Loading...
HomeMy WebLinkAboutT-366501M In J J Y 0 O Z Ld Q � Z J 0 r z I- o FY N 0 3 2 1-4 W 0- � � m DOc .O rn c c 0 a 1 o_ a 0 8 z 0 N o: d z POLE ID. NO. CIRCUIT NO. 5 NE 1/4 SECTION 14, TOWNSHIP 23N, RAN IIE 5E, W.M. LED LAMP WATTAGE 1 o_ a 0 8 z 0 N o: d z LUMINAIRE SCHEDULE LUM. NO. POLE ID. NO. CIRCUIT NO. LOCATION NE 1/4 SECTION 14, TOWNSHIP 23N, RAN IIE 5E, W.M. LED LAMP WATTAGE MAST ARM (FEET) MOUNTING HGT. (FT.) STANDARD PLAN # 1 40 N A 156TH AVE SE 70 +91 20.5' RT 44 4 14 40 117.2 2 3 A 156TH AVE SE 72 +17 w 100/44 I N8744'18" 588.50' 117.1 3 PVC (SCHEDULE B NE 1ST ST 10 +68 16.5 RT 44 LED .6'/4' NA 14 11 .1 -_ PSE POWER s - - - -- r--- - - - - -- i r--- - - -___ NE 1ST ST 11 +18 16.5 LT 44 L DI NA 14 I I I I I I I 1 r-- - - -___ B NE 1ST ST 1 778-- EXISTING 250 WA 44 LED 4 14 116.1 LUMINAIRE ON WOOD P NE 1ST ST 12 +23 79. 5 LT 44 LED NA 14 11.6.1 TO REMAIN JI$ NE 1ST ST 12 +96 p I P I I I I I 44 LED NA 14 116.1 8 7 6 i i NE 1ST ST 13 +48 16.5 LT �� NA 14 116.1 5 4 i B NE 1ST ST + 16.5 RT L 1I I i i i i 3 2 i i NE 1ST ST + 16.5. LT i i 1 116.1 NE 1ST ST 15+01 I I I LOT 2 I I 414 L Y 116.1 � � I I � � I I i NE 1ST ST. 15 +38 .16.5 LT 1 EXISTING 150 1YArr� 14 116.1 L - -- __� L - -- I I - - - - - _ _ _ _ J I I I I I I I NE 1ST ST + LUMINAIRE ON WOOD PO ��1fII TO BE REMOVE BY OTHF.�S 44 LED 14 - _ \, - - - - _ - - I I 1 - - - - - --' L------ I ^� B YAKIMA AVE SE 24 +71 3 44 LEDI 1 - - - --I `- - - -- I I. - - - - - J L_ - _ - - - _ -__J L-- 14 116.1 In A YAKIMA AVE NE + _ - - -_ -J 4 E 14 116.1 --- _-- Z - w 71 +68.37 (1561H AVE. SE. - - -------- _ -r T ___ ________ __ _` _. - _.__ _ _ _ - "- -- -. - '=- -1 'Tr 1 -- + 1 �'N 'n^ =10 +00.00 (NE 1ST ST -- - -- ---- -' -' --- _ 1 1 I - -- - - - - 1 -- --- - - --- - - - -- - EXISTING 250 WATT _ _ LUMINAIRE ON ALUMINIM POLE TO REMAIN 1 -- .,. _ � I r \ - ---- - - - - -- -i r---- - - - --I :: I I I I � 2 4930°w 150.08' 1 I I I I `• I (] 9 I I I I N 150 WATT J 1 I I I 11 I rLl^l 61 LAORAIRE ON WOOD POLE I Iv, VED BY OTHERS 12 I I 13 V) 1 TRACT ,A,, i i i 14 STORM DRAINAGE I I I I ' Q LOT I I Q \ / o - __- I I n -__ -_J L ______ \ -'-- / z - - -3 L----- - - I _ - - --I L - - - -- \ ` - - - - - - - i - _ _ J L - - - - - - - - - - L - - 7w as - - - -' Q - - - - -- � o . ew 4sz.0 N874950 "W 150.06' °n TW 493.7 N 0. I OW 490.9 N87.4950 ' W 440:78' -- I I - f � I LUMINAIRE SCHEDULE LUM. NO. POLE ID. NO. CIRCUIT NO. LOCATION OFFSET (FEET) LED LAMP WATTAGE MAST ARM (FEET) MOUNTING HGT. (FT.) STANDARD PLAN # 1 40 2-#6, 1-#6 A 156TH AVE SE 70 +91 20.5' RT 44 4 14 40 117.2 2 3 A 156TH AVE SE 72 +17 20.5' RT 100/44 4 - #6, . 1 -#6 GREEN 35'/14' 117.1 3 PVC (SCHEDULE B NE 1ST ST 10 +68 16.5 RT 44 LED .6'/4' NA 14 11 .1 40) PSE POWER A NE 1ST ST 11 +18 16.5 LT 44 L DI NA 14 116.1 B NE 1ST ST 1 778-- 16.5 RT 44 LED NA 14 116.1 A NE 1ST ST 12 +23 79. 5 LT 44 LED NA 14 11.6.1 B NE 1ST ST 12 +96 16.5 RT 44 LED NA 14 116.1 8 A NE 1ST ST 13 +48 16.5 LT 44 LED NA 14 116.1 B NE 1ST ST + 16.5 RT L 116.1 NE 1ST ST + 16.5. LT 116.1 NE 1ST ST 15+01 16.5 RTI 414 L 116.1 A NE 1ST ST. 15 +38 .16.5 LT 1 44 LEDI NA 14 116.1 B NE 1ST ST + 16.5 RT 44 LED 14 116.1 B YAKIMA AVE SE 24 +71 19.5 LT 44 LEDI NA 14 116.1 In A YAKIMA AVE NE + 19.5 LT 4 E 14 116.1 CONSTRUCTION NOTES OINSTALL NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE FIXTURE AND POLE PER STANDARD PLAN 126,1, CONCRETE FOUNDATION, AND ASSOCIATED JUNCTION BOX PER DETAILS ON SHEET 2 AND 3, AND LUMINAIRE POLE SCHEDULE, 2O INSTALL ARTERIAL STREET DECORATIVE PEDESTRIAN LUMINAIRE FIXTURE AND POLE PER STANDARD PLAN 117,2, CONCRETE FOUNDATION, AND ASSOCIATED JUNCTION BOX PER DETAILS ON SHEET 2 AND 3, AND LUMINAIRE POLE SCHEDULE, O3 INSTALL ARTERIAL STREET DECORATIVE ROADWAY. LUMINAIRE FIXTURES AND POLE PER STANDARD PLAN 117.1, CONCRETE FOUNDATION, AND ASSOCIATED JUNCTION BOX PER DETAILS ON SHEET 2 AND 3, AND LUMINAIRE POLE SCHEDULE, O4 INSTALL ELECTRICAL SERVICE CABINET # XXX PER DETAILS ON SHEET 3, LOCATED ON 156TH AVE SE AT APPROXIMATE STATION 72 +87, 20.5' RT, COORDINATE WITH PSE FOR SERVICE CONNECTION. O INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD, LEGEND WIRING SCHEDULE CONDUIT RUN CONDUIT. SIZE. APPROXIMATE AND MAY NOT CONDUCTORS NOTES . 1 2.0" PVC SCHEDULE 40 2-#6, 1-#6 GREEN AND FIELD VERIFY. 2 2.0 PVC SCHEDULE 40 4 7#6, 1 -#6 GREEN 3 2.0 PVC k5GHFULILL 80 4 - #6, . 1 -#6 GREEN 4 2.0" PVC (SCHEDULE 40) 4-#6, 1-#6 GREEN 3-#14 PHOTOCELL 5 2.0" PVC (SCHEDULE 40) PSE POWER 30 0 30 60 scale feet LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND MAY NOT BE ACCURATE OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO POTHOLE AS REQUIRED AND FIELD VERIFY. LOCATION OF UTILITIES UNDERGROUND UTILITY NOTE :, YOU MUST CALL 1-800-424-5555 NOT LESS THAN 72 HOURS BEFORE BEGINNING EXCAVA71ON WHERE ANY UNDERGROUND UTILITIES MAY BE LOCATED. FAILURE TO DO SO COULD MEAN BEARING SUBSTAN77AL REPAIR COS7S. (UP TO 7HREE TIMES THE COST OF REPAIRS TO THE SERVCE). 14EWV LED PEDESTRIAN LUMINAIRE RECOMMENDED AND .DECORATIVE POLE FOR APPROVAL 3/1749 LED ROADWAY LUMINAIRE i AND DECORATIVE POLE B BY - - - - -- PVC CONDUIT (SEE WIRING SCHEDULE) CHECKED FOR COMPLIANCE TO CITY STANDARDS ® TYPE 1 JUNCTION BOX WITH DATE CONCRETE PAD DATE BE SERVICE CABINET DATE Q WIRE NOTE O CONSTRUCTION NOTE T=36650 C -(I - 36G5o1 NORTHIANE�T Ti4.4 FF /C EXPE�4TS IF 11410 NE 124th St., #590, Kirkland, WA 98034 Phone: 425.522.4118 Fax: 425.522.4311 11-spa