CONSTRUCTION NOTES
INSTALL COBRA HEAD LUMINAIRE ON LUMINAIRE POLE PER THE POLE
SCHEDULE THIS SHEET, AND CITY OF RENTON STANDARD PLANS, SHEETS
IL4 AND IL5. TOP OF FOUNDATION SHALL BE FLUSH WITH TOP OF
SIDEWALK. THE POLE SHALL MEET ALL REQUIREMENTS OF A CITY OF
RENTON STANDARD ALUMINUM DAVIT POLE.
0 2 2 INSTALL CITY OF RENTON STANDARD SERVICE CABINET, PER CITY OF
RENTON STANDARDS (SEE SHEET IL4). 1201240Y POWER SOURCE TO BE
PROVIDED BY PUGET SOUND ENERGY. TRENCH AND PROVIDE CONDUIT
AND CONDUCTORS TO PUGET SOUND ENERGY POWER SOURCE. LOCATION
SHOWN IS APPROXIMATE, ACTUAL POWER SOURCE LOCATION MAY VARY.
THE CONTRACTOR SHALL COORDINATE POWER SOURCE LOCATION WITH PSE.
CABINET ID = #0114
ILLUMINATION LEGEND
®
TYPE 1 JUNCTION BOX
®
TYPE 2 JUNCTION BOX
�-
LUMINAIRE POLE
- - - --
CONDUIT /CONDUCTOR
®
ELECTRICAL SERVICE CABINET
OCONSTRUCTION
NOTE
POLE NO.
LUMINAIRE POLE NUMBER
AWIRE
NOTE
GENERAL NOTES
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE
STANDARDS AND SPECIFICAT IONS OF THE CITY OF RENTON UTILITY
DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA
STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL
BE KEPT ON -SITE AT ALL TIMES DURING CONSTRUCTION.
2. THE HOURS OF WORK IN THE STREET RIGHT -OF -WAY SHALL BE
LIMITED TO 8 :30 AM TO 3 :30 P.M. ON WEEKDAYS UNLESS OTHERWISE
APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS AT
235 -2635. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE
APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN
ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911
SHALL BE NOTIFIED 24 HOURS IN ADVANCE.
3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE
AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY
THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
DISTURBANCE. FOR UTILITY LOCATE CALL 48 -HOUR LOCATORS,
1- 800 - 424 -5555.
4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE
REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY
PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE
ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE
UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL
CONSTRUCTION.
5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND
SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND
OTHERS ON THE CONSTRUCTION SITE.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN
STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY
CONSTRUCTION.
7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS.
8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE
WHENEVER CONSTRUCTION IS IN PROGRESS.
9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO
95% MAXIMUM DRY DENSITY MODIFIED PROCTOR.
10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE
SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL AT THE
EARLIEST POSSIBLE DATE.
W
ILLUMINATION POLE SCHEDULE
LUM.
20 60
SCALE: 1 " =20'
T ww'm
5 Sftd2
POLE
MOUNTING
ARM
pp7 T
mac, •; ...AS
CITY OF RENTON
POLE NO.
ROAD
STATION
OFFSET
HEIGHT
LENGTH
CIRCUIT
WATTAGE
PHOTOMETRICS
COMMENT
LUMINAIRE ID
1
NE 23RD PLACE
34 +50.0
30.0' RT
25'
8'
A
100W
FLAT LENS
M -C -111
4970B
2
NE 23RD PLACE
35+77.0
22.0' LT
25'
8'
A
100W
FLAT LENS
M -C -Ill
4975B
3
NE 23RD PLACE
37 +51.0
22.0' LT
25'
8'
A
100W
FLAT LENS
M -C -III
INSTALL PHOTOCELL
4977B
4
NE 25TH COURT
1 +98.0
50.5' LT
25'
8'
A
100W
FLAT LENS
M -C -Ill
49858
5
NE 25TH COURT
1 +95.0
50.0' RT
25'
8'
A
t00W
FLAT LENS
M -C -111
4986B
6
NE 23RD PLACE
39 +38.5
22.0' RT
25'
8'
A
100W
FLAT LENS
M -C -ill
49808
7
NE 23RD PLACE
41 +01.5
22.0' RT
25'
8'
A
iDOW
FLAT LENS
M -C -111
49749
8
NE 25TH COURT
3 +58.0
24.0' RT
25'
8'
A
100W
FLAT LENS
M -C -111
48818
9
NE 25TH COURT
5 +05.0
24.0' LT
25'
8'
A
100W
FLAT LENS
M -C -111
49839
10
NE 25TH COURT
6 +75.5
24.0' LT
25'
8'
A
100W
FLAT LENS
M -C -111
49798
11
NE 25TH COURT
7 +28.0
83.0' RT
25'
8'
A
100W
FLAT LENS
M -C -111
49788
12
128TH AVENUE SE
11 +36.5
24.0' LT
25'
8'
A
f00W
FLAT LENS
M -C -111
49878
ILLUMINATION WIRE SCHEDULE
L, RACEWAY EQUIP.
CONDUIT ILLUM GROUND PHOTOCELL POWER
NO SIZE 8 #8 #14 #2
1 2" SCH40 2 1
2 2" SCH80 2 1 N
3 2" SCH40 EMPTY SPARE WITH PULL ROPE
4 2" SCH40 2 1 3
5 2" SCH40 1 3
W
0 I
.i-
CD-v- -53S(603 maim
10 40
0
20 60
SCALE: 1 " =20'
T ww'm
5 Sftd2
pp7 T
mac, •; ...AS
CHECK FOR COMPLIANCE
TO CITY STANDARDS
TRANSPORTATION ENGINEERING NORTHWEST, LLC
816 SIXTH STREET SOUTH
KIRKLAND, WA 98033
��S.�F ° hti•.F,�y
.W S
�, B/,
4 DATE'/
PHONE: (425) 806 -9236
�:�
0; PF
DATE �,
FAX: (360) 668-1133
S c• -•• ��
;aNAI-
DATE
CONTACT: CHRIS BICKET, P.E.
�a�ei �e
EXPIRES 12/20/07` i
r�
-
0 I
.i-
CD-v- -53S(603 maim