HomeMy WebLinkAboutT-276103I_ SEE CITY OF RENTON SPECIAL PROVISIONS FOR BOLT SPECIFICATION. LENGTH OF BOLT MAY BE SHORTENED IF IT MEETS MANUFACTURERS RECOMMENDED LENGTH. I— I � —1 18" MIN. � I j I I I�� I I �J'_I CLASS 3000 CONCRETE I I � 4' -6" 8 �7 BARS I I I EVENLY SPACED I I #4 HOOPS I I I I 12" CENTERS — — — � –� 2 "CLEARANCE 3' SQ OR RND FOUNDATION DETAIL � I o N � I� `� 3 I M rr�� �1 � f i I3 IZ 3 i o v ro _� X W I CONSTRUCTION NOTES 0 CONSTRUCT SERVICE /ILLUMINATION CABINET FOUNDTION. INSTALL SERVICE /ILLUMINATION CABINET. O2 CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX (SEE DETAIL, SHEET 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS LUMINAIRE. O3 CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 2 JUNCTION. BOX (SEE DETAIL, SHEET 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS LUMINAIRE. ® INS�ALLTYPE 1 JUNCTION BOX WITH CONCRETE PAC (SEE DETAIL, SHEET 4). 5� CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH PUGET SOUND ENERGY REQUIREMENTS, r�Ao- ai -�'sr LUMINAIRE SCHEDULE LUMINAIRE N0. CITY OF RENTON LUMINAIR I.D. NUMBER 1 LAMP WATTAGE POLE LOCATION CL OF POLE CURBFACE MOUNTING HEIGHT CIRCUIT N0. REMARKS 1 21166 100 WATT 0 +56 RT 6 FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 2 21 186 100 WATT 2 +03 RT 6 FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION (1) NUMBER TO BE AFFIXED TO POLE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAlL. ROLL 161 SERVICE CABINET (I.D. R0. 00� BREP:KF_R AND CONTACTOR SCHEDULE CIRCUIT N0. MAIN BREAKER AMPS BRANCH BREAKER AMPS COPJTACTOR AMPS REMARKS MAIN 100 – – 120 240 VOLT 1 ILEUM – 20 30 240 VOLT 2 N0. 10 (ILEUM) 1 GREEN N0. 8 (GND) 1 -1 /2" PVC WIRE NOTES �4 PULL STRING (FUTURE LIGHTING} 2" PVC RUN CONDUCTORS CONDUIT FINdL CORREG ?ED PLAN _.RD !Z iHiS DRAWING rix- �?E�iV PREPARED -1, BASED ON fNFlNiFhti °,� *, ^OMPILED �G�;•'.. _ FROM rHE COQ ,� �7R AND -` - ,� OTHERS ev /7`1,x' � 1 `�. rA!>Q ,n7F //— /1_-99_ �:.,�riHES. iQVOO ///i2/49 2 N0. 10 (ILEUM) 1 GREEN N0. 8 (GND) 1 -1 /2" PVC WIRE NOTES RUN CONDUCTORS CONDUIT 3 N0. 2 (POWER) 1 GREEN N0. 8 (GND) 2" PVC 2 N0. 10 (ILEUM} 1 GREEN N0. 8 (GND) 2" PVC 2 N0. 10 (ILEUM) 1 GREEN N0. 8 (GND) 1 -1 /2" PVC �4 PULL STRING (FUTURE LIGHTING} 2" PVC NOTE: LATERAL CONDUITS SHALL BE PVC SCH. 40. STREET CROSSINGS SHALL BE PVC SCH. 80. ��_ �� �� � � s LEGEND ® LIGHTING CE3NTACTOR CABINET �� --�'S- COMBINATION FOUNDATION WITH LUMINAIRE � ,y�.(� AND TYPE 1 JUNCTION SOX C����--1J CONI611VAlIVIV FGUiJ DATiON LVITH ! UMINAIRE AND TYPE 2 JUNCTION BOX ® TYPE 1 JUNCTION BOX - - - - - -- CONDUIT O CONSTRUCTION NOTE WIRE NOTE CO, T— z7� /oz �8-t': T— �..2�6/a3 :Cd►r1NED DEC 10199 q� /os