HomeMy WebLinkAboutzT-1834SetEXISTING POWER POLE. Q/ Qv 0) O= I I /a" PVC WITH (3) 02 CU USE /XLP f CONDUCTORS $ TANDARD #3660 F CENTER STANDARD BETWEEN DRIVEWAYS CONTACTOR PANEL I i i i i i, I L r JJ Z Q cr- PROVIDE SICK 80 PVC RISER 10 Ft ABOVE GRADE PANEL SCHEDULE / WITH 30 Ff CONDUCTOR ABOVE GRADE. NUMBER LOCATION LIGHTING CONTROL CABINET FURNISH ADDITIONAL 10 Ft LENGTH OF CONDUIT VOLTS 1 PHASE 3 WIRE p AND SUPPORTS FOR INSTALLATION BY PUGET POWER SERVING STREET LIGHT rEq6" PERSONNEL WHEN TERMINATIONS ARE MADE- CABINET DATE:12 CKT. LOAD DESCRIPTION KVA TRIP TRIP KVA -SITE PLAN CKT. NO. W E SCALE: 1" = 20' - O" I L r JJ Z Q cr- f// -12- YO NOTES: 1. COMPLY WITH CITY OF RENTON "GUIDELINES AND STANDARDS FOR STREET LIGHTING DESIGN OF RESIDENTIAL AND ARTERIAL STREETS ", HEREAFTER REFERRED TO AS "THE STANDARD ". 2. COMPLY WITH THE 1987 EDITION OF THE NATIONAL ELECTRICAL CODE, THE 1987 NATIONAL ELECTRICAL SAFETY CODE, AND CURRENT CODES AND ORDINANCES. 3. SCOPE OF WORK: PROVIDE ONE STREETLIGHT STANDARD EACH WITH A 250 WATT HIGH PRESSURE SODIUM COBRAHEAD FIXTURE ON A 30 FOOT ANCHOR BASE POLE; 100 AMP, 120/24OV., SERVICE CABINET WITH (1) 30A -4 POLE LIGHTING CONTACTOR, (1) FIXTURE MOUNTED PHOTO CELL, AND ALL WIRING. 4. BURY ALL CONDUIT A MINIMUM OF 24" BELOW GRADE. ALL DUCTS SHALL BE SCH.EDULE 40 PVC, MINIMUM SIZE I' INCH. ALL CONDUCTORS SHALL HAVE TYPE XLP INSULATION, LIGHTING BRANCH CIRCUIT SHALL CONSIST OF (2) #8 CU. 5. INSTALL GROUND RODS IN J -BOXES AND IN -LINE FUSES IN HANDHOLE AT POLE. 6. LUMINAIRE: GENERAL ELECTRIC # M- 25OA2'WITH IES TYPE'MC3 LIGHT DISTRIBUTION, FLAT GLASS LENS, 250 WATT LAMP, 240 VOLT MAGNETIC REGULATOR BALLAST, AND PHOTOELECTRICrCELL /RECEPTACLE. 7. COORDINATE WITH PSP &L RENTON (PHONE 255 -2464) CONCERNING SERVICE REQUIREMENTS. 8. COORDINATE INSTALLATION WITH EXISTING UNDERGROUND UTILITIES. OBTAIN ALL NECESSARY PERMITS FROM THE CITY OF RENTON. 9. CONSTRUCTION - NOTES: A. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. B. AS -BUILT DRAWINGS WILL BE REQUIRED ON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. C. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES REGARDING THEIR FACILITIES WHICH MIGHT BE DISTURBED AS A RESULT OF THIS PROJECT. D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AND THE CITY IMMEDIATELY UPON DAMAGE. 10. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON TRAFFIC ENGINEERING DIVISION(235 -2620) FOR INSPECTION PURPOSES 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED BY THE CITY'S INSPECTOR. JUNCTION BOX DESIGN "B" 5/16" GALV. STEEL COVER PLATE (DIAMOND PATTERN) I ` J - 06 GALV. WELDED WIRE LOOP PANEL SCHEDULE 0 100 A PANEL W/ BRANCH BREAKERS B REa D 0 2 ".ALE FEMALE BUSHINGS 0 PE CELL TERMINAL STRIP RACEWAY WITH REMOVABLE COVER TEST SWITCH © GF1. RECEPTACLE O LIGHTING CONTACTORS AS REO'D QSERVICE FEEDERS /20/88 4 4" B NUMBER LOCATION LIGHTING CONTROL CABINET 240/120 VOLTS 1 PHASE 3 WIRE p BELLEVUE, WASHINGTON 98004 SERVING STREET LIGHT rEq6" 100 AMP with MAIN BREAKER CABINET DATE:12 CKT. LOAD DESCRIPTION KVA TRIP TRIP KVA LOAD DESCRIPTION CKT. NO. AMPS AMPS 20 ^ scAI A'S SHOWN PIR10 bOOK_. -P"9_ NO. 1 NEW STREET LIGHT 0.2 SPACE 2 3 REVI810N BY APPR DATE SPACE 4 5 SPACE SPACE 6 7 SPACE SPACE 6 9 SPACE SPACE 10 11 SPACE SPACE 12 13 SPACE `1 . 20 0.2 RECEPTACLE 14 15 SPACE .. 20 0.1 LIGHTING CONTROL _ 16 REMARKS CONNECTED LOAD 0.5 KVA =2AMPS DEMAND LOAD 0.5 KVA f// -12- YO NOTES: 1. COMPLY WITH CITY OF RENTON "GUIDELINES AND STANDARDS FOR STREET LIGHTING DESIGN OF RESIDENTIAL AND ARTERIAL STREETS ", HEREAFTER REFERRED TO AS "THE STANDARD ". 2. COMPLY WITH THE 1987 EDITION OF THE NATIONAL ELECTRICAL CODE, THE 1987 NATIONAL ELECTRICAL SAFETY CODE, AND CURRENT CODES AND ORDINANCES. 3. SCOPE OF WORK: PROVIDE ONE STREETLIGHT STANDARD EACH WITH A 250 WATT HIGH PRESSURE SODIUM COBRAHEAD FIXTURE ON A 30 FOOT ANCHOR BASE POLE; 100 AMP, 120/24OV., SERVICE CABINET WITH (1) 30A -4 POLE LIGHTING CONTACTOR, (1) FIXTURE MOUNTED PHOTO CELL, AND ALL WIRING. 4. BURY ALL CONDUIT A MINIMUM OF 24" BELOW GRADE. ALL DUCTS SHALL BE SCH.EDULE 40 PVC, MINIMUM SIZE I' INCH. ALL CONDUCTORS SHALL HAVE TYPE XLP INSULATION, LIGHTING BRANCH CIRCUIT SHALL CONSIST OF (2) #8 CU. 5. INSTALL GROUND RODS IN J -BOXES AND IN -LINE FUSES IN HANDHOLE AT POLE. 6. LUMINAIRE: GENERAL ELECTRIC # M- 25OA2'WITH IES TYPE'MC3 LIGHT DISTRIBUTION, FLAT GLASS LENS, 250 WATT LAMP, 240 VOLT MAGNETIC REGULATOR BALLAST, AND PHOTOELECTRICrCELL /RECEPTACLE. 7. COORDINATE WITH PSP &L RENTON (PHONE 255 -2464) CONCERNING SERVICE REQUIREMENTS. 8. COORDINATE INSTALLATION WITH EXISTING UNDERGROUND UTILITIES. OBTAIN ALL NECESSARY PERMITS FROM THE CITY OF RENTON. 9. CONSTRUCTION - NOTES: A. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. B. AS -BUILT DRAWINGS WILL BE REQUIRED ON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. C. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES REGARDING THEIR FACILITIES WHICH MIGHT BE DISTURBED AS A RESULT OF THIS PROJECT. D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AND THE CITY IMMEDIATELY UPON DAMAGE. 10. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON TRAFFIC ENGINEERING DIVISION(235 -2620) FOR INSPECTION PURPOSES 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED BY THE CITY'S INSPECTOR. JUNCTION BOX DESIGN "B" 5/16" GALV. STEEL COVER PLATE (DIAMOND PATTERN) I ` J - 06 GALV. WELDED WIRE LOOP 100 AMP MINIMUM 0 100 A PANEL W/ BRANCH BREAKERS B REa D 0 2 ".ALE FEMALE BUSHINGS 0 PE CELL TERMINAL STRIP RACEWAY WITH REMOVABLE COVER TEST SWITCH © GF1. RECEPTACLE O LIGHTING CONTACTORS AS REO'D QSERVICE FEEDERS /20/88 4 4" B 144 i0 - 1 IOOA! L7 L -- SECTION A -A 3 LT � e 6 7 I6 "MIN. RENTON, WASHINGTON BELLEVUE, WASHINGTON 98004 MATH, EWSONES AUTO CENTER rEq6" TYPE III SERVICE CABINET DATE:12 4-111 f// -12- YO NOTES: 1. COMPLY WITH CITY OF RENTON "GUIDELINES AND STANDARDS FOR STREET LIGHTING DESIGN OF RESIDENTIAL AND ARTERIAL STREETS ", HEREAFTER REFERRED TO AS "THE STANDARD ". 2. COMPLY WITH THE 1987 EDITION OF THE NATIONAL ELECTRICAL CODE, THE 1987 NATIONAL ELECTRICAL SAFETY CODE, AND CURRENT CODES AND ORDINANCES. 3. SCOPE OF WORK: PROVIDE ONE STREETLIGHT STANDARD EACH WITH A 250 WATT HIGH PRESSURE SODIUM COBRAHEAD FIXTURE ON A 30 FOOT ANCHOR BASE POLE; 100 AMP, 120/24OV., SERVICE CABINET WITH (1) 30A -4 POLE LIGHTING CONTACTOR, (1) FIXTURE MOUNTED PHOTO CELL, AND ALL WIRING. 4. BURY ALL CONDUIT A MINIMUM OF 24" BELOW GRADE. ALL DUCTS SHALL BE SCH.EDULE 40 PVC, MINIMUM SIZE I' INCH. ALL CONDUCTORS SHALL HAVE TYPE XLP INSULATION, LIGHTING BRANCH CIRCUIT SHALL CONSIST OF (2) #8 CU. 5. INSTALL GROUND RODS IN J -BOXES AND IN -LINE FUSES IN HANDHOLE AT POLE. 6. LUMINAIRE: GENERAL ELECTRIC # M- 25OA2'WITH IES TYPE'MC3 LIGHT DISTRIBUTION, FLAT GLASS LENS, 250 WATT LAMP, 240 VOLT MAGNETIC REGULATOR BALLAST, AND PHOTOELECTRICrCELL /RECEPTACLE. 7. COORDINATE WITH PSP &L RENTON (PHONE 255 -2464) CONCERNING SERVICE REQUIREMENTS. 8. COORDINATE INSTALLATION WITH EXISTING UNDERGROUND UTILITIES. OBTAIN ALL NECESSARY PERMITS FROM THE CITY OF RENTON. 9. CONSTRUCTION - NOTES: A. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. B. AS -BUILT DRAWINGS WILL BE REQUIRED ON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT. C. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES REGARDING THEIR FACILITIES WHICH MIGHT BE DISTURBED AS A RESULT OF THIS PROJECT. D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AND THE CITY IMMEDIATELY UPON DAMAGE. 10. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON TRAFFIC ENGINEERING DIVISION(235 -2620) FOR INSPECTION PURPOSES 24 HOURS BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED BY THE CITY'S INSPECTOR. JUNCTION BOX DESIGN "B" 5/16" GALV. STEEL COVER PLATE (DIAMOND PATTERN) I ,BEY. lo-Z-67 DETAIL - -SHEET 4 -1 W. ZQ� p4 WASH /yC�C1 y GISTEQ`�r:•�4.�I p i 2nd P/. 'e OF A o j' a v � !� RE• .W. ?nd a80 VKWTY MAP ` J - 06 GALV. WELDED WIRE LOOP GALV. STEEL FRAME ANCHORED IN PLACE (DIAMOND PATTERN) 7 CITY OF 'RE,. TON DEPARTMENT OF PUBLIC WORKS :i.� SECTION A -A SECTION B -B ,BEY. lo-Z-67 DETAIL - -SHEET 4 -1 W. ZQ� p4 WASH /yC�C1 y GISTEQ`�r:•�4.�I p i 2nd P/. 'e OF A o j' a v � !� RE• .W. ?nd a80 VKWTY MAP I f ( I I E ) ) I I I A I A I CITY OF 'RE,. TON DEPARTMENT OF PUBLIC WORKS ENGINEERED ELECTRICAL SYSTEMS, INC. STREET LIGHTING PLAN FOR NELSON PLACE N.W. 612 BELLEVUE WAY N.E. SUITE 201 RENTON, WASHINGTON BELLEVUE, WASHINGTON 98004 MATH, EWSONES AUTO CENTER DESIGNED ME F. DATE, 11"9 -951 PILE NO DRAWK K. T scAI A'S SHOWN PIR10 bOOK_. -P"9_ CHECKED I APPROVED • !NE£TJ�1_OF2_ NO. REVI810N BY APPR DATE I f ( I I E ) ) I I I A I A TYIv/G -1L L/6t/TIN6 (i10a6koUO SYSTEM I _ .. - '8 BAFYE CO. �EfZ riAeE - 2 #l0 TNWiV -CC/ qll— IIII -��It -.r (I(1= 5i! s)� do POUNp 1 'I'll If To WM/(A/RE j I e (A. ZENGTf/ =Q= %8" 3 7"17- 7& /1/UMBEP /NG E.�MPL ES 2 POLE 240 VOLT PHm-ocE[.[c/ L 7--, " -1CAL 47--516W ;6" `fUMCT /ON 4TOX FUSE K /TS i PYG SST / QU /GK.cVSGGIVNECT !4?R/N1104.E PHOTOC E L L Va TERMIA 41- 6LO:.X. r-, X g • GOPPE�2- CLA,P7 /O AMA° rN LdVE FdsE Ai7S-S.E.a OffeOVAL 69OUNC .1?00 K/TS SF4R ' G TLWOFC6xe;MTE FOf/AGIAT /ON TO _Be LEVEL IY /TX E 0/- -1.4R EFbXY SK/LE Re vtU S THA?U li fIX/A/4 LG1S P.,�r te` ( 7ZW 7F51OE)VALK ae CURE _ .. - '8 BAFYE CO. �EfZ riAeE -. f 2 "To Zit " /AIAIV,GHT qll— IIII -��It -.r (I(1= 5i! s)� do POUNp 1 'I'll If I{ II e (A. ZENGTf/ =Q= %8" JQ 100 A. 'MAIN `BR�EAKE R (MIN.) /1/UMBEP /NG E.�MPL ES 2 POLE 240 VOLT i A © a 2 i 2 *aasB/XLP LICIRrIN ' SYSTEM wr eES ro CONTAG:ToR rp 3 TO PYG SST / II II II ll 3' 5A, 6W Z". I -� —�7 ,f.• PHOTOC E L L Va TERMIA 41- 6LO:.X. r-, X g • GOPPE�2- CLA,P7 CONCRETE FOir/NL7.4T /ON 69OUNC .1?00 TEST ' G IAG ll9 rPE ✓. /O -Z -87 ,C�'TA /L SNEET� CONCRETE PAD DETAIL LIGHTING STANDARD d JUNCTION BOX .vim 3?i��': �. � ::� -�. . •O: • P.' a STREET LIGHT POLE JUNCTION BOX PLAN VIEW �o•Ii �i 'e VV•• P. ' V. -1.�7`:, SIDE VIEW NOTE: CLASS '8' CONCRETE TO BE USE I" CONSTRUCTION OF .MD IYEICAL-PLAN VON ,e� ✓. /o - = -e� .OET.9 /G S//EET¢5 STREET LIGHTING CONTACTOR CABINET 2 "To Zit " /AIAIV,GHT WIRING SCHEMATIC TYPE M SERVICE 120/ 240 VOLT CUTT /rU� .ZINGS e (A. ZENGTf/ =Q= %8" JQ 100 A. 'MAIN `BR�EAKE R (MIN.) /1/UMBEP /NG E.�MPL ES 2 POLE 240 VOLT i A © a 2 i m BRANCH -1 a 3 BREAKERS. E A 120/240 VOLT z LETTER S&F/XED LETTEP PREF /XED 16 POLE TEST A SWITCH B B I A LI g a B C 11 TERMiNA B BLOCK UTILITY B B B PLUG A (G.F. I.) - — `STREET LIGHTING - CONTACTORS - 6073//C G^�.O 45 ae ovl = A A A _ (30 AMP) B B B B B D A CIRCUIT WIRES TO LIGHTING RUNS i°G9/V 1� /E1'Y WIRING COLOR CODE TOG�,OUND PHOTO -CELL ROD MOUNTED ON A. WHITE JACKET (NEUTRAL) NEAREST B. BLACK JACKET (LINE) LUMINAIRE C. GREEN JACKET (GROUND) D. RED JACKET (LOAD) E. GREEN OR BARE COPPER (GROUND) �w r_oz_aq DETAIL SHEET yL� 7'-O" SIDEWALK .y - 6" CURB CONCRETE "SRO'- 1DWaY� 4" THICK CONCRETE PAD FOR 1-ir,14T STANDARD - 4 juNCTION BOX , PHOTOCELL V CONCRETE BASE ` LUMINAIRE TAPERED ALUMINUM POLE TYPICAL LUMINAIRE =PLAN VIEW NOT TO SCALE A'!/rASeRS �.6E %USTXLL PS,-W /I/U1VASRS 2 "To Zit " /AIAIV,GHT 11"71C'XL L i /NSTAIC EA ONLY CUTT /rU� .ZINGS /N O.PY K/E.4Tllw ZENGTf/ =Q= %8" so• 09 ASOYE_ /1/UMBEP /NG E.�MPL ES i A Is0oxy 2 i 3 AuME svol -ls A SAL /CE LETTER S&F/XED LETTEP PREF /XED C/7'Y ax-mew P[/GET POWER rf'El� /o- z -87 osyaEo T �. 1 Vt / � � .PEfLECTQe/ZED 6073//C G^�.O 45 ae ovl = I� TPAFF /G LEGENO A5n/.l7 �• °vYO/V i°G9/V 1� /E1'Y ST,PEET L 16117 (STANDARD /s OECAL NU/yBE� /NCB SYSTEM L� /,/3 d HANDHOLE -- + So" PVG CONDUIT LTRENCId "TYPICAL LUMINAIRE -FRONT ELEVATION NOT TO SCAM -E //4 FUSE CUTT /rU� .ZINGS ZENGTf/ =Q= %8" � /AMETE,2= 7/8" FI�SE .e1T Is0oxy AuME svol -ls !Y)'E SPLICE SAL /CE KIT rf'El� /o- z -87 •UCIETA /G SHEET `/ � g 1., 2 SHAFT 1 2" W P S. /SL I PFIT TER 1 I f -- - — z O.D. .186 WALL BRACKET 5'9 ALUM. ALLOY 6063 -T6 1/2 13 LOCKBOLT GR, 18 8 S. S. \ \� FLUSH JOINT 0. TAPERED ALUM.POLE I 219 WALL ALLOY 6063 -T6 / SATIN GROUND FINISH 11" TO Q 1. BOLT CIRCLE / R 1/2" OF (4) 1 "BNC GALV. STL. ` BOLT ADOVE ANCHOR BOLTS WITH .1 FINISHED NUTS AND WASHERS GRADE' 4" CONCRETE ID± 151 HANOHOLE PAD 4". G"OPENING �W /COVER AND S SCREWS BAS6 E FLNGE LOY � �36-T6 A WITH AL _ DETAIL - COVERS B S.S. SCREW SHEET STANDARD 3d DAVIT POLE / -, STREET LIGHT CONTACTOR CABINET & CABINET FOUNDATION LOAD CENTER II � TEST SWITCH a 48" UTILITY PLUG STREET LIGHTING rent CONTACTORS �� MIN i`r MIN. FRONT VIEW PLAN VIEW SIDE. VIEW CABINET EOUIPMENT I. Pin tumbler -type stainless steel Best Care Lock (or equal) Keyed for CX - I wi In 2 Keys 2. 12 gauge (min.) galvanized sheet steel 3. Welded seam construction 4. Door with concealed hinges (left side) 5. Interior- white baked -on enamel 6. Exterior -gray- Etch galvanized surface- before painting. 7. Bottom open - 2"mounting flange (turned inward) on all sides 8.4- 3/8..x 16" anchor bolls w /rids and washers 9. 4- 1/4" triangular shaped corner lock -down plates CABINET FOUNDATION 4- I /2"x Ifi" ANCHOR BOLTS G.L. i� i� '� —G.L. CONDUIT ENTR. AREA r [ PLAN 227 VIEW �I —SIZE TO FIT CABINET ISIZE TO FIT CABINET —• ° ° �� ✓/d R7FRONT VIEW SIDE VIEW DETAIL SHEETS -// tY = m N c O ED 3 \' w Z z O U Z U Y U W W O Q. � d 03 Ir v � M S i# w ? LL Y is N x.ge it N a K F m W I STRAIN RELIEF DETAIL DESIGNED: K.G. DRAWN: J.L. DATE: 11-12 -zz DETAIL SHEET/. -:a r 1"4 /06 I a ! ! C E ! I A I I I A A I l I I! I l 1