HomeMy WebLinkAboutT-319502a
kn
:i'1
S cry
a o
� o
C)
I � a
CN
*As N
0
,M
g
POLE
ID. NO.
CIRCUIT
NO.
x
OFFSET
(FEET)
Z
MAST ARM
(FEET)
MOUNTING
HGT. (FT.)
20
4617B
B
N.E. 1ST ST. 6 +00
22.5' RT.
100
8'
25
ZD
Z
B
=
O
100
J
W
�
Q
22
cr—
Z
N.E. 1ST ST. 9 +03
22.5 LT.
100
8'
25'
23
a
L
3
c
•
oil o
a
1' 21'
I
e oil
NW I/4. NW I/4. SEC. N. TWP- 23 N., RGE. 5 E.. W.M.
t
A
5' � 25
i
i
i
41
i
QI
%-41
I
V �
3 N6
I
LUMINAIRE SCHEDULE
LUM.
NO.
POLE
ID. NO.
CIRCUIT
NO.
LOCATION
OFFSET
(FEET)
LAMP
WATTAGE
MAST ARM
(FEET)
MOUNTING
HGT. (FT.)
20
4617B
B
N.E. 1ST ST. 6 +00
22.5' RT.
100
8'
25
21
4606B
B
N.E. 1ST ST. 7 +65
22.5 LT.
100
8
25'
22
4608B
B
N.E. 1ST ST. 9 +03
22.5 LT.
100
8'
25'
23
4610B
B
N.E. 1ST ST. 10 +71
22.5' LT.
100
8'
25'
24
4612B
B
BREMERTON AVE. N.E. 12 +11
22.5' LT.
100
8'
25'
25
46148
B
BREMERTON AVE. N.E. 13 +62
22.5 LT.
100
8'
25'
26
46198
B
BREMERTON AVE. N.E. 15 +07
22.5 RT.
100
8'
25'
27
4616B
B
N.E. 1ST CT. 0 +76
22.5' RT.
100
8'
25'
28
4621B
B
N.E. 1ST CT. 2 +56
22.5' LT.
100
8'
25'
29
4623B
B
N.E. 1ST CT. 4 +36
22.5' LT.
100
8'
25'
30
4625B
D
DUVALL AVE. N.E. 2 +54
22.5' RT.
100
8'
25'
31
46278
D
DUVALL AVE. N.E. 4 +34
22.5' RT.
100
8'
25'
32
46298
D
DUVALL AVE. N.E. 6 +14
22.5' RT.
100
8'
25'
33
4631B
D
DUVALL AVE. N.E. 7 +94
22.5' RT.
100
8'
25'
34
4633B
A
DUVALL AVE. N.E. 9 +50
22.5' RT.
100
8'
25'
WIRING SCHEDULE
CONDUIT
RUN
CONDUIT
SIZE
CONDUCTORS
NOTES
1
1.5" PVC
(SCHEDULE
40)
2 - #6,
1 -#6 GREEN
2
1.5" PVC
(SCHEDULE
80)
2--#6,
1 -#6 GREEN
3
1.5 pp PVC
(SCHEDULE
80)
4 -#61
1 -#6 GREEN
4
2 PVC
SCHEDULE 40
6 -#6,
1 -#6 GREEN
5
2 to PVC
SCHEDULE 40
8 -#6,
3 - #14
1 -#6 GREEN
PHOTOCELL
6
1.5 PVC
SCHEDULE
40
2 - #6,
3 - #14
1 -#6 GREEN
PHOTOCELL
Tqm 3100v502
` CONSTRUCTION NOTE I
)91 11 6 O `, 1
CONSTRUCTION NOTES
SCALE: 1" = 40' ' INSTALL
I 9 0 CONCRETE FOUNDATION, LIGHT STANDARD AND
0 20 40 so I LUMINAIRE PER POLE SCHEDULE.
2 INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD.
1 i I 3 INSTALL FOUNDATION AND ELECTRICAL SERVICE CABINET
Tal
N8879Z8 "w 1 I 91 # 0087 AT DUVALL AVE. N.E. APPROX. STA 8 +04, 23' RT.
Lai
--- �. --�- -- -- _ COIL 3 OF 2 —#6 CONDUCTOR FOR FUTURE CIRCUIT C.
------- --- - -- - --. `�" 25 125 COORDINATE WITH PSE FOR SERVICE CONNECTION.
Ohl /2\
ir— _ I 2 4 COIL 5 OF 2 - #6 CONDUCTORS FOR FUTURE CIRCUIT C.
1 1J ---- .� 1
r
I I i I I C
CL :W N 22'42OW _
-, % 92
TRACT M 2
o I 1
TRACT I ! 1
Z
0
� I rv. -aiir
• 0 s
ROLL 1 9��
94
1
9,5
avow 404
1 j
1 /
h
tM /S
TRANSPORTATION PLANNING do ENGINEERING, INC.
2223 112TH AVE NE, SUITE 101, BELLEVUE WA 98004 (425)455 -5320
C r*3,. T= ?/V re z m ss
1
E
L