Loading...
HomeMy WebLinkAboutT-364002Z HF W Z O LLI U a _Z Z LL.I J 0 O J J rr LU N/ \ , S4 \ AL6 i ' 11+00 - JJE ST - - ----AL6 �o 777777F�� -T\ ?i 1 i 1 l S'4ER the '� - A 706' VL I 4 Cu F) 3105 B�2ASSS S Ikl PU .C'A NEL Ag�� �� —I C Y"' C-INC4 T 9N6iY- I SEI IN '1SE R/ 6 03 F.rt. ALCW.. "�'� I ?flSl N N1379 %B 3893 r� \-S2 O AL-6__ \,\ \ \ S1 \ / \ AL6 _.. uo NPNHULE ILLUMINATION POLE SCHEDULE LUMINAIRE POLE NO. ROAD STATION POLE OFFSET MOUNTING HEIGHT GIRCUIT WATTAGE CITY OF RENTON LUMINAIRE I.D. NO. SL1 NE. 16th STREET 13 +16.78 18.00' LT 14.00' 1 48W LED 8011M - SL2 NE. 16th STREET 12 +10.88 12.00' LT 14.00' 1 48W LED 8013M SL3 NE. 16th STREET 11 +03.97 12.00' LT 14.00' 1 48W LED 8015M SL4 INDEX AVENUE NE. 20 +34.19 15.08'RT 14.00' 1 48W LED 8017M SL5 INDEX AVENUE NE. 21 +44.63 15.08' RT 14.00' 1 48W LED 8019M SL6 INDEX AVENUE NE. 22 +56.88 15.08' RT 14.00' 1 48W LED 8021M SL7 INDEX AVENUE NE. 23 +68.15 15.08' RT 14.00' 1 48W LED 8023M SL8 HARRINGTON AVENUE NE. '30 +30.34 22.00' RT 14.00' 1 48W LED 8024M SL9 HARRINGTON AVENUE NE. 31 +49.65 18.00' RT 14.00' 1 48W LED 8026M SLI0 HARRINGTON AVENUE NE. 32 +57.54 18.00' RT 14.00' 1 48W LED 8028M SL11 HARRINGTON AVENUE NE. 33 +65.43 18.00' RT 14.00' 1 48W LED 8030M SL12 HARRINGTON AVENUE NE. 34+75.05 18.00' RT 14.00' 1 48W LED 8032M SL13 HARRINGTON AVENUE NE. 1 35 +92.31 18.00' RT 14.00' 1 48W LED 8034M SLi4 HARRINGTON AVENUE NE. 1 37 +00.00 1 18.00' RT 14.00' 1 48W LED 8036M - lg , I(l ' ILLUMINATION LEGEND= DECORATIVE AREA L.E.D. LIGHT (AL6) Q STREET UGHTING SERVICE CABINET ❑ 2" STREET LIGHTING CONDUIT — — — — « wmi N e atY 'WA141 c s GRAPHIC SCALE 0 10 20 40 FEET 1" = 20 FEET CONSTRUCTION KEY NOTESi OINSTALL DECORATIVE LUMINAIRE PER THE POLE SCHEDULE ON SHEETS C2.32 -C2.34 AND CITY OF RENTON STANDARD DETAILS PER SHEET C8.6A. TOP OF FOUNDATION SHALL BE FLUSH WITH TOP OF SIDEWALK. OPROVIDE NEW UNDERGROUND STREET LIGHTING CIRCUIT, 2 "C. (3) JBCU, INCLUDE ALL TRENCHING, SANDBEDDING, BACKRLL, COMPACTION AND HANDHOLES AT THE BASE OF EACH POLE PER CITY OF RENTON STANDARDS. SEE DETAIL SHEET C8.6A. OEXTEND 2 "0, WITH (3) #2 CU FROM TOP OF EXISTING UTILITY POLE ON NORTH SIDE OF HARRINGTON AVENUE NORTHEAST TO STREET LIGHTING CABINET. PROVIDE SPLICE AT TOP OF POLE AND TERMINATE AT SERVICE CABINET AS REQUIRED. COORDINATE ALL WORK WITH CITY OF RENTON AND PUGET SOUND ENERGY (PSE), SEE DETAILS ON SHEET C8.6A. OPROVIDE AND INSTALL NEW STREET UGHTING CABINET ON 4" CONCRETE PAD. COORDINATE ALL WORK WITH CITY OF RENTON AND PUGET SOUND ENERGY (PSE), SEE DETAILS ON SHEET C8.6A Checked for Compliance to City Standards Civil Engineers � z L, w� Structural Engineew + - .....ANN04 t1� ' <A� «F wa=g Zq� ndscape Amhifeots - �J,V'J'-{ a'� IN y 'tt'' Community Planners ' 6666 '`<•"� {�' � Er�� w �:-, �, 111 'N 0ONAL 0GN Tm3 64002 9 °612 ��& Qr 16Min TACOMA • S.EATTLE C �� � ♦ NO CE ArN� ' IIRAr� xn w v° ,°40A°q« u 2215 North 30th Street, Suite 300, Tacoma, WA 98403 ' a'" itmm�OAO "aa°rs� «a°f,°'A0G1oorivon01s 253.383.2422 TEL °uaseo` roan «"'a �m01 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 A°p1010"HiPP6"'�iPAYtOTFAP1°"`' 206267.2425 TEL sumcieo scvc Dire N R Rm AS NOTED CITY OF EARLY CHILDHOOD LEARNING CENTER 6 -22 -2012 xwaxartw xw rem /{RR{ ii ,i B. MALONEY RENTON SCHOOL DISTRICT ""°�°°"' �•«: PENTON R E. WRZSKI ' a E nrx ' DATUM C2.32 e. MALONEY "T Planning /Building /Public works Deft. OFFSITE ILLUMINATION PLAN IF HOr qE RCN REVISION BY DATE APPR =L"�y M. COZART 45 a 56 c) ;-r= 36gt�r��' A— �INNN AP