HomeMy WebLinkAboutT-332502FUSE KITS
XQUICK DISCONNECT
I.00 - 10 AMP IN LINE FUSE TO LUMINAIRE
x g KITS - S.E.C. OR EQUAL
x \ 2' N.P.S. SLiPFITTER
x TYPICAL DESIGN 'B°
JUNCTION BOX
x
1/4° MINIP1UM BRACKET CABLE
SPLICE KITS GROUND LUG DRAIN HOLE
CLEAR EPDXY SPLICE
KITS ON ALL THRU ?° BY 3/4 REDUCING WASHER
V) WIRE RUNS 2' MIN. GROUT VFOUNDATION OP OF CONCRETE
_ UNDER POLE BASE TO
Q C/) CONCRETE E LEVEL WITH 3/4' ROMEX CONNECTOR
J PAD WITH LOCKNUT
OP OF SIDEWALK SINGLE OR DOUBLE MAST r Q 5" 9, R CURB. 3/4'
ARM AS REQUIRED i
c� 0 1111= =1111 =1111-
LLJ cr-
O z z —1111 — III —1111 c° °O = IIII —IIiI =III = I -_ ii- 1111 -1111 FOR DOUBLE MAST ARM, INSTALL 2ND CABLE
= O
COPPER e� ° 111- 1111- 1111 -1111 BETWEEN LUMINAIRES WHEN BOTH LUMINAIRES
COPPED WIRE o "° 1111= ARE ON SAME CIRCUIT
J U
LLJ
W Z_ GROULAMP ND
C
zo U 0 4 MAST ARM WIRING DETAIL
~ PVC CONDUIT
> 2- (SIZED AS TEQ'ID SYSTEM
LIGHTING SYSTEM
WIRES TO CONTACTOR
CONCRETE
N FOUNDATION
M 5/8'x8' I _�
o COPPER -CLAD 3' SO. OR DIA.
M a a o GROUND ROD EPDXY FILL EPDXY FILL
cc CC
Ila K.
x V Y TYPICAL LIGHTING INLINE SPLICE
a WYE SPLICE
UNDERGROUND SYSTEM
SPLICE KIT
Q ®
�7'
o 1
a o
I o ov o 00 000 0 DIAMETER = 7/8°
. Da v
o ' DEEP o
4-7/8' 4
O
3'
D o D eo LOAD LINE
0 ovol
e
FUSE 1/4"
57 z
I
7
0
o Do
O pv v o0 o Oe
STREET LIGHT POLE JUNCTION BOX ° °e o° e o CUTTING RINGS
PLAN VIEW SIDE VIEW FUSE KIT
LIGHTING STANDARD & JUNCTI ❑N B ❑X
D °
NOTE CLASS 'B' CONCRETE D D
r
TO BE USED IN a d° J o o E
CONSTRUCTION OF PAD a m o
O o 0 ov v v E
3/8 "X2" LONG PIN HEX
_ 1/2" DIA HOLES SECURITY SCREW SS (TYP)
1 AND COUNTERSINK
JUNCTION BOX DIMENSION TABLE PLAN VIEW
1/4
A
R ITEM
K
BOX TYPE
TYPE 1
ALTERNATE A ALTERNATE B
-TYPE 2
A Box Outside length
22"
22"
33"
B Box Outside Width
17"
17"
22 1/2-
C Box inside Len th
18"
19"
28"
D Box Inside Width
13"
14"
17"
E Lid Length
18"
18"
26 1/2"
F Lid Width
13"
13"
17"
G Box Depth
12"
12"
1 12"
H Lid & Frame De th
5 16"
5 16"
5/16"
J Wall Thickness Min.
1 1/2 "
1 1 2 "'
1 1 2"
K Wire Reinforcement
W -3
W -2.5 1
W -.5
2
L Legend I
See Detail
See Detail
See Detail
ITEM MATERIALS
Box 6000 PSI concrete See Notes
• Frame Diamond Plate Steel - A786
• Lid Support 1 8 °Min. Thick Steel C, L or L - A36
• Lid Diamond Plate Steel - A786
Anchors Steel Wire or Tee Plate
Reinforcement I ASTM A -82 Steel
*GALVANIZED, STEEL
c
f I I K
H
ELEVATION VIEW
3"
2 `� off DUff__"� M
MIN
Wp
6" GRAVEL PAD
COMPACTED
TYPICAL JUNCTION BOX INSTALLATION DETAILS
JUNCTION BOX DETAILS
GALVANIZED STEEL
BAR 1" WIDE
1/2" THICK
DRILL & THREAD
FOR 3/8" DIA BOLTS
HAND HOLE LOCKING DEVICE
TYPE I AND ll
SIZE AS REQUIRED
01188 WALL BRACKET
ALUM. ALLOY 6063 -TG
4 -1/2' 2" N.P.S.
O.D.
SLIPFITTER
112' BNC LOCKBOLT 5' -9" RADIUS
GR. 18 -8 S.S. \-1-
FLUSH JOINT
4 -1/2' O.D.
TAPERED ALUM. POLE
0.188 WALL ALLOY 6063 -T6
SATIN GROUND FINISH
H
SL
151 HANDHOLE. 4'x6` OPENING
W /COVER AND S.S. SCREWS 8' O.D.
BASE FLANGE ALLOY 356 -T6 WITH - GROUND LU
BOLT COVERS & S.S. SCREWS 1'-6'
1-11 -1/4" SQ,
11' TO 12" DIA.
BOLT CIRCLE
4" CONCRETE PAD 4 112' OF BOLT ABOVE
FINISHED GRADE
(4) l' BNC GALV. STEEL
ANCHOR BOLTS WITH
NUTS AND WASHERS 4,'
4" °
STANDARD DA VI T POLE
INSTALL DECAL NUMBERS
VERTICALLY.. INSTALL
IN DRY WEATHER 50 °F
OR ABOVE. NUMBERING EXAMPLES
DECAL NUMBERING SYSTEM
2°
T- 332��2
RECOMMENDED
LETTER LETTER
FOR APPROVAL
SUFFIXED PREFIXED
BY
DATE
CITY PUGET POWER
OWNED OWNED
BY
DATE
CURB
MOUNTINGOF,
DATE
90001 SITE
HEIGHT
BY
Cq�
15 FEET
BY
DATE
45
TRAFFIC DECAL1
FLOW RELECTORIZED
GOTHIC GOLD
LIGH
OR WHITE LEGEND
-
ON LACK
PLAN VIEW BACKGROUND
DECAL NUMBERING SYSTEM
2°
T- 332��2
RECOMMENDED
FOR APPROVAL
BY
DATE
BY
DATE
BY
DATE
90001 SITE
BY
DATE
15';
BY
DATE
LIGH
-
cD:T- 3525D2 JUts 4 x aul