HomeMy WebLinkAboutT-295001J
H
I o �
�rn
Z
1$ \J,�� Cl-
W _0
\J
® W
W
GRAPHIC SCALE
I
( IN FEET )
1 inch = 40 ft
T
8
W
O
Z
o >I.
0
I I Z
PORTION OF THE NE 114 OF THE NW 114
SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
CITY OF RENTON, STATE OF WA. SHINGTON
I
CONSTRUCTION NOTES
�
6Z9 M „62,b0.00S
I
!61
2" PVC - SCH. 80
h
Z
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON
STANDARD SPECIRCA77ONS AND THESE PLANS
2 "' PVC - SCH. 40
1 - #8 GROUND
IL
21 THE LOCATIONS OF FEA7URES SHOWN ARE APPROXIMATE AND SHALL
2 - #8 T.H. W. CU.
BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY.
Q Q N
3 - #' 12T. H. W. ( PEC j
Z d
J. INSTALL ALL S7REETL/GH77NG MA1LRlALSSHOWN ON THE PLANS
EXCEPT AS NOTED. ALL MATERIALS SHALL BE NEW AND OF THE BEST
O a a
AVAILABLE GRADE OR QUALITY, EXCEPT AS NOTED.
F- N h
1 - #8 GROUND
200 WATTS
4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON
ic N
FOR M47ERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE.
5. ALL XVRK SHALL BE CONSISTANT W17H UMITY AGENCY REQUIREMENTS
a
THE CON7RACTOR SHALL CONTACT ALL PER77NENT U77LITY AGENCIES
FORTY EIGHT (48) HOURS BEFORE COMMENCING WYIRK, AND SHALL
sir
r
COORDINA7£ 7HE WORK WITH THE U77LI77ES THROUGHOUT THE PRO,ECT.
F -1 -1
6. THE CON7RACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO
-- 2/
EXIS77NG UTIL/P,ES THE CONTRACTOR SHALL N077FY THE AFFECTED
STA 1 +75 -36LT
U77LITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE
8'
7 THE CONTRACTOR SHALL N077FY 7HE CITY OF RENTON CON57RUC77ON
2281 B
ENGINEERING DIVISION AT 277 -5570 FOR INSPEC77ON PURPOSES
NE 10TH ST
TWENTY -FOUR (24) HOURS BEFORE COMMENCING WORK. NO WORK
SHALL BE COVERED UN77L IT HAS BEEN EXAMINED BY THE ENGINEER.
T
8
W
O
Z
o >I.
0
I I Z
PORTION OF THE NE 114 OF THE NW 114
SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M.
CITY OF RENTON, STATE OF WA. SHINGTON
I
RUN NO.
CONDUIT'
6Z9 M „62,b0.00S
LUMINAIRE
2" PVC - SCH. 80
o
STA 1+55 - 43 RT
2 "' PVC - SCH. 40
1 - #8 GROUND
IL
2275 E
2 - #8 T.H. W. CU.
DUVALL AVE. NE
3 - #' 12T. H. W. ( PEC j
3
3" PVC - SCH. 40
2 - #8 T.H.W. CU.
STA 4+54 -41 RT
40,
1 - #8 GROUND
200 WATTS
2" PVC - SCH. 80
1 - #8 GROUND
DUVALL AVE. NE
2 - #8 T.H. W. CU.
sir
r
-1 F
F -1 -1
r -
-- 2/
AS 26' LT (NE 10TH ST)
STA 1 +75 -36LT
25"
8'
100 WATTS
2281 B
NE 10TH ST
ST LIGHT #5
I II I I
I'I
ICI
lil
III
II Ili I I �_ _
I II
I
�
STA 2 +45 -22 RT
DUVALL CT NE
25"
8'
100 WATTS
2285 B
v
STA 4+4.5 -22'RT
DUVALL CT NE
25•
I
- - - - - -� l
2 2--
j,L - -
-- L- -
-- J L - -
I I ST 2--45 22
2 1 f
-- I - - - - -� � - - -� : I s
RT I
2 1 I I
DUVALL CT NE
2 _ J-1 GLT
Z��
- -
-'
`j
!
1 1F
STA 6 +42 20'
RT I
i 3 I
S LIG HT 8
,. _
I LSTA 4 +45, 22' RT — _ _
_
—
i
I ' ii
- - I
REMOVE
o ---- r -- - - --
:
A'
I
- - -
' ST LIGHT #7
--I F--- - - - - -7
_
_ _ _
t _
-
-_-:.
.—._ - "i.:
`��+ EXISTING UITILITY
(Z POLE.
i
/
/
I
L- - - --
o
J
L - - -
- JiL -
Ir
A19+98..65, 26' LT
I
I
i
I
I
ST LIGHT
-
r --
- - -
- - - - - -
I
L
J
,al 2 I
"
2 4
- - - --
__
- --
- -
-
---
-- _..__-_ - ---
.._.. . -- --
” - - - - -- -
---- --- --
- - - -- ----- - - -
- -- -- -- -
3
- - - - --
STA 4 +54, 41 "RT
--
3 4
\�
33
8 +00 7 +00
6 +00
5 +00
ST LIGHT #2
4 +00 3 +00
2 +00
I
+ 11 00
STA 6 +41, 41' RT
ST LIGHT #3
138th AVE SE (DUVALL AVE NE)
STA 1 +69, 41' R -
CONTACTOR CABINET !
±
-
STA 1 +55, 43' RT
ST LIGHT #1
I
f
EXISTING POWER
POLE W LUMINAIRE
19
'1
NO TES :,
OINSTALL ALUMINUM DAVIT STYLE LIGHT STANDARD W/ 100 WATT
HP SODIUM VAPOR /LUMINAIRE & LAMP - 25' MOUNTING HEIGHT
LUMINAIRE TO BE M250A2, MC N DISTRIBUTION FLAT LENS
W/ CUTOFF OPTICS.
OINSTALL ALT. "B" JUNCTION BOX
OINSTALL ALUMINUM DAVIT STYLE LIGHT STANDARD W/ 200 WATT
HP SODIUM VAPOR /LUMINAIRE & LAMP - 40' MOUNTING HEIGHT
LUMINAIRE TO BE M250A2, MC III DISTRIBUTION FLAT LENS
W/ CUTOFF OPTICS.
O4INSTALL STREET LIGHT CONTACTOR CABINET, 1201240 VOLT TYPE III
GROUNDED NEUTRAL SERVICE. CABINET 1148.
PROVIDE CIRCUIT BREAKERS & ONE CONTACTOR CABINET AS SHOWN ON
"STREET ILLUMINATION DETAILS SHEET" NO. 16.
CONDUIT & WIRING SCHEDULE
RUN NO.
CONDUIT'
SCHEDULE
LUMINAIRE
2" PVC - SCH. 80
3 - #2 SERVICE
STA 1+55 - 43 RT
2 "' PVC - SCH. 40
1 - #8 GROUND
IL
2275 E
2 - #8 T.H. W. CU.
DUVALL AVE. NE
3 - #' 12T. H. W. ( PEC j
3
3" PVC - SCH. 40
2 - #8 T.H.W. CU.
STA 4+54 -41 RT
40,
1 - #8 GROUND
200 WATTS
2" PVC - SCH. 80
1 - #8 GROUND
DUVALL AVE. NE
2 - #8 T.H. W. CU.
LEGEND
® SERVICE CABINET
® ✓UNC77ON BOX
ALUMINUM DAVIT STYLE LIGHT STANDARD
WITH HP SODIUM VAPOR /LUMINAIRE & LAMP
- — — — - CONDUIT
® a CONCRETE PAD SEE SHEET'! 16 & 16
FOR DETAILS!AND'',SPECIFICATI,ONS.
L 1
law FR If
I
I �7
I I IAXIAIAIRF .q('1-lFr)l /1 F CONTACTOR CABINET /D# 0042.
POLE l.D.#
POLE LOCATION
MH
ARM LENGTH
LUMINAIRE
C.R. POLE ID #
1
STA 1+55 - 43 RT
40'
8'
200 WATTS
2275 E
DUVALL AVE. NE
2
STA 4+54 -41 RT
40,
8'
200 WATTS
2277 E
DUVALL AVE. NE
3
STA 6+41 -41'RT
DUVALL AVE NE
40'
8"
200 WATTS
2279 E
4
STA 1 +75 -36LT
25"
8'
100 WATTS
2281 B
NE 10TH ST
5
STA 3+55 -36'LT
N 1 T
25'
8'
100 WATTS
2283 B
6
STA 2 +45 -22 RT
DUVALL CT NE
25"
8'
100 WATTS
2285 B
7
STA 4+4.5 -22'RT
DUVALL CT NE
25•
8"
100 WATTS
2287 B
8
STA 6+42 -22'RT
25'
8'
100 WATTS
2289 B
DUVALL CT NE
CHECKED FOR COMPLIANCE TO C17Y STANDARDS
SCANNED FEB 15 ZOE '