HomeMy WebLinkAboutT-293304LUMINAIRE SCHEDULE
CITY OF RENTON
LUMINAIRE I.D.
NUMBER ( 1)
CABINET
I.D .
CIRCUIT LUMINAIRE LAMP
NO. N0. WAT AGE
POLE
LOCATION
OF POLE
O
CURBFACE
MOUNTING
HEIGHT
ARM
LENGTH
REMARKS
HARRINGTON AVE SE HARRINGTON CT SE GLENNWOOD CT SE SE 4TH ST
4513B
A
2 I 14 100 WATT
��
/..\
2 NO. 8 (ILLUM)
7 +55 LT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4515B
A
2 15 100 WATT!
A2
5 +88 LT
2" PVC
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4517B
A
2 I 16 1 100 WATT
4 +03 RT
2 NO. 8 CONDUCTORS TO BE REMOVED AND REPLACED,
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4519B
A
2 j 17 j 100 WATT
2 +50 RT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4520B
A
2 1 8 100 WATT
13 +21 RT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4522B
A
2 1 19 j 100 WATT
12+06 LT
7 FT,
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4524B
A
2 j 20 1 00 WATT
10+89 LT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4526B
A
2 1 21 1 00 WATT
9 +38 LT
7 FT.
25 FT,
8 FT.
TYPE III LIGHT DISTRIBUTION
(1) NUMBER TO BE AFFIXED TO POLE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAIL
(SEE SHEET 9)_
NOTE: ALL NEW LUMINAIRES TO BE CONNECTED TO EXISTING CIRCUIT IN CABINET "A" LOCATED IN
PLAT OF LA COLINA (SEE SHEET 3).
CONSTRUCTION NOTES
1O CONSTRUCT LUMINAIRE POLE FOUNDATION (SEE LUMINAIRE POLE SCHEDULE FOR LOCATION,
SEE SHEET 10 FOR FOUNDATION DETAIL). INSTALL LUMINAIRE POLE AND LUMINAIRE.
INSTALL TYPE 1 JUNCTION BOX AND CONCRETE PAD (SEE SHEETS 7 & 8). TYPICAL 8
PLACES,
O2 INSTALL TYPE 1 JUNCTION BOX (SEE WSDOT STD. PLAN J -11 0 & SHEET 10).
O3 CONNECT NEW CONDUCTORS TO EXISTING ILLUMINATION CONDUCTORS IN EXISTING JUNCTION
BOX.
O4 IDENTIFY AND REMOVE EXISTING CONDUCTORS SERVING LUMINAIRES A2 -1 AND A2 -2.
INSTALL NEW NO. 4 CONDUCTORS AND RE- CONNECT AS NECESSARY TO RESTORE CIRCUIT.
Me - *o,- iy►jJl
WIRE NOTES
RUN
CONDUCTORS
CONDUIT
COMMENTS
2 NO. 10 (ILLUM)
1 -1/2" PVC
TYPICAL 8 PLACES.
1 GREEN NO. 8 (GND)
��
/..\
2 NO. 8 (ILLUM)
2" PVC
1 2 \
1 GREEN NO. 8 (GND)
A2
NO. 8 (ILLUM)
2" PVC
EXISTING CONDUIT.
1 GREEN NO. 8 (GND)
A4
2 NO. 4
2" PVC
2 NO. 8 CONDUCTORS TO BE REMOVED AND REPLACED,
OTHER CONDUCTORS TO REMAIN.
A
1 -
2" PVC
FUTURE ILLUMINATION CONDUCTORS. LEAVE PULLSTRING.
NOTE: LATERAL CONDUITS SHALL BE PVC SCH. 40.
NEW STREET CROSSINGS SHALL BE PVC SCH 80.
1 7 ,I FIR
c- 7= =,Y ° "u SCANNED FEB 15 2002
y
ti
w
W