Loading...
HomeMy WebLinkAboutT-308903M \ I � � J o- z n 0-16 oy LL z 00 �._ 3:¢ I— w �w �o ` -E E -E �N C -. lI O a� oP � Qo �a o C4 x x to Q m POLE SCHEDULE PORTION OF ':;:.E_. 1/4 OF N.W. 1/4 OF N.E. 1/4 OF SEC. 10, TWP. 23 N., RGE. 5 E., W.M. _ �... Crl __ _ ... r ._... ....... l --� — — — — — IIII �i/ J411�11 I vj i HOQUTAM AVE. N.E. ........ ._ -_P N00 °07'20' EcZ 329:5.77 .... . 2 - POLE NO. POLE !D NO. STREET POLE LOCATION POLE OFFSET LAMP WATTAGE DISTRIBUTION MOUNTING HEIGHT MAST ARM CIRCUIT NO. 1 2193E HOQUTAM AVE NE 2 +36 1842= RT. 200 M -C -III 30' 8' 1 2 2195E HOQUTAM AVE NE 4 +11 10'-2 -2-! RT. 200 M -C -III 1 30 8' 1 3 2197E HOQUTAM AVE NE 5 +86 IBzz RT. 200 M -C -III 30 8' 1 1 WIRING SCHEDULE RUN NO. CONDUIT CONDUCTORS REMARKS 1 1.5" PVC (SCHEDULE 40) 2 - #8, 1 - #8 GREEN, 3 - #12 PHOTOCELL LIGHT BASE AND JUNCTION BOX 2 1.5" PVC (SCHEDULE 80) 2 - #8, 1 - #8 GREEN TYPE 1 JUNCTION BOX WITH CONCRETE PAD 3 1.5" PVC (SCHEDULE 40) 2 - #8, 1 - #8 GREEN ELECTRICAL SERVICE CABINET 4 1.5" PVC (SCHEDULE 40) 3 - #2 SERVICE 5 1.5" PVC (SCHEDULE 40) INSTALL PULL WIRE ONLY FOR FUTURE USE CONSTRUCTION NOTES o LU 1 INSTALL FOUNDATION AND ELECTRICAL SERVICE CABINET AT HOQUTAM AVE. N.E., STA. 6 +47, 22' RT. LABEL CABINET AS #0078. OROUTE SERVICE ENTRANCE CONDUIT AND CONDUCTORS TO HANDHOLE TO BE INSTALLED BY PUGET SOUND ENERGY (PSE). COORDINATE WITH PSE FOR SERVICE CONNECTION. 0 z 0 i -- LEGEND =1 Minim a Y`( TYPE M -C -III H.P.S. LUMINAIRE, ARM OF TEN FEET OF CLEARANCE NEUTRAL CONDUCTOR. AND ALUMINUM DAVIT STYLE POLE ® LIGHT BASE AND JUNCTION BOX CLEARANCE CAN BE MET. WITH CONCRETE PAD 8 TYPE 1 JUNCTION BOX WITH CONCRETE PAD 0 ELECTRICAL SERVICE HANDHOLE BY PSE ® ELECTRICAL SERVICE CABINET 0 10 20 40 — — — PVC CONDUIT (SEE WIRING SCHEDULE) WIRE NOTE OCONSTRUCTION NOTE GENERAL NOTES T V30 03 � RECORD pOCUYENT 1. THE EXISTING TIMBER UTILITY POLES ALONG THE PROJECT FRONTAGE SHALL BE REPLACED WITH LONGER POLES TO ENSURE A MINIMUM CONDUCTOR, INCLUDING THE OF TEN FEET OF CLEARANCE NEUTRAL CONDUCTOR. FROM ANY LIGHT STANDARD TO ANY POWER NO LIGHT STANDARDS SHALL BE INSTALLED UNTIL �,��� sY �' --- THE NEW UTILITY POLES ARE INSTALLED AND THE REQUIRED CLEARANCE CAN BE MET. g_u —oy RECOMMENDED FOR APPROVAL BY DATE l Z 143 ���MAs�y q H � BY s� DATE P2 �P 3073 ell �� RfGIST 0 0 ID HERMAN TRAFFIC ENGINEERING BY DATE SSONALENG 1i 6 -0; 15324 Southeast 133rd Court, Renton, Washington 98059 EXPIRES o1 /3' /05 425- 277 -1740 tel. 425- 277 -5718 fax hte @comcast.net sCarvNED OCT 0 8 �+ 7- B,`yry,f;,� C`r� -. SCANNED MAR 29 .2cvA w