OAKESDALE AVENUE S ,' EXTENSION -PHASE 18 & 2 DWG NO.
E3
ILLUMINATION AND SHEET
SCALE IN FEET
INTERCONNECT PLAN 46 OF 69
_
20 10 0 20 40
HORIZ.
GENERAL ILLUMINATION NOTES
SCHEDULE
ILLUMINATION CONSTRUCTION NOTES
1. CONSTRUCT CONCRETE PAD FOR PROPOSED STREET LIGHTING I
CONDUCTORS
1. FURNISH AND INSTALL ONE COBRA HEAD LUMINARE WITH POWER
AND JUNCTION BOX PER CITY OF RENTON STANDARD PLAN
2 — #6, 1 — #8 GROUND
DOOR AND MEDIUM TYPE III CUTOFF OPTICS, 400 WATT HIGH
J014 AND J015.
PRESSURE SODIUM LAMP, AND FIXED BASE TYPE. MOUNTING
HEIGHT AND ARM LENGTH SHALL BE AS SHOWN IN ILLUMINATION
2• ALL PROPOSED ILLUMINATION CONDUIT RUNS (TRENCH) SHALL BE
SCHEDULE. CONSTRUCT FOUNDATION PER WSDOT STD. PLAN J —lb
LOCATED 6' FROM BACKOF CURB EXCEPT AT WALL.
AND THE SCHEDULE BELOW. FOUNDATION DEPTH SHALL BE AS
INDICATED IN THE ILLUMINATION SCHEDULE. INSTALL TYPE 1
3. REFER TO SIGNAL PLAN FOR ILLUMINATION CONDUIT
JUNCTION BOX ADJACENT TO LUMINAIRE PER CITY OF RENTON
AT SIGNALIZED INTERSECTION.
STANDARD PLAN J008.
4. CONSTRUCT LIGHTING UNDERGROUND SYSTEM PER CITY
4. INSTALL TYPE I JUNCTION BOX PER CITY OF
OF RENTON STANDARD PLAN J007.
RENTON STANDARD PLAN J008 AND J016.
5. ALL LUMINAIRE POLE BASES "P-MOVED SHALL BECOME FHE
PROPERTY OF THE CONTRACTOR. ALL OTHER UTILITY ITEMS
REMOVED SHALL BECOME THE PROPERTY OF THE CITY (EXCEPT
WHEN WORK IS DONE BY OTHERS) AND SHALL BE SALVAGED
IN ACCORDANCE WITH THE SPECIFICATIONS.
rQ ®_v' -a7r7
CONDUIT AND WIRING
SCHEDULE
RUN
NO.
CONDUIT
CONDUCTORS
1
2" PVC SCH 40
2 — #6, 1 — #8 GROUND
2+
2" PVC SCH 40
PULL WIRE
ROLL # 167
*FOR FUTURE INTERCONNECT USE
NOTE
E~
Qi
vn
THE EXISTING TOPOGRAPHIC AND PHYSICAL FEATURES SHOWN ON THESE PLANS
ARE BASED ON:
INFORMATION PROVIDED BY W &H PACIFIC SURVEY 1997
THIS WAS THE INFORMATION AVAILABLE AT THE TIME OF PLAN PREPARATION.
ACTUAL CONDITIONS MAY BE DIFFERENT. THE CONTRACTOR MAY ENCOUNTER
VARIATIONS BETWEEN ACTUAL CONDITIONS AND THOSE SHOWN. THESE VARIATIONS
WILL NOT BE THE BASIS FOR A CLAIM OR EXTRA COMPENSATION.
THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE
WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ENTRANCO.
THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES
BEFORE COMMENCING WORK, AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL
DAMAGES WHICH MIGHT BE OCCASIONED BY THE CONTRACTOR'S FAILURE TO EXACTLY
LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.