HomeMy WebLinkAboutT-316901BENCHMARKS: SW 1/4 , NE 1/4, SECTION 5, TOWNSHIP 23 N, RANGE 5 E, W.M.
a ORIGINAL BM: 1 /820TOHPST. &IJONESCAVENUEENE. CITY OF RENTON � 1839E ELEV. = 20910E
Lo Nt _NOTES: CONSTRUCTION NOTES:
TBM -A: SET "X" IN CENTER CAP BOLT OF FIRE HYDRANT IN THE SOUTHWEST QUADRANT - -- -
OF PROJECT NORTH SIDE OF NE 20TH ST. & APPROX. ±540 FEET EAST OF
JONES AVENUE NE., ELEV. = 259.88 THE CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL PLANS IN
TBM -B: RAILROAD SPIKE IN THE NORTHEAST FACE OF POWER POLE ON THE SOUTH ACCORDANCE WITH CITY OF RENTON STANDARDS. THE TRAFFIC CONTROL (D INSTALL TYPE 1 JUNCTION BOX PER CITY OF RENTON STANDARD PLAN
SIDE OF NE 20Tji ST. AT THE NORTHEAST LOT CORNER OF HOUSE #1901 PLANS SHALL BE APPROVED PRIOR TO COMMENCING ANY WORK WITHIN JR -36 (SEE SHEET SL -2), AND ROUTE CONDUIT TO PUGET SOUND
,
ELEV. = 263.03 THE PUBLIC RIGHT OF WAY. ENERGY POWER SOURCE. COORDINATE WITH PUGET SOUND ENERGY FOR
z ALL ROADWAY LIGHTING SHALL BE INSTALLED IN ACCORDANCE WITH CITY SERVICE CONNECTION. #Omq
Q OF RENTON STANDARDS AND SPECIFICATIONS O INSTALL TYPE III 120/240 V SERVICE CABINEYVND FOUNDATION PER CITY
i OF RENTON STANDARD PLANS JR -09, JR -10, AND JR -11 (SEE SHEET
Q" DATUM NE 20TH STREET IS A RESIDENTIAL COLLECTOR STREET. SL -2). SERVICE CABINET SHALL BE SKYLINE MODEL 47700 -R OR
CITY OF RENTON (NAVD 88) PROPOSED INTERIOR ROADS ARE LOCAL RESIDENTIAL STREETS. APPROVED EQUAL. REFER TO BREAKER SCHEDULE THIS SHEET.
z (� -
Lu Z O INSTALL LUMINAIRE, FIXTURE, MAST ARM, POLE (HAPCO SERIES 21),
_ _ _ FOUNDATION, JUNCTION BOX, AND CONDUIT PER CITY OF RENTON
STANDARD PLANS JR =02, JR -05, JR -06, JR -07, JR -35, AND JR -36A
IJJ - - I - - - (SEE SHEETS SL -2 AND MD -1) LUMINAIRE SHALL BE 100 -WATT 240 V
HPS (GENERAL ELECTRIC MODEL M2AC1OS8G2GMC32).
F O INSTALL PHOTO CELL ON NEW LUMINAIRE POLE.
oC I 08 I 11 I I
W I
= H I 3
W
w LUMINAIRE L4 3
a I STA 1'4 +47.021 .90'LT
~ I �� 20 ( CITY OF RENTON STANDARD PLANS
CO) / \ I Ci SEE SHEETS SL -2 AND MD-1
I NO. TITLE
JR -02 STANDARD 30 FT DAVIT POLE
JR -05 MAST ARM WIRING DETAIL
/ o I I I JR -06 TYPICAL LIGHTING UNDERGROUND SYSTEM
I + • I
n.� I � ( TI JR =07 CONCRETE PAD DETAILS.
0 0 - - - - - - _�/ JR -09 STREET LIGHT CONTACTOR CABINET
y ( AND CABINET FOUNDATION
~T-+ c Z JR -10 STREET LIGHTING CONTACTOR CABINET SCHEMATIC
Q 3-E \ / 21 ( JR -11 TYPE III SERVICE CABINET
UQ I ((� JR -35 _ LIGHT BASE AND JUNCTION BOX LOCATIONS
Z = ( 1 3 LUMINAIRE L5 3 LUMINA RE L6 i s �� � JR -36A TYPICAL CONCRETE PAD DETAILS
�_ Wty ava I 2 STA 18 +03.10, 24.00'LT I JR -36 JUNCTION BOX DETAILS
\ c STA 1 90.74, 30.66'LT Q
h+-I o v I I I 13 14 `g tin; O=
sE W
oc (D2
UFN �, a� 2 2 3 2/ I LEGEND
Al
€m -- — 17' I
l
I- PROPOSED STREET LIGHT
a� I -
PROPOSED TYPE 1 J -BOX
--- � _ 17 +00 - - 18 +00 _ 19 +00 B � I
—P—PROPOSED CONDUIT
s
� - I ^'l ® PROPOSED SERVICE CABINET
LUMINAIRE #L3 NE 21ST STREET 1
STA 1 4� 14.47, 26.00'RT
1 / I CONDUCTOR SCHEDULE
O
MAIN BREAKER
AMPS
BRANCH BREAKER
AMPS
�j�t G�
\�\ •-•i
I 1
CIRCUIT
CONDUCTOR
CONDUIT
REMARKS
LJ
°o W
3 - No.2
3" PVC
SCH. 80
1Q
A
z
2" PVC
SCH. 80
4
\\
\
N Y v
W/ PHOTOCELL
Q2
A
3 - No.8
2" PVC
SCH. 80
Q3
A
I
I JI I
SCH. 80
STANDARD
12'
CITY OF RENTON
NEW LUMINAIRE, NEW POLE
I
14 +47.02, 3.90'LT
M -C.- III -100
A
30'
STANDARD
10'
CITY OF RENTON
NEW LUMINAIRE, NEW POLE
L5
18 +03.10, 24.00'LT
M -C -I11-100
A
30'
STANDARD
10'
CITY OF RENTON
a5$
NEW LUMINAIRE, NEW POLE
L6
19 +90.74, 30.66'1-T
+
A
30'
a
10'
CITY OF RENTON
S
NEW LUMINAIRE, NEW POLE
�/
M
N I
I i
Co N
I
N
cn
g
z
I
+
W
N
t 32 I :2
I
2 II
34
LUMINAIR L2
STA 11 +89.57, 24.00'LT I I 00
+ z I <I
3 NInJ. I -- -- --
r; I z
°
+
� 2
X11'
3
UMINAIRE #L1
0 0 Z I 4 3 $TA 10 +26.07, 26.96'LT
z 0
o vl
w
of
0 RECOMMENDED FOR APPROVAL
5 By: Date:
By Date:
i
B % Date:` D
z By: Date:
Cost Saved o Thu Mar 04 2004 of 3.03pm by BN Helstey Fite Nome. R: IPro/ectsl108(Comwest) I 001- OJIdwglsheets -FO �HGJtOl.dwg Scale: 40
G
PHOTOCELL � - I -
39 +00 040100 41 +00
- NE, 20TH. ,STREET
1 S 2 1 ,r
I
I
I
I
I
Tm 316yug
i
i
BREAKER SCHEDULE
SERVICE
& CIRCUITS
MAIN BREAKER
AMPS
BRANCH BREAKER
AMPS
CONTACTOR
AMPS
REMARKS
RUN
CIRCUIT
CONDUCTOR
CONDUIT
REMARKS
QS
A
3 - No.2
3" PVC
SCH. 80
1Q
A
3 - No.8
2" PVC
SCH. 80
L2
11 +89.57, 24.00'LT
3 - No.12
A
W/ PHOTOCELL
Q2
A
3 - No.8
2" PVC
SCH. 80
Q3
A
3 - No.8
1 VPVC
SCH. 80
BREAKER SCHEDULE
SERVICE
& CIRCUITS
MAIN BREAKER
AMPS
BRANCH BREAKER
AMPS
CONTACTOR
AMPS
REMARKS
SERVICE
100A
BASE
POLE NO.
REMARKS
REMARKS
CIRCUIT A
10 +26.07, 26.96'LT
30A
30A
ILLUMINATION
CIRCUIT B
10'
30A
30A
ILLUMINATION SPARE
L2
11 +89.57, 24.00'LT
M- C- III -100
A
30'
STANDARD
10'
CITY OF RENTON
NEW LUMINAIRE, NEW POLE
L3
16 +14.47, 26.00'RT
M -C- III -100
A
30'
LUMINAIRE SCHEDULE
LUMINAIRE
NUMBER
STATION
TYPE III DIST -WATTS
CIRCUIT
MTG.
HT.
BASE
PLATE
MAST
ARM
BASE
POLE NO.
REMARKS
REMARKS
L1
10 +26.07, 26.96'LT
M -C- III -100
A
30'
STANDARD
10'
CITY OF RENTON
NEW LUMINAIRE, NEW POLE, PHOTOCELL
L2
11 +89.57, 24.00'LT
M- C- III -100
A
30'
STANDARD
10'
CITY OF RENTON
NEW LUMINAIRE, NEW POLE
L3
16 +14.47, 26.00'RT
M -C- III -100
A
30'
STANDARD
12'
CITY OF RENTON
NEW LUMINAIRE, NEW POLE
L4
14 +47.02, 3.90'LT
M -C.- III -100
A
30'
STANDARD
10'
CITY OF RENTON
NEW LUMINAIRE, NEW POLE
L5
18 +03.10, 24.00'LT
M -C -I11-100
A
30'
STANDARD
10'
CITY OF RENTON
a5$
NEW LUMINAIRE, NEW POLE
L6
19 +90.74, 30.66'1-T
M -C- III -100
A
30'
STANDARD
10'
CITY OF RENTON
S
NEW LUMINAIRE, NEW POLE
42 +00 43 +00 44 +00 45 +0045 +2
ty'f
tJ
Cpl)
C;
� z
o
L�
E
;o
`m
1�
I
I�
Vf p
NCI
*- -°
p ml
UZ
Co
ul m
Q o i
I�0
94io��
E m LL
yl
00
m
' >yi
�Ic4
Q% :2 U
j
to - 0
c
J M
o 1 v
r rn�N
N OQOf O
3 I to
mZ C0 V
30vI°
13 N ,_ ` If) C
O Go ) ._ N O
U W fnY�U
Z Q
W
(J IL
0/ o
`z
�W
V
Q _.4
Uj
W
W
.L I iii
SL-1
40 0 40 80
1 " =40 SHEET n C
scale feet G aj
OF 27
c�;T i6go/ SCANIIw OCT 08 '�
i