Loading...
HomeMy WebLinkAboutzT-2190SetSCHEDULE OF DRAWINGS NO. TITLE 1 COVER SHEET 2 ILLUMINATION PLAN 3 DETAIL SHEET 1 4 DETAIL SHEET 2 ROADWAY ILLUMINATION SHELTON COURT NE N.E. 19TH STREET SUMMARY OF QUANTITIES ITEM NO. TOTAL QUANTITY UNIT ITEM 1 3 EA. STANDARD 25' DAVIT POLE 2 4 EA. TYPE I JUNCTION BOX 3 1 EA. TYPE 11 JUNCTION BOX 4 3 EA. 10OW MC 3 LUMINAIRE 5 450 APPROX. L.F. #8 AWG (USE —XLP) — 2/c 6 50 APPROX. L.F. #10 AWG (USE —XLP) 7 1 EA. ELECTRICAL SERVICE CABINET 8 1 EA. PHOTOCELL 9 350 APPROX. L.F. 2" SCH 40 10 50 APPROX. L.F. 2" SCH 80 11 50 APPROX. L.F. #8 BARE GROUND 12 6 EA. FUSE KIT 13 8 EA. SPLICE KIT T' .qqo r of f — Z1140 IY i 1 I I I Al I I I I I 1 I I I 1 1 SVNS�j GENERAL NOTES LEGEND 1. All work shall be in accordance wrh the City of Renton Standard -tans and Specifications m TYPE I JUNCTION BOX and these plans. (] TYPE II JUNCTION BOX 2. Unless otherwise noted, the location of features shown are approximate and the exact }( LUMINAIRE AND POLE location will be established by the Engineer in the field. Lighting A2 2" (Schedule 80)� ® SERVICE CABINET 3. Install all street lighting materials shown on the plans, except where noted. All materials _ — CONDUIT shall be new and of the best available grade or quality. AI 4 2" ((Schedule 40)� 2 - #8 AWG (USE -XLP) 3 - #10 (USE -XLP) Q WIRE NOTE 4. The contractor shall submit a request to the City of Renton for materials approval at 2 - #8 AWG (USE -XLP) 3 10 (USE -XLP) 1- - # 8 Bare Ground Lighting Photocell Ground the earliest possible date. O CONSTRUCTION NOTE Spare - - -- R.O.W. 5. All work shall be consistent with utility agency requirements. The contractor shall contact Future Ext. to West all pertinent utility agencies 48 hours before commencing work and shall coordinate the work with the utilities throughout the project. 6. The contractor shall be responsible for any damage to existing utilities. The contractor shall notify the affected utility company and the City immediately upon damage_ 7. The contractor shall notify the City of Renton Field Inspection Division (277 -5570) for inspection purposes, 24 hours before commencing work. No work snoll be covered until it has been examined by the engineer. 8. All conduit shall be PVC Schedule 40 unless noted otherwise. 9. All conduit cover shall be 24 inches. CONSTRUCTION NOTES Ol Install new flat lens cobra head 10OW HPS, 240V. Medium Cutoff Type III Distribution on 25' Davit Pole with 6' arm. Also install WSDOT Type I Junction Box (See Standard Plan J -11o) and foundation pad. Pole shall maintain 10' minimum clearance to any driveway. OInstall photocell on luminaire #1. O3 Install Service Cabinet on north side of NE 19th Street between lots 11 and 12 of subject plat. OService Cables (3 - #4's) and Conduit (2" Schedule 40) shall connect from Service Cabinet to nearest Puget Sound Power & Light power source_ WIRING SCHEDULE POLE NO. CONDUIT CONDUCTOR COMMENTS NO. SIZE CIRCUIT NO. COMMENT Al 2" (Schedule 40) 2 - #8 AWG (USE -XLP) Lighting A2 2" (Schedule 80)� 2 - #8 AWG (USE -XLP) Lighting A3 2" ((Schedule 40)1 2 - #8 AWG (USE -XLP) 1 - #8 Bare Ground Lighting Ground AI 4 2" ((Schedule 40)� 2 - #8 AWG (USE -XLP) 3 - #10 (USE -XLP) Lighting Photocell I A 2" (Schedule 40) 2 - #8 AWG (USE -XLP) 3 10 (USE -XLP) 1- - # 8 Bare Ground Lighting Photocell Ground A 1(Schedule 2" 40) OPEN (Pull Wire) Spare 7 2- (Schedule 40)1 OPEN Cap End of Conduit (Pull Wire) Future Ext. to West M rI POLE SCHEDULE POLE NO. POLE I.D. # POLE LOCATION POLE OFFSET MOUNTING HEIGHT ARM LENGTH CIRCUIT NO. COMMENT 1 1537B 1 +34W 20' N 25' 6' A -1 N.E. 19th Street 2 15348 0 +90N 23' RT 25' 61 A -1 Shelton Court N.E. 3 1532B 2 +21N 37' LT 25' 6' q -1 Cul -De -Sac 5' South of Lot 9 10 0 10 20 � I SCALE IN FEET I I J � I 1 I I I 3 2 1 I I I 4 SHELTON 3 COURT N.E. Min. > N #2 I I oS` 2 I f 1 1 00 + 13 1 \ #3 I//� i fn 9 3 10 ' I too 12 I o� I 4 I I W 3 1 I 1 Z # I 5 1 6 4 i I 2 7 1 1 JA I�U EN TS u 1 DATE. �.W-`1S i Y a' a9.. ,. T. 2170 CITY OF RENTON WM POPP ASSOCIA'T'ES Transportation Engineers / Planners First Interstate Ctr.. 314 s 225 108TH AVE. NE BELLEVUE, WA. 98004 (206) 454 -6692 CONTACTOR CABINET SERVICE & CIRCUIT No. MAIN BREAKER BRANCH BREAKER CONTACTOR Service 100 amps — — A- 1/240V — 20 amps 40 amps OrRo- #// —ZI ?O I r I Al I I I Al I 1A I A I A I Al I 1A I I I 1A I I I I I