HomeMy WebLinkAboutzT-2241SetIDOADWAY ILLUMtNATtON
PLAT OF T.. COLINA
RENl O WASHtNGTn)N SCHEDULE
OF nRp\n/INGS
SHEET NO. TITLE
1 COVER SHEET
2 ILLUMINATION PLAN (1 OF 4)
3 ILLUMINATION PLAN (2 OF 4)
4 ILLUMINATION PLAN 3 OF 4
•
ro zz
r7 Or
by
N
ai
( )
VICINITY MAP
5
ILLUMINATION PLAN (4 OF 4)
RECOMMENDED
FOR APPROVAL
70.
BY DATE p�������S
LATE �i
6
NOTES
-si-q
BY DATE
7
WIRING DIAGRAM, CABINET A
Il 9
94Ix19
BY DATE -
BY DATE
1J
WIRING-DIAGRAM, CABINET B
D AS
`Z`
O I TY OF R E N T O N
C)EPARTMENT OF PUBLIC WORKS
9
ILLUMINATION, DETAILS (1 OF: 2)
,aD,D
coyer Sheet
1 0
'
ILLUMINATION D ETA I L S (2 O F 2)
XR: APRIL 24.2,
Roadway Illumination
Plot of LaC .
DESICrvE N
SepC2mber 199 9
DRANK D. HAMLIN
DAB
Fl LE NO
!,TiQe — oc✓ " 22+lL �
CHECKED
scE' NO_ NFE6
sooK_ PnDE_
.
NO.
REVISION
''�. BY
APPR.
DA"fE
APPROVED
9HEFr OF D,..
•
ro zz
r7 Or
by
N
ai
D
r
3
r
r
r
r
GENERAL NOTES
EE SHEET 6 FOR LUMINAIRE SCHEDULE, CONSTRUCTION NOTES, AND WIRE NOTES.
EE SHEETS 7 AND 8 FOR WIRING DIAGRAMS.
EE DETAIL SHEETS FOR MISCELLANEOUS DETAILS.
_L FINAL POLE LOCATIONS SHALL BE APPROVED BY THE OWNERS'. REPRESENTATIVE PRIOR
CONSTRUCTION.
0' 30' 60'
CABINET NO.\ /CIRCUIT NO.
\ / LUMINAIRE NO.
yA1�G -1 Z
AL `2
AM
AV
704LZ?441ww
LEGEND
® SERVICE VAULT (PSE)
I� LIGHTING CONTACTOR CABINET
LUMINAIRE POLE
/ i ®\ TYPE 1 JUNCTION BOX
CONDUIT
0 CONSTRUCTION NOTE
A WIRE NOTE
PSE TRENCH
CITY OF RENTON
DEPARTMENT OF PUBLIC WORKS
AL
Illumination Plan (1 of 4)
: . Rnnrl .. n.i Illmin n +'.nn
I PROVED. SHEEitlV'Z OF 'I
p.O.
NO. REV 310N 6Y APPR. OATS AP
z z a /vz SCANNEO MAR 3 0 2000
i7
..
i»r
Sn ^1
a
B y
N
N
4
>v
u
T
ACC
3
MOUNT OLIVET
PLAT OF CEMETERY
MONTEREY TERRACE
GENERAL NOTES
1. SEE SHEET 6 FOR LUMINAIRE SCHEDULE, CONSTRUCTION NOTES, AND WIRE NOTES.
2. SEE SHEETS 7 AND 8 FOR WIRING DIAGRAMS.
IETAILS.
;OVED BY THE OWNERS' REPRESENTATIVE PRIOR
CABINET N0. X `CIRCUIT N0.
/ LUMINAIRE NO.
A1{` -1
z
In
M
M
rn
r1?
T-1
LEGEND''
\ Il \
-
SERVICE VAULT (PSE)
®
LIGHTING CONTACTOR CABINET
TRACT G 88
89
/!
LUMINAIRE POLE
TYPE 1 JUNCTION BOX
4 LANDSCAPE/
OPEN SPACE 87
CABINET B
- --
CONDUIT
O
CONSTRUCTION NOTE
,ao,a
�wv�
A
WIRE NOTE
- —
PSE TRENCH
z
In
M
M
rn
r1?
T-1
y
�d
b o
�
d
a �..�
�y
y
ti
12 \
\ Il \
-
RECOMMENDED
FOR APPROVAL
43
\
`
.. \
TRACT G 88
89
/!
BYQ DATE
BY DATE
BY DATE
BY DATE
BY DATE
2 s, /
4 LANDSCAPE/
OPEN SPACE 87
CABINET B
g�9°s easg�Q:lr
CITY OF RENTON
VI. s .DEPARTMENT OF PUBLIC WORKS
BZ 1
13
1
,ao,a
�wv�
Illumination Plan (2 of 4)
4 E(
Roadway Illumination
EtiSN�
IXPIRESf APeluza,zom
Plat of LaColino
44
S .
DESIoNm D HAMLIN
n. HAMLIN.
DAh September 1999
FILE NO
CHECKED
SCALE NONE
F,ELD BOOK_ PAGE_
NO.
REVISION
BY
APPR.
DATE
APPROVED
SHM 3 OF-8—
_ - -- = - - - -- -
G7; 7-- .?2W03 SCANNED', MAR 302000
MI��Gutr
E1
€€' ku6a.;l
�y
y
�d
b o
�
d
a �..�
�y
y
ti
- RUCTION NOTES, AND WIRE NOTES.
LS.
D BY THE OWNERS' REPRESENTATIVE PRIOR
v�
u
i
=T NO. \ /CIRCUIT NO
/ LUMINAIRE NO.
yA1{` -1
LEGEND
99 BY D
q19 yt. as 'ate
0. 30 60 qF yam CITY OF RENTON
.DEPARTMENT 0 F PUBLIC WC
Illumination Plan (3 of 4)
Roadway Illumination
ePlrsrs: A IL24.201 1 Plot of'LaColina
DESIGNED D. HAMLIN se tember 1999
.... DATE P FlLE NOS
cNEcr D. HAMLIN
scALE. NONE cIFI.o a�DI
TRo —f� i — zzrf'i
NO. REVISION 9Y APPR: DATE 0. PROVED SHEE? 4
- wioY SCANNED MHIt 3- 9 'CUUO
d>
z°
z
a
b
lw �
lv
ti
1�
SERVICE VAULT (PSE)
LIGHTING CONTACTOR CABINET
LUMINAIRE POLE
®
TYPE 1 JUNCTION BOX
- -
- --
CONDUIT
O
CONSTRUCTION NOTE
A
WIRE NOTE
—
—
PSE TRENCH
RECOMMENDED
r44244104
FOR APPROVAL
BY DATE
BY. ._DATE
BY — DATE
BY DATE
99 BY D
q19 yt. as 'ate
0. 30 60 qF yam CITY OF RENTON
.DEPARTMENT 0 F PUBLIC WC
Illumination Plan (3 of 4)
Roadway Illumination
ePlrsrs: A IL24.201 1 Plot of'LaColina
DESIGNED D. HAMLIN se tember 1999
.... DATE P FlLE NOS
cNEcr D. HAMLIN
scALE. NONE cIFI.o a�DI
TRo —f� i — zzrf'i
NO. REVISION 9Y APPR: DATE 0. PROVED SHEE? 4
- wioY SCANNED MHIt 3- 9 'CUUO
d>
z°
z
a
b
lw �
lv
ti
1�
CrJ T- "Cc/ 0S grLimbtcn MAR 3'A MR
y
�d
�r
a
�y
.. N
y
LUMINAIRE SCHEDULE
CITY OF RENTON
LUMINAIRE I.D.
NUMBER (1)
CABINET
I.D.
CIRCUIT
N0.
LUMINAIRE
NO.
LAMP
WATTAGE
POLE
LOCATIO
z OF POLE
TO
CURBFACE
MOUNTING
HEIGHT
ARM
LENGTH
REMARKS
EDMONDS AVE. N.E.1
DAYTON AVE. N.E.
ICAMAS AVE. N.E.
BLAINE DR. S.E.
S.E. 2ND PL.
S.E. 2ND CT.
S.E. 3RD ST.
4411 B
A
1
1
100 WATT
19 +90 LT
—
A3
2 NO. 8 (ILLUM)
2" PVC
15 2P
—
7 FT.
25 FT_
8 FT.
TYPE III LIGHT DISTRIBUTION
4413B
A
1
2
100 WATT
1 -1/2" PVC
3 NO. 14 (PEC)
10 +37 LT
7 FT.
25 FT_
8 FT.
TYPE III LIGHT DISTRIBUTION
44158
A
1
3
100 WATT
A6
2 NO. 10 (ILLUM)
1 GREEN NO. 8 (GND)
9 +27 LT
TYPICAL ALL NON —PEC— EQUIPPED LUMINAIRES.
(34 PLACES).
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
44178
A
1
4
100 WATT
6 NO. 8 (ILLUM)
3 NO. 14 (PEC)
2" PVC
7 +62 LT
1 GREEN NO. 8 (GND)
7 FT.
25 FT.
8 FT_
TYPE 111 LIGHT DISTRIBUTION
4428B
A
1
5
100 WATT
6+ 30 LT
7 FT.
25 FT.
8 FT_
TYPE III LIGHT DISTRIBUTION
4430B
A
1
6
100 WATT
4 +56 LT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
44198
A
1
7
100 WATT
13 +36 LT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4422B
A
1
8
100 WATT
14 +97 RT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
4420B
A
1
9
100 WATT
16+60 RT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4424B
A
1
10
100 WATT
3 +63 LT
7 FT.
25 FT_
8 FT.
TYPE III LIGHT DISTRIBUTION
4426B
A
1
11
100 WATT
2 +02 LT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4418B
A
1
12
100 WATT
18 +03 RT
7 FT.
25 FT.
8 FT_
TYPE III LIGHT DISTRIBUTION
4410B
A
2.
1
100 WATT
12 +38 RT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
44126
A
2
2
100 WATT
13 +72 RT
7 FT.
25 FT.
E FT.
TYPE III UGHT DISTRIBUTION
441 46
A
2
3
100 WATT
14 +89 RT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
441 6B
A
2
4
100 WATT
16+11 RT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4462B
A
2
5
100 WATT
21-4-13 RT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
4464B
A
2
6
100 WATT
22 +69 RT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
4466B
A
1 2
7
100 WATT
24 +65 RT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
44688
A
2
8
100 WATT
25 +88 RT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
4421B
B
1
1
1 00'WATT
11+15 LT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
4436B
B
1
2
100 WATT
1 +42 LT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
4438B
B
1
3
100 WATT
2 +94 LT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
4440B
B
1
4
100 WATT
4 +88 LT
7 FT.
25 FT. !
8 FT.
TYPE III LIGHT DISTRIBUTION
4442B
B
1
5
1 00 WATT
5 +98 LT
7 FT.
25 FT.
8 FT.
TYPE' IH UGHT DISTRIBUTION
4444B
B
1
6
100 WATT
7 +97 LT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4446B
B
1
7
100 WATT
9 +38 RT
7 FT.
25 FT.
8 FT_
TYPE III LIGHT DISTRIBUTION
4448B
B
1
8
100 WATT
11 +1 0 RT
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4450B
B
2
1
100 WATT
12 +70 RT
7 FT.
25 FT.
8'FT.
TYPE III UGHT DISTRIBUTION
4452B
B
2
2
100 WATT
14 +00 RT
7FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
4454B
B
2
3
100 WATT
15+46 RT
7 FT.
25 FT.
8 FT.
TYPE III UGHT DISTRIBUTION
4456B
B
2
4
100 WATT
16+71 RT 1
7 FT.
25 FT.
8 FT.
TYPE III LIGHT DISTRIBUTION
4458B
B
2
5
100 WATT
18+11 RT
7 FT.
25 FT.
8 FT_
TYPE III UGHT DISTRIBUTION
4460B
B
2
6
100 WATT
19 +66 RT
7 FT.
25 FT.
8 FT-
TYPE III UGHT DISTRIBUTION
4434B
B
2
7
100 WATT
1+43 LT
7 FT.
25 FT.
8 FT_
TYPE III LIGHT DISTRIBUTION
4432B
B
2
8
10 WATT 1
2 +87 LT
7 FT.
25 FT.
8 FT_
TYPE III LIGHT DISTRIBUTION
I
(1) NUMBER TO BE AFFIXED TO POLE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAIL
(SEE SHEET 9).
CONSTRUCTION NOTES
1O CONSTRUCT SERVICE /ILLUMINATION CABINET FOUNDATION. INSTALL SERVICE /ILLUMINATION
CABINET WITH METER BASE (SEE SHEET 10).
O2 CONSTRUCT LUMINAIRE POLE FOUNDATION (SEE LUMINAIRE POLE SCHEDULE FOR LOCATION,
SEE SHEET 10 FOR FOUNDATION DETAIL). INSTALL LUMINAIRE POLE AND LUMINAIRE.
INSTALL TYPE 1 JUNCTION BOX AND CONCRETE PAD (SEE SHEETS 9 & 10). TYPICAL 34
PLACES,
O CONSTRUCT LUMINAIRE POLE FOUNDATION (SEE LUMINAIRE POLE SCHEDULE FOR LOCATION,
SEE SHEET 10 FOR FOUNDATION DETAIL). INSTALL LUMINAIRE POLE AND LUMINAIRE WITH
INTEGRAL PHOTO— ELECTRIC CELL. INSTALL TYPE 1 JUNCTION BOX AND CONCRETE PAD (SEE
SHEETS 9 & 10).
O4 INSTALL TYPE 1 JUNCTION BOX (SEE WSDOT STD. PLAN J -11 a & SHEET 10).
05 CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH PUGET SOUND ENERGY REQUIREMENTS.
TRo - ft / -2z�rj
I
WIRE NOTES
RUN
CONDUCTORS
CONDUIT
COMMENTS
REMARKS
3 NO. 2 (POWER)
2" PVC
—
—
1 GREEN NO. 8 (GND)
1 ILLUM
—
A2
4 NO. 8 (ILLUM)
2" PVC
2 ILLUM
—
1 GREEN NO. 8 (GND)
30
240 VOLT
3 SIGN LTG
3 NO. 14 (PEC)
20 1 P
—
A3
2 NO. 8 (ILLUM)
2" PVC
15 2P
—
1' GREEN NO. 8 (GND)
3 NO. 14 (PEC)
A4
2 NO. 10 (ILLUM)
1 -1/2" PVC
3 NO. 14 (PEC)
1 GREEN NO. 8 (GND)
2 NO. 8 (ILLUM)
2" PVC
1 GREEN NO. 8 (GND)
A6
2 NO. 10 (ILLUM)
1 GREEN NO. 8 (GND)
1 -1/2" PVC
TYPICAL ALL NON —PEC— EQUIPPED LUMINAIRES.
(34 PLACES).
Z7
4 NO. 8 (ILLUM)
2" PVC
1 GREEN NO. 8 (GND)
A8
6 NO. 8 (ILLUM)
3 NO. 14 (PEC)
2" PVC
1 GREEN NO. 8 (GND)
NOTE: LATERAL CONDUITS SHALL BE PVC SCH: 40.
STREET CROSSINGS ARE EXISTING. CONTRACTOR SHALL CONFIRM LOCATIONS OF ALL
EXISTING CONDUITS PRIOR TO CONSTRUCTION.
NEW STREET CROSSINGS SHALL BE PVC SCH 80.
SERVICE CABINET A (I.D. NO. 0030)
BREAKER AND CONTACTOR SCHEDULE
CIRCUIT
NO.
MAIN BREAKER
AMPS
BRANCH BREAKER
AMPS
CONTACTOR
AMPS
REMARKS
MAIN
100
—
—
120/240 VOLT
1 ILLUM
—
20 2P
30
240 VOLT
2 ILLUM
—
20 2P
30
240 VOLT
3 SIGN LTG
—
20 1 P
—
120 VOLT
4 IRRIG
—
15 2P
—
120V
SERVICE CABINET B (I.D. NO. 0031 )
BREAKER AND CONTACTOR SCHEDULE
CIRCUIT
NO.
MAIN BREAKER BRANCH BREAKER
AMPS AMPS
CONTACTOR
AMPS
REMARKS
MAIN
100
—
—
120/240 VOLT
1 ILLUM
—
20 2P
30
240 VOLT
2 ILLUM
—
20 2P
30
240 VOLT
3 IRRIG
—
15 1 P
—
120V
c u; i J2ui0e SCANNED MAR 3 0 2040'.
r
.�I
0a �
H
�I
I
ti
Al -4 Al -3
t (t Al -2
2N0' 8 2 NO. 8 2 N0. 8
Al -5 TYPE 1JB TYPE IJB
't
TYPE 1JB,F TYPE 1JBI Al -1 2 NO. 10
TYPICAL ALL LUMINAIRES
�TO SERVICE POINT
TYPEIJB � PEC N
2NO.8'
z
--
TYPE 1JB SERVICE /ILLUMINATION CABINET A
— — —
' METER
2 NO. 8 BASE
2 NO. 8 ILLUM CKT 1
TYPE_1JB A7 -12
Al -6 2 NO. 8 ILLUM CKT 2
� '
3 NO. 14
PHOTO -CELL
i Al -8 Al -9 TYPE 1 JB - - -f '
- -,
TYPE 1,113 2 N0. 8
-, 2 N0. 8 TYPE 1 JB t A2 -1
( TYPE 1JB TYPE 1JB; '
2 N0. 8 2 N0. 8 ' - -' TYPE 1JB -
TYPE 1JB TYPE 1JB- - 00
0
Ai -7 Z
N
Al -10
TYPE 1JB; ' J
A2 -2'
TYPE 1JB;
co
co
o °
z z
,
Al -11 A2 -3
TYPE 1JB; TYPE 1JB; ;
0
z
A2 -5
N A2-4
TYPE1JB
t
TYPE 1JB
T'PE�1JB 00 00
6 0 74424107
N i t N
� _1
TYPE JJB
00
0
z
N
A2 -7 /
TYPE 1 JB,
qA�9 st�esg�'et�
F� N �� CITY OF- F
E)EPARTMENT CI
m �s Wiring Diagran
0
z Roadway IIIu
N A2 8 fl( IM: APRO.24.200, Plat of La
OMINED D. HAMLIN DATE Septemt
TYPE 1 JBi i D. HAMLIN
TWO- 4 / -12fi/
cNRL10E0 �_.-'Q -- ScAie NONE
. NO. REVISION HY APPR. DATE APPROVED
SCANNEq MFR 3 0 2000
H
i7r
0
N
N
'1
a
ti
If
B1 -5 B1 -4
2 NO. 8
TYPE 1 JB 131-6 - 2 NO. 8
TYPE 1 JB TYPE 1 JB
TYPE 1 JB 131 -3
TYPE1JB
B1 -7 00
c
z
N O
N
i
TYPE 1 JB
B1 -8 TYPE 1 JB B1 =2
TYPE T JB -
�a
2 NO. 8—
2 NO. 8 _!TYPE 1 JB
B1 -1'
TYPE 1 JB TYPE 1 JB
-- ; 3 NO 2 TO SERVICE POINT
PEC L_ _ __' SERVICE /ILLUMINATION CABINET B
2 NO. 8 METER BASE !
132 -1 2 N0. 8 ILLUM CKT 1
2 NO. 8 ILLUM CKT 2 132 -8
3 NO. 14--1 PHOTO =CELL TYPE 1 JB; ;
L aD
2 NO. 10
TYPICAL ALL LUMINAIRES Z:
N B2 -7
TYPE 1 JB; ; J
2 NO. 8 TYPE 1 JB!
B2 -2
-
TYPE 1 JB B2 -3 132 -4 0 B2 -5 132 -6
z
N
2 N0. 8 ' 2 N0. 8 2 N0. 8 ' 2 NO. 8"- 7.4241,0,0
TYPE 1 JB TYPE 1 ,JB TYPE'1 JB TYPE '1 JB
b e>
0 n
m -Di
ti
N
SERVICE CABINET FOR ILLUMINATION AND TRAFFIC SIGNAL
SKYLINE ELECTRIC & MFG. CO. MODEL NO. 47700 -R
COMPONENT SCHEDULE
OMETER'BASE: 100 AMP, 4 JAW, A. W. NO. 1 21 314 WITH BYPASS BLOCKS.
(CONTRACTOR TO VERIFY WITH SERVING UTILITY).
OPANELBOARD: 120/240 VAC, 100 AMP, 1 PHASE, 3 WIRE, COPPER BUS.
WESTINGHOUSE BAB BOLT -ON BREAKERS:
1 - 100/2 MAIN
1 - 20/2 ILLUMINATION BRANCH BREAKER
1 - 15/1 CONTROL CIRCUIT BRANCH BREAKER
O3 CONTACTOR: LIGHTING RATED, 2 POLE, 120 VAC COIL, TE /GOULD NO. 2200EBy320AA
1 REQUIRED.
4 TERMINAL BLOCK TO REMOTE PHOTO- ELECTRIC CELL.
o PHOTO -CELL BY -PASS SWITCH, SPST, 15 AMP, 277 VAC
GROUND FAULT RECEPTACLE, 120 VAC, DUPLEX, 20 AMP
CABINET
NEMA 3R, PADMOUNT, NO. 12 CA'PREGALVANIZED STEEL CONTRUCTION,
2 SCREENED AND GASKETED VENTS.
DOORSI: HEAVY DUTY CONCEALED HINGES (LIFT -OFF TYPE).
PADLOCKABLE STAINLESS STEEL VAULT HANDLE & 3 -POINT LATCH:
POLISHED WIRE GLASS WINDOW IN METER DOOR.
CLOSED CELL NEOPRENE GASKET, CARD HOLDER.
FINISH: POLYESTER POWDER' -COAT, ALUMINUM OUSIDE, WHITE INSIDE.
120/240 VAV, 1 0, 3 WIRE
(REMOTE)
- -- METER PHOTO
BASE ELECTRIC
CELL
'LJ '
i
I_- _- ____ - -I
so"
24"
CITY OF RENTON
i li' -��
I _ N
r _"
❑
'
MAIN m 3
CONTROL
SIGNAL �
LTG.
O
O
0
LST DATE:
DWG. NAME:
I
i
o �
a
I
I
I
'r r -.
TT1
' -T T' -T T''
r - - -I r-�--I
36"
I
I
—
-
WIRING SCHEMATIC
Ills Illl
I_T T I �_T T I
!
i Rl
I
1
�21
I 1
2"�
�2"
FRONT
12"
SIDE
�6
SERVICE'NIREWAY
I
8"
2"
DEADFRONT
BAS E'
77Eo - u / -1z�y
LIGHTING STANDARD & JUNCTION BOX
7' I
0 v o ov ° °ov D
DO
d'-0
d v p p v
4 e ° v O d O e o o v 6 Dv OvD
o O ^O a p ° 4 ? D.
Do 0 p = e0 N
O O 4 0
D e e o J
0
e Qo De a o e D° 6D A
0 Dv o Dv D DD
STREET LIGHT POLE \-JUNCTION BOX
PLAN VIEW
INDIVIDUAL JUNCTION BOX
pv Bo O °DOov 0
e p v
o D p D
e e w4
D Z
H D
AID Dno
4 0 0
4
NOTE: e ° D D c
CLASS "B" CONCRETE TO BE USED 0D. 'a Ov v v D
IN CONSTRUCTION OF PAD,
PLAN VIEW 1
DATE 11 REVISION
TEST
SWITCH
G
li
4 -1/2 "X16 "GALVANIZED
ANCHOR BOLTS (TYP)
CONDUIT ENTR. AREA
- DIAMETER = 7/8"
f 4 -7/8"
LOAD LINE
1/4„ FUS 1/4„
1/8" O 0 1 i8
CUTTING RINGS
FUSE KIT
SIDE VIEW
oY o
ADOPTED
CITY OF RENTON
%19�
STANDARD PLANS
0
LST DATE:
DWG. NAME:
EPDXY FILL
INLINE SPLICE
EPDXY FILL
WYE SPLICE
SPLICE KIT
ADOPTED
CITY OF RENTON
STANDARD PLANS
Nt0 LST DATE:
DWG. NAME: SP PAGE:
4" DEEP
SP PAGE:
RECOMMENDED
FOR APPROVAL
BY DA
DATEW
BY DATE 1
BY DATE
— G.L. BY DATE
�` / 5 ZS BY DATE
N u O a .4191 WAS
x CITY OF RENTON
c. I �1 BEPAR_FMENT,OF PUBLIC WORKS
PLAN VIEW eo,3
Illumination Details (2'of 2)
SIZE TO FIT SIZE TO FIT Roodwcy Illumination
CABINET CABINET r IRM APRa2 +.zom Plat of LaColino
FRONT VIEW SIDE VIEW DATE September 1999 FILE NO
'.DESIDNED D. HAMLIN
'.DMWN D. HAMLIN _
CABINET FOUNDATION
'cMECXED SCALE NONE ; END 1300 _ PAOE—
. N0. REVISION 9Y APFR. DATE APPROVED SHEET 10 OF 10
SCANNED MAR a 0 2000
b da
[n H
N
I�
y
N