Loading...
HomeMy WebLinkAboutT-295215C) J —I d) (y) T E, A PORTION OF NW 1,14, SEC.3, T.23N, R.5E, W.M. � � 411'-� (4) - -- - -- --- - - - - -- - F1 /a\ i--v — — — — — — — — — — — — — — — — — — — — — — — — — — -- - --= 5- 4 12 2 3 + C14 5 3 3 I .... .... I 07 z�............. .... .163 +b6 -. ED ......... 1s'4+bb.,.,..:..,., — 194+00 LLI JI I I — _ .. ...4 .... .... 1 I Q I - - - -- - - - - - - -- - - — F 7G5::- 1 a 4 3 � LUM. NO. CIRCUIT WATTS 2 12 STATION ill`f A l "- o I , f CONSTRUCTION NOTES: OCONSTRUCT TYPE 1 JUNCTION BOX PER CITY OF RENTON STANDARD PLAN SP J016 AND SPECIAL PROVISIONS. OCONSTRUCT LUMINAIRE POLE FOUNDATION AT BACK OF SIDEWALK PER CITY OF RENTON STANDARD PLANS SP J007, J014, AND J015. OREMOVE AND SALVAGE LUMINAIRE POLE AND LUMINAIRE. REMOVE JUNCTION BOX AND ABANDON CONDUIT. REMOVE LUMINAIRE POLE FOUNDATION TO 24" MIN. BELOW FINISH GRADE. 6 CONSTRUCT TYPE 2 ITS SYSTEM JUNCTION BOX PER CITY OF RENTON STANDARD PLANS AND SPECIAL PROVISIONS. 11 SEE DUVALL PROJECT PLAN J005.3 12 SEE DUVALL PROJECT PLAN J005.4 15 LUMINAIRES TO BE MOUNTED ON SIGNAL POLES. SEE DWG TS1 - TS3. 17 CONSTRUCT TYPE 25TA JUNCTION BOX PER DUVALL PROJECT PLAN J016.1 & J016.2 & SPECIAL PROVISIONS. GENERAL NOTES: 1. THE JUNCTION BOX AND CONDUIT LOCATIONS SHOWN ON THESE PLANS ARE APPROXIMATE AND MAY BE ADJUSTED TO FIT FIELD CONDITIONS AS APPROVED BY THE ENGINEER PRIOR TO BEGINNING THE AFFECTED WORK. ILLUMINATION JUNCTION BOXES SHALL GENERALLY BE LOCATED WITHIN SIDEWALK AREAS AND ADJACENT TO THE EDGE. OF SIDEWALK CLOSEST TO THE LUMINAIRE POLE. 2. ILLUMINATION AND COMMUNICATION CONDUITS ON THE EAST SIDE OF DUVALL AVENUE /COAL CREEK PARKWAY SHALL BE INCLUDED IN THE JOINT UTILITY TRENCH. SEE DWGS UG1 -UG16. T'-01K-at-oS1-800-424-5555 KC MAP NO.316 -12 33301 9TH AVENUE SOUTH CALL 48 HOURS *_. FEDERAL WAY, WASHINGTON BEFORE YOU DIG BEI2GER/ABAM 98003 -2600 -__ a -• -.-. (206)431 -2300 Lnf Snmd - Wed A 19 2W3 01 02.-J(PA1 b/ Arab— a% N e Or 12004IFAW- 04- 03210"l6gs I139- 1ZN..&g . 5,&v 7 NO. I REVISION 3 f— W �ll V) .■ N I I` 1 3 .... .... ....I� DUVALL AVE. NE I 196+00 197 +00 I Dp -- - -� - -- - -- I -- - - I - --I{ W .. IJ I= U LUMINAIRE SCHEDULE LUM. NO. CIRCUIT WATTS MASTARM LENGTH* STATION OFFSET MTG. HT. 24 A 250 T -10" 192 +33 40.0' LT 33 FT 25 B 250 T -10" 192 +69 40.0' RT 33 FT 26 A 250 T -10" 193 +74 40.0' LT 33 FT 4 B 250 2' -3" 194 +12 39.0' RT 33 FT 28 P7 C 250 2' -3" 196 +25 39.0' LT 33 FT 2 9 D 1 250 1 T -10" 1 196 +83 1 40.0' RT 33 FT "CENTER OF.POLE TO CENTER OF LUMINAIRE ILLUMINATION WIRING SCHEDULE X RACEWAY CONDUIT SIZE IN ILLUMINATION WIRES REMARKS #4 #6 #8 1 GREEN 1 2 2 1 - #8 2 2 2 1 - #6 3 2 2 1-#4 4 4 SPARE CITY ITS COMMUNICATION CONDUIT 5 2 4 2 1 - #4 6 [21 6 f2 1 - #4 7 [31 8 [2] 1 [1 - #41 [ #1 DENO- ES CONDUIT /WIRING INSTALLED AS PART OF SIGNAL SYSTEM. SEE SHEET TS1. BY I DATE I APPR NAS ARM uo,z DATUM JSGx fxcx scve r JSG d 20 0 20 40 i —1 scale feet KEY PLAN JAI a,o CITY OF DUVALL AVE NE / COAL CREEK PARKWAY SE 3/21/08 RENTON RECONSTRUCTION ng /Building /Public Works Dept. SE 107TH PLACE TO NEWCASTLE CITY LIMITS�xg pproved.For Constrvctlo ILLUMINATION PLAN IL4 3 SHEET 4 art u Hnncnn P F- � 139 163