HomeMy WebLinkAboutT-364002Z HF
W Z
O LLI
U
a
_Z
Z
LL.I
J
0
O
J
J
rr
LU
N/
\ , S4 \
AL6 i
' 11+00
- JJE ST - - ----AL6
�o
777777F��
-T\ ?i
1 i
1
l S'4ER the '�
- A
706'
VL
I
4 Cu F) 3105
B�2ASSS S Ikl PU .C'A
NEL
Ag�� �� —I C Y"' C-INC4 T 9N6iY-
I SEI IN '1SE
R/ 6 03 F.rt. ALCW.. "�'�
I ?flSl N
N1379 %B 3893
r�
\-S2 O
AL-6__
\,\
\
\
S1 \
/ \ AL6
_.. uo NPNHULE
ILLUMINATION POLE SCHEDULE
LUMINAIRE
POLE NO.
ROAD
STATION
POLE
OFFSET
MOUNTING
HEIGHT
GIRCUIT
WATTAGE
CITY OF RENTON
LUMINAIRE I.D. NO.
SL1
NE. 16th STREET
13 +16.78
18.00' LT
14.00'
1
48W LED
8011M -
SL2
NE. 16th STREET
12 +10.88
12.00' LT
14.00'
1
48W LED
8013M
SL3
NE. 16th STREET
11 +03.97
12.00' LT
14.00'
1
48W LED
8015M
SL4
INDEX AVENUE NE.
20 +34.19
15.08'RT
14.00'
1
48W LED
8017M
SL5
INDEX AVENUE NE.
21 +44.63
15.08' RT
14.00'
1
48W LED
8019M
SL6
INDEX AVENUE NE.
22 +56.88
15.08' RT
14.00'
1
48W LED
8021M
SL7
INDEX AVENUE NE.
23 +68.15
15.08' RT
14.00'
1
48W LED
8023M
SL8
HARRINGTON AVENUE NE.
'30 +30.34
22.00' RT
14.00'
1
48W LED
8024M
SL9
HARRINGTON AVENUE NE.
31 +49.65
18.00' RT
14.00'
1
48W LED
8026M
SLI0
HARRINGTON AVENUE NE.
32 +57.54
18.00' RT
14.00'
1
48W LED
8028M
SL11
HARRINGTON AVENUE NE.
33 +65.43
18.00' RT
14.00'
1
48W LED
8030M
SL12
HARRINGTON AVENUE NE.
34+75.05
18.00' RT
14.00'
1
48W LED
8032M
SL13
HARRINGTON AVENUE NE.
1 35 +92.31
18.00' RT
14.00'
1
48W LED
8034M
SLi4
HARRINGTON AVENUE NE.
1 37 +00.00
1 18.00' RT
14.00'
1
48W LED
8036M
-
lg ,
I(l '
ILLUMINATION LEGEND=
DECORATIVE AREA L.E.D. LIGHT (AL6) Q
STREET UGHTING SERVICE CABINET ❑
2" STREET LIGHTING CONDUIT — — — —
« wmi
N e
atY
'WA141 c
s
GRAPHIC SCALE
0 10 20 40 FEET
1" = 20 FEET
CONSTRUCTION KEY NOTESi
OINSTALL DECORATIVE LUMINAIRE PER THE POLE SCHEDULE ON
SHEETS C2.32 -C2.34 AND CITY OF RENTON STANDARD DETAILS PER
SHEET C8.6A. TOP OF FOUNDATION SHALL BE FLUSH WITH TOP OF
SIDEWALK.
OPROVIDE NEW UNDERGROUND STREET LIGHTING CIRCUIT, 2 "C. (3)
JBCU, INCLUDE ALL TRENCHING, SANDBEDDING, BACKRLL,
COMPACTION AND HANDHOLES AT THE BASE OF EACH POLE PER
CITY OF RENTON STANDARDS. SEE DETAIL SHEET C8.6A.
OEXTEND 2 "0, WITH (3) #2 CU FROM TOP OF EXISTING UTILITY POLE
ON NORTH SIDE OF HARRINGTON AVENUE NORTHEAST TO STREET
LIGHTING CABINET. PROVIDE SPLICE AT TOP OF POLE AND TERMINATE
AT SERVICE CABINET AS REQUIRED. COORDINATE ALL WORK WITH
CITY OF RENTON AND PUGET SOUND ENERGY (PSE), SEE DETAILS ON
SHEET C8.6A.
OPROVIDE AND INSTALL NEW STREET UGHTING CABINET ON 4"
CONCRETE PAD. COORDINATE ALL WORK WITH CITY OF RENTON AND
PUGET SOUND ENERGY (PSE), SEE DETAILS ON SHEET C8.6A
Checked for Compliance to City Standards
Civil Engineers
� z
L, w� Structural Engineew + - .....ANN04
t1� '
<A� «F wa=g Zq� ndscape Amhifeots - �J,V'J'-{ a'� IN
y 'tt'' Community Planners
' 6666 '`<•"� {�' � Er�� w �:-, �, 111 'N 0ONAL 0GN
Tm3 64002 9 °612 ��& Qr 16Min TACOMA • S.EATTLE
C �� � ♦ NO CE
ArN� ' IIRAr� xn w v° ,°40A°q« u 2215 North 30th Street, Suite 300, Tacoma, WA 98403
' a'" itmm�OAO "aa°rs� «a°f,°'A0G1oorivon01s 253.383.2422 TEL
°uaseo` roan «"'a �m01 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101
A°p1010"HiPP6"'�iPAYtOTFAP1°"`' 206267.2425 TEL
sumcieo scvc Dire
N R Rm
AS NOTED CITY OF EARLY CHILDHOOD LEARNING CENTER 6 -22 -2012
xwaxartw xw rem /{RR{ ii ,i
B. MALONEY RENTON SCHOOL DISTRICT ""°�°°"'
�•«: PENTON R
E. WRZSKI ' a E nrx ' DATUM C2.32
e. MALONEY "T Planning /Building /Public works Deft. OFFSITE ILLUMINATION PLAN
IF HOr qE RCN
REVISION BY DATE APPR =L"�y
M. COZART 45 a 56
c) ;-r= 36gt�r��' A— �INNN AP