Loading...
HomeMy WebLinkAboutT-295801CITY OF RENTON 51ANDARD PLAN& F— SHOWN ON SHEETS SU and SL3 N JR-02 SAD 30 FT. Di POLE JR-OS MAST AN WIRING DETAIL 0- JR-OS WPM LIGHTING UNDERGROUND SYSTEM CLJR-07 CONCRETE PAD DETAILS G \\ollllllllll�aO��eO \o\\000�" 1 I JR -10 STREET LIGHTING CONTRACTOR CABINET SCHEMATIC SCHEDULE= STATION TYPE III CIRCU LUMINAIRE Z z Q � JR-11 TYPE W SERWCE CABINET NUMBER DIST -WATTS a JR-35 LIGHT BASE AND JUNCTION BOX LOCATIONS 10' 1 +54, 21' LT. M -C -III -100 A 30' 1 °I° 10' ca JR-36A TYPICAL CONCRETE PAD DETAILS A STANDARD 10' z ® 1 +25, 24.5' LT. M- C- III -100 o JR-36 JUNCIM BOX DETAILS 0 ® J ; COAL NOTES: A CITY OF RENTON SO GO 1. PHOTOMETRIC CALCULATIONS ARE PER BCE DESIGN REPORT DATED APRIL 24, 2002. MAX. ® = W u LUMINAIRE SPACING IS 200 FL 40458 Lij w2 FUNCTIONAL CLASSIFICATION OF ALL 01 STREETS LOCAL RESIDENTIAL. 7 +10, 24.5' LT. M -C- III -100 A NEW LUMINAIRE ON NEW POLE N EX. �— 3. ALL STREET LIGHTING SHALT_. BE IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND M -C- III -100 A 25' SPECIFICATIONS. ! ® 1 +32, 12' LT. 4" CONDUIT RUNS IN BACK OF SIDEWALK SHILL HAVE 24" MIN. COVER WITH CDF BACKFILL A EX. 10' STREET CROSSINGS SHALL HAVE 30' MIN. COVER. E1 EXISTING E %. -150 5, TRAFFIC CONTROL PLANS SHALL. BE PROVIDED BY THE CONTRACTOR IN ACCORDANCE WITH 10' EX. 21 i6 CITY OF RENTON AND WSDOT SPECIFICATIONS AND APPROVED BY THE CITY ENGINEER. EXISTING EX. -150 IX. & ALL EXISTING AND PROPOSED UTILITIES SHALL RUN UNDERGROUND ALONG SITE FRONTAGE. -- ' 7. AVERAGE MAINTAINED ILLUMINATION: 0.30 FC (1 SIDE), 0.30 FC (STAGGERED), PROVIDED > 0.2 EX. -100 - m o FC MIN. REQUIRED PER CITY OF RENTON STANDARDS. 0 Z ® z m B. UNIFORMITY RATIO 3.00:1 (1 SIDE), 3.00:1 (STAGGERED) < 6.00:1 MAX. REQUIRED PER CITY EX. _ C) s`o OF RENTON STANDARDS. 7 2 CONSTRUCTION NOTES HW a Q INSTALL LUMINAIRE, FOUNDATON, HAPCO SERIES 21 POLE, MAST ARM, FIXTURE CONDUIT, AND \ JUNCTION BOX PER CITY OF RENTON STD. PLAN JR -02, JR -05, JR -06, JR -07, JR -35 AND JR -368 SEE SHLL15 SL2 AND SL3. LUMINAIRE SHALL BE 100 -WATT HPS 240V GENERAL ELECTRIC (G.E.) _ --° MODEL M2AC7CSBG2GMC32. (PHOTOMETRIC ID# 72851 PLEASE REFER TO BCE DESIGN REPORT m DATED APRIL B. 2002 FOR LUMINAIRE CATALOG CUT SHEETS. rn - O2 INSTALL TYPE -1" 120 /249V SERVICE CABINET #0054 PER CITY OF RENTON STANDARD PLANS JR -09, JR -10, AND JR -11. SERVICE CABINET SHALL BE SKYLINE MODEL 47700 -R. SEE BREAKER SCHEDULE o a ON THIS SHEET, STANDARD PLANS ON SHEETS SL2, SL3, AND SERVICE CABINET DETAIL ON SHEEP SL2 ST& 0 +35. Q INSTALL TYPE 1 JUNCTION BOX PER CITY OF RENTON STANDARD PLANS JR -07, JR -36. SEE SHEETS _ SL2 AND SL3. _ EXISTING METRO TRANSIT STOP (ROUTES 105,114 EXPRESS) TO REMAIN. o =_ O ROUTE CONDUIT TO PUGET SOUND ENERGY POWER VAULT. COORDINATE WITH PUGET SOUND ENERGY = FOR SERVICE CONNECTION. © INSTALL LUMINAIRE, FOUNDATION, HAPCO SERIES 21 POLE, MAST ARM, FIXTURE, CONDUIT, AND JUNCTION BOX PER CITY OF RENTON STANDARD PLANS JR -02, JR -05, JR -06 JR -07, JR -35, AND JR -368 SEE SHEETS Sit AND SL3. LUMiNATRE SHALL BE 100 -WATT 240V GENERAL ELECTRIC (G.E.) `g MODEL M2AC70SBG2GMG32. INSTALL PHOTO CELL ON NEW LUMINAIRE POLE EXISTING 100 -WATT PSE POWER POLE MOUNTED LUMINAIRE (UTILITY No. 318146- 167133) TO REMAIN. ® EXISTING PSE POWER POLE MOUNTED LUMINAIRE (UTILITY No. 318139 - 167133) TO REMAIN. O9 EXISTING PSE POWER POLE (UTILITY NO. 3'8126- 167134) TO REMAIN. ! 10 EXISTING PSE POWER POLE (UTILITY NO. 318167 - 167133) TO REMAIN. ! Ic 11 EXISTING 150 -WATT PSE POWER POLE MOUNTED LUMINAIRE (POLE NO. 2116) TO REMAIN. EXISTING 150 -WATT PSE POWER POLE MOUNTED LUMINAIRE (POLE NO. 2115 UTILITY NO. 318164- 167128) TO REMAIN. i I � a � a o_ x 1© EXISTING PSE POWER POLE (UTILITY NO. 318175 - 167128) TO REMAIN. !x N w 14 EXISTING JUNCTION BOX TO REMAIN. o �! EXISTING PSE POWER POLE (UTILITY N0. 318179 - 167728) TO REMAIN. f EXISTING PSE POWER POLE (POLE NO. 2114) TO REMAIN. EXISTING 150 -WATT PSE POWER MOUNTED LUMINAIRE (POLE NO. 2112, UTILITY NO. 318128 - 167129) TO REMAIN) TO REMAIN HEIGHT I MAST ARM LUMINAIRE SCHEDULE= STATION TYPE III CIRCU LUMINAIRE 30' STANDARD 10' NUMBER DIST -WATTS NEW LUMINAIRE ON NEW POLE ZZ !w w! STANDARD 10' 1 +54, 21' LT. M -C -III -100 A 30' 1 °I° 10' @ 3 +41, 17.5 RT. M -C- III -100 A STANDARD 10' z ® 1 +25, 24.5' LT. M- C- III -100 A 10' CITY OF RENTON 0 ® 3 +25, 24.5' LT. M -C- III -100 A CITY OF RENTON 'w a a; NEW LUMINAIRE ON NEW POLE ® 5 +10, 24.5' LT. M -C- III -100 A 40458 Lij 25' ® 7 +10, 24.5' LT. M -C- III -100 A NEW LUMINAIRE ON NEW POLE N EX. ® 9 +10, 24.5' LT. M -C- III -100 A 25' I ! ® 1 +32, 12' LT. M -C- III -100 A EX. 10' EX. E1 EXISTING E %. -150 IX. 10' EX. 21 i6 ® EXISTING EX. -150 IX. -- EXISTING EX. -100 EX. N 0 Z ® EXISTING EX-150 EX. HEIGHT BASE PLATE MAST ARM I BASE POLE No. REMARKS 30' STANDARD 10' CffY OF RENTON 40368 NEW LUMINAIRE ON NEW POLE 30' STANDARD 10' CITY OF RENTON 40358 NEW LUMINAIRE ON NEW POLE (PHOTOCELL) 30' STANDARD 10' CITY OF RENTON 4038B NEW LUMINAIRE ON NEW POLE 30' STANDARD 10' CITY OF RENTON 40398 NEW LUMINAIRE ON NEW POLE 30' STANDARD 10' CITY OF RENTON 40418 NEW LUMINAIRE ON NEW POLE 30' STANDARD 10' CITY OF RENTON 4043B NEW LUMINAIRE ON NEW POLE 30' STANDARD 10' CITY OF RENTON 40458 NEW LUMINAIRE ON NEW POLE 25' STANDARD 10' CITY OF RENTON 4037B NEW LUMINAIRE ON NEW POLE 25' EX. 10' EX. 2115 EXISTING LUMINAIRE AND PSE POLE TO REMAIN 25' EX. 10' EX. 2112 EXISTING LUMINAIRE AND PSE POLE TO REMAIN 25' EX. 10' EX. 2114 EXISTING LUMINAIRE AND PSE POLE TO REMAIN 25' EX. 10' EX. 21 i6 EXISTING LUMINAIRE AND PSE POLE TO REMAIN N 89'06'05" W 662.02 NE 4TH ST CONDUCTOR SCHEDULE: ¢-- RUN m PROPOSED TYPE 1 J-BOX ,Q EXISTING TYPE 1 J-BOX ® CIRCUIT CONDUCTOR CONDUIT REMARKS METRO 7RANSIT STOP 3 3" PVC SCHEDULE 80 ILLUMINATION UTILIZE Q _ No. 2 PSE TRENCH THROUGH POCKET PARK. DEPARTMENT OF PUBLIC WORKS r14A% STREET LIGHT PLAN SCHEDULE 80 ILLUMINATION UTILIZE 0 A 3 No. 8 2" PVC SAME TRENCH AS RUN 'S" ACROSS FaE No. Q�2 G<T'NG DRAWN TACOMA AVE. N.E. Q A 3 No. 8 1.5" PVC SCHEDULE 80 ILLUMINATION 3 No. B 2" PVC SCHEDULE 80 ILLUMINATION A 3 No. 12 AND PHOTOCELL A 3 No. 8 1 5" PVC SCHEDULE 80 ILLUMINATION A 3 No. 12 AND PHOTOCELL 0 A 3 No. 8 1.5" PVC SCHEDULE 80 ILLUMINATION UTILIZE PSE TRENCH ED A FOUND 4" CIXJ;i;- 16 15 MONUMENT W/NAL DIN 0.7 N c Cl r OF RENTON CONTROL POINT N0. 1503 VK MY MAP ��� WT3. T-2*95801 LEGEND PROPOSED STREET LIGHT ¢-- EXISTING STREET LIGHT m PROPOSED TYPE 1 J-BOX ,Q EXISTING TYPE 1 J-BOX 1 BOSOM TYPE 2 4-BOX CONDUIT - - -- m _PROPOSED PROPOSED SERVICE CABINET - METRO 7RANSIT STOP T-2*95801 24" MIN. COVER- J CONC. SIDEWALK NOTE - FOR 7.5' WIDE SIDEWALK CENTER 4, POLE BASE TO BE AT IN SIDEWALK AT 6.5 FROM BACK I OF CURB o DEVELOPER: NORTHWARD 15 0 -140TH AVENUE N.E., SUITE 100 LLEVU WA 98005 CONTACE E, RICHARD BERG (425) 747 -1726 ENGINEER: BARGHAUSEN CONSULTING ENGINEERS 18215 72nd AVENUE SOUTH KENT, WA 98032 (425) 251 -6222 OF LUMINAIRE BASE 11 uvG w— CURB AND GLITTER 24" MIN. COVER- J CONC. SIDEWALK J/ CONDUIT 1.5 FROM BACK OF CURB TYPICAL ROAD SECTION Hurl , S EET L:r -SIT itli i L i � i�� �.w1 NTS MCMAROM FOR APPROVAL. Date: 5- -31_0Z By. Date BY Date CITY OF RENTON DEPARTMENT OF PUBLIC WORKS r14A% STREET LIGHT PLAN ° COBBLESTONE DEVELOPMENT U ZS � DID DMS �� 4/08/02 FaE No. Q�2 G<T'NG DRAWN EN GIN�F. CFECI® HPG FELD BOOK PAGE_ APPRDV® '114INNto SEP 18 2002 I nIj 0