Loading...
HomeMy WebLinkAboutT-277604Q 1= Z 4 .a CONSTRUCTION NOTES 1O CONS FRUCT SERVICE /ILLUMINATION CABINET FOUNDTICN. INSTALL SERVICE /ILLUMINATION CABINET WITH METER BASE (SEE DETAIL SHEET 5). O CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX (SEE DETAIL, SHEET 4 ) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS LUMINAIRE (GE M -250A2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS). 0 CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX SEE DETAIL, SHEET 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS SEE (GE M -25OA2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS AND INTERNAL PEC). O4 INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD (SEE DETAIL, SHEET 4). O5 CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH P'JGET SOUND ENERGY REQUIREMENTS. mO 1° kI — :»i PROPOSED PSE VAULT. CONFIRM EXACT LOCATION AT TIME OF CONSTRUCTION. LUMINAIRE SCHEDULE LUMINAIRE NO. CITY OF RENTON LUMINAIRE I.D. NUMBER (l SEE CITY OF RENTON SPECIAL PROVISIONS C OF POLE MOUNTiNG CURBFACE HEIGHT CIRCUIT NO. REMARKS FOR BOLT SPECIFICATION. LENGTH OF BOLT 2567 1 D0 WATT 9 +91 RT -1 °&FT. 25 FT. MAY BE SHORTENED IF IT MEETS MANUFACTURERS TYPE III LIGHT DISTRIBUTION 2 2566 RECOMMENDED LENGTH. ''IN. 1 TYPE III LIGHT DISTRIBUTION 3 2564 100 WATT 12+ T 5'f fo 25 FT. 18 TYPE III LIGHT DISTRIBUTION 4 2562 100 WATT 114+qgR 25 FT. 1 TYPE III LIGHT DISTRIBUTION 5 2560 100 WATT 15 +59 RT ,.MFT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 6 2558 100 WATT 17 +14 R FT. 25 FT. 1 TYPE II! LIGHT DISTRIBUTION 7 2556 100 WATT 18+DeoRT i 25 FT. 1 TYPE III LIGHT DISTRIBUTION CLASS 3000 CONCRETE -- fi ( 7 - 25 FT. 4' -6" TYPE III LIGHT DISTRIBUTION 8 #7 BARS I O' 40' 80' EVENLY SPACED _ #4HOOPS " I­ - -- J 12 CENTERS _� — — — 2" CLEARANCE 3' SO OR RND FOUNDATION DETAIL Q 1= Z 4 .a CONSTRUCTION NOTES 1O CONS FRUCT SERVICE /ILLUMINATION CABINET FOUNDTICN. INSTALL SERVICE /ILLUMINATION CABINET WITH METER BASE (SEE DETAIL SHEET 5). O CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX (SEE DETAIL, SHEET 4 ) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS LUMINAIRE (GE M -250A2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS). 0 CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX SEE DETAIL, SHEET 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS SEE (GE M -25OA2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS AND INTERNAL PEC). O4 INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD (SEE DETAIL, SHEET 4). O5 CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH P'JGET SOUND ENERGY REQUIREMENTS. mO 1° kI — :»i PROPOSED PSE VAULT. CONFIRM EXACT LOCATION AT TIME OF CONSTRUCTION. LUMINAIRE SCHEDULE LUMINAIRE NO. CITY OF RENTON LUMINAIRE I.D. NUMBER (l LAMP POLE WATTAGE LOCATION C OF POLE MOUNTiNG CURBFACE HEIGHT CIRCUIT NO. REMARKS 1 2567 1 D0 WATT 9 +91 RT -1 °&FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 2 2566 100 WATT -M.;-40 LT -7 X FT 25 FT. 1 TYPE III LIGHT DISTRIBUTION 3 2564 100 WATT 12+ T 5'f fo 25 FT. 1 TYPE III LIGHT DISTRIBUTION 4 2562 100 WATT 114+qgR 25 FT. 1 TYPE III LIGHT DISTRIBUTION 5 2560 100 WATT 15 +59 RT ,.MFT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 6 2558 100 WATT 17 +14 R FT. 25 FT. 1 TYPE II! LIGHT DISTRIBUTION 7 2556 100 WATT 18+DeoRT i 25 FT. 1 TYPE III LIGHT DISTRIBUTION 8 2554 100 WATT +.,-� RT 7 - 25 FT. 1 TYPE III LIGHT DISTRIBUTION I _ (1) NUMBER TO BE AFFIXED TO POLE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAIL. I AS - CONSTRUCTED LOCATION of LUMINAIRES Q LUMINAIRE NUMBER 1 POLE CENTERLINE OF POLE I LOCATION FROM CURBFACE 9+91 I 6.65' 2 11 +36 114' 3 12+43 9.9' 4 13 +89 I 9.9' 5 15 +48 ! 6.4' 6 17+03 7.1' 7 ! 18 +36 6.7' 8 20+43 9.7' BREAKER AND CONTACTOR SCHEDULE Roadway Illumination As- Donsttucted locations were deteranned from field survey by Triad Associates. S. 47" Street WIRE NOTES RUN CONDUCTORS CONDUIT I 1 3 NO. 2 (POWER) 1 GREEN NO. 8 (GND) 2" PVC A 4 NO. 10 (IILUM) 2" PVC AND TYPE 1 JUNCTION BOX 1 GREEN NO. 8 (GND) COMBINATION FOUNDATION WITH LUMINAIRE A3 Z4 5 ,� 3 NO. 14 (PEC) 2 NO. 10 (ILLUM) 1 GREEN N0. 8 (GND) 3 NO. 14 (PEC) 2NO. 10 (ILLUM) 1 GREEN NO. 8 (GND) 2NO. 10 (ILLUM) 1 GREEN N0. 8 (GND) 2" PVC 2" PVC 1 -1/2" PVC NOTE: LATERAL CONDUITS SHALL BE PVC SCH. 40. STREET CROSSINGS SHALL BE PVC SCH. 80. CIRCUIT NO LEGEND ® SERVICE VAULT (PSE) REMARKS LIGHTING CONTACTOR CABINET 100 COMBINATION FOUNDATION WITH LUMINAIRE - AND TYPE 1 JUNCTION BOX - COMBINATION FOUNDATION WITH LUMINAIRE 20 AND TYPE 2 JUNCTION BOX ® TYPE 1 JUNCTION BOX --- - - - - -- CONDUIT O CONSTRUCTION NOTE 0 WIRE NOTE SERVICE CABINET (I.D. NO. 0025) BREAKER AND CONTACTOR SCHEDULE Roadway Illumination CIRCUIT NO MAIN BREAKER AMPS BRANCH BREAKER AMPS CONTACTOR AMPS REMARKS MAIN 100 - - 120/240 VOLT 1 ILLUM - 20 30 240 VOLT LL s CITY OF RENTON �. DEPARTMENT OF' PUBLIC WORKS 9 Illumination Plan ROLL # 167 FR rwt REVISION /,�l3 T - 27 71 6-V SCANNED OCT 4 2000 T MEN > � r O 1 A �u =m ; o <r N J a � RECOMMENDED JT FOR APPROVAL BY • DATE -l3- BY DATE 3. L I'$ BY DATE / BY DATE BY DATE i_j LL s CITY OF RENTON �. DEPARTMENT OF' PUBLIC WORKS 9 Illumination Plan Roadway Illumination .Zoo, :......................... Plat of Talbot Rid e DESIGNED D. HAMtIN DATE August 1999 FILE NO FIELD BOOK_ PAOE- 13e oo DRAvm CHECKED D. IAMLIN SCALE 1 "'40' .I APPROVED O SHEET 2 CF 5 DATE /,�l3 T - 27 71 6-V SCANNED OCT 4 2000 T MEN > � r O 1 A �u =m ; o <r N J a � RECOMMENDED JT FOR APPROVAL BY • DATE -l3- BY DATE 3. L I'$ BY DATE / BY DATE BY DATE i_j LL s CITY OF RENTON �. DEPARTMENT OF' PUBLIC WORKS 9 Illumination Plan Roadway Illumination .Zoo, Plat of Talbot Rid e DESIGNED D. HAMtIN DATE August 1999 FILE NO FIELD BOOK_ PAOE- 13e oo DRAvm CHECKED D. IAMLIN SCALE 1 "'40' 0 APPROVED SHEET 2 CF 5 DATE /,�l3 T - 27 71 6-V SCANNED OCT 4 2000 T MEN > � r O 1 A �u =m ; o <r N J a �