Loading...
HomeMy WebLinkAboutT-326501V e 0 G Y a w- M f Q W X I N J r I 0 Z Z � Z F— C) �0 'Q Z W Cr QL 0 LL �;7 Cn 0 o -` 0 LLj CJry � . Q, .0 m Cn 4 F o s� a .. Z 0 ac z PORTION OF THE N.W. 1/4 OF SEC. 14, TWN 23 N., RGE 5 E., W.M. i CITY OF RENTON, WASHINGTON 0 MATCH LINE SEE SHEET IL2 CONSTRUCTION NOTES O INSTALL CONCRETE FOUNDATION, LIGHT STANDARD AND LUMINAIRE PER POLE SCHEDULE. 2 INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD. 3 ROUTE CONDUIT AND CONDUCTORS TO EXISTING JUNCTION BOX. SPLICE CONDUCTORS TO EXISTING CIRCUIT "C" CONDUCTORS. VERIFY EXISTING CONDUCTORS. INSTAL. NEW CONDUCTORS IN EXISTING CONDUIT TO SERVICE IF REQUIRED. 4 ROUTE CONDUIT AND CONDUCTORS TO EXISTING JUNCTION BOX. SPLICE CONDUCTORS TO EXISTING CIRCUIT "D ". 1. I OLL 2 0.2 CAUTION: LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND MAY NOT BE ACCURATE OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO POTHOLE AS REQUIRED AND FIELD VERIFY LOCATION OF UTILITIES PRIOR TO PROCEEDING WITH CONSTRUCTION. LI NDERC3RE I ND UTILITY NDTE: YOU MUST CALL 1-800-424-5555 NOT LESS THAN 72 HOURS BEFORE BEGINNING EXCA VA RON WHERE ANY UNDERGROUND UTILI TIES MA Y BE LOCH TED. FAILURE TO DO SO COULD MEAN BEARING SUBS TAN TIAL REPAIR COSTS (UP TO THREE TIMES THE COST OF REPAIRS TO THE SERVICE). Fl;t 0 15� LUMINAIRE SCHEDULE LUM. NO. POLE ID. NO. CIRCUIT N0. LOCATION I OFFSET (FEET) LAMP WATTAGE MAST ARM (FEET) MOUNTING HGT. (FT.) 1 4626B C NE 2ND ST 15 +33 22.5' RT. 100 8' 25' 2 4628B C NE 2ND ST 17 +17 22.5' RT. 100 8' 25' 3 4630B C NE 2ND ST 18 +92 22.5' RT. 100 8' 25' 4 4632B C NE 2ND ST 20 +64 22.5' RT. 100 8' 25 5 46378 C I ELMA PL NE 12 +27 22.5' LT. 100 8' 25' 6 46348 C ELMA PL NE 11+19 22.5 RT. 100 8' 25' 7 4636B C NE 1ST CT 9 +59 22.5' RT. 100 8' 25' 8 4638B C NE 1ST CT 7 +60 22.5' RT. 100 8' 25' 9 4640B C NE 1ST CT 5 +86 22.5' RT. 100 80 25' 10 46428 C ELMA AVE NE 3 +40 22.5 LT. 100 8' 25' 11 4644B C ELMA AVE NE 1+88 22.5' LT. 100 8' 25' 12 4639B C NE 1ST PL 2 +16 22.5 LT. 100 8' 25' 13 4646B D NE 1ST PL 0 +43 22.5' RT. 100 8' 25' WIRING SCHEDULE CONDUIT RUN CONDUIT SIZE CONDUCTORS NOTES 1 1.5" PVC (SCHEDULE 40) 2 — #69 1-- #6 GREEN 2 1.5 PVC SCHEDULE 80)12—#61 1-- #6 GREEN 3 1.5 PVC SCHEDULE 80 2 — #6, 1 — #6 GREEN EXISTING 4 1.5 PVC SCHEDULE 80 2 —##6, 1 — #6 GREEN EXISTING 5 1.5 PVC SCHEDULE 80 4 — #6, 1 — #6 GREEN EXISTING 6 2 11 PVC SCHEDULE 40 6 — #69 1 — #6 GREEN EXISTING 7 1.5 71 PVC 7SCHEDULE 40 2 — #6, 3—#14 1 — #6 GREEN PHOTOCELL EXISTING EXISTING NEW LEGEND TYPE M —C —III H.P.S. LUMINAIRE, ARM AND ALUMINUM DAVIT STYLE POLE ® CONCRETE PAD LIGHT BASE AND ZM "'J" TYPE 1 JUNCTION BOX PVC CONDUIT (SEE WIRING SCHEDULE) k ® TYPE 1 JUNCTION BOX WITH CONCRETE PAD D O WIRE NOTE CONSTRUCTION NOTE T 3250/ 40 0 40 80 scale feet RECOMMENDED FOR APPROVAL BY BY BY CHECKED FOR COMPLIANCE CITY STANDARDS DATE JL2R 106 DATE DATE ra NORTHWEST TRAFrIC EXPERTS 90104 -111th Ave. N.E., Kirkland, WA 98033 Phone: 425.522.4118 Fax: 425.522.4311 NA! WA IT 251 Fs � �, S TERE�G� NAL s.- EXPRES: 9/15/06 CD y'= 3 2 `501 SC W4Q MAY 1 11006 mi M 4 y y C C x CD L tri N y