HomeMy WebLinkAboutzT-1630SetCONSTRUCTION NOTES S.W! 7th STREET _ _ +00 - _5 4*22 - - R /W-*"4 - -- - - INSTALL GALV. STEEL SIGNAL POLE TYPE B -I WITH 30' MAST ARM, TWO VEHICLE SIGNAL LEADS, TWO PEDESTRIAN SIGNAL HEADS, AND TWO PEDESTRIAN PUSH - 1 I /2" �-,f' BUTTONS. INSTALL 250 WATT SODIUM VAPOR LUMINARE WITH PHOTO -CELL. INSTALL SIGNAL POLE FOLI- NDATION. `MIRING D INSTALL GALV. STEEL SIGNAL POLE TYPE D-I W/ 35- MASTARM, 3 VEH. SIGNAL HDS,2 PED SIGNAL HDS, ,B 2 PED PUSHBUTTONS. INSTALL 250 W S LUMINARE RUN NO `-✓ W/ PHOTO -CELL, INSTALL SIGNAL POLE FOUNDATION, (4 -5 /C, 1-3/C,2-2/C),(2#8) 3 INS T ALL GALV. STEEL SIGNAL POLE TYPE C -1 W130' MAST ARM, 2 VEH, SIGNAL HDS, 2 PED, SIGNAL HDS, a 2 PED PUSHBUTTONS. INSTALL 250 W S V, LUMINARE 3",2 ", 11/2" (7- 5/C,1- 3/C),(5 - 2/C),(4 #8) W/ PHOTO -CELL, INSTALL SIGNAL POLE FOUNDATION, (7 -5 /C, 1 -3 /C, 5 - 2/C),(7- 5/C,2- 3/C,3- 2/C),(6 -PAIR) 4 INSTALL GALV, STEEL SIGNAL POLE TYPE E -I W/ 40' MAST ARM, 3 VEH, SIGNAL HDS, 2 PED. SIGNAL. 'LIDS, ?a 2 PED. PUSHBUTTONS. INSTALL 250W Sy LUMINARE q BREAKER W/ PHOTO -CELL, INSTALL SIGNAL POLE FOUNDATION. SAWCUT 2 # 12 INSTALL CONTROLLER AND CONTROLLER CABINET TYPE P-1 ON RAISED CONCRETE FOUNDATION. R R INSTALL TYPE "B" CONCRETE JUNCTION BOX. wl 7 INSTALL TYPE "C" CONCRETE JUNCTION BOX. Q Y INSTALL 6'x6' INDUCTION LOOP DETECTOR WITH THREE TURNS OF WIRE. i W 3 INSTALL FIRE PRE - EMPTION DETECTOR. f 6#12 ICJ INSTALL CONDUIT INTO EXISTING UNDERGROUND VAULT, SEAL WITH GROUT. COIL SUFFICIENT AMOUNT OF WIRE FOR CONNECTION BY POWER PERSONNEL - Q 8# 12 "LEFT 5 11 INSTALL 24" x 30" SIGN R 10-10 TURN SIGNAL" ON MASTARM ADJACENT TO LEFT TURN SIGNAL HEAD. 6 12 INSTALL 6 -PAIR INTERCONNECT CABLE INTO EXISTING CONTROLLER CABINET AT 7th ST 81 RAINIER AVE. CONNECT WIRING AS DIRECTED BY ENGINEER. 1 l INSTALL STREET LIGHT WIRE INTO EXISTING CONTACTOR CABINET AT 7TH ST 8 RAINIER AVE. CONNECT WIRING AS DIRECTED BY ENGINEER. t f 4 I4 INSTALL CONDUIT INTO EXISTING JUNCTION BOX. 7 7 11/2" 2#8 R GENERAL NOTES S 11/2", 11/2" (6- PAIR),(2 #8) B R R R TYPE A ELECTRICAL SERVICE 4 I. AS A PART OF THIS PLAN, REFERENCE SHALL BE MADE TO THE SPECIAL PROVISIONS, DETAILS, WASH. STATE D.O.T. STD. PLANS 81 SPECS., a NAT -L ELEC. CODE. /191 ! -- 2 2. ALL POLE LOCATIONS SUBJECT TO THE APPROVAL OF THE TRAFFIC ENGINEER. 5 d 4,5 R R 3, NO UNDERGROUND OR IN -LINE SPLICES SHALL BE PERMITTED UNLESS OTHERWISE NOTED. r R p 4 A SEPERATE GROUNDING SYSTEM SHALL BE PROVIDED CONSISTING OF A NO.8 AWG WIRE CONNECTING THE GROUND WIRETERMINALAT THE BASE OF 7 ^ EACH SIGNAL POLE TO THE NEUTRAL BAR IN THE CONTROLLER CABINET. APPROVED UNDERGROUND SPLICES IN THE GROUND CIRCUITARE PERMITTED. { 77 t R R R R R R R R R _ - -- _ 13 R I - S.W! 7th STREET _ _ +00 - _5 4*22 - - R /W-*"4 - -- - - 11/2", 1 1/2" (1 -2 /C, 6- PAIR),(2#f8) 1 I /2" 1201 V AC 2 ", I 112' `MIRING SCHEDULE (3 -5 /C, I- 3/C),(3- 2/C,6-PAIR),(2 #8) RUN NO CONDUIT SIZE WIRE SIZE (4 -5 /C, 1-3/C,2-2/C),(2#8) 2 ", 1 1/2" SINGLE 35 A 3",2 ", 11/2" (7- 5/C,1- 3/C),(5 - 2/C),(4 #8) 31/2 ",3 ", 11/2" (7 -5 /C, 1 -3 /C, 5 - 2/C),(7- 5/C,2- 3/C,3- 2/C),(6 -PAIR) 31/2",3",11/2",2" (7-5/C, 1-3/C, 5- 2/C),(7- 5 /C,2 -3 /C, 4- 2 /C),(6- PAIR),(EMPTY) 11/2" BREAKER I SAWCUT 2 # 12 Y R R R R 2 SAWCUT 4# 12 Y G TO CONTROL 3 SAWCUT 6#12 EQUIPMENT 4 SAWCUT -- 8# 12 R 5 1° 4#12 NOTE: BREAKER TO BE LOCATED WITHIN Y Y CONTROLLER CABINET. 6 1" 8#12 Y 7 11/2" 2#8 R 8 11/2", 11/2" (6- PAIR),(2 #8) R R R R TYPE A ELECTRICAL SERVICE 4 1 1/2" 1- 2/C -- 11/2", 1 1/2" (1 -2 /C, 6- PAIR),(2#f8) 1 I /2" 2 -2 /C 2 ", I 112' (3 -5/C, 1- 3/C),(2 #8) ' 2 ,2'' ,11/2' ' (3 -5 /C, I- 3/C),(3- 2/C,6-PAIR),(2 #8) 2 ", 11/2" (4 -5 /C, 1- 3/1),(2 #8) 3 ", 1 1/2" (4 -5 /C, 1-3/C,2-2/C),(2#8) 2 ", 1 1/2" (3- 5/C),(2 #8) 3",2 ", 11/2" (7- 5/C,1- 3/C),(5 - 2/C),(4 #8) 31/2 ",3 ", 11/2" (7 -5 /C, 1 -3 /C, 5 - 2/C),(7- 5/C,2- 3/C,3- 2/C),(6 -PAIR) 31/2",3",11/2",2" (7-5/C, 1-3/C, 5- 2/C),(7- 5 /C,2 -3 /C, 4- 2 /C),(6- PAIR),(EMPTY) 11/2" 6 -PAIR 9 2 I 4 4 5 L�J1 IN ! I I " I it 4 n I 1 r. R 4'. i9 SIGNAL SEQUENCE CHART 1 _ 0 1 +5 CHANGE TO stn t+p aro - N N V to W51 Ws 0 I +6 CHANGE TO , h + tD m t N sV -T J I& Ws, M is rs 0 2 +5 CHANGE TO in cD l>, *o jj ' + N d Q t9 t9 to tL 3 02+6 4 +8 CHANGE TO � in Ra Ul cfl is Ws m is c=n J CHANGE TO t9 10 * in N >ea m _.i tL 1,2 R R R R R R G Y Y G R Y R R R R R R G Y G R R Y R R R R R R R 3 Y Y Y Y Y Y Y R R R R RJR R R R R R R R R R R R R R d 4,5 R R R R R R R R R R R R R R R R R R R R R R RJR G Y Y Y Y Y R 6,7 R R 'R R R 'R R R R RJR R G Y Y G Y Y G Y Y Y Y R R R R R R R 8 Y Y'Y Y R R R R I R R Y Y Y Y R R R R R R R R R R RJR R 9,10 R R R R' R R R R R R R R R R R R R R R R R R R R G Y 'Y Y Y Y R 11,12 D F F DWMpW WI F F )WDWDWDWDN)%D% DW DE 13,14 DW DW DW DW W DW D F D D DE 15,16 DW ' DW D MOW F DW DW F F D F DW D DW DE 17,18 DW I� D D DW DW D DW D DW OW DW E D DE SEMIENCE NOTES= I. EASTBOUND EMERGENCY PRE- EMPTION R= RED Imm SHALL SEQUENCE TO 02+ 5. 2 WESTBOUND EMERGENCY PRE-EMPTION SHALL SEQUENCE TO 01 + 6. 3. NORTH a SOUTH BOUND EMERGENCY PRE- EMPTION SHALL SEQUENCE TO 0 4 +8. A R/. - - SIGNAL HEADS Y = YELLOW G = GREEN F= WALK, FLASH DONT WALK DW =DONT WALK DE = DE- ENERGIZE 4{OG - - -9+52 _(i - - 01+6 �1 10 i 6 r 2 ! R 128 R 12„ i 4{ T 1 8 s I 12 7 �J 1;2 u I 12° G 12° I� I 3,8 1,2,4,5x6,7,9,10 _A I T • I � � 01+5 11,12.13.14,15,16,17,18 SIGNAL NOTES: 1- �s L ALL YEtI. HEADS SHALL HAVE TUNNEL VISORS - -I• AND SQUARE DOORS. 2-ALL VEH_ HEADS SHALL USE MOUNTING TYPE L. 3. ALL PED. HEADS SHALL BE NEON WITH EGG CRATE 2+5 VISORS- PED HEADS SHALL USE L O C H N E R' TYPE AMOUNTING. 0,� n H. W. LOCHNER, INC., 301-116th AVENUE. S.E..SUITE 390. BELLEVUE. wASr+iNG DON 98004 F(r AlAlK SCALE IN FEET2 20 10 0 20 40 60 80 NO. REVISION BY APPR. DATE lltl4 PHASING 2 +6 04 +8 CITY OF'RENTON DEPARTMENT OF PUBLIC WORKS SW 7th ST. & HARDIE AVE. SW SIGNALIZATION PLAN SIGNED CJS DXTE 12-14-81 PILE NO. AWN CJS I ECKED SCALE C-20 FIELD soon aA�� ?ROVED SHEET 2 OF_ 4 CHANNELIZATION NOTES 01 INSTALL THERMOPLASTIC ARROW. INSTALL THERMOPLASTIC CROSSWALK. PAINTED LINE BY OTHERS, 4 INSTALL REGULATORY SIGN R3-7 "RIGHT LANE MUST TURN RIGHT" WITH POST. INSTALL YELLOW IV' PLASTIC TRAFFIC BUTTONS 10' O.C. 06 INSTALL WHITE 10" PLASTIC TRAFFIC BUTTONS 20'O.C. INSTALL YELLOW 10" PLASTIC TRAFFIC BUTTONS 5'0,C. OINSTALL WHITE 10" PLASTIC TRAFFIC BUTTONS 10' C.C- SCALE IN FEET IN If 20 10 6 20 40 6O 80 7 SD so —Sr SL SG 5 w w 7 T T T T T FM S.W. 7th STREET T UTILITIES LEGEND W 0 G GAS P - POWER z w 3 Y T TELEPHONE > ss- SANITARY SEWER -SD STORM DRAIN W I T v W - WATER FH FIRE HYDRANT 0 WV WATER VALVE 5 OMH MAN HOLE NOTE: UTILITIES SHOWN ARE NOT GUARANTEED TO BE ACCURATE OR COMPLETE. G> THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL FACILITIES. 00ooeAo;o CITY OF RENTON L OCHNER DEPARTMENT OF PUBLIC WORKS SIN 7th ST & HARDIE AVE. SW H. W. LOCHNER, INC.. 301- 1161n AVENUE, S E. SUITE390. BELLEVUE, W.ASH1%-GToN 96C04 CHANNELIZATION a UTILITIES 4�– DESIGNED DATE 12-15-81 D FILE NO- DRAW cis I" - 20, REVISION BY APPR. DATE APPROVED SHEET