HomeMy WebLinkAboutT-276102SEE CITY OF RENTON SPECIAL PROVISIONS
FOR BOLT SPECIFICATION. LENGTH OF BOLT
MAY BE SHORTENED IF IT MEETS MANUFACTURERS
RECOMMENDED LENGTH.
I
18" MIN.
CLASS 3000 CONCRETE 4' -6"
8 #7 BARS
EVENLY SPACED
#4 HOOPS I
12" CENTERS — — — —
2" CLEARANCE
3' SQ OR RND
FOUNDATION DETAIL 3 ��
`I� 3
vl i
I�
II
I
I�
Im
z
3
I
o
r
_m
X
W
I
I
CONSTRUCTION NOTES
10 CONSTRUCT SERVICE /ILLUMINATION CABINET FOUNDTION. INSTALL SERVICE /ILLUMINATION
CAB I N ET.
20 CONSTRUCT LUMINAIRE POLE FOUNDATION WI1H CONCRETE PAD AND TYPE 1 JUNCTION BOX
(SEE DETAIL, SHEET 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS
LUMINAIRE.
3O CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 2 JUNCTION BOX
(SEE DETAIL, SHEET 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HIPS
LUMINAIRE.
® INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD (SEE DETAIL, SHEET 4).
5� CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH PUGET SOUND ENERGY REQUIREMENTS.
M-
LUMINAIRE SCHEDULE
LUMINAIRE
NO.
CITY OF RENTON
LUMINAIRE I.D.
NUMBER (l)
LAMP
WATTAGE
POLE
LOCATION
CL OF POLE
CURBFACE
MOUNTING
HEIGHT
CIRCUIT
NO.
REMARKS
1
21 168
100 WATT
0 +56 RT
6 FT.
25 FT.
1
TYPE III LIGHT DISTRIBUTION
2
2118B
100 WATT
2 +03 RT
6 FT.
25 FT,
1
TYPE III LIGHT DISTRIBUTION
A 441
PULL STRING
2" PVC
(FUTURE LIGHTING)
(1) NUMBER TO BE AFFIXED TO POLE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAIL.
SERVICE CABINET (I.D. NO. 0021)
BREAKER AND CONTACTOR SCHEDULE
CIRCUIT
NO.
MAIN BREAKER
AMPS
BRANCH BREAKER
AMPS
CONTACTOR
AMPS
REMARKS
MAIN
100
–
–
120/240 VOLT
1 ILLUM
–
20
30
240 VOLT
TYPE 1 JUNCTION BOX
1 GREEN NO. 8 (GND)
CONDUIT
A3
2 NO. 10 (ILLUM)
1 - -1/2" PVC
WIRE NOTE
GREEN NO. 8 (GND)
A 441
Ci-): 7-- 276102
G l Gz"4
F�,
WIRE NOTES
RUN
CONDUCTORS
CONDUIT
VIN
LIGHTING CONTACTOR CABINET
A3
NO. 2 (POWER)
2" PVC
AND TYPE 1 JUNCTION BOX
1 GREEN NO. 8 (GND)
COMBINATION FOUNDATION WITH LUMINAIRE
A2
2 NO. 10 (ILLUM)
2" PVC
TYPE 1 JUNCTION BOX
1 GREEN NO. 8 (GND)
CONDUIT
A3
2 NO. 10 (ILLUM)
1 - -1/2" PVC
WIRE NOTE
GREEN NO. 8 (GND)
A 441
PULL STRING
2" PVC
(FUTURE LIGHTING)
NOTE: LATERAL CONDUITS SHALL BE PVC SCH. 40.
STREET CROSSINGS SHALL BE PVC SCH. 80.
G9 0.
��J
LEGEND
VIN
LIGHTING CONTACTOR CABINET
COMBINATION FOUNDATION WITH LUMINAIRE
AND TYPE 1 JUNCTION BOX
COMBINATION FOUNDATION WITH LUMINAIRE
AND TYPE 2 JUNCTION BOX
®
TYPE 1 JUNCTION BOX
CONDUIT
O
CONSTRUCTION NOTE
WIRE NOTE
G9 0.
��J