Loading...
HomeMy WebLinkAboutT-316901BENCHMARKS: SW 1/4 , NE 1/4, SECTION 5, TOWNSHIP 23 N, RANGE 5 E, W.M. a ORIGINAL BM: 1 /820TOHPST. &IJONESCAVENUEENE. CITY OF RENTON � 1839E ELEV. = 20910E Lo Nt _NOTES: CONSTRUCTION NOTES: TBM -A: SET "X" IN CENTER CAP BOLT OF FIRE HYDRANT IN THE SOUTHWEST QUADRANT - -- - OF PROJECT NORTH SIDE OF NE 20TH ST. & APPROX. ±540 FEET EAST OF JONES AVENUE NE., ELEV. = 259.88 THE CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL PLANS IN TBM -B: RAILROAD SPIKE IN THE NORTHEAST FACE OF POWER POLE ON THE SOUTH ACCORDANCE WITH CITY OF RENTON STANDARDS. THE TRAFFIC CONTROL (D INSTALL TYPE 1 JUNCTION BOX PER CITY OF RENTON STANDARD PLAN SIDE OF NE 20Tji ST. AT THE NORTHEAST LOT CORNER OF HOUSE #1901 PLANS SHALL BE APPROVED PRIOR TO COMMENCING ANY WORK WITHIN JR -36 (SEE SHEET SL -2), AND ROUTE CONDUIT TO PUGET SOUND , ELEV. = 263.03 THE PUBLIC RIGHT OF WAY. ENERGY POWER SOURCE. COORDINATE WITH PUGET SOUND ENERGY FOR z ALL ROADWAY LIGHTING SHALL BE INSTALLED IN ACCORDANCE WITH CITY SERVICE CONNECTION. #Omq Q OF RENTON STANDARDS AND SPECIFICATIONS O INSTALL TYPE III 120/240 V SERVICE CABINEYVND FOUNDATION PER CITY i OF RENTON STANDARD PLANS JR -09, JR -10, AND JR -11 (SEE SHEET Q" DATUM NE 20TH STREET IS A RESIDENTIAL COLLECTOR STREET. SL -2). SERVICE CABINET SHALL BE SKYLINE MODEL 47700 -R OR CITY OF RENTON (NAVD 88) PROPOSED INTERIOR ROADS ARE LOCAL RESIDENTIAL STREETS. APPROVED EQUAL. REFER TO BREAKER SCHEDULE THIS SHEET. z (� - Lu Z O INSTALL LUMINAIRE, FIXTURE, MAST ARM, POLE (HAPCO SERIES 21), _ _ _ FOUNDATION, JUNCTION BOX, AND CONDUIT PER CITY OF RENTON STANDARD PLANS JR =02, JR -05, JR -06, JR -07, JR -35, AND JR -36A IJJ - - I - - - (SEE SHEETS SL -2 AND MD -1) LUMINAIRE SHALL BE 100 -WATT 240 V HPS (GENERAL ELECTRIC MODEL M2AC1OS8G2GMC32). F O INSTALL PHOTO CELL ON NEW LUMINAIRE POLE. oC I 08 I 11 I I W I = H I 3 W w LUMINAIRE L4 3 a I STA 1'4 +47.021 .90'LT ~ I �� 20 ( CITY OF RENTON STANDARD PLANS CO) / \ I Ci SEE SHEETS SL -2 AND MD-1 I NO. TITLE JR -02 STANDARD 30 FT DAVIT POLE JR -05 MAST ARM WIRING DETAIL / o I I I JR -06 TYPICAL LIGHTING UNDERGROUND SYSTEM I + • I n.� I � ( TI JR =07 CONCRETE PAD DETAILS. 0 0 - - - - - - _�/ JR -09 STREET LIGHT CONTACTOR CABINET y ( AND CABINET FOUNDATION ~T-+ c Z JR -10 STREET LIGHTING CONTACTOR CABINET SCHEMATIC Q 3-E \ / 21 ( JR -11 TYPE III SERVICE CABINET UQ I ((� JR -35 _ LIGHT BASE AND JUNCTION BOX LOCATIONS Z = ( 1 3 LUMINAIRE L5 3 LUMINA RE L6 i s �� � JR -36A TYPICAL CONCRETE PAD DETAILS �_ Wty ava I 2 STA 18 +03.10, 24.00'LT I JR -36 JUNCTION BOX DETAILS \ c STA 1 90.74, 30.66'LT Q h+-I o v I I I 13 14 `g tin; O= sE W oc (D2 UFN �, a� 2 2 3 2/ I LEGEND Al €m -- — 17' I l I- PROPOSED STREET LIGHT a� I - PROPOSED TYPE 1 J -BOX --- � _ 17 +00 - - 18 +00 _ 19 +00 B � I —P—PROPOSED CONDUIT s � - I ^'l ® PROPOSED SERVICE CABINET LUMINAIRE #L3 NE 21ST STREET 1 STA 1 4� 14.47, 26.00'RT 1 / I CONDUCTOR SCHEDULE O MAIN BREAKER AMPS BRANCH BREAKER AMPS �j�t G� \�\ •-•i I 1 CIRCUIT CONDUCTOR CONDUIT REMARKS LJ °o W 3 - No.2 3" PVC SCH. 80 1Q A z 2" PVC SCH. 80 4 \\ \ N Y v W/ PHOTOCELL Q2 A 3 - No.8 2" PVC SCH. 80 Q3 A I I JI I SCH. 80 STANDARD 12' CITY OF RENTON NEW LUMINAIRE, NEW POLE I 14 +47.02, 3.90'LT M -C.- III -100 A 30' STANDARD 10' CITY OF RENTON NEW LUMINAIRE, NEW POLE L5 18 +03.10, 24.00'LT M -C -I11-100 A 30' STANDARD 10' CITY OF RENTON a5$ NEW LUMINAIRE, NEW POLE L6 19 +90.74, 30.66'1-T + A 30' a 10' CITY OF RENTON S NEW LUMINAIRE, NEW POLE �/ M N I I i Co N I N cn g z I + W N t 32 I :2 I 2 II 34 LUMINAIR L2 STA 11 +89.57, 24.00'LT I I 00 + z I <I 3 NInJ. I -- -- -- r; I z ° + � 2 X11' 3 UMINAIRE #L1 0 0 Z I 4 3 $TA 10 +26.07, 26.96'LT z 0 o vl w of 0 RECOMMENDED FOR APPROVAL 5 By: Date: By Date: i B % Date:` D z By: Date: Cost Saved o Thu Mar 04 2004 of 3.03pm by BN Helstey Fite Nome. R: IPro/ectsl108(Comwest) I 001- OJIdwglsheets -FO �HGJtOl.dwg Scale: 40 G PHOTOCELL � - I - 39 +00 040100 41 +00 - NE, 20TH. ,STREET 1 S 2 1 ,r I I I I I Tm 316yug i i BREAKER SCHEDULE SERVICE & CIRCUITS MAIN BREAKER AMPS BRANCH BREAKER AMPS CONTACTOR AMPS REMARKS RUN CIRCUIT CONDUCTOR CONDUIT REMARKS QS A 3 - No.2 3" PVC SCH. 80 1Q A 3 - No.8 2" PVC SCH. 80 L2 11 +89.57, 24.00'LT 3 - No.12 A W/ PHOTOCELL Q2 A 3 - No.8 2" PVC SCH. 80 Q3 A 3 - No.8 1 VPVC SCH. 80 BREAKER SCHEDULE SERVICE & CIRCUITS MAIN BREAKER AMPS BRANCH BREAKER AMPS CONTACTOR AMPS REMARKS SERVICE 100A BASE POLE NO. REMARKS REMARKS CIRCUIT A 10 +26.07, 26.96'LT 30A 30A ILLUMINATION CIRCUIT B 10' 30A 30A ILLUMINATION SPARE L2 11 +89.57, 24.00'LT M- C- III -100 A 30' STANDARD 10' CITY OF RENTON NEW LUMINAIRE, NEW POLE L3 16 +14.47, 26.00'RT M -C- III -100 A 30' LUMINAIRE SCHEDULE LUMINAIRE NUMBER STATION TYPE III DIST -WATTS CIRCUIT MTG. HT. BASE PLATE MAST ARM BASE POLE NO. REMARKS REMARKS L1 10 +26.07, 26.96'LT M -C- III -100 A 30' STANDARD 10' CITY OF RENTON NEW LUMINAIRE, NEW POLE, PHOTOCELL L2 11 +89.57, 24.00'LT M- C- III -100 A 30' STANDARD 10' CITY OF RENTON NEW LUMINAIRE, NEW POLE L3 16 +14.47, 26.00'RT M -C- III -100 A 30' STANDARD 12' CITY OF RENTON NEW LUMINAIRE, NEW POLE L4 14 +47.02, 3.90'LT M -C.- III -100 A 30' STANDARD 10' CITY OF RENTON NEW LUMINAIRE, NEW POLE L5 18 +03.10, 24.00'LT M -C -I11-100 A 30' STANDARD 10' CITY OF RENTON a5$ NEW LUMINAIRE, NEW POLE L6 19 +90.74, 30.66'1-T M -C- III -100 A 30' STANDARD 10' CITY OF RENTON S NEW LUMINAIRE, NEW POLE 42 +00 43 +00 44 +00 45 +0045 +2 ty'f tJ Cpl) C; � z o L� E ;o `m 1� I I� Vf p NCI *- -° p ml UZ Co ul m Q o i I�0 94io�� E m LL yl 00 m ' >yi �Ic4 Q% :2 U j to - 0 c J M o 1 v r rn�N N OQOf O 3 I to mZ C0 V 30vI° 13 N ,_ ` If) C O Go ) ._ N O U W fnY�U Z Q W (J IL 0/ o `z �W V Q _.4 Uj W W .L I iii SL-1 40 0 40 80 1 " =40 SHEET n C scale feet G aj OF 27 c�;T i6go/ SCANIIw OCT 08 '� i