Loading...
HomeMy WebLinkAboutT-295213j C. Z C7I. RyL�\� A PORTION OF SW 1/4, SEC.31 T.23N, R.5E, W.M. II I � I Cj I 10 �. 10 1 3 / , a0 r�j. 1 1 - - - -- - - - - -, — _ I ----- - - - - -- p_ _ !— >____.. . — - = -- _ - - -- — --- .1�_Klf� -- - -- — — _ - - - = N- -- --- --- --- --- -- --- -- --- -- - - - --- + co co QI... .... .... .... .... .... .... .... ... I-I .... —B —LINE ...- _. I.I¢ --•. (A OD 183 +00 184 +00...,.,.• ..............•... 1'85 +00 :::188 +00. - -- ......:::._`._::..:' —_ ---.. `.`.t870UA m W - -- — i—==----- -I - - -- --- 1------= -1- - -- - - -i - - -F - -- - - --F -- -- - --I -- - -- i =- - - -- W Z::::....::::....::::....::::....::::....::: :....::::....::::....::::...... Z J I ... .. 1 . I. Q 4 1 4 6 4 2 2+ 3 I . 12 4 1 2 2 CL 12 2 1 \1 00 1 _l W CONSTRUCTION NOTES: OCONSTRUCT LUMINAIRE POLE FOUNDATION. PER CITY OF RENTON STANDARD PLAN SP J007 AND POLE, BRACKET ARM AND LUMINAIRE PER LUMINAIRE SCHEDULE, MANUFACTURER'S RECOMMENDATIONS AND SPECIAL PROVISIONS. O2 CONSTRUCT TYPE 1 JUNCTION BOX PER CITY OF RENTON STANDARD PLAN SP J016 AND SPECIAL PROVISIONS. O4 CONSTRUCT LUMINAIRE POLE FOUNDATION AT BACK OF SIDEWALK PER CITY OF RENTON STANDARD PLANS SP J007, J014, AND J015. O5 REMOVE AND SALVAGE LUMINAIRE POLE AND LUMINAIRE. REMOVE JUNCTION BOX AND ABANDON CONDUIT. REMOVE LUMINAIRE POLE FOUNDATION TO 24" MIN. BELOW FINISH GRADE. OCONSTRUCT TYPE 2 ITS SYSTEM JUNCTION BOX PER CITY OF RENTON STANDARD PLANS AND SPECIAL PROVISIONS. 10 SEE DUVALL PROJECT PLAN J005.1 11 SEE DUVALL.PROJECT PLAN J005.3 12 SEE DUVALL PROJECT PLAN J005.4 13 SEE DUVALL PROJECT PLAN J005 GENERAL NOTES: 1. THE JUNCTION BOX AND CONDUIT LOCATIONS SHOWN ON THESE PLANS ARE APPROXIMATE AND MAY BE ADJUSTED TO FIT FIELD CONDITIONS AS APPROVED BY THE ENGINEER PRIOR TO BEGINNING THE AFFECTED WORK. ILLUMINATION JUNCTION BOXES SHALL GENERALLY BE LOCATED WITHIN SIDEWALK AREAS AND ADJACENT TO THE EDGE OF SIDEWALK CLOSEST TO THE LUMINAIRE POLE. 2. ILLUMINATION AND COMMUNICATION CONDUITS ON THE EAST SIDE OF DUVALL AVENUE /COAL CREEK PARKWAY SHALL BE INCLUDED IN THE JOINT UTILITY TRENCH. SEE DWGS UG1 —UG16. KC MAP NO. 316-12 33301 9TH AVENUE SOUTH 14208 CALL 48 HOURS O r "° ; FEDERAL WAY, WASHINGTON '� BEFORE YOU DIG BERGER/ABAM 98003 -2600 IaNei �' E Np i N E E N,H 1 e C- VOICE: (206)431 -2300 -�� 1- 800 - 424 -5555 _ L-1 51—d m *d M 19 2008 1 07.'J.AV 6y A...f— RN-1 0120' NIFAPN7- 04 -OJII CAODI dxgrIlJ7JCO2d g Shye 1 - — \ � W 5 2 4 1 0^0 LUMINAIRE SCHEDULE LUM. NO. CIRCUIT WATTS MAST ARM LENGTH' STATION . OFFSET MTG. HT. 9 B 250 2' -3" 183 +38 37.0' RT 33 FT 10 A 250 T -10" 183 +40 41.0' LT 33 FT 11 B 250 2' -3" 184 +56 39.0' RT 33 FT 12 A 250 V -10" 184 +41 41.0' LT 33 FT 13 B 250 V -10" 185 +71 40.0' RT 33 FT 14 A 250 3' -10" 185 +72 41.0' LT 33 FT 15 B 250 V -10" 186 +75 40.0' RT 33 FT 16 A 250 T -10" 187 +11 41.0' LT 33 FT CENTER OF POLE TO CENTER OF LUMINAIRE ILLUMINATION WIRING SCHEDULE Q ._ RACEWAY CONDUIT SIZE (IN) ILLUMINATION WIRES REMARKS #4 #6 #8 GREEN 1 2 2 1 - #8 2 2 2 1 - #6 3 2 2 144 #4 4 4 ISPARE CITY ITS COMMUNICATION CONDUIT BY I DATE I APPR ARM N PT- EL L 20 0 20 40 71 J scale fleet KEY PLAN CITY OF DUVALL AVE NE / COAL CREEK PARKWAY SE 3/21/08 AN ,,.1, „, .s „. RENTON RECONSTRUCTION DATUM PI n ' /Building/Public works Dept. SE 107TH PLACE TO NEWCASTLE CITY LIMITS P roved For Constructiop / ILLUMINATION PLAN IL`Z M Hnn P_7 SHEET2 9E£ 137i83