Loading...
HomeMy WebLinkAboutT-3521053 — # 0 PLAN VIEW COMBINED CONTROLLER BBS /CON TACTOR FOUNDATION PROJECT ENGINEER DESIGNED BY: KJP DRAWN BY: KJP CHECKED BY: JJGU DATE PLATTED: 07/20/10 FILE: IITTTS05RE 7 -7 -10 1RECORD DRAWINGS I KAHA DATE I REVISIONS I APPRVD. NOTES 1. Where foundation pad is located within a sidewalk, construct pad --r I I I top flush with sidewalk grade, omitting chamfer where top and ---� I I I I I I sidewalk abut. Make pad flush with back edge of sidewalk. Mount top shall be finished by a concrete contractor and shall meet the I I I I I I I I 1 I I I I -- -- F - -0_1 -- - - -, requirements of section 8 -14.3 in the WSDOT Standard 24 Specifications. 2. Pad mount design is typical. 3. Place a silicone seal between the foundation and cabinet. 4. Anchor bolts and their spacing to be supplied by cabinet manufacturer and submitted to the engineer for approval. Sidewalk 5. Conduit sizes /quantities for the controller and contactor cabinets shall be installed per the contract plans, plus one 2" spare capped __ __ _ - -J i I I out past the foundation. 6. Concrete shall be Class 3000. 7. 2" conduit shall be placed from the combined BBS /contactor to the controller cabinet. 8. Each cabinet shall have a %" diameter plastic drain pipe. 9. Locate conduits centrally within the cabinets. I I I I I I o i Mastic drain I o > I - - - - - -- Horizontal COMBINED FOUNDATION REINF. BAR DIAGRAM 6 Pieces CONC. CL. u I I n u I I n 18" u n 2 Yz" EXISTING CONDUIT NOTE: SEE WSDOT STD. PLAN J -7A FOR ADDITIONAL DETAILS 24" \—#6 BAR, 8 %" O.C. EACH WAY 48" LUMEC LUMINAIRE TR20 -250 HPS —SG3- 240 -400 OR APPROVED EQUAL U ROADWAY ^.,®-• LUMEC ---/ BRACKET UN -1A OR APPROVED EQUAL 35' STREET LIGHT CONDUIT TRENCH DEPTH 24" POLE 2A FOUNDATION DETAIL PLANS PREPARED BY: City of Renton Department of Public Works AND ASSOCIATES � Q ATES INC. 4% - IM Avenue SE 1055 S. Grady Way Q eelevue Waftoon OW05 -3ft w, 425.50.6500 Renton, Washington 98057 Pho RECORD DRAWING INFORMATION SHOWN ON RECORD DRAWINGS FOR LOCATIONS AND ELEVATIONS OF FEATURES WERE PROVIDED BY THE CITY OF RENTON AND /OR ITS CONSTRUCTION CONTRACTOR. DAVID EVANS AN[ ASSOCIATES INC. ASSUMES NO LIABILITY FOR THI'I ACCURACY OF THIS INFORMATION 3' -7.5" li 22' •- i I �LUMEC POLE 85V- 38 —BKTX 8' OR APPROVED EQUAL ll BOTTOM BANNER SAVER BRACKET ARM ANCHOR BOLT FI BOLT VARIES — {{I / PATTERN SPECIFICATION SHALL CONFORM TO MANUFACTURER TYPICAL STREET LIGHT FOUNDATION PER WSDOT STD. PLAN J- 28.30 -00 T- 352105 0 z.s s SOUTH 3RD ST. AND SHATTUCK AVE SOUTH SHEET TS05 INTERSECTION SAFETY IMPROVEMENTS M 11 OF 11 TRAFFIC SIGNAL PLAN 7-- U.5aWL 10 r - I I I --r I I I -- -r- -� - -- I I I I I I ---� I I I I I I I I I F - I I I I I I I I 1 I I I I -- -- F - -0_1 -- - - -, } 24 I „ g I L___ L__J 1 i __ __ _ - -J i I I I I 1 I I I I I I I I I I I I I I I \—#6 BAR, 8 %" O.C. EACH WAY 48" LUMEC LUMINAIRE TR20 -250 HPS —SG3- 240 -400 OR APPROVED EQUAL U ROADWAY ^.,®-• LUMEC ---/ BRACKET UN -1A OR APPROVED EQUAL 35' STREET LIGHT CONDUIT TRENCH DEPTH 24" POLE 2A FOUNDATION DETAIL PLANS PREPARED BY: City of Renton Department of Public Works AND ASSOCIATES � Q ATES INC. 4% - IM Avenue SE 1055 S. Grady Way Q eelevue Waftoon OW05 -3ft w, 425.50.6500 Renton, Washington 98057 Pho RECORD DRAWING INFORMATION SHOWN ON RECORD DRAWINGS FOR LOCATIONS AND ELEVATIONS OF FEATURES WERE PROVIDED BY THE CITY OF RENTON AND /OR ITS CONSTRUCTION CONTRACTOR. DAVID EVANS AN[ ASSOCIATES INC. ASSUMES NO LIABILITY FOR THI'I ACCURACY OF THIS INFORMATION 3' -7.5" li 22' •- i I �LUMEC POLE 85V- 38 —BKTX 8' OR APPROVED EQUAL ll BOTTOM BANNER SAVER BRACKET ARM ANCHOR BOLT FI BOLT VARIES — {{I / PATTERN SPECIFICATION SHALL CONFORM TO MANUFACTURER TYPICAL STREET LIGHT FOUNDATION PER WSDOT STD. PLAN J- 28.30 -00 T- 352105 0 z.s s SOUTH 3RD ST. AND SHATTUCK AVE SOUTH SHEET TS05 INTERSECTION SAFETY IMPROVEMENTS M 11 OF 11 TRAFFIC SIGNAL PLAN 7-- U.5aWL 10