Loading...
HomeMy WebLinkAboutzD-2070SetN184,200 4 \I 1 \ \ � 1 CB O Z Z m a REMOVE ALL PRODUCT, STEAM. p DRAIN, AND CONDENSATE LINES INSIDE DIKE CONTAINMENT WALLS, CAP LINES AT WALLS DR; WHERE NOT REMOVED OUTSIDE DEBEl TAC1K CONTAINMENT. 0 BLDG 4 -89 (STEAM PLANT) PRODUCT. STEAM, AND CONDENSATE LINES Z TO BE ABANDONED AND PLUGGED. O N184,10� \F " +� Imo + CLEAN AND REMOVE STEEL TANK 4(\ ARE -129 OCT Lzz o. SEE NOTE 7 Yl� N 186075.958 1 E 1660356 .71 718 \` � BM 54 tip m^�l Gft V ELEV =23 62 ry4 CB \ N \ TOP 2222 A P INV SW 20.82 CA REMOVE EXISTING y M° 50 \ 3 REMOVE 2-1/2"0 FIRE GAS SUMP AND VALVE � \2 D ASPHALT BOX LINE FROM THIS B S CB 2 11 6 SD POINT TO THE TANK TOP 2101 Ay INV W 2016 19.9 \ v> o INV 5 19 96 \ BLOW DOWN SUMP DIKE CONTAINMENT HOT CONDENSATE WATER v\, AREA WALLS NEW ASPHALT N FUEL TANKS PLAN - DEMOLITION ' RETE \ ro> REMOVED CONIC m \ ASPHALT Z 2' UTILIDOR r n * m HOSE PLATFORM y r 11 WJGR I f ` F m 1 CONCRETE 4Jy C04 PAD v. SLOG 4 -89 xp es pftPlN as > \.. p1E5EL TPNK o CO \ e \N 2.. WV. HW ry> NN I CATHODIC N 1843918.204 8 FUEL PORT N CABLE E 1650436.2f9 HATCH I BM 53 DIKE CONTAINMENT ELEV 2476 AREA WALLS CLEAN AND REMOVE STEEL TANK `\ TANK TOP El = EL= 526 NGP ARE -129 PIV N183.900 } _ M1> W / } >r sQ + WV / mNr 6 Hx� ro� GRAVEL QCs x a x' ' PI% xi ' CONCRETE A CONTAINMENT WALL �xi SECTION �x � NOT TO SCALE Ci Ci "994 '. CONCRETE GONEREO WPLKx i PLAN EXISTING CONDITIONS AS PpL J. UH w SYM REVISION BY PPRDVE DATE SYM REVISION BY PPRDVE DATE ACCEPTABILITY REVISIONS PER BOEING REVIEW COMMENTS OF ❑ AUBURN, WA 98002 E fI� THIS DESIGN AND /OR 01 JUN 9 A HA R WS R FINAL REVIEW JD /JH MJB 04 JUN ❑ EVERETT, WA. 98201 �(l i:,�, PEC IFICATION IS APPROVI o � ❑ KENT, WA. 98031 an° r��aUV� El PORTLAND, OR. 97226 �O .APPROVED BY IllT..jj DAT ■ RENTON, WA. 98055 2Z'1,NAL.ENo FACILITIES DEPARTMENT ',Y ❑ SEATTLE, WA. 98124 Etrwes a /I-- -� D A REMOVE AND SEGREGATE ALL OILED SAND (3 THICKNESS ANTICIPATED) OVER LINER /r REMOVE FILL ABOVE LINER / INSIDE DIKE CONTAINMENT NOTES 1. UNDERGROUND UTILITIES SHOWN HAVE BEEN PLOTTED FROM A COMBINATION OF FIELD - LOCATED SURFACE FEATURES AND RECORD DATA AS FOUND ON SCHEMATIC DRAWINGS. OTHER UTILITIES, NOT SHOWN, MAY ALSO BE PRESENT. CONTRACTOR SHALL VERIFY LOCATIONS BEFORE DIGGING, PROTECT EXISTING UTILITIES AND REPAIR ANY DAMAGES. 2, CUTS' DF CONTAINMENT WAIL, TRIPLE RINSE PRODUCT LINES, AND THEN REMOVE OR GROUT AND ABANDON IN PLACE. 3. DISPOSITION OF DEMOLITION MATERIALS AND NON- HAZARDOUS WASTE SHALL BE APPROVED BY THE OWNER. 4. A COPY OF THE PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. CONTRACTOR TO SAVE AND REINSTALL EXISTING SUCTION HEATER AND FOAM MAKER ON NEW TANK. _ 6. SOURCE OF BASE MAP IS FROM P SURVEY CONDUCTED BY PERMIT ENGINEERING, INC. UTILITY LOCATING WAS PERFORMED BY LOCATING INC. 7. CONTRACTOR MAY BREACH EXISTING CONTAINMENT. WALL TO PROVIDE CONSTRUCTION ACCESS FOR INSTALLATION OF UTILIDOR - ONLY. OTHER BREACHES IN CONCRETE CONTAINMENT DIKE SHALL BE MADE ONLY UPON WRITTEN APPROVAL OF OWNER'S REPRESENTATIVE. SAWCUT ENDS OF REMAINING WALLS TO PROVIDE SMOOTH VERTICAL SURFACES AND REMOVE ALL DEBRIS. CONTAINMENT WALL RESTORATION NOT REQUIRED. 8. SOURCE OF INFORMATION ON EXISTING DIKE CONTAINMENT WALLS AND TANK ARE TAKEN FROM EXISTING BOEING DRAWINGS. (250,000. GALLON FUEL OIL STORAGE FACILITY - RENTON, 1973) REMOVE LINER INSIDE w DIKE CONTAINMENT Hi�Quv �J.yq,�OG�P Ca�r> n,�.tPo. No D4070 N RECOMMENDED ` 4FAR OVA 0 20 40 BAfY SCALE. IN FEET RECOMMENDED s FOR APPROVAL Y BY �a VGr.Y HARKNOVISM ?44,V R&V /SW 10-23'92 AW DA TT E 93 SUBILE LRSi REVISION SYM DATE CJC EXISTING CONDITIONS AND DEMOLITION PLAN TITLE FUEL .STORAGE REPLACEMENT FOR ARE -129 RENTON FACILITY BLDG 4 -89 RENTON CyDF 6 J, C,NE. 305355 FU - ➢OMPWGk D. 304 - 089 -1002 NOTES: 1. PAVING DAMAGED DURING CONSTRUCTION SHALL BE REPLACED. RESTORE PAVING AND SUBGRADE TO ORIGINAL CONDITION. - 2. AFTER REMOVAL OF EXISTING LINER AND FILL, LEVEL SUBGRADE AND PROOF ROLL TO DENSE NON- YIELDING CONDITION PRIOR TO INSTALLING CRUSHED ROCK RINGWALL AND CRUSHED ROCK SURFACE COVER INSIDE DIKE CONTAINMENT WALLS. FINISHED GRADE: 24 FEET. 3. CONTRACTOR MUST PRESERVE ACCESS FOR OWNER'S USE OF DIESEL TANK AND CONCRETE FUEL CONTAINMENT AREAS AT ALL TIMES DURING CONSTRUCTION. CONTRACTOR TO COORDINATE INTERFERENCE AND POSSIBLE INTERRUPTIONS WITH OWNER'S REPRESENTATIVE. X 4. STAGING FOR TANK CONTRUCTION AND DEMOLITION MAY BE ALLOWED WEST OF DIKE CONTAINMENT AREA. EXACT AREA AND DURATION OF USE TO BE NEGOTIATED BY CONTRACTOR WITH OWNER'S REPRESENTATIVE. 5. PROVIDE ECOLOGY BLOCKS OR JERSEY BARRIERS (2 FOOT MAX. SPACING) TO PROTECT TEMPORARY PIPING FROM ` TRAFFIC ALONG ENTIRE LENGTH OF PIPING RUN, SUBMIT PLATE AND BLOCKING PLAN FOR VEHICLE CROSSING OVER TEMPORARY PIPING WHERE NEEOED. SANDBAGS PLACED TO _ ' HEIGHT OF THREE FEET ACROSS ENTIRE WIDTH 6. DRAINAGE WORK SHALL BE IN ACCORDANCE WITH THE WASHINGTON STATE D.O.T. /A.P.W.A. SPECIFICATIONS OF CONTAINMENT EXTERIOR CONTRACT LIMITS (1991 EDITION) AND THE STANDARD PLANS. SEE NOTE 7. (SEE SHEETS YDE110,YDE110R, AND IL60 FOR WORK INSIDE 7. CONTRACTOR TO PLACE TEMPORARY PS 300 SERVICE TANK INSIDE CONTAINMENT EITHER BY LIFTING IT IN WITH m 4 -89 BUILDING) .. APPROPRIATE CRANE OR CUTTING WALL ON WEST SIDE OF CONTAINMENT AND TRANSPORTING IT IN ON WHEELS. AFTER SPOTTING TANK, A MINIMUM CLEARANCE OF FIVE FEET SHALL BE PROVIDED ON ALL SIDES. CONTRACTOR SHALL CONSTRUCT A SECONDARY CONTAINMENT CELL, USING THE EXISTING WALLS AND SAND BAGS, OR OTHER 30 "0 NEW DOUBLE -WALL APPROVED DEVICES, AROUND THE TANK, PROVIDING A MINIMUM STORAGE VOLUME OF 26,250 GALLONS. - STEEL TANK TO BE ERECTED _ ON SAME CENTER POINT AS - REMOVED TANK SEE NOTE 8 i aN.m - - DIESEL TANK HOSE PLATFORM - - 'EXISTING 12" m STORM DRAIN PRIMARY TANK SHELL - �(I\ '0S o PRIMARY TANK BOTTOM VALVE BOX o CB 6 0 SHUT OFF VALVE n Y SECONDARY TANK SHELL OIL WATER SEPARATOR oOZ UTILITY VAULT 3030 -LA SECONDARY TANK BOTTOM, PROVIDE O - a OR EQUAL CORROSION PROTECTION PER API. A RECOMMENDED PRACTICE 651. 6'!;! GATE STORM LINE VALVE CB 8'm CAST IRONS Cg EoL. 24.0 CAP AND SEAL CO. —L / o ; Q 000ce pO� e ro oil a paa 5" O .71K O �'y O \IS CAST IRON B �S 0 STORM LINE .. / I O8O U° " 2 3/4" MINUS PER \ PLUG ANO 6 0 CAST IRON STORM LINE / -10o 1 SEAL / SPECIFICATION 8'0 CAST IRON STORM LINE �__._ CONCRETE FUEL 1 gyp° d CONTAINMENT AREA o 0 q DRAIN 0 6 O. CAST IRON STORM LINE (TO REMAIN) q'� O (D- CONCRETE CB I FOUNDA ONINGWALL 0 a/ O FOUNDATION MATERIAL CLASS A PER 8'0 CAST IRON STORM LINE C WSDOT /APWA 9 -03.17 ❑ EXISTING 8" 'STORM LINE 3' 3' CB CB '2'0 BLACK STEEL CONDENSATE NOTE: DISCHARGE LINE E CONTRACTOR SHALL SUBMIT SUBMISSION DESIGN DETAILS EXISTING 6" 'STORM LINE FOR. PROPOSED NEW TANK, SUBMISSION SHALL ASSURE \ (TO REMAIN) � FACTOR OF SAFETY WITH RESPECT TO BEARING CAPACITY y E' NEW CONDENSATE VCg UNDER TANK SHELL OF AT LEAST 3.0. COOLER CONTRACTOR SHALL EXPOSE AND VERIFY GRADE CONSTRUCTION : AND UTILIDOR. TRACTOR SECTION ICU OF TANK FOUNDATION �a1 STAGING AREA - CE - SHALL SAW, CUT EXISTING CAST -IN -PLACE CONCRETE Cz L SAW STING C ( C� UTILITY SECTION ABUT NEW PRECAST UTILIDOR SECTION NOT TO SCALE CZ CZ 2 I TO EXISTING: UTIUDOR, AND GROUT NEW UTILIDOR SECTION IN PLACE, ASSURING A WATER TIGHT JOINT. � 2 "m BLACK 10 STEEL MIN. I %2 TEMPORARY ABOVE- PIPE REPLACE PAVING AND BASE H % S GROUND PIPING NEW CONCRETE COURSE TO MATCH EXISTING, F /, SEE NOTE 5 0. UTILIDOR h -N EXCEPT. AS SPECIFIED H SEE SHEET Mi _ ? / SAWCUT TVP, 6" MIN TYP. � 0 10 20 a• rD• SCALE IN FEET — EXISTING CONCRETE UTILIDOR m COMPACTED STRUCTURAL N FILL FOR TRENCH BACKFILL p 6„ BLDG 4 -89 1 LLMAINTAIN CLEAR DISTANCE THROUGHOUT SITE P AN N STEAM PLANT r /'1 BEDDING (PER 9 -03.15 WSDOT/ f DURATION OF PROJECT - APWA 1991 STD. SPEC.) CHECKED FOR COMPLIANCE TO CITY STANDARDS �A SECTION - TYPICAL PIPE TRENCH g_suy,��^atefo 23_g2 NOT TO SCALE 2TI 2 Date Date wefec/ 16 4r-4?­Yf 9vo.yob /e RECOMMENDED RECOMMENDED �DI V FOR APPROVAL FOR APPROVAL J. Ciq BY BY Po„ C HAViTCROWSER �gL S�G�pp ,vns' /1,7 snap«. ,,m ,PLAN Revvs`w 10-2-1•92 5/19/92 C DRAWN BY DATE SUBTITLE SYM REVISION BY PPROVE DATE SYM - REVISION BY PPRDVE DATE ( ACCEPTABILITY EJC LAST REVISION. SYM DATE AUBURN, )✓A' 98002 a 2 92 THIS DESIGN AND /GR REVISIONS PER BOEING REVIEW COMMENTS OF o�q H' K SHEET 01 JUN 92 AND HART CROWSER FINAL REVIEWD /JH MJB 0 JUN 9 ❑ EVERETT, WA. 98201 I PECIFICATION IS APPROVEDAH SITE PLAN AND SECTIONS 2 LNUINEERLD BY TITLE REVISIONS PER CITY OF RENTON REVIEW COMMENTS APPROVED BY DEPT. DATE z JD /JH MJB z1 AUG 9z of 1 O Cl PORTLAND, OR. 97220 0 '4rlcn cam` JAH s 92 rJ REVISIONS PER CITY OF RENTON REVIEW COMMENTS 7Fp,. CHECKED FUEL STORAGE REPLACEMENT OD /JH MJB 14 DCT 92 6r JOB NO. CON FIT F r ®RENTON, WA. 98055 sr pNAL�' sLC 5/7/92 FOR ARECILI - FACILITIES DEPARTMENT O SEATTLE, WA, 98124 APPROVED 305355 FU -DWGq exAIB =s. /, �1 YS RENTON FACILITY pv /,, NO. APPROVED BLDG 4 -89 RENTON 304 -089 1002 �3a� 30'0 NEW DOUBLE -WALL STEEL TANK TO RE ERECTED ON SAME CENTER POINT AS REMOVED TANK CB SEE NOTE 8 A SEE NOTE 7 ME// 2' - I o X SEE I S \ NOTE 5 x CB � I DIESEL TANK PLUG AND SEAL `ST CAST NE - IRO EXISTING 4 "0 DRAIN i STORM LI � LINE. SEE NOTE CAST IRON STORM LINE / `SAW CUT CONCRETE AS REQ'D DRKN TO INSTALL STORM LINE. CONCRETE FUELING PAD AND DN STORM LINE FUEL CONTAINMENT AREA 8 "0 CAST IRON STORM LINE 8 "0 CAST IRON STORM LINE ❑ VALVE BOX • 6'0 SHUT -OFF VALVE NEW CURB—/ CB UTILITY VAULT 3030 -LA I�60 . OR APPROVED EQUAL - EW CURB 15' �'i 0 EL 25.7 FEET - - HOSE • 6 "0 GATE VALVE CAP AND SEAL PLATFORM v • PLUG AND SEAL `ST CAST NE - IRO EXISTING 4 "0 DRAIN i STORM LI � LINE. SEE NOTE CAST IRON STORM LINE / `SAW CUT CONCRETE AS REQ'D DRKN TO INSTALL STORM LINE. CONCRETE FUELING PAD AND DN STORM LINE FUEL CONTAINMENT AREA 8 "0 CAST IRON STORM LINE 8 "0 CAST IRON STORM LINE ❑ REVISION SEE NOTE 2 16.0 140 PROFILE - STORM DRAIN AND CATCH BASINS �F� C3 C3 REVISION, ❑ AUBURN, WA, 98002 ❑ EVERETT, WA. 98201 El KENT WA. 9031 Cl PORTLAND, DR. 98220 ® RENTON, WA. 98055 FACILITIES DEPARTMENT ❑ SEATTLE, WA. 98124 NEW RAMP SEE DETAIL L ON DRAWING C5 K C3 CS M. k- 11' 2" ICB NEW CURB—/ CB j I�60 TO EL. 25.7 FEET 15' 15' �'i x 1 BM 53T SEE NOTE 3 x F C3 C3 CONTRACTOR SHALL EXPOSE AND VERIFY GRADE x O BLACK STEEL LINE / C O AND CONDITION OF EXISTING UTILIDOR. CONTRACTOR TO DESIGN CONNECTION BETWEEN NEW AND EXISTING , UTILIOORS AND SUBMIT TO OWNER FOR APPROVAL x NEW CONDENSATE PRIOR TOCONSTRUCTION... COOLER NEW CONCRETE x 0 2 "m BLACK STEEL DQ N>_ x N 0 10 20 SCALE IN FEET E %ISTING CONCRETE UTILIDOR BLDG 4 -89 STEAM PLANT- _ UTILITY PLAN - _ SCALE 1" -10'. 1 260 METAL FRAME AND GRATE STD PLAN B -2 OF WSOOT. (TYP.) i 24'. OF 6'0 CAST IRON STORM LINE CATCH BASIN TYPE I 24.0 MEETING STD. PLAN B -1 OF WSOOT. (TYP.) 30 x34 "x60 "H MAX.) 22.0 0 70' OF 8'0 _ SLOPE 0.008 CAST IRON. STORM .LINE O SLOPE = 0.005 20.0 CATCH BASIN -TYPE I CATCH BASIN - TYPE TOP EL. 23.9 TOP EL. 23.9. CATCH BASIN - TYPE I. 6" INV. N 21.04 8" INV. N 20.87 18.0 .BOTTOM 20.0± IN 6" V. S 20.69 - TOP EL. 24.7 SEE NOTE 2 6" INV. W 20.90 BOTTOM EL. 19.9*- 8° INV. W20.52 8" INV. S 20.54 SEE NOTE 2 - BOTTOM 19:5± REVISION SEE NOTE 2 16.0 140 PROFILE - STORM DRAIN AND CATCH BASINS �F� C3 C3 REVISION, ❑ AUBURN, WA, 98002 ❑ EVERETT, WA. 98201 El KENT WA. 9031 Cl PORTLAND, DR. 98220 ® RENTON, WA. 98055 FACILITIES DEPARTMENT ❑ SEATTLE, WA. 98124 NEW RAMP SEE DETAIL L ON DRAWING C5 K C3 CS M. k- 11' 2" 12" SQUARE COVERS 24" SQUARE COVER PLAN - OIL /WATER SEPARATOR -(9) C3 "H NOTES: 1. OIL /WATER SEPARATOR SHALL BE PIPE INC. MODEL NO. 5106 -5 MODIFIED OR APRROVED EQUAL. SECTION - OIL /WATER SEPARATOR (b C3 C3 NOTES: L GROUNDWATER AT THIS SITE FLUCTUATES BETWEEN ELEVATION 19 AND 17 FEET. CONTRACTOR MAY HAVE TO DEWATER SOME EXCAVATIONS DURING. CONSTRUCTION. 2. FINISHED GRADE OF CATCH BASINS AND INLETS SHALL BE ADJUSTED TO POSITIVELY DRAIN THE PAVEMENT AREAS. 3, BENCHMARK 53, TOP OF ASPHALT SURFACE AT SOUTHEAST CORNER OF PROJECT SITE. EL. = 24.76 FEET. 1� 4. INSTALL NEW 6" DRAIN WITH REMOVABLE GRATING IN CONCRETE FUEL CONTAINMENT AREA, DRAIN TO COMPLY WITH STD. PLAN 8 -4 OF WSOOT, OR APPROVED EQUAL. 5. PLACE AND COMPACT HOT ASPHALTIC CONCRETE IN THIS AREA TO FACILITATE DRAINAGE OF STORM WATER RUNOFF TO CATCH BASIN. 1� 6. ALL CAST IRON PIPE STORM LINES SHALL HAVE MINIMUM WALL THICKNESS PER A.W.W.A. CLASS 22, 7. REMOVED PORTION OF CONCRETE DIKE CONTAINMENT WALL SHALL NOT BE RECONSTRUCTED AT CONCLUSION OF PROJECT. V 8. SLOPE GROUND SURFACE INSIDE EXISTING CONTAINMET TO DRAIN AT 19 TYPICAL TOWARDS CATCH BASIN. NEW CATCH BASIN ELEVATION 23.6 FEET, PIPE INVERT ELEVATION 21.05 FEET, BOTTOM OF CATCH BASIN AT 20.0 FEET. Ce.�s lvz+cir°d- N Lir -� ./� �va• /�� RECOMMENDED FOR APPROVAL BY D -2070 •2Cwc� wA'/�'R RECOMMENDED � FOR APPROVAL BY /7a—_ H&RTOWRIM PL,+� Ravin /a -z3 -9Z 5/19/92 1BILITY DRAWN Y DATE SUBTITLE r LAST REVISION I SYM I DATE N AND/BR CHECKED "C '/7 9s UTILITY PLAN AND DETAILS SHEET IS APPROVED JAH 5 ] 92 /1 OF 3 DEPT, DATE JAH 5/7/92 TITLE CHECKED FUEL STORAGE REPLACEMENT APPROVED SLG s T ez FOR ARE Loe ND. 305355 FUPDWG# RENTON FACILITY DWG, NO, APPROVED BLDG 4 -89 RENTON 304- 089 -1002 28 28 al BLDG BLDG 4 -89 26 E1 EL 25.1 26 4' -11" NOTES: EST FLOOR E! 25.5 CONTINUOUS 1/4'x2" GALVANIZED EST EL 24.5 STEEL 1. T POSSIBLE, CONSTRUCT STEAM AND FUEL PIPING TO EXIT VAULT AT THIS LOCATION IN ORDER TO AVOID CUTTING VAULT LID. IF NECESSARY ADD VA RISER OBTAIN THE NECESSARY HEIGHT TO ALLOW PIPING TO EXIT THE SIDE WALL OF THE VAULT INSTEAD OF THE LID /COVER. WALL zo 29 EST SUMP EL 23.0 24 _ •. - EXISTING UTILIDOR - < a 2. PROTECT STORM DRAIN LINE BY PLACING AT LEAST 3 INCHES OF STYROFOAM OVER THE PIPE PRIOR TO INSTALLING THE UTILIDOR V SECTION. CONTRACTOR TO TAKE THE NECESSARY PRECAUTIONS TO w -_ _ - - - - -- AVOID DAMAGE TO THE 6 INCH DIAMETER CAST IRON PIPE. - -_ 3, THE EX CT ELEVATION THE EXISTING' UTIUDOR, AT THE POINT WHERE 22 22 - • THE NEW UTILIDOR IS TO BE CONSTRUCTED, IS UNKNOWN. CONTRACTOR TO MATCH THE NEW UTILIDOR FLOOR ELEVATION TO THE FLOOR ELEVATION OF THE EXISTING UTILIDOR IF THAT ELEVATION IS GREATER EST EL 22.0 _ THAN 22.0. OTHERWISE ADJUST SEWER PIPE AND UTILIDOR GRADES AND SUBMIT TO OWNER'S REPRESENTATIVE FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. 20 20 2 "x2 "x1/4" L GALVANIZED STEEL AT TOP OF WALL WITH 1/4'0x4" ' STUDS ® 12" O.C. PROFILE - UTILIDOR NOT TO SCALE G2 G4 SECTION — UTILIDOR K—D� . NOT TO SCALE C2 C4 i� NOTE: UTILIDOR SHALL BE UTILITY VAULT CO. MODEL NO. 5588 TRENCH WITH COVER NO 558T, OR APPROVED EQUAL, VAULT AND COVER TO UI BE FABRICATED TO WITHSTAND AASHO HS 20 LOADING STANDARDS. 26 26 BE 242 I EL 245 I 24 24 - SEE NOTE 3 F 6 NEW UTILIDOR >. - - - - - - - - - - - - - - - - - - - 22 —21.5 q. -0.. NEW VAULT El. 21.7 —20.9 EL 22.0 EL 25.6 /EL 5.1 20 20 6.0 CAST IRON STORM DRAIN SEENOTE 2 EL 24.0 SEE NOTE 1 EL 24.1 S' -5' NEW UTILIDOR PROFILE — UTILIDOR '\ NOT TO SCALE C2 C4 \��\�� •.• EL .25.6 �I ' 26 '. NEW VAULT 26 EL 242 \ \e \\ EL 24.0 EL 24.1 EL 21.6 24 GROUND SURFACE 24 SAWC FABRICATE OPENING NEW UTILIDOR - INTO VAULT . VAULT OUTSIDE z DIMENSIONS: 6' -0" L x 4' -0 "W zz 22 -- _ - -_ - -- 22 -_. ." CAUL O..TO. SEAL, TAR JOINT AND w EL 21.6 EL 21.7 EL 19.6 20 20 RECOMMENDED FOR APPROVAL EL 19.6 SECTION — VAULT rE By 1B 18 NOT TO SCALE cz c4 RECOMMENDED FOR APPROVAL �. L MODEL NO. 660 -L WITH NOTE VAULT SHALL BE UTILITY VAULT CO. PROFILE — UTILIDOR AND VAULT > i COVER No. 64 -366D, OR APPROVED EQUAL BY '��• �` ;PA� v/A i✓ ,c -z9 -92 NOT TO SCALE ',. C2 C4 Con bwd,'.' M. 4—R-11 /va,''Wl,- D-zV749 /uI�-s�w�� ItW1IVIY Ws 5/19/92 REVISION BY PPROVE DgTE SYM REVISION BY PPROVE DATE ` `: ACCEPTABILITY DRAWN BY DATE EJC 5/ / 92 SUBTITLE LAST REVISION SYM DATE 5 PER BOEIN REVIEW COMMENTS OF JD /JH MJB. 4JUN92 ❑ADBURN, - D EVERETT, WA. 98()()2 WA. 98201 �}j'( /� ',�V' THIS DESIGN AND /OR PECIF [CATION IS APPROVED JAH S T 92 UTILIDOR AND VAULT SHEET 4 AN FAR R FINAL REVIEW p D KENT, WA. 98031 �'r ziali� N N -- TITLE 4 OF • ���0� O PORTLAND, OR. 97280 �02,`�_�57m APPROVED BY WEPT. ATE NECKED JAH s 9z FUEL STORAGE REPLACEMENT 5 ■ RENTON, WA. 98055 SLG 57 92 FOR ARE -129 DEB NO. COMP NO. FACILITIES DEPARTMENT D SEATTLE, WA. 98124 "0" IXPIB'.S v RENTON FACILITY 305355 uwc. No. FU -DWGq 1 -30-2070 - — APPROVED BLDG 4 -89 RENTON 304 -089 -1002 /�� - VALVE BOX FOR 6" SHUT -OFF VALVE UTILITY VAULT NO. 3030 -B WITH COVER N0. 3030 -P OR APPROVED EQUAL - 30' OF 6•' 0 CAST IRON 1 6. 0 CAST IRON STORM DRAIN, 22.0 PAD DRAIN' TOP EL 24.0 6" INV N 22.75 < 20.0 6" 0 CAST METAL FRAME AND GRATE MEETING SID. PLAN 8 -20 OF WSDOT CATCH BASIN TYPE I MEETING STD. PLAN B -1 OF WSDOT. (TYP.) (30•'x34 "x60 "H MAX.) O43' OF 8•' 0 CAST IRON STORM DRAIN REVISION PROFILE - FUEL PAD CURB SCALE: 1 " =10' HORIZONTAL C3 CS 1 " =1 VERTICAL REVISION ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 0 KENT ' WA 9eo3l El PORTLAND, OR, 97220 FACILITIES DEPARTMENT - ■ RENTON, WA. 9805° ❑ SEATTLE, WA. 98124 J 7TOP OF EXISTING CURB NEW CONCRETE CURB J T� ZN SECTION CURB NOT TO SCALE CS C5 1'-0" 7'F-#3 0 1'-6" CC DRILL 7/16 "0x3 1/2" DEEP SET WITH EPDXY NEW CONCRETE _TOP OF EXISTING CURB SECTION - CURB N NOT TO SCALE CS CS 2 N 4 BARS CONTINUOUS SEE NOTE 3 - F� NOTES: CATCH BASIN - TYPE I / EXISTING WITH NO. 6 BARS, 14 INCHES LONG, EVERY 12 INCHES. CONTACT _ OWNER'S REPRESENTATIVE TO INSPECT CONDITION OF EXISTING SLAB BEFORE OIL /WATER SEPARATOR EXISTING 2. PRE -CLEAN BY SAND BLASTING AND PRESSURE WASH. RECOMMENDED FO PROVAL USE CONCRETE BONDING AGENT AS WELL AS DOWELS SHOWN. TOP EL 23.9 CATCH BASIN BY 18.0 S -a FAll TOP EL 24.0 6" INV N 21.9 8" NV N 20.40 6" INV E 20.42 TOP EL 23.05 18.0 �., 4. FINISHED GRADE OF CATCH BASINS AND INLETS SHALL BE ADJUSTED TO 6•' INV S 22.4 6'• INV 5 21.85 12 °. INV. W 20.15 . rcq v RevA 0 21. ?Z C nsfnrcy°sd, iVa Aq•Q ./f Lava,% 6/e BOTTOM 19.4! '8" INV. S 19.96 D-jV749 All mumwmim- 5/19/92 1BILITY SEE NOTE 4 8" INV. S:20.20 SUBTITLE LAST REVISION SYM 16.0 , AND /OR UTILITY AND FUEL PAD DETAILS H K AH J 5/7/92 SHEET C 5 OF 5 5 IS APPROVED 14.0 DEPT, DATE N N JAH s 9z 14.0 CHECKED slc 117/12 PROFILE - STORM DRAIN, OIL /WATER SEPARATOR AND CATCH BASINS NOT TO SCALE APPROVED DWG, NO, 304 - 089 -1002 /P,- C3 C5 (> CONCRETE TILLED STEP ON '.. CONTAINMENT PAD O INSTALL NEW CONCRETE CURB I<) UNIFORM NEW 6 CONCRETE 26.0 ELEVATION'OF 25.1 FEET AROUND ENTIRE REINFORCED 26 0 EXISTING CURB PAD ON EAST, SOUTH, AND WEST SIDES ONLY. DRIVE APPROACH - - ON PAD NEW CURB 4x4 6 "x6 "' 25.0 FI 24 A4 SEE NOTE 4 REIFORCING •MESH 250 . _ J1 EL 2451 \\ OPE FOpf 2STj/y l0 �% 5l MF 24.0 E 24.0 REVISION PROFILE - FUEL PAD CURB SCALE: 1 " =10' HORIZONTAL C3 CS 1 " =1 VERTICAL REVISION ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 0 KENT ' WA 9eo3l El PORTLAND, OR, 97220 FACILITIES DEPARTMENT - ■ RENTON, WA. 9805° ❑ SEATTLE, WA. 98124 J 7TOP OF EXISTING CURB NEW CONCRETE CURB J T� ZN SECTION CURB NOT TO SCALE CS C5 1'-0" 7'F-#3 0 1'-6" CC DRILL 7/16 "0x3 1/2" DEEP SET WITH EPDXY NEW CONCRETE _TOP OF EXISTING CURB SECTION - CURB N NOT TO SCALE CS CS 2 N 4 BARS CONTINUOUS SEE NOTE 3 - F� NOTES: 1. SAW CUT CONCRETE AT LIMIT OF DEMOLITION. DOWEL NEW CONCRETE TO EXISTING WITH NO. 6 BARS, 14 INCHES LONG, EVERY 12 INCHES. CONTACT _ OWNER'S REPRESENTATIVE TO INSPECT CONDITION OF EXISTING SLAB BEFORE PLACING NEW CONCRETE. 2. PRE -CLEAN BY SAND BLASTING AND PRESSURE WASH. RECOMMENDED FO PROVAL USE CONCRETE BONDING AGENT AS WELL AS DOWELS SHOWN. BY S -a FAll 3. ALL REINFORCING IS TO BE GRADE 60 STEEL. RECOMMENDED FOR APPROVAL. �., 4. FINISHED GRADE OF CATCH BASINS AND INLETS SHALL BE ADJUSTED TO POSTIVELY DRAIN THE PAVEMENT AREAS BY Da� rcq v RevA 0 21. ?Z C nsfnrcy°sd, iVa Aq•Q ./f Lava,% 6/e D-jV749 All mumwmim- 5/19/92 1BILITY DRAWN BY JD DATE 5 J 92 SUBTITLE LAST REVISION SYM DATE , AND /OR UTILITY AND FUEL PAD DETAILS H K AH J 5/7/92 SHEET C 5 OF 5 5 IS APPROVED DEPT, DATE N N JAH s 9z TITLE FUEL STORAGE REPLACEMENT FOR ARE -129 RENTON FACILITY BLDG 4--89 RONTON CHECKED slc 117/12 JOH ND. 305355 CUMPNU. FU -DWG# APPROVED APPROVED DWG, NO, 304 - 089 -1002 /P,-