FUSE KITS
QUICK DISCONNECT
10 AMP IN LINE FUSE
KITS - S.E.C. OR EQUAL
TYPICAL DESIGN 'B'
JUNCTION BOX
SPLICE KITS
GROUND LUG
CLEAR EPDXY SPLICE
KITS ON ALL THRU
WIRE RUNS
2' MIN. GROUT
UNDER PALE BASE
PAD CONCRETE
5' 9,
48 BARE
COPPER
GROUND WIRE �
2- (SIZED AS REQ'D)
LIGHTING SYSTEM
WIRES TO CONTACTOR
&N,
J
5/8'x8'
COPPER -CLAD
GROUND ROD-
=III °1111 =III
1111 - 1111 - 1111 =1111 II
IIII_ II
— GUN II
TO LUMINAIRE
1/4" MINIMUM
DRAIN HOLE
TOP OF CONCRETE
FOUNDATION TO
BE LEVEL WITH
TOP OF SIDEWALK
OR CURB,
_= 11= 1111 -1111
II 4
1
-PVC CONDUIT
SYSTEM
CONCRETE
FOUNDATION
3' SQ. OR DIA.
TYPICAL LIGHTING
UNDERGROUND SYSTEM
o/ p
d \ Qv a 0 0 v epo O 0p
o
/ v vQ o av
O O � o A4 Lo ev4
z ei
so e � a �
I o vp o p m 0 3'
� 0 0 n o/ J
� po pn
/ e to At e
a av o v av a O a
STREET LIGHT POLE JUNCTION BOX
PLAN VIEW
�vQ allI IIIv
O
II o
I I vo
e e I I e e
�v0 e
ovA —�
0 oe �
1'
pa o 0 4' DEEP
n
oe a °o
Fl
J
5/8'x8'
COPPER -CLAD
GROUND ROD-
=III °1111 =III
1111 - 1111 - 1111 =1111 II
IIII_ II
— GUN II
TO LUMINAIRE
1/4" MINIMUM
DRAIN HOLE
TOP OF CONCRETE
FOUNDATION TO
BE LEVEL WITH
TOP OF SIDEWALK
OR CURB,
_= 11= 1111 -1111
II 4
1
-PVC CONDUIT
SYSTEM
CONCRETE
FOUNDATION
3' SQ. OR DIA.
TYPICAL LIGHTING
UNDERGROUND SYSTEM
o/ p
d \ Qv a 0 0 v epo O 0p
o
/ v vQ o av
O O � o A4 Lo ev4
z ei
so e � a �
I o vp o p m 0 3'
� 0 0 n o/ J
� po pn
/ e to At e
a av o v av a O a
STREET LIGHT POLE JUNCTION BOX
PLAN VIEW
�vQ allI IIIv
O
II o
I I vo
e e I I e e
�v0 e
ovA —�
0 oe �
1'
pa o 0 4' DEEP
n
oe a °o
Fl
SIDE VIEW
LIGHTING STANDARD & JUNCTI ❑N BOX
ov oa o � poov o
o p v
o a O vp
a e L e 4
a z p
XXX
A pe0
d J 00
NOTE: CLASS 'B' CONCRETE o p o e ,
TO BE USED IN 1
O a o av v v a
CONSTRUCTION OF PAD
1'
PLAN VIEW
INDIVIDUAL JUNCTION BOX
SEE CABINET DETAILS
ON SHEET 14
•r
•
2' N.P.S. SLIPFITTER
SINGLE OR DOUBLE MAST
ARM AS REQUIRED
L��I
2' BY 3/4" REDUCING WASHER
3/4' ROMEX CONNECTOR
WITH LOCKNUT
'-FOR DOUBLE MAST ARM, INSTALL 2ND CABLE
BETWEEN LUMINAIRES WHEN BOTH LUMINAIRES
ARE ON SAME CIRCUIT
LAAf T AMhA ITnTAir T%r— T w TI
ranVV rTl
0.188 WALL BRACKET
ALUM. ALLOY 6063 -T6
112' BNC LOCKBOLT
GR. 18 -8 S.S.
FLUSH JOINT -
4 -112' O.D.
TAPERED ALUM. POLE
0.188 WALL ALLOY 6063 -T6
SATIN GROUND FINISH
151 HANDHOLE. 4'x6" OPENING
W /COVER AND S.S. SCREWS
BASE FLANGE ALLOY 356 -T6 WITH
BOLT COVERS & S.S. SCREWS
--r►i k --11 -1 / 4' SO.
ROLL .2.0 2
4- 1/2'Xt6'GAL VAN[ZED
ANCHOR BOLTS
GIALI CONDUIT ENTR. A A
q o a D o v o
� Q � D A F�70�
a � � 4
PLAN VIEW
SIZE TO FIT CABINET SIZE TO FIT CABINET
FRONT VIEW SIDE VIEW
CAB/NE T FOUNDA TION
SIZE AS REQUIRED
8�
4 -1/2'
N O.D. 2' N.P.S.
SLIPFITTEP
5' -9' RADIUS
11' TO 12' DIA.
BOLT CIRCLE
4' CONCRETE PAD 4 112' OF BOLT ABOVE
FINISHED GRADE
(4) L' BNC GAL V. STEEL
ANCHOR BELTS WITH
NUTS AND WASHERS 4'
4'
STANDARD 25 DA V! T POLE
BIER
14,41-2'
L:
CTORIZED 2• -2
y`
IC GOLD 121 3
(HITE LEGEND
LACK
GROUND
SYSTEM
T 32 5902
u ljC
SC;�I�I�IMED MAY 112006 loo' 3 Zs�o 2
r
T
►"►
.0"
r�
y
a
a
x
N a
o
o �
w �
1
w
N