Loading...
HomeMy WebLinkAboutT-3376039 a 3 0 J wo�W� J Z Z (n O F- C9 Z Q � J __J FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS - S.E.C. OR EQUAL - TYPICAL DESIGN "B" JUNCTION BOX SPLICE KITS GROUND LU CLEAR EPDXY SPLICE KITS ON ALL THRU 2" MIN. GROUT WIRE RUNS UNDER POLE 4" CONCRETE BASE PAD -\ _.7T_T- #8 BARE COPPER GROUND WIRE 1 - #8 GREEN 2- (SIZED AS REQ'D) LIGHTING SYSTEM WIRES TO CONTACTOR 0 5/8 "x8' o COPPER -CLAD Z Y DATE GROUND ROD - O F-1 U W � F.y NN o_ W � c a m' NOTES:. All dimensions are. minimum. Exact configurations vary among. different manufacturers. Th e noted lid are overall minimums The Diamond Pattern for Type 1 or Type 2 EPDXY FILL EPDXY FILL Boxes shall be 28% minimum of overall thickness. .Lid support members shall . be welded to the frame. 490OPSI. concrete is allowed if box reinforcement consists of 6 X 6 - W3 X W3 welded wire fabric welded to the frame. When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12" deep INLINE SPLICE extension boxes. When noted in the contract. Type Boxes shall be provided with a 10' X 27 1/2" 10 WYE SPLICE gage divider plate complete with fasteners. Non-concrete Boxes may be submitted for approval. Evaluation will include an H -20 I III SPLICE KIT Load Test. I� I TO LUMINAIRE JUNCTION BOX DIMENSION TABLE 1 r c I 1/4" MINIMUM -DRAIN HOLE TOP OF CONCRETE FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. DIAMETER 7/8" _ _= II -1111 -1111 ITEM BOX TYPE TYPE1 ALTERNATE A ALTERNATE B TYPE 2 A Box Outside len th 22" 1 22" 1 33" B Box Outside: Width a a 17" la x C Box Inside Length 18" 19 ° D Box .Inside Width 13" 14" 17" E Lid Length m 18" 26 1/2" F Lid Width 13" 13 ". 17" ULjox ue th 12" 0 of of 12" H &Frame De th 5 16" 5 16" 5 16" Thickness Min. 1 1 2" 1 1 2" O Z Reinforcement � end See Detail NOTES:. All dimensions are. minimum. Exact configurations vary among. different manufacturers. Th e noted lid are overall minimums The Diamond Pattern for Type 1 or Type 2 EPDXY FILL EPDXY FILL Boxes shall be 28% minimum of overall thickness. .Lid support members shall . be welded to the frame. 490OPSI. concrete is allowed if box reinforcement consists of 6 X 6 - W3 X W3 welded wire fabric welded to the frame. When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12" deep INLINE SPLICE extension boxes. When noted in the contract. Type Boxes shall be provided with a 10' X 27 1/2" 10 WYE SPLICE gage divider plate complete with fasteners. Non-concrete Boxes may be submitted for approval. Evaluation will include an H -20 I III SPLICE KIT Load Test. I� I TO LUMINAIRE JUNCTION BOX DIMENSION TABLE 1 r c I 1/4" MINIMUM -DRAIN HOLE TOP OF CONCRETE FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. DIAMETER 7/8" _ _= II -1111 -1111 ITEM BOX TYPE TYPE1 ALTERNATE A ALTERNATE B TYPE 2 A Box Outside len th 22" 1 22" 1 33" B Box Outside: Width 17" 17" 12 2 17_2" C Box Inside Length 18" 19 1 28" D Box .Inside Width 13" 14" 17" E Lid Length 18" 18" 26 1/2" F Lid Width 13" 13 ". 17" ULjox ue th 12" 12" 12" H &Frame De th 5 16" 5 16" 5 16" Thickness Min. 1 1 2" 1 1 2" 1 1 2 Reinforcement end See Detail See Detail See Detail IIIIE 4-7/8' - h D ELEVATION VIEW LOAD LINE ITEM MATERIALS 4 FUSE ' 1 �4 1 �4" Box 6000 PSI concrete See Notes UIT • Frame Diamond Plate Steel - A786 f 1 /g" �8" *Lid Su ort 1 6'Min. Thick Sted C L or T. - A36 Ir • Lid Dimond Plate Steel- A786 „P N 6'GRAVEL PAD CUTTING RINGS Anchors Steel Wire or Tee Plate COMPACTED 3' SQ. Reinforcement ASTM A 82 Steel OR DIA. *GALVANIZED STEEL TYPICAL JUNCTION BOX INSTALLATION DETAILS BOX FUSE KIT m TYPE T' LEGEND DETAIL (Mark U Ti li"°°i 0 TYPE '11' Box TYPICAL SIGNALS 1 �a��na „mr LIGHTING HOOK OEfAIL PLAN SYMBOLB LIGHTING u.,,�.o -an UNDERGROUND - TELEMETRY NOTE: INSTALL HMDH E OR sIWMI LOOKING TRAFFIC SIGNAL SYSTEM LEGEND TYPE T HANDHq.,E R MIU LOCKING SYSTEM - FUSE KIT & SPLICE KIT DETAILS SECURIW SC 3/6• PIN HEX DEMM Y SCREMS BOX DETAILS ADOPTED ADOPTED -Farm L tt ith 1 /B" Weld CITY OF ERENTON CITY OF BENTON CITY OF RENTON Bead G i d ff Diamond Pattern Standard pleas Standard plans letters b fore form n9 r Standard plans ISr DATE: 12/96. .� EST DATE: 11/5/96ILLUMINA110N SYSTEM LEGEND LST DATE: 11/89 DWG. NAME: JR -06 SP PAGE: J007 DWG. NAME: JR 12 SP PAGE: J013 DATE REVISION BY APPR DWG. NAME: JR -36 SP PAGE: JO 16 DATE REVISION BY APPR METER 1 BASE MAIN - 20A LIGHTING A 2OA LIGHTING B 20A LIGHTING C .. GROUND BAR 0 0 loo 01 [.YI TO PHOTO CELL j 15A TEST SWITCH 50A SIGNAL 20A .. LIGHTING D BREAKER SCHEDULE SERVICE VOLTAGE: 120 -240 BUS RATING ZW AMP LOCATION MOUNRN(t BUS CONNECTION: 2'P 3 W DRAWING - CIIRCUIT VOI.TAMPB BREAKER CKT CONNECTION T BREAKER VOLTAMPS CURWIT OESCRIPRON A B pMP. POLE N0: A B NO.IAMP POLE B OEBCRIPRON NOTES: 49. 225 AMP COPPER BUSSING 18 PLC PANNEL 50. C.H. 2P '100 AMP MAIN (BAB2100) CONTRACTOR IS RESPONSIBLE G 51. C.H. 2P 20 AMP BREAKER (BAB2020) TO VERIFY METER F 52. C.H. 1P 50 AMP BREAKER (BAB1050) ARRANGEMENT 1 53, C.H. 1P 20 AMP BREAKER (BAB1020) 54. C.H. 1P 15 AMP BREAKER (BAB1015) 55. MILBANK METER ENCLOSURE (MS- 24 -TB) MEETS EUSERC REQUIREMENTS 56. HUBBELL SWITCH (CS1201 -1) APPROVED BY: 57. GFC1. RECEPTACLE 20 AMP (LEVITON 6898 -1) PUGET SOUND ENERGY 58. SQUARE D LIGHTING CONTACTOR TACOMA POWER (981ODPA32VO2UI) 61. SOUTHCO DOOR S.S. HINGE (176 -3 -1) 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2 -626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1"X.25" GASKET m 0 m m li I ®o�'I ©O 0 ...��10 TYP , 1600 E�NORTHWEST TRAP -W EXPERTS 10104 -111th Ave. N.E., Kirkland, WA 98033 Phone: 425.522.4118 Fax: 425.522.4311 CAUTION: LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND MAY NOT BE ACCURATE OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO POTHOLE AS REQUIRED AND FIELD VERIFY LOCATION OF UTILITIES PRIOR TO PROCEEDING WITH CONSTRUCTION. YOU MUST CALL 1- 800- 424 -5555 NOT LESS THAN 72 HOURS BEFORE BEGINNING EXCAVATION WHERE ANY UNDERGROUND UTILITIES MAY BE LOCATED. FAILURE TO DO SO COULD MEAN BEARING SUBSTANTIAL REPAIR COSTS (UP TO THREE TIMES THE COST OF REPAIRS TO THE SERVICE) RECOMMENDED FOR APPROVAL BY BY BY CHECKED FOR COMPLIANCE TO CITY STANDARDS DATE DATE DATE NOTES: 49. 225 AMP COPPER BUSSING 18 PLCS PANNEL 50. C.H. 2P 100 AMP MAIN (BAB2100) 51. C.H. 2P 20 AMP BREAKER (BAB2020) 52. C.H. 1P 50 AMP BREAKER (BAB1050) 53. C.H. 1P 20 AMP BREAKER (BAB1020) 54. C.H. 1P 15 AMP BREAKER (BAB1015) 55. MILBANK METER ENCLOSURE (MS- 24 -TB) 56. HUBBELL SWITCH (CS1201 -1) 57. GFCI. RECEPTACLE 20 AMP (LEVITON 6898 -1) 58. SQUARE D LIGHTING CONTACTOR (981 ODPA32VO2U1) 61. SOUTHCO DOOR S.S. HINGE (1­6 -3 -1) 64. STAINLESS STEEL HANDLE 65. DEAD BOLT LOCK "BEST" (5L7RL2 -626) 66. SQUARE D TERMINAL BLOCK 67. SQUARE D END CAP 70. 1"X.25" GASKET CONTRACTOR IS RESPONSIBLE TO VERIFY METER ARRANGEMENT MEETS EUSERC REQUIREMENTS APPROVED BY: PUGET SOUND ENERGY TACOMA POWER :T- 357b0 ..-- %win D L nlLrr � - t F F# �� LL