HomeMy WebLinkAboutS-361608TFWz
U
w
0
a
F
EZ
Z
0
U)
Z
W
X
I.I.I
cr
I.I.I
I.L.I
I-
U_
F-
_)
0
J
O
O
U
W
d
CIO
U)
LEGEND
a O
0
SANITARY SEWER CLEANOUT
EXISTING
PROPOSED
ROADWAY
S
r,►
ROADWAY CENTERLINE
n✓
-- -�.
PROPERTY / LOT LINE
Tb
A
RIGHT -0F -WAY
4
- _- _ - -___-
BOUNDARY LINE
- --
M
EASEMENT LINE
- - - - - -
- - - - - -
BUILDING SETBACK UNE
- ....-- _- -------- - - - - --
_-___-_._.__._. -
ROLLED CURB AND GUTTER
A
- - - -- -
VERTICAL CURB AND GUTTER
T
t
CONTOUR (MINOR)
------- ��? - - - --
-- e1z --
CONTOUR (MAJOR)
db
--
FOOTING DRAIN FLOWPATH
`f`
m
SPOT ELEVATION
LI
T
TOP/TOE OF SLOPE
-- �__.- ---�— ____�_
-�___- 1----__A
CONCRETE SIDEWALK
f e9
0
CONCRETE BLOCK WALL
-
Ix
ROCKERY
c -�.o
0000000L- l
BARRICADE
0i
SIGNAL JUNCTION BOX
BOLLARDS
a a
SANITARY SEWER STUB MARKER POST
MAILBOX
TRAFFIC PEDESTRIAN POLE
o
DOWNSPOUTS
O
0
STORM DRAINAGE
DOT
. -,
CATCH BASIN TYPE 1 W /GRATE
it
TRAFFIC SIGNAL POLE W /LIGHT
CATCH BASIN TYPE 1 W /SOLID LID
LN
DRAIN
CATCH BASIN TYPE 2 W /GRATE
CIS'
E
CATCH BASIN TYPE 2 W /SOLID LID
O
&
STORM DRAIN MANHOLE
G OO
m
BEEHIVE MANHOLE
a
FIBER OPTIC STUB MARKER POST
YARD DRAIN (ROUND LID)
O
CATCH BASIN
YARD DRAIN
sa
FINISH GRADE
STORM DRAIN CLEAN -OUT
Oco
rC)
STORM DRAIN PIPE
- o
C`
ROOF DRAIN
--------- ... _.-
TELEPHONE JUNCTION BOX (UG)
SO SERVICE 6" CPEP WITH
Ij,
SATELLITE DISH
INVERT ® END OF PIPE
...._.. _._._- __._... _.0
GALV
SANITARY SEWER MANHOLE
a O
0
SANITARY SEWER CLEANOUT
0 SOS
O
SANITARY SEWER GRAVITY
S
r,►
SANITARY SEWER FORCE MAIN
n✓
-- -�.
TRAFFIC
STRAIGHT /RIGHT TURN ARROW
Tb
A
STRAIGHT /RIGHT TURN ARROW
4
4
LEFT /RIGHT TURN ARROW
v
M
STRAIGHT /LEFT /RIGHT TURN ARROW
41
BLOCK
LEFT TURN ARROW
S
1%
RIGHT TURN ARROW
A
A
STRAIGHT ARROW
T
t
HANDICAP PARKING
c4•-
&
BIKE LANE
db
cO6
TRAFFIC SIGN
`f`
m
INFORMATION SIGN
LI
T
STREET LIGHT
m-
SOIL LOG
CONSTRUCTION SEQUENCE:
1, THE CONTRACTOR SHALL COMPLETE THE INSTALLATION OF THE
SANITARY SEWER LINES WITHIN ONLY ONE ROADWAY BLOCK AT A
TIME AND SHALL COMPLETE THE TEMPORARY HOT —MIX ASPHALT
RESTORATION OF EACH ROADWAY BLOCK BEFORE BEGINNING
WORK IN ANOTHER BLOCK.
2. TEMPORARY RESTORATION OF TRENCHES FOR OVERNIGHT USE
SHALL BE ACCOMPLISHED BY USING HOT —MIX ASPHALT (HMA).
STEEL PLATES MAY BE USED OVERNIGHT TO COVER THE LAST
SECTION OF TRENCH. STEEL PLATES MUST BE PINNED DOWN
AND ASPHALT RAMPS /WEDGES MUST BE PLACED AROUND THE
PLATES. STEEL PLATES SHALL NOT BE USED ON STEEP GRADES
OR WHERE STEEL PLATES PRESENT A ROADWAY HAZARD.
EXISTING FEATURES
WETLAND WITH BUFFER
� v i
0
WETLAND FLAG
— CLEARING LIMITS
POWER POLE W /DROP LINE & LIGHT
FILTER FABRIC FENCE
Ili[
BIKE RACK
-.7`-
POWER POLE W /DROP LINE, LIGHT & TRANSFORMER
INTERCEPTOR DITCH
�J
DEBRIS PILE
-<$
POWER POLE W /DROP LINE & TRANSFORMER
®
fir
FIRE PIT
c
POWER POLE W /LIGHT
GRAVEL CONE
BUILDING
RIP RAP PAD
BLOCK
BO
BLOW OFF
BOW /BW
BOLLARD
1'
POWER POLE W /LIGHT & TRANSFORMER
BW
u
HORSE SHOE PIT
-0_
POWER POLE
CATCH BASIN
R
MAILBOX
-V_
POWER POLE W /TRANSFORMER
CLR
m
MILE POST MARKER
LI
PAD MOUNTED TRANSFORMER
CLEANOUT
-G
SOIL LOG
[Pi
POWER VAULT /MANHOLE
CONN
-u-
SIGN
Ix
SIGNAL CONTROL BOX
CONTINUED
�` -
SEPTIC DISTRIBUTION BOX
0i
SIGNAL JUNCTION BOX
CF
CUBIC FEET
SANITARY SEWER STUB MARKER POST
J },
TRAFFIC PEDESTRIAN POLE
DEGREE OF CURVATURE
Svv
SEPTIC VENT
G-: --
TRAFFIC SIGNAL POLE
DOT
. -,
STORM PIPE INLET /OUTLET
G: --
TRAFFIC SIGNAL POLE W /LIGHT
DRAWINGS
D
DRAIN
EDP
EDGE OF PAVEMENT
E
Co
STORM DRAIN STUB MARKER POST
&
FIBER OPTIC MANHOLE
ELEVATION
m
ROOF DRAIN
a
FIBER OPTIC STUB MARKER POST
EXIST
It
CATCH BASIN
r < --
TELEPHONE GUY ANCHOR
FINISH GRADE
FIG
CABLE TV MARKER POST
rC)
TELEPHONE ANCHOR POLE
FL/FL
C`
CABLE TV RISER
L <�
TELEPHONE JUNCTION BOX (UG)
FEET
Ij,
SATELLITE DISH
Cr)
TELEPHONE MANHOLE
GALV
^;-
LUMINAIRE W /ARM
Y
TELEPHONE STUB MARKER POST
GATE VALVE
rt
LUMINAIRE
-G
TELEPHONE POLE
LANDSCAPE LIGHT
D
TELEPHONE RISER
>:
;..�
YARD LIGHT (UNDER 10' TALL)
'0'
FIRE DEPT CONNECTION
VI
GAS STUB MARKER POST
HOSE BIB
iD
GAS VALVE
LR1
IRRIGATION CONTROL VALVE
oc0
OIL FILLER CAP
G
WATER MANHOLE
P&
GUY ANCHOR
WATER STUB MARKER POST
P -G?
GUY POLE
mv"g
MONITORING WELL
<1
POWER GRATE
O
POST INDICATOR VALVE
ELECTRICAL JUNCTION PULL /BOX
,.
SPRINKLER HEAD
3
ELECTRICAL STUB MARKER POST
(55:1
WATER VAULT
A
ELECTRICAL METER
WATER WELL
-- c
- -__
GAS
- -T1- - - lj - - --
GUARD RAIL
Oil
OIL
------ C;- - - ----
FENCE, BOARD
I,
POWER (BURIED)
—: < --
FENCE, BARB -WIRE
P
-
POWER (AERIAL)
---- --4- - - - - --
FENCE, CHAIN -LINK
PO
FIBER OPTICS
FENCE, ELECTRIC
i
T
TELEPHONE (BURIED)
�- -�<°j� -
FENCE HOG WIRE
- T
- -
TELEPHONE (AERIAL)
- --_-
FENCE, SPLIT RAIL
- c
TV CABLE (BURIED)
-- - --
FENCE, WIRE
- -- c
-- -
TV CABLE (AERIAL)
- - ---- -0 --
FENCE WROUGHT IRON
-
CREEK OR STREAM CENTERLINE
-I I-
RAILROAD TRACKS
WETLAND WITH BUFFER
� v i
CONSTRUCTION ENTRANCE
WARNING:
THE UTILITY LOCATIONS SHOWN
ARE APPROXIMATE ONLY. DEPTH
UNKNOWN. CALL 1- 800 - 424 -5555.
T.F-S.C.P.
— —
— CLEARING LIMITS
0
FILTER FABRIC FENCE
xx—
2
CUTOFF SWALE
AMERICAN NATIONAL STANDARDS INSTITUTE
INTERCEPTOR DITCH
ANGLE POINT
-- O - - -O-- N.G.P.E. FENCE
®
ROCK CHECK DAM
®
SEDIMENT FILTER
®
STRAW BALE
BLIND FLANGE
GRAVEL CONE
BUILDING
RIP RAP PAD
CONSTRUCTION ENTRANCE
WARNING:
THE UTILITY LOCATIONS SHOWN
ARE APPROXIMATE ONLY. DEPTH
UNKNOWN. CALL 1- 800 - 424 -5555.
CONSULTING ENGINEERS
LLC
�`ylP ' %I
STE K
, �
L
0
® 18t5�' "s"� 1® 1101w1
Bb8 O, 9Wt• 210
FW0OaI WW, WASSOW
www•esmciviLCOm
CM, Ec9lneen ^9 1 v kl+euw'v°i"a"y°en.ea 1 axawnl"a°cnneew,•
Public Warkn
1
2
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
ESM JOB #1655- 001 -011
ANGLE POINT
ASPH
i
STREAM WITH BUFFER
SURVEY
IS PROPOSED MONUMENT IN CASE
® FOUND MONUMENT IN CASE
DOOM PROPOSED MONUMENT (AS DEFINED)
OoM FOUND MONUMENT (AS DEFINED)
A DELTA
(R) RADIAL BEARING < >
(NR) NON- RADIAL BEARING
L ARC LENGTH
REVISION
ABBREVIATIONS
AVE
AVENUE
AC
ASBESTOS CEMENT PIPE
Al
ADJACENT
ALUM
ALUMINUM
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
AP
ANGLE POINT
ASPH
ASPHALT
ASTM
AMERICAN SOCIETY OF TESTING AND MATERIALS
ASSY
ASSEMBLY
BF
BLIND FLANGE
BLDG
BUILDING
BILK
BLOCK
BO
BLOW OFF
BOW /BW
BOTTOM OF WALL
BVC
BEGIN VERTICAL CURVE
BW
BACK OF WALK
CTR
CENTER
CB
CATCH BASIN
CI
CAST IRON
cl
CENTERLINE
CLR
CLEAR
CMP
CORRUGATED METAL PIPE
CO
CLEANOUT
CONC
CONCRETE
C
CONDUIT
CONN
CONNECTION
CONTR
CONTRACTOR
CONT
CONTINUED
CY
CUBIC YARDS
CL
CLASS
CF
CUBIC FEET
CFS
CUBIC FEET PER SECOND
DC
DEGREE OF CURVATURE
DI
DUCTILE IRON
DIA /0
DIAMETER
DOT
DEPARTMENT OF TRANSPORTATION
DIM
DIMENSION
DWGS
DRAWINGS
D
DRAIN
EDP
EDGE OF PAVEMENT
E
EAST
ELEV
ELEVATION
EL
ELEVATION
ELEC
ELECTRICAL
EVC
END VERTICAL CURVE
EXIST
EXISTING
FDC
FIRE DEPARTMENT CONNECTION
FG
FINISH GRADE
FIG
FIGURE
FIN
FINISHED
FL/FL
FLOWLINE
FL
FLANGE
FT
FEET
FM
FORCE MAIN !.
GA
GAUGE
GALV
GALVANIZED !.
GI
GALVANIZED IRON '..
GV
GATE VALVE
wRnw: Nnw lee¢
•RL HORIZOMN: !4D 198J/1991
of "�E�wl DATUM
AT FULL SCI1E
IF NOT
ID
INSIDE DIAMETER
IE
INVERT ELEVATION
IN
INCHES
L
LENGTH
ONE INCH
POUNDS
SCNE FCLOR9INGLY,.
LINEAL FEET
ID
INSIDE DIAMETER
IE
INVERT ELEVATION
IN
INCHES
L
LENGTH
LB
POUNDS
LF
LINEAL FEET
MAX
MAXIMUM
MFR
MANUFACTURER
MH
MANHOLE
MIN
MINIMUM
MJ
MECHANICAL JOINT
MISC
MISCELLANEOUS
N
NORTH
NO
NUMBER
NIS
NOT TO SCALE
OC
ON CENTER
OD
OUTSIDE DIAMETER
OHW
ORDINARY HIGH WATER
PI
POINT OF INTERSECTION
PP
POWER POLE
PVI
POINT OF VERTICAL INTERSECTION
PE
POLYETHYLENE
PERF
PERFORATED
PVC
POLYVINYL CHLORIDE
PVMT
PAVEMENT
PVT
POINT OF VERTICAL TANGENCY
PC
POINT OF CURVATURE
PT
POINT OF TANGENCY
QTY
QUANTITY
RET
RETAINING
RR
RAILROAD
R
RADIUS
RED
REDUCER
REINF
REINFORCED
RED
REQUIRED
R/W
RIGHT OF WAY
S
SOUTH
SCH
SCHEDULE
SO
STORM DRAIN
SF
SQUARE FEET
SHT
SHEET
SPECS
SPECIFICATIONS
SO
SQUARE
SS
SANITARY SEWER
STA
STATION
STD
STANDARD
TC
TOP OF CURB
TEL
TELEPHONE
THRD
THREADED
THRU
THROUGH
TOW /TW
TOP OF WALL
TYR
TYPICAL
VERT
VERTICAL
W
WEST
W/
WITH
W/0
WITHOUT
WSS
WATER SAMPLING STATION
GENERAL NOTES:
1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE
LATEST STANDARDS AND SPECIFICATIONS OF THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT AND THE 2008 EDITION OF
THE WSDOT /APWA STANDARDS AND SPECIFICATIONS, AS
APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE
RENTON STANDARD PLANS & SPECIFICATIONS. SOME STANDARD
DETAIL DRAWINGS MAY HAVE BEEN MODIFIED FOR THE CONTRACT.
THE CONTRACTOR SHALL REFER TO DETAIL DRAWINGS INCLUDED
IN THE CONTRACT DOCUMENTS. A SET OF APPROVED PLANS
SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
2. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE
AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY
THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
DISTURBANCE. FOR UTILITY LOCATES CALL 800 - 424 -5555 (OR
811) A MINIMUM OF 72 HOURS PRIOR TO EXCAVATION.
3. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE
SUBMITTED AT THE PRE — CONSTRUCTION MEETING. ANY
MODIFICATIONS TO THE APPROVED TRAFFIC CONTROL PLAN SHALL
BE RESUBMITTED AND APPROVED PRIOR TO IMPLEMENTATION.
4. ALL FITTINGS SHALL BE BLOCKED PER CITY OF RENTON
STANDARD DETAILS UNLESS OTHERWISE NOTED.
5. THE CONTRACTOR SHALL USE A VACUUM STREET SWEEPER TO
REMOVE DUST AND DEBRIS FROM PAVEMENT AREA AS DIRECTED
BY THE ENGINEER. FLUSHING OF STREETS SHALL NOT BE
PERMITTED.
6. BEFORE COMMENCEMENT OF TRENCHING, THE CONTRACTOR
SHALL PROVIDE A CATCH BASIN FILTER FOR ALL DOWNHILL
STORM DRAIN INLETS AND CATCH BASINS. THE CONTRACTOR
SHALL PERIODICALLY INSPECT THE CONDITION OF ALL FILTERS
AND REPLACE AS NECESSARY.
7. PAVEMENT MARKINGS (E.G. LANE LINE BUTTONS OR PAINT, STOP
BARS, CROSSWALKS, ETC.) DAMAGED OR REMOVED DURING
CONSTRUCTION SHALL BE REPLACED IN KIND.
NOTE:
1. LOT LINES ARE BASED ON GIS INFORMATION AND ARE FOR
GENERAL INFORMATION ONLY.
2. 3" SEWER FORCE MAIN SHALL BE HOPE SDR 11 PIPE MATERIAL.
3. GRAVITY SANITARY SEWER PIPE MATERIAL:
• PVC SDR35 - 4' TO 15' OF COVER
• PVC C900 - LESS THAN 4' OF COVER
• PVC C900 - OVER 15' OF COVER '..
SURVEY DATUM:
HORIZONTAL DATUM:
NAD83(91) WASHINGTON STAE PLANE COORDINATE SYSTEM NORTH
ZONE
VERTICAL DATUM:
NAVD 1988 CITY OF RENTON PUBLISHED BENCH MARKS
#1909 CASED MONUMENT WITH LEAD AND TACK AT THE INTERSECTION
OF SE 139th PLACE AND 156TH AVENUE SE.
ELEVATION = 408.64
#2088 CASE MONUMENT WITH %" BRASS DISC AT THE INTERSECTION
SE 142ND PLACE AND 156TH AVENUE SE.''..
ELEVATION = 372.34 !.
CITY OF RENTON PUBLISHED BENCH DESCRIPTIONS ARE REVERSED
FOR
BENCHMARKS #2088 AND #1909 '..
SITE CONTROL:
ESM CONTROL POINT LOCATED 27' NW OF THE INTERSECTION OF SE
136TH ST AND 168TH AVENUE SE.
N 178033.9669, E 1323118.6406, ELEVATION = 466.25
ESM CONTROL POINT LOCATED 511' WEST OF THE INTERSECTION OF
SE 136TH ST AND 168TH AVENUE SE ON THE SOUTHERLY EDGE OF
ASPHALT.
N 178031.6592, E 1322625.8698, ELEVATION = 454.97
5- 361602
s• CITY OF
RENTON
Planning /Building /Public Works Dept.
CHECKED FOR COMPLIANCE TO CITY STANDARDS
ISSAQUAH SCHOOL DISTRICT
SANITARY SEWER EXTENSION
LEGEND AND GENERAL NOTES
E:
DRAWING N0:
LG -01