HomeMy WebLinkAboutzT-2190SetSCHEDULE OF DRAWINGS
NO. TITLE
1 COVER SHEET
2 ILLUMINATION PLAN
3 DETAIL SHEET 1
4 DETAIL SHEET 2
ROADWAY ILLUMINATION
SHELTON COURT NE
N.E. 19TH STREET
SUMMARY OF QUANTITIES
ITEM
NO.
TOTAL
QUANTITY
UNIT
ITEM
1
3
EA.
STANDARD 25' DAVIT POLE
2
4
EA.
TYPE I JUNCTION BOX
3
1
EA.
TYPE 11 JUNCTION BOX
4
3
EA.
10OW MC 3 LUMINAIRE
5
450 APPROX.
L.F.
#8 AWG (USE —XLP) — 2/c
6
50 APPROX.
L.F.
#10 AWG (USE —XLP)
7
1
EA.
ELECTRICAL SERVICE CABINET
8
1
EA.
PHOTOCELL
9
350 APPROX.
L.F.
2" SCH 40
10
50 APPROX.
L.F.
2" SCH 80
11
50 APPROX.
L.F.
#8 BARE GROUND
12
6
EA.
FUSE KIT
13
8
EA.
SPLICE KIT
T' .qqo r of f — Z1140
IY i 1 I I I Al I I I I I 1 I I I 1 1
SVNS�j
GENERAL NOTES
LEGEND
1. All work shall be in accordance wrh the City of Renton Standard -tans and Specifications
m
TYPE I JUNCTION BOX
and these plans.
(]
TYPE II JUNCTION BOX
2. Unless otherwise noted, the location of features shown are approximate and the exact
}(
LUMINAIRE AND POLE
location will be established by the Engineer in the field.
Lighting
A2
2"
(Schedule 80)�
®
SERVICE CABINET
3. Install all street lighting materials shown on the plans, except where noted. All materials
_ —
CONDUIT
shall be new and of the best available grade or quality.
AI
4
2"
((Schedule 40)�
2 - #8 AWG (USE -XLP)
3 - #10 (USE -XLP)
Q
WIRE NOTE
4. The contractor shall submit a request to the City of Renton for materials approval at
2 - #8 AWG (USE -XLP)
3 10 (USE -XLP)
1- - # 8 Bare Ground
Lighting
Photocell
Ground
the earliest possible date.
O
CONSTRUCTION NOTE
Spare
- - --
R.O.W.
5. All work shall be consistent with utility agency requirements. The contractor shall contact
Future Ext.
to West
all pertinent utility agencies 48 hours before commencing work and shall coordinate the
work with the utilities throughout the project.
6. The contractor shall be responsible for any damage to existing utilities. The contractor
shall notify the affected utility company and the City immediately upon damage_
7. The contractor shall notify the City of Renton Field Inspection Division (277 -5570) for
inspection purposes, 24 hours before commencing work. No work snoll be covered until
it has been examined by the engineer.
8. All conduit shall be PVC Schedule 40 unless noted otherwise.
9. All conduit cover shall be 24 inches.
CONSTRUCTION NOTES
Ol Install new flat lens cobra head 10OW HPS, 240V. Medium Cutoff Type III
Distribution on 25' Davit Pole with 6' arm. Also install WSDOT Type I
Junction Box (See Standard Plan J -11o) and foundation pad. Pole shall
maintain 10' minimum clearance to any driveway.
OInstall photocell on luminaire #1.
O3 Install Service Cabinet on north side of NE 19th Street between lots 11
and 12 of subject plat.
OService Cables (3 - #4's) and Conduit (2" Schedule 40) shall connect from
Service Cabinet to nearest Puget Sound Power & Light power source_
WIRING SCHEDULE
POLE
NO.
CONDUIT
CONDUCTOR
COMMENTS
NO.
SIZE
CIRCUIT
NO.
COMMENT
Al
2"
(Schedule 40)
2 - #8 AWG (USE -XLP)
Lighting
A2
2"
(Schedule 80)�
2 - #8 AWG (USE -XLP)
Lighting
A3
2"
((Schedule 40)1
2 - #8 AWG (USE -XLP)
1 - #8 Bare Ground
Lighting
Ground
AI
4
2"
((Schedule 40)�
2 - #8 AWG (USE -XLP)
3 - #10 (USE -XLP)
Lighting
Photocell
I A
2"
(Schedule 40)
2 - #8 AWG (USE -XLP)
3 10 (USE -XLP)
1- - # 8 Bare Ground
Lighting
Photocell
Ground
A 1(Schedule
2"
40)
OPEN
(Pull Wire)
Spare
7
2-
(Schedule 40)1
OPEN
Cap End of Conduit
(Pull Wire)
Future Ext.
to West
M
rI
POLE SCHEDULE
POLE
NO.
POLE
I.D. #
POLE
LOCATION
POLE
OFFSET
MOUNTING
HEIGHT
ARM
LENGTH
CIRCUIT
NO.
COMMENT
1
1537B
1 +34W
20' N
25'
6'
A -1
N.E. 19th Street
2
15348
0 +90N
23' RT
25'
61
A -1
Shelton Court N.E.
3
1532B
2 +21N
37' LT
25'
6'
q -1
Cul -De -Sac
5' South of Lot 9
10 0 10 20
� I
SCALE IN FEET
I
I
J �
I 1
I
I
I
3 2 1 I I
I
4 SHELTON 3
COURT N.E. Min. >
N #2 I
I
oS`
2
I
f 1 1
00
+
13 1
\ #3
I//� i fn
9 3 10 ' I too
12 I o�
I
4 I I W
3 1 I 1 Z
#
I
5 1
6 4 i
I
2
7 1 1
JA I�U
EN TS
u
1
DATE. �.W-`1S i Y a' a9..
,. T. 2170 CITY OF RENTON
WM POPP ASSOCIA'T'ES
Transportation Engineers / Planners
First Interstate Ctr.. 314 s 225 108TH AVE. NE
BELLEVUE, WA. 98004 (206) 454 -6692
CONTACTOR CABINET
SERVICE &
CIRCUIT No.
MAIN
BREAKER
BRANCH
BREAKER
CONTACTOR
Service
100 amps
—
—
A- 1/240V
—
20 amps
40 amps
OrRo- #// —ZI ?O
I r I Al I I I Al I 1A I A I A I Al I 1A I I I 1A I I I I I