CONSTRUCTION NOTES:
OCONSTRUCT LUMINAIRE POLE FOUNDATION. PER CITY OF RENTON STANDARD
PLAN SP J007 AND POLE, BRACKET ARM AND LUMINAIRE PER LUMINAIRE
SCHEDULE, MANUFACTURER'S RECOMMENDATIONS AND SPECIAL PROVISIONS.
OCONSTRUCT TYPE 1 JUNCTION BOX PER CITY OF RENTON STANDARD PLAN
SP J016 AND SPECIAL PROVISIONS.
OCONSTRUCT LUMINAIRE POLE FOUNDATION AT BACK OF SIDEWALK PER CITY
OF RENTON STANDARD PLANS SP J007, J014, AND J015.
O6 CONSTRUCT TYPE 2 ITS SYSTEM JUNCTION BOX PER CITY OF RENTON
STANDARD PLANS AND SPECIAL PROVISIONS. @2�3
OCONSTRUCT CONDUIT AND LUMINAIRE FOUNDATION PER
CONSTRUCT POLE BRACKET ARM AND LUMINAIRE PER LUMINAIRE SCHEDULE,
MANUFACTURER'S RECOMMENDATIONS AND SPECIAL PROVISIONS.
11 SEE DUVALL PROJECT PLAN J005.3
14 SEE DUVALL PROJECT PLAN J005.2
GENERAL NOTES:
1. THE JUNCTION BOX AND CONDUIT LOCATIONS SHOWN ON THESE
PLANS ARE APPROXIMATE AND MAY BE ADJUSTED TO FIT FIELD
CONDITIONS AS APPROVED BY THE ENGINEER PRIOR TO BEGINNING
THE AFFECTED WORK. ILLUMINATION JUNCTION BOXES SHALL
GENERALLY BE LOCATED WITHIN SIDEWALK AREAS AND ADJACENT
TO THE EDGE OF SIDEWALK CLOSEST TO THE LUMINAIRE POLE.
A PORTION OF-I W 1/4, SEC.3, T.23N, R.5E, W.M.
.-- - -�� -- .rte ^IS.�•Gx �: /� /.i,.L '�i.:- r —'..1� : /.�.�.. /.L
1
1
IN
ZA+00 U1
�m
l
'a
_ �-�
i
_.... _ _...— ...................._ i
1 �
i
2
2 4 '
LUMINAIRE
SCHEDULE
LUM. NO.
CIRCUIT
WATTS
MAST ARM
STATION
OFFSET
MTG. HT.
46
C
250
T -10"
207 +29
39.0' LT
33 FT
47
D
250
T -10"
207 +84
40.0' RT
33 FT
48
C
250
T -10"
208 +43
39.0' LT
33 FT
49
D
250
1 T -10"
208 +90
40.0' RT
33 FT
50
C
250
T -10"
209 +88
38.8' LT
33 FT
51
D
250
T -10"
210 +46
40.9' RT
33 FT
52
C
250
T -10"
210 +92 1 ]
34.5' LT
33 FT
53
D
250
T -10"
211 +46
37.9' RT
33 FT
* CENTER OF POLE TO CENTER OF LUMINAIRE 7�
NOTE: [1] COORDINATE FOUNDATION CONSTRUCTION WITH SOLDIER PILE
WALL
ILLUMINATION WIRING SCHEDULE
Q XRACEWAY
CONDUIT SIZE (IN)
ILLUMINATION WIRES
REMARKS
#4
#6
#8
GREEN
1
2
2
1-#8
2
2
2
1-#6
3
2
2
1-#4
4
4
SPARE CITY ITS COMMUNICATION CONDUIT
2. ILLUMINATION AND COMMUNICATION CONDUITS ON THE EAST SIDE
OF DUVALL AVENUE /COAL CREEK PARKWAY SHALL BE INCLUDED IN
THE JOINT UTILITY TRENCH. SEE DWGS UG1 —UG16.
S. GU
04 KC MAP NO.316 -12
REVISION NAS 8/26 /08
33301 9TH AVENUE SOUTH
GALL 48 HOURS "� FEDERAL WAY, WASHINGTON NAS
BEFORE YOU DIG BERGER/ABAM 98003 -2600
1- 800 - 424 -5555 VOICE: (206)431 -2300 iSG� DATUM
F7(PIA6 7ME 4, 80D —i King County - FAX: (206)431 -2250 NO. REVISION BY DATE APPR "^O1jss
L rl Sa d cw *d Am 27208 of la57A# br.Wom Fde #— a I76174IfAPW7- 04- 03TIC401 drosI742 A07.du &.I • I
20 0 20 40
scale feet KEY ;PLAN
E: CITY OF DUVALL AVE NE / COAL CREEK PARKWAY SE 3/21/08
RENTON RECONSTRUCTION
Planning /Building /Public Works Dept. SE 107TH PLACE TO NEWCASTLE CITY LIMITS w.,o,m
Approved For Construction ILLUMINATION PLAN �L7
�e+ „ W-- PF rl„te SHEET7 '°",a2 ;a: