Loading...
HomeMy WebLinkAboutT-308901M i � � O _ I. ICJ g � a- o z w O � a w z Y O � ❑] J LLOO '3E I- a z aw Lj a a c n, �o =E yy �N O p� CD s NW it g r PORTION OF S.E. 1/4 OF N.W. 1/4 OF N.E. 1/4 OF SEC. 10, TWP. 23 N., RGE. 5 E., W.M. HOQUTAM 'AVE. N.E. 275.83 -__ U — - G!G07' 20 "E 3; - —..._. —_ — — —r POLE SCHEDULE POLE POLE CONDUCTORS POLE POLE LAMP TYPE M C -III H.P.S. LUMINAIRE, ARM MOUNTING MAST CIRCUIT NO_ ID NO. I STREET LOCATION OFFSET WATTAGE DISTRIBUTION HEIGHT ARM NO. 2193E HOQUTAM AVE NE 2 +36 22' RT. 200 M C -III 30' 8' 1 2 ` 2195E I HOQUTAM AVE NE 4 +11 22' RT. 200 M -C =III 30' - 8' 1 3 I 2197E i HOQUTAM AVE NE 5 +86 22' RT_ 200 M -C -III 30' 8' 1 WIRING SCHEDULE RUN NO_ ! CONDUIT CONDUCTORS REMARKS " PVC (SCHEDULE 40) 2 - #8, ; - #8 GREEN, 3 - #12 PHOTOCELL TYPE M C -III H.P.S. LUMINAIRE, ARM 2 1 5" PVC ;SCHEDULE 80) 2 - #8, 1 - #8 GREEN 3 t -" PVC (SCHEDULE 40) 2 - #8, 1 - #8 GREEN ' 4 PVC (SCHEDULE 40) 3 - #2 SERVICE 5" PVC (SCHEDDULE 40) INSTALL PULL WIRE ONLY i FOR FUTURE USE II I I 2 I I -GENERAL NOTES 1_ THE EXISTING TIMBER UTILITY POLES ALONG THE PROJECT FRONTAGE SHALL BE REPLACED WITH LONGER POLES TO ENSURE A MINIMUM C. TEN FEET OF CLEARANCE FROM ANY LIGHT STANDARD TO ANY POWER CONDUCTOR, INCLUDING THE NEUTRAL CONDUCTOR. NO LIGHT STANDARDS SHALL BE INSTALLED UNTIL THE NEW UTILITY POLES ARE INSTALLED AND THE REQUIRED CLEARANCE CAN BE MET. C%j1.4 UC I IOe14 NOTES oINSTALL FOUNDATION AND ELECTRICAL SERVICE CABINET AT HCQUTAM AVE. N.E., STA. 6 +47, 22' RT. LABEL CABINET AS #0078. ROUTE SERVICE ENTRANCE CONDUIT AND CONDUCTORS TO HANDHOLE TO B INSTALLED BY PUGET RECOMMENDED FOR APPROVAL —� �y l ^/ SOUND ENERGY COORDINATE WITH PSE FOR SERVICE CONNECTION. F i T— . LEGEND TYPE M C -III H.P.S. LUMINAIRE, ARM AND ALUMINUM DAVIT STYLE POLE LIGHT BASE AND JUNCTION BOX N IN CONCRETE PAD B TYPE 1 JUNCTION BOX WITH CONCRETE PAD ® ELECTRICAL SERVICE HANDHOLE BY PSE ® ELECTRICAL SERVICE CABINET - - - PVC CONDUIT (SEE WIRING SCHEDULE) AWIRE NOTE' OCONSTRUCTION NOTE -GENERAL NOTES 1_ THE EXISTING TIMBER UTILITY POLES ALONG THE PROJECT FRONTAGE SHALL BE REPLACED WITH LONGER POLES TO ENSURE A MINIMUM C. TEN FEET OF CLEARANCE FROM ANY LIGHT STANDARD TO ANY POWER CONDUCTOR, INCLUDING THE NEUTRAL CONDUCTOR. NO LIGHT STANDARDS SHALL BE INSTALLED UNTIL THE NEW UTILITY POLES ARE INSTALLED AND THE REQUIRED CLEARANCE CAN BE MET. C%j1.4 UC I IOe14 NOTES oINSTALL FOUNDATION AND ELECTRICAL SERVICE CABINET AT HCQUTAM AVE. N.E., STA. 6 +47, 22' RT. LABEL CABINET AS #0078. ROUTE SERVICE ENTRANCE CONDUIT AND CONDUCTORS TO HANDHOLE TO B INSTALLED BY PUGET RECOMMENDED FOR APPROVAL —� �y l ^/ SOUND ENERGY COORDINATE WITH PSE FOR SERVICE CONNECTION. F i