HomeMy WebLinkAboutzT-2217SetW
Z
W
z
W
W
O
1 MONIN LASE
STREET
ELEV. 379.44 FEET
S.E. 1/4, SEC. 9, TWN. 23N, Rge. 5E., W.M.
W
z
LJ
1 >
a i
A SEE LIGHTING DETAIL -�
SHEET 53A W
� I
IB.S'R ITYP)
LL
1 38
4 I
37
0.7 5
DECORATIVE STREET (9) PLACES
F-
<•)�
048(0
28
29
30
CONSTRUCTION NOTES
0
i
F-
n
I COR LISHED MON NO. 1502
N ORTHIN 9 I.Eo,.26
EASTING 398907.47
ELEV. 104.057 METERS
THIS PROJECT'S SURVEY
CONTROL POINT
.ELEV. 34139 FEET
MON IN CASE
SEC COR TWP 23N RGE 5E W.M. NE 4TH ST
17711 E;
0
CROWN POINT APTS
0
- -- -, -_ _ S 88'57'59" E 660.63
rx - - -82 — — -J —— - - - - -- - -
— — ——
4 I 1.79
183 84 85 86 87
CONSTRUCTION NOTES
INSTALL NEW FLAT LENS SHOEBOX 150W-HPS, 240V MEDIUM CUTOFF, TYPE I
DISTRIBUTION- DIRECT BURY CONCRETE POLE 25' -0" ABOVE GROUND
INSTALL NEW FLAT LENS COBRA HEAD 10OW HPS, 240V, MEDIUM CUTOFF TYPE 111
DISTRIBUTION ON 30' DAVIT POLE WITH 8' ARM. ALSO INSTALL WSDOT TYPE I ALT E
JUNCTION BOX (SEE STANDARD PLAN J -11 a) AND PAD FOUNDATION BASE 24" DIA x 5'
DEEP.
INSTALL PHOTOCELL ON NEAREST LIGHT POLE.
SERVICE CABINET TO NEARESTPUGET POWER & LIGHT POWER SOURCE, INSTALLSERVICE
CABINET AT STATION 0+60 TRACT B.
INSTALL NEW ACORN DECORATIVE POLE ON 12' POLE - 24" DIA x 4' DEEP POLE BASE
10OW HPS AT 240V.
RO L L'1 4 9 3 3 i�T,�Ar
1
MON 1.nIPE
NE GT I ^IItEET 8 UNION AVE NE
EL EV 0 ' 03.31 FEET
15.
I
- RR SPIKE
I/16 COR SEC 9
TWP 23N RGE 5E W.M.
°I
z.
KB ELECTRIC INC. URBAN DESIGN, INC, CITY O F R E N T O N
P.O. BOX 2964 _ _ _ _
KIRKLAND, WA 98033 611 MARKET STREET, , SUITE 1 -)1C1 AI! 1 MeuT 1:,F RI. 11 •11 OR I(S
(206) 827 -6803 —_--__ - - -- -
KIRKLAND, WA 938033
(206) 822 -4886 V 11 — R AGE O r`� � L XES
STREET LIGHTS 8 MAIL XES
2 'Y
F E
I I PER CITY REVIEW _ 7/10/95
R r.11
L�E2 E..
Al— ur�
�o 1,,.11
-- - •.... ... ..,..—lu r MUNUU(iHFARE LUMINAIRE IS) UNITS
Zl
DECORATIVE STREET (9) PLACES
<•)�
WIRE NOTE (SEE WIRING SCHEDULE -SHEET 53A)
(D
CONSTRUCTION NOTES
0
i
STOP SIGN (2) PLACES
n
MAIL BOXES
z
O
RENTON STANDARD PULLBOX TYPE B
STREET SIGN IT 2) PLACES
ns
— — —
PVC SCHEDULE 40 - 24" COVER
T T ri,
PVC SCHEDULE BO - 24" COVER
NOTE: FOR WIRE SCHEDULE, POLE SCHEDULE AND CONTRACTOR
CABINET, SEE LIGHTING DETAIL SHEET 53A
T-22i7ol
C0F�
NORO
P. IgI.I SHED MON. NO. 1503
IIN. 55189.60
r 4
I EA�YIIINr 399714.51
FILE 122.231 METERS
M0N i ^P
AS
NE 4TH S1-
buic�
A �
SEC "Cr +R TW 23N RGE E WM
KB ELECTRIC INC. URBAN DESIGN, INC, CITY O F R E N T O N
P.O. BOX 2964 _ _ _ _
KIRKLAND, WA 98033 611 MARKET STREET, , SUITE 1 -)1C1 AI! 1 MeuT 1:,F RI. 11 •11 OR I(S
(206) 827 -6803 —_--__ - - -- -
KIRKLAND, WA 938033
(206) 822 -4886 V 11 — R AGE O r`� � L XES
STREET LIGHTS 8 MAIL XES
2 'Y
F E
I I PER CITY REVIEW _ 7/10/95
R r.11
L�E2 E..
Al— ur�
�o 1,,.11
GENERAL NOTES
1. All work shall be in accordance with the National Electric Code and these plans.
2. Unless otherwise noted, the location of features shown are approximate and the exact location
will be established by the Engineer in the field.
3. Install all street lighting materials shown on the plans, except where noted. All materials shall
be new and of the best available grade or quality.
4. The contractor shall submit a request to the City of Renton for materials approval at the earliest
possible date.
5. All work shall be consistent with utility agency requirements. The contractor shall contact all
pertinent utility agencies 48 hours before commencing work and shall coordinate the work with
the utilities throughout the project.
6. The contractor shall be responsible for any damage to existing utilities. The contractor shalt
notify the affected utility company and the City immediately upon damage.
7. The contractor shall notify the City of Renton Field Inspection Division (277 -5570) for
inspection purposes, 24 hours before commencing work. No work shall be covered until it has
been examined by the engineer.
8. All conduit shall be PVC Schedule 40, except for street crossings, which will be PVC schedule
80.
9. All conduit cover shall be 24 inches minimum.
10. Minimum conduit is 1 1/2 ".
11. Pole numbers will be designated by City of Renton. Private poles will be preceded by the
Letter "P "
12. Ali pole cable to be 10/2 stranded bracket cable.
13. Each pole to be grounded and bonded as per N.E.C. ground to return to main isolated ground
bus in service center.
14. All lighting conduit to be routed under sidewalk - then to pole or pole base behind sidewalk.
WHU NG SCHEDULE
Circuit No.
CONDUIT SIZE
CONDUCTOR
COMMENTS
*A
1.5" Sch. 40 PVC
#t 248 THHN
Lighting
%
VOLT
DROP
I
1 -910 Ground
0+34
2
1.5" Sch. 40 PVC
2-48 THHN
Lighting
1
.04
1-#10 Ground
P0053C
3
1.5" Sch. 40 PVC
2 -#8 THHN
Lighting
Post top
1
1410 Ground
3
4
13" Sch. 40 PVC
2 - - #S THHN
Lighting
25'
10"
1-#10 Ground
.38
5
2" Sch 40 PVC
3- #2 THHN
service
# 1 2 17. 1 #10 GRND FROM CC TO POLE #9
2 #8 & 1 910 GRND FROM POLE 9 TO 13C
EPDXY FILL EPDXY FILL
INLINE SPLICE
WYE SPLICE
col Ir"C IZIT
FUSE KIT I SPLICE KIT DETAILS
DIAMETER = 7/0 I.n #w
O
ADOPTED
�4 -7/8 "-mil DWG. NAME: JR -12" e SP PACE: J013
LOAD LINE
POLE
NO.
1/4" FUSE
FUSE KIT SEC. 1791-SF
POLE
LOCATION
POLE
OFFSET
MOUNTING
HEIGHT
ARM
LENGTH
CIRCUIT
NO.
%
VOLT
DROP
I
POOSIC
0+34
y
POLESCHEDULE
POLE
NO.
POLE
I.D.#
POLE
Sta.
POLE
LOCATION
POLE
OFFSET
MOUNTING
HEIGHT
ARM
LENGTH
CIRCUIT
NO.
%
VOLT
DROP
I
POOSIC
0+34
Tract B
22'
12'
Post top
1
.04
2
P0053C
T 4
Tract B
20.5'
12'
Post top
1
.17
3
P0055C
0 +75
Lot 48 NW
20.5'
25'
10"
1
.38
4
P0057C
414V
Lot 48 S
20.5'
25'
10"
1
.52
5
P0059C
1 +50
Lot 50
20.5'
25'
t0"
1
.87
6
P0061C
2�+
Lot 52
20.5'
25'
to,,
1
1.16
7
P0063C
+�6774�
i+BU-
rot 54
20 S'
25'
10"
1
1.44
8
P0065C
4 +92
Lot 56
20.5'
25'
10"
1
1.70
9
P0067C
4+-I&
Lot 58
20.5'
25'
10"
1
1.93
10
P0066C
Lot 60
20.5'
12'
Post top
1
2. I S
11
P0068C
6+92
Lot 60
20.5'
12.'
Post top
1
2.19
12
EP00�72C C_
Lot 59
20.5'.
12'
Post top
1
2.24
13A
-7fi33-
Tract G
24'
- 12'
Post top
1
2.26
13B
P0074C
- }+89 -7
Tract G
32''
Sti
Post top
1
2.29
13C
1758C
7+90
Tract G
41'
30'
8'
1
2.30
14
P0069C
1 +79
Lot 82
21'
25'
10"
2
.88
15
P0071C
2 91
Lot 79
20.5'
25'
10"
2
1.28
16
P0076C
9+34
Lot 77 NW
20.5'
25'
10"
2
1.58
17
P0078C
1 +28
Lot 77 SE
15,
25'
10"
2
2.00
18
P0080C
I.
Lot 72
20.5'
25'
10"
2
2.30
19
P0082C
g+23-
Lot 71
20.5'
25'
10"
2
2.47
20
P0084C
3+3EF
Let 69
20.5'
25'
10"
2
2.61
21
P0075C
-0++F
Lot 66
20.5'
25'
10"
2
2.74
22
P0073C
Lot 65
20.5'
25'
10"
2
2.77
23
P0050C
0 +39
Tract A
22'
12'
Post top
3
.02
24
P0052C
�+N-
Tract A
20.5'
12'
Post top
3
.25
25
P0054C
0
Lot 12
20.5'
25'
10"
3
.60
26
P0077C
s
-
Lot 13
20.5'
25'
IO"
3 �
.84
27
P0079C
p�H�{r674-
Lot 15
20.5'
25'
10"
3
1.05
28
P0086C
Lot 18
20.5'
25'
10"
3
1.22
29
P0088C
�+++S
-F+6&Z
Lot 21
20.5'
25'
10"
3
1.36
30
P0090C
- +8�
Lot 23
20.5'
25'
10"
3
1.49
31
P0092C
s+
3199-
Lot 26
20.5'
25'
10"
3
1.53
32
P0106C
3+ih3
Lot 39
20.5'
25'
10"
4
.95
33
P0104C
+ 7
Lot 36
20.5'
25'
10"
4
1.21
34
POIOOC
2 +33
Tract D N
20.5'
25'
10"
4
1.46
35
P0102C
4 +25
Tract D NE
20.5'
25'
1o"
4
1.64
36
P0098C
1 7o
Tract D NW
20.5'
25'
10"
4
1.77
37
P0096C
at
91531-
Lot 30
20.5'
25'
10"
4
1.90
38
P0094C
0 +75
Lot 28
12'
25'
10"
4
1.93
39
P0108C
of
Let
18.5'
30'
8'
3
.38
40
POI IOC
-L�33
Let 7
18.5'
30'
8'
3
.35
41
POI 12C
3 +22
Lot 11
18.5'
30'
3
.22
42
Poll 14C
5 +57
Lot 46
18.5'
30'
8'
1
.04
12'
- AT23 -8" NECK ACORN GLOBE
)0 WATT HPS -MG STD. BASE SIZE
3LACK FINISH
W12117 -CA /BK
ECORATIVE STREET
LIGHT STANDARD
(TYPICAL 9 LOCATIONS)
CONTACTOR CABINET
SERVICE &
CIRCUIT NO.
MAIN
BREAKER
BRANCH
BREAKER
CONTACTOR
COMMENTS
SERVICE
100 amps
MB0 -7
23'071000 MEO -6
24'- 7'/1150
Circuit 41 -2P, 240V
M80 -7.5
20 amps
30 amps
47'
Circuit 42 -2P, 240V
27'11'/1330 MEO-7.5
20 amps
30 amps
M80 -9
Circuit #3 -2P, 240V
32'10'/1570
20 amps
30 amps
32'10 "/1670 MEO -g.4
Circuit #4 -2P, 240V
5'2"
20 amps
30 amps
1 40'072100
4' SIDEWALK
ta'
2TLITY NT
14' 14
SECTION A -A
Ni
Centrecon Series
"Mrr Medium Square Pole
Mounting Height - 23'0" - 40'0"
Ameron Centrecon Series "M" prestressed concrete lighting poles provide the
light pattern required for shopping centers, parking lots, green belts or other areas
requiring decorative and roadway lighting. Application can be post top, mast arm
or side mounted. These strong, durable poles are available in various aggregates
and finishes.
MRO Anrhnr Raca. V_ 1mM1OAAO1 n IA4�C_
Pole
Leni Pale
Length/
Embedded
Number
Weight Number
Weight
Depth
MB0 -7
23'071000 MEO -6
24'- 7'/1150
5'0'
M80 -7.5
24'7'/1120 MEO-7
277/1250
47'
Me0 -2.5
27'11'/1330 MEO-7.5
29'6'/1350
4'11" eg
M80 -9
29'6 "/1450 MEO -8.5.
32'10'/1570
4'11'
MB0 -10
32'10 "/1670 MEO -g.4
36'0/1780
5'2"
MB0 -11
36'1'/1880 MEO -10.6
1 40'072100
5'10'
M80 -12.2
40'0" /2150 MEO -12.2
1 49'3'/2760
913'
Appearance Code
Aggregate /Finish
Cement Color
Gray White
rawn
Black
N.Wnsi /Mold finish
4111 9211
NatureVPOlished
4112 #212
512
0612
Natural /Exposed
4113 9213
#513
#613
Tenazzo /Polished
4122 0222
a#4
#522
#622
Tenauo /Exposed
4123 4223
4523
#623
Sonora Gold/POlished
9232
Sonora GOld/Exposed
Ordering information g
MEO -7.5 �
M E 0 - 8.5 1213)0 Ta S SO
III P/ I v - 1 VI II
P"c D =sign tixri Aran D�,icn-lcn
I - Sales, mounting height dcs ma: -;hic is usually dictated by the hype of
lumincirs and degree or illumination required.
II - Select tenon size or side mount as required by fixture.
III - Select pole which will give proper mounting height with type of arm selected.
IV - Select footing requirements- anchor base or embedded style.
V - Select shape of pole- round, octagonal, square.
VI - Select finish from appearance codes,
MAGNUFO SMO 1H
RCS SERIES - RECTANGULAR CUTOFF LUMINAIRE - HPS RCS -A- 1505 -3P
The Magnuform III Series offers an aesthetically -styled
rectangular housing with sharp cutoff for a variety of
distributions for any lighting application. With a wide range
Of optical assemblies the RCS Series is ideal for shopping
centers, parking areas, malls, commercial and industrial
complexes, roadway, or any area where luminaire styling
contributes to the visual environment. The RCS unit is
available in 100 -400 waft HPS and 175 -400 Metal Halide.
Housing - Lightweight, rugged one -piece formed and
welded aluminum insures smooth construction and
weatherproof integrity. The luminaire is pre- drilled for
mounting to pole or wall.
Ballast - 1 BO °C insulation, -20 °F starting )-40 °F, HPS),
60 Hz HPF ballast. 50 Hz ballast available - contact
factory.
Lens Door Frame - Extruded frame with rigid corner
bracing and die -cast zinc latches to permit tool -less entry
for servicing. The door has high quality silicone gasketing
to seal against entry of insects, din and moisture.
D I ' ecorative silkscreening provides for concealment of
DIMENSIONS O sp.
e ectncal compartment. I�
Lens - Flat, tempered and impact resistant glass.
LEKTROCOTE® Finish - Two mils minimum of
.2' electrostatically applied powder coating, high temperature
,__.._26' RLGIIOF_WAY bonded to the surface for maximum adherence and finish no mmt in. s' UTILITY hardness. Standard finishes are bronze, black, gray and
EASEMENT white. See ordering information.
S'
_ Additional Features - Full
EASEMENT operation. U.L. 1572 listed and suitable for wetllocati locations, --
C.S.A. certified for outdoor use. IP suitability - IP55. �- lssi /nm1
SECTION B -B
70 l.
N.T.S. oe WAS /r'V 1 _
pr 1
ee' RIGHT of WAY w- 221
G,. 1 J LJ IPjamml
3o'E %. RIGHT oF_ WAY_ __ ___. , a§'. TEDICATIMI 1
STATto We LINE 34' PLANTER b, SDEWALK rGy-I6
-,.7- rwASA 01 /01!96 J
S BUILT
SECTION C -C
N.T.S. I 110PAI'd nGCU_AI imi ...�., .,-
331