO 617...0.. - 618100 o 00 8 0 / W o o _ - 00 MAIN AVE - --- g -o- s 2 - - - - -- ------------------ - - - - -- - 619 1 4 7 82 cn In 00 a 0)0000 00 W ro o °' rn °' 4 3 00 Lo PROVIDE AND INSTALL TYPE 3 SIGNAL STANDARD WITH A 13.5 FOOT MASTARM. INSTALL SINGLE r x x °' co S O TYPE III -40OW LUMINAIRE' WITH , FULL CUT -OFF LENS ON A 12 FOOT LUMINNRE ARM. INSTALL w 3:0 > SIGNAL HEAD DISPLAY f / SIGNAL DISPLAYS 81 AND 82 AND AN EMERGENCY VEHICLE PRE -EMPT DETECTOR. m v w < m °i CONSTRUCT FOUNDATION FLUSH WITH WALL. SEE DETAIL ON DRAWING TSD -2. SIGNAL PHASE DIAGRAM �\ C 6 PROVIDE AND INSTALL TYPE PS PEDESTRIAN POLE. INSTALL PEDESTRIAN Q O 12" ® 12' CONSTRUCTION NOTES PUSHBUTTON AND PEDESTRIAN SIGNAL DISPLAY 48. OA 12" O 12" 131 r- BLANK 05 O1 REMOVE EXISTING SIGNAL POLE, SIGNAL DISPLAYS AND ASSOCIATED WIRES. PROVIDE AND INSTALL TYPE PS PEDESTRIAN POLE. INSTALL PEDESTRIAN SALVAGE ALL SIGNAL EQUIPMENT TO THE CITY OF RENTON, PUSHBUTTON AND PEDESTRIAN SIGNAL DISPLAY 49. REFER TO G 12" -G 12" 2 REMOVE EXISTING SIGNAL CONTROLLER, ELECTRICAL SERVICE CABINET AND ASSOCIATED ® F LLYYLACTTUATEODLTRAFFIIBC SIGNALDCON ROLLER ,AND ASSOCIAT D EQUPMENT. DRAWINGAFOR co O O 02 �- 6 O WIRES. SALVAGE ALL SIGNAL EQUIPMENT TO THE CITY OF RENTON. COORDINATE ELECTRICAL z z FOUNDATION LOCATION SHALL BE APPROVED BY THE ENGINEER PRIOR TO SIGNATURES 0 SERVICE REMOVAL WITH THE CITY OF RENTON. SPLICE EXISTING ILLUMINATION CIRCUIT TO VEHICLE SIGNAL VEHICLE SIGNAL PEDESTRIAN SIGNAL NEW SERVICE. SEE ILLUMINATION PLANS CH -1 THRU CH -4. EXCAVATION. AND SEALS z °w HEADS HEADS HEADS 03 BLANK 07 PROVIDE AND INSTALL TYPE SDI SIGNAL STANDARD WITH ONE 45 FOOT MASTARM g INSTALL 120/240V MOD. TYPE B ELECTRICAL SERVICE AND CABINET. COORDINATE WITH Ei 11, 12, 31, 32 48,49 3Q 0 :PUGET SOUND ENERGY (PSE) TO RELOCATE EXISTING POWER TO NEW SERVICE LOCATIONS. ate? 21, 22, 61, AND ONE 40 FOOT MASTARM. INSTALL SINGLE TYPE' III -40OW 'LUMINAIRE WITH FULL Z °z a 62, 81, 82 0 -� �$ CUT -OFF LENS ON A SIX FOOT LUMINAIRE ARM. INSTALL SIGNAL DISPLAYS 11, 12: 61 B a ANDr62 AND AN EMERGENCY VEHICLE PRE -EMPT DETECTOR ON THE 45'FOOT MASTARM 10 ,REMOVE EXISTING JUNCTION OX AND ABANDON ALL CONDUITS TO 18 INCHES BELOW GRADE. CD i 'o �� !a N' AND SIGNAL DISPLAYS 31 AND 32 AND AN EMERGENCY VEHICLE PRE -EMPT DETECTOR ON v 1. ALL VEHICLE HEADS SHALL BE! 12" WITH TUNNEL VISORS, d !i °ww o --s VEHICLE PROTECTED MOVEMENT THE 40 FOOT'' MASTARM! o U INSTALLED WITH TYPE M MOUNTS; o » L:cm> rno �-.� PEDESTRIAN PHASE o w _ PROVIDE AND INSTALL TYPE 3': SIGNAL STANDARD WITH A 30 FOOT MASTARM. INSTALL SINGLE r 2. ALL PEDESTRIAN! HEADS SHALL' BE FIBER OPTIC WITH TYPE E OLA - ,01, 04 AND 08 L CUT -OFF LENS' ON A 12 FOOT' LUMINAIRE ARM. INSTALL TYPE' III -40OW LUMINAIRE .WITH FUL SIGNAL PLAN W MOUNTS. PEDESTRIAN PUSH BUT TONS AND SIGNS SHALL AND 22 AND AN EMERGENCY VEHICLE''PRE -EMPT DETECTOR: CONFORM TO CITY OF RENTON STANDARD ,PLAN J024 AND J0251 SIGNAL DISPLAYS 21, rRo - -�7at i MAIN AVE S. & GRAD WAY S. '�"'ss of 45 AG ; T- 7-13'<fi 'CANNED FEQ 1 7nn2 I ....... ....... I FR 1: 7