HomeMy WebLinkAboutzT-2241SetIDOADWAY ILLUMtNATtON PLAT OF T.. COLINA RENl O WASHtNGTn)N SCHEDULE OF nRp\n/INGS SHEET NO. TITLE 1 COVER SHEET 2 ILLUMINATION PLAN (1 OF 4) 3 ILLUMINATION PLAN (2 OF 4) 4 ILLUMINATION PLAN 3 OF 4 • ro zz r7 Or by N ai ( ) VICINITY MAP 5 ILLUMINATION PLAN (4 OF 4) RECOMMENDED FOR APPROVAL 70. BY DATE p�������S LATE �i 6 NOTES -si-q BY DATE 7 WIRING DIAGRAM, CABINET A Il 9 94Ix19 BY DATE - BY DATE 1J WIRING-DIAGRAM, CABINET B D AS `Z` O I TY OF R E N T O N C)EPARTMENT OF PUBLIC WORKS 9 ILLUMINATION, DETAILS (1 OF: 2) ,aD,D coyer Sheet 1 0 ' ILLUMINATION D ETA I L S (2 O F 2) XR: APRIL 24.2, Roadway Illumination Plot of LaC . DESICrvE N SepC2mber 199 9 DRANK D. HAMLIN DAB Fl LE NO !,TiQe — oc✓ " 22+lL � CHECKED scE' NO_ NFE6 sooK_ PnDE_ . NO. REVISION ''�. BY APPR. DA"fE APPROVED 9HEFr OF D,.. • ro zz r7 Or by N ai D r 3 r r r r GENERAL NOTES EE SHEET 6 FOR LUMINAIRE SCHEDULE, CONSTRUCTION NOTES, AND WIRE NOTES. EE SHEETS 7 AND 8 FOR WIRING DIAGRAMS. EE DETAIL SHEETS FOR MISCELLANEOUS DETAILS. _L FINAL POLE LOCATIONS SHALL BE APPROVED BY THE OWNERS'. REPRESENTATIVE PRIOR CONSTRUCTION. 0' 30' 60' CABINET NO.\ /CIRCUIT NO. \ / LUMINAIRE NO. yA1�G -1 Z AL `2 AM AV 704LZ?441ww LEGEND ® SERVICE VAULT (PSE) I� LIGHTING CONTACTOR CABINET LUMINAIRE POLE / i ®\ TYPE 1 JUNCTION BOX CONDUIT 0 CONSTRUCTION NOTE A WIRE NOTE PSE TRENCH CITY OF RENTON DEPARTMENT OF PUBLIC WORKS AL Illumination Plan (1 of 4) : . Rnnrl .. n.i Illmin n +'.nn I PROVED. SHEEitlV'Z OF 'I p.O. NO. REV 310N 6Y APPR. OATS AP z z a /vz SCANNEO MAR 3 0 2000 i7 .. i»r Sn ^1 a B y N N 4 >v u T ACC 3 MOUNT OLIVET PLAT OF CEMETERY MONTEREY TERRACE GENERAL NOTES 1. SEE SHEET 6 FOR LUMINAIRE SCHEDULE, CONSTRUCTION NOTES, AND WIRE NOTES. 2. SEE SHEETS 7 AND 8 FOR WIRING DIAGRAMS. IETAILS. ;OVED BY THE OWNERS' REPRESENTATIVE PRIOR CABINET N0. X `CIRCUIT N0. / LUMINAIRE NO. A1{` -1 z In M M rn r1? T-1 LEGEND'' \ Il \ - SERVICE VAULT (PSE) ® LIGHTING CONTACTOR CABINET TRACT G 88 89 /! LUMINAIRE POLE TYPE 1 JUNCTION BOX 4 LANDSCAPE/ OPEN SPACE 87 CABINET B - -- CONDUIT O CONSTRUCTION NOTE ,ao,a �wv� A WIRE NOTE - — PSE TRENCH z In M M rn r1? T-1 y �d b o � d a �..� �y y ti 12 \ \ Il \ - RECOMMENDED FOR APPROVAL 43 \ ` .. \ TRACT G 88 89 /! BYQ DATE BY DATE BY DATE BY DATE BY DATE 2 s, / 4 LANDSCAPE/ OPEN SPACE 87 CABINET B g�9°s easg�Q:lr CITY OF RENTON VI. s .DEPARTMENT OF PUBLIC WORKS BZ 1 13 1 ,ao,a �wv� Illumination Plan (2 of 4) 4 E( Roadway Illumination EtiSN� IXPIRESf APeluza,zom Plat of LaColino 44 S . DESIoNm D HAMLIN n. HAMLIN. DAh September 1999 FILE NO CHECKED SCALE NONE F,ELD BOOK_ PAGE_ NO. REVISION BY APPR. DATE APPROVED SHM 3 OF-8— _ - -- = - - - -- - G7; 7-- .?2W03 SCANNED', MAR 302000 MI��Gutr E1 €€' ku6a.;l �y y �d b o � d a �..� �y y ti - RUCTION NOTES, AND WIRE NOTES. LS. D BY THE OWNERS' REPRESENTATIVE PRIOR v� u i =T NO. \ /CIRCUIT NO / LUMINAIRE NO. yA1{` -1 LEGEND 99 BY D q19 yt. as 'ate 0. 30 60 qF yam CITY OF RENTON .DEPARTMENT 0 F PUBLIC WC Illumination Plan (3 of 4) Roadway Illumination ePlrsrs: A IL24.201 1 Plot of'LaColina DESIGNED D. HAMLIN se tember 1999 .... DATE P FlLE NOS cNEcr D. HAMLIN scALE. NONE cIFI.o a�DI TRo —f� i — zzrf'i NO. REVISION 9Y APPR: DATE 0. PROVED SHEE? 4 - wioY SCANNED MHIt 3- 9 'CUUO d> z° z a b lw � lv ti 1� SERVICE VAULT (PSE) LIGHTING CONTACTOR CABINET LUMINAIRE POLE ® TYPE 1 JUNCTION BOX - - - -- CONDUIT O CONSTRUCTION NOTE A WIRE NOTE — — PSE TRENCH RECOMMENDED r44244104 FOR APPROVAL BY DATE BY. ._DATE BY — DATE BY DATE 99 BY D q19 yt. as 'ate 0. 30 60 qF yam CITY OF RENTON .DEPARTMENT 0 F PUBLIC WC Illumination Plan (3 of 4) Roadway Illumination ePlrsrs: A IL24.201 1 Plot of'LaColina DESIGNED D. HAMLIN se tember 1999 .... DATE P FlLE NOS cNEcr D. HAMLIN scALE. NONE cIFI.o a�DI TRo —f� i — zzrf'i NO. REVISION 9Y APPR: DATE 0. PROVED SHEE? 4 - wioY SCANNED MHIt 3- 9 'CUUO d> z° z a b lw � lv ti 1� CrJ T- "Cc/ 0S grLimbtcn MAR 3'A MR y �d �r a �y .. N y LUMINAIRE SCHEDULE CITY OF RENTON LUMINAIRE I.D. NUMBER (1) CABINET I.D. CIRCUIT N0. LUMINAIRE NO. LAMP WATTAGE POLE LOCATIO z OF POLE TO CURBFACE MOUNTING HEIGHT ARM LENGTH REMARKS EDMONDS AVE. N.E.1 DAYTON AVE. N.E. ICAMAS AVE. N.E. BLAINE DR. S.E. S.E. 2ND PL. S.E. 2ND CT. S.E. 3RD ST. 4411 B A 1 1 100 WATT 19 +90 LT — A3 2 NO. 8 (ILLUM) 2" PVC 15 2P — 7 FT. 25 FT_ 8 FT. TYPE III LIGHT DISTRIBUTION 4413B A 1 2 100 WATT 1 -1/2" PVC 3 NO. 14 (PEC) 10 +37 LT 7 FT. 25 FT_ 8 FT. TYPE III LIGHT DISTRIBUTION 44158 A 1 3 100 WATT A6 2 NO. 10 (ILLUM) 1 GREEN NO. 8 (GND) 9 +27 LT TYPICAL ALL NON —PEC— EQUIPPED LUMINAIRES. (34 PLACES). 7 FT. 25 FT. 8 FT. TYPE III LIGHT DISTRIBUTION 44178 A 1 4 100 WATT 6 NO. 8 (ILLUM) 3 NO. 14 (PEC) 2" PVC 7 +62 LT 1 GREEN NO. 8 (GND) 7 FT. 25 FT. 8 FT_ TYPE 111 LIGHT DISTRIBUTION 4428B A 1 5 100 WATT 6+ 30 LT 7 FT. 25 FT. 8 FT_ TYPE III LIGHT DISTRIBUTION 4430B A 1 6 100 WATT 4 +56 LT 7 FT. 25 FT. 8 FT. TYPE III LIGHT DISTRIBUTION 44198 A 1 7 100 WATT 13 +36 LT 7 FT. 25 FT. 8 FT. TYPE III LIGHT DISTRIBUTION 4422B A 1 8 100 WATT 14 +97 RT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 4420B A 1 9 100 WATT 16+60 RT 7 FT. 25 FT. 8 FT. TYPE III LIGHT DISTRIBUTION 4424B A 1 10 100 WATT 3 +63 LT 7 FT. 25 FT_ 8 FT. TYPE III LIGHT DISTRIBUTION 4426B A 1 11 100 WATT 2 +02 LT 7 FT. 25 FT. 8 FT. TYPE III LIGHT DISTRIBUTION 4418B A 1 12 100 WATT 18 +03 RT 7 FT. 25 FT. 8 FT_ TYPE III LIGHT DISTRIBUTION 4410B A 2. 1 100 WATT 12 +38 RT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 44126 A 2 2 100 WATT 13 +72 RT 7 FT. 25 FT. E FT. TYPE III UGHT DISTRIBUTION 441 46 A 2 3 100 WATT 14 +89 RT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 441 6B A 2 4 100 WATT 16+11 RT 7 FT. 25 FT. 8 FT. TYPE III LIGHT DISTRIBUTION 4462B A 2 5 100 WATT 21-4-13 RT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 4464B A 2 6 100 WATT 22 +69 RT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 4466B A 1 2 7 100 WATT 24 +65 RT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 44688 A 2 8 100 WATT 25 +88 RT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 4421B B 1 1 1 00'WATT 11+15 LT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 4436B B 1 2 100 WATT 1 +42 LT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 4438B B 1 3 100 WATT 2 +94 LT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 4440B B 1 4 100 WATT 4 +88 LT 7 FT. 25 FT. ! 8 FT. TYPE III LIGHT DISTRIBUTION 4442B B 1 5 1 00 WATT 5 +98 LT 7 FT. 25 FT. 8 FT. TYPE' IH UGHT DISTRIBUTION 4444B B 1 6 100 WATT 7 +97 LT 7 FT. 25 FT. 8 FT. TYPE III LIGHT DISTRIBUTION 4446B B 1 7 100 WATT 9 +38 RT 7 FT. 25 FT. 8 FT_ TYPE III LIGHT DISTRIBUTION 4448B B 1 8 100 WATT 11 +1 0 RT 7 FT. 25 FT. 8 FT. TYPE III LIGHT DISTRIBUTION 4450B B 2 1 100 WATT 12 +70 RT 7 FT. 25 FT. 8'FT. TYPE III UGHT DISTRIBUTION 4452B B 2 2 100 WATT 14 +00 RT 7FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 4454B B 2 3 100 WATT 15+46 RT 7 FT. 25 FT. 8 FT. TYPE III UGHT DISTRIBUTION 4456B B 2 4 100 WATT 16+71 RT 1 7 FT. 25 FT. 8 FT. TYPE III LIGHT DISTRIBUTION 4458B B 2 5 100 WATT 18+11 RT 7 FT. 25 FT. 8 FT_ TYPE III UGHT DISTRIBUTION 4460B B 2 6 100 WATT 19 +66 RT 7 FT. 25 FT. 8 FT- TYPE III UGHT DISTRIBUTION 4434B B 2 7 100 WATT 1+43 LT 7 FT. 25 FT. 8 FT_ TYPE III LIGHT DISTRIBUTION 4432B B 2 8 10 WATT 1 2 +87 LT 7 FT. 25 FT. 8 FT_ TYPE III LIGHT DISTRIBUTION I (1) NUMBER TO BE AFFIXED TO POLE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAIL (SEE SHEET 9). CONSTRUCTION NOTES 1O CONSTRUCT SERVICE /ILLUMINATION CABINET FOUNDATION. INSTALL SERVICE /ILLUMINATION CABINET WITH METER BASE (SEE SHEET 10). O2 CONSTRUCT LUMINAIRE POLE FOUNDATION (SEE LUMINAIRE POLE SCHEDULE FOR LOCATION, SEE SHEET 10 FOR FOUNDATION DETAIL). INSTALL LUMINAIRE POLE AND LUMINAIRE. INSTALL TYPE 1 JUNCTION BOX AND CONCRETE PAD (SEE SHEETS 9 & 10). TYPICAL 34 PLACES, O CONSTRUCT LUMINAIRE POLE FOUNDATION (SEE LUMINAIRE POLE SCHEDULE FOR LOCATION, SEE SHEET 10 FOR FOUNDATION DETAIL). INSTALL LUMINAIRE POLE AND LUMINAIRE WITH INTEGRAL PHOTO— ELECTRIC CELL. INSTALL TYPE 1 JUNCTION BOX AND CONCRETE PAD (SEE SHEETS 9 & 10). O4 INSTALL TYPE 1 JUNCTION BOX (SEE WSDOT STD. PLAN J -11 a & SHEET 10). 05 CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH PUGET SOUND ENERGY REQUIREMENTS. TRo - ft / -2z�rj I WIRE NOTES RUN CONDUCTORS CONDUIT COMMENTS REMARKS 3 NO. 2 (POWER) 2" PVC — — 1 GREEN NO. 8 (GND) 1 ILLUM — A2 4 NO. 8 (ILLUM) 2" PVC 2 ILLUM — 1 GREEN NO. 8 (GND) 30 240 VOLT 3 SIGN LTG 3 NO. 14 (PEC) 20 1 P — A3 2 NO. 8 (ILLUM) 2" PVC 15 2P — 1' GREEN NO. 8 (GND) 3 NO. 14 (PEC) A4 2 NO. 10 (ILLUM) 1 -1/2" PVC 3 NO. 14 (PEC) 1 GREEN NO. 8 (GND) 2 NO. 8 (ILLUM) 2" PVC 1 GREEN NO. 8 (GND) A6 2 NO. 10 (ILLUM) 1 GREEN NO. 8 (GND) 1 -1/2" PVC TYPICAL ALL NON —PEC— EQUIPPED LUMINAIRES. (34 PLACES). Z7 4 NO. 8 (ILLUM) 2" PVC 1 GREEN NO. 8 (GND) A8 6 NO. 8 (ILLUM) 3 NO. 14 (PEC) 2" PVC 1 GREEN NO. 8 (GND) NOTE: LATERAL CONDUITS SHALL BE PVC SCH: 40. STREET CROSSINGS ARE EXISTING. CONTRACTOR SHALL CONFIRM LOCATIONS OF ALL EXISTING CONDUITS PRIOR TO CONSTRUCTION. NEW STREET CROSSINGS SHALL BE PVC SCH 80. SERVICE CABINET A (I.D. NO. 0030) BREAKER AND CONTACTOR SCHEDULE CIRCUIT NO. MAIN BREAKER AMPS BRANCH BREAKER AMPS CONTACTOR AMPS REMARKS MAIN 100 — — 120/240 VOLT 1 ILLUM — 20 2P 30 240 VOLT 2 ILLUM — 20 2P 30 240 VOLT 3 SIGN LTG — 20 1 P — 120 VOLT 4 IRRIG — 15 2P — 120V SERVICE CABINET B (I.D. NO. 0031 ) BREAKER AND CONTACTOR SCHEDULE CIRCUIT NO. MAIN BREAKER BRANCH BREAKER AMPS AMPS CONTACTOR AMPS REMARKS MAIN 100 — — 120/240 VOLT 1 ILLUM — 20 2P 30 240 VOLT 2 ILLUM — 20 2P 30 240 VOLT 3 IRRIG — 15 1 P — 120V c u; i J2ui0e SCANNED MAR 3 0 2040'. r .�I 0a � H �I I ti Al -4 Al -3 t (t Al -2 2N0' 8 2 NO. 8 2 N0. 8 Al -5 TYPE 1JB TYPE IJB 't TYPE 1JB,F TYPE 1JBI Al -1 2 NO. 10 TYPICAL ALL LUMINAIRES �TO SERVICE POINT TYPEIJB � PEC N 2NO.8' z -- TYPE 1JB SERVICE /ILLUMINATION CABINET A — — — ' METER 2 NO. 8 BASE 2 NO. 8 ILLUM CKT 1 TYPE_1JB A7 -12 Al -6 2 NO. 8 ILLUM CKT 2 � ' 3 NO. 14 PHOTO -CELL i Al -8 Al -9 TYPE 1 JB - - -f ' - -, TYPE 1,113 2 N0. 8 -, 2 N0. 8 TYPE 1 JB t A2 -1 ( TYPE 1JB TYPE 1JB; ' 2 N0. 8 2 N0. 8 ' - -' TYPE 1JB - TYPE 1JB TYPE 1JB- - 00 0 Ai -7 Z N Al -10 TYPE 1JB; ' J A2 -2' TYPE 1JB; co co o ° z z , Al -11 A2 -3 TYPE 1JB; TYPE 1JB; ; 0 z A2 -5 N A2-4 TYPE1JB t TYPE 1JB T'PE�1JB 00 00 6 0 74424107 N i t N � _1 TYPE JJB 00 0 z N A2 -7 / TYPE 1 JB, qA�9 st�esg�'et� F� N �� CITY OF- F E)EPARTMENT CI m �s Wiring Diagran 0 z Roadway IIIu N A2 8 fl( IM: APRO.24.200, Plat of La OMINED D. HAMLIN DATE Septemt TYPE 1 JBi i D. HAMLIN TWO- 4 / -12fi/ cNRL10E0 �_.-'Q -- ScAie NONE . NO. REVISION HY APPR. DATE APPROVED SCANNEq MFR 3 0 2000 H i7r 0 N N '1 a ti If B1 -5 B1 -4 2 NO. 8 TYPE 1 JB 131-6 - 2 NO. 8 TYPE 1 JB TYPE 1 JB TYPE 1 JB 131 -3 TYPE1JB B1 -7 00 c z N O N i TYPE 1 JB B1 -8 TYPE 1 JB B1 =2 TYPE T JB - �a 2 NO. 8— 2 NO. 8 _!TYPE 1 JB B1 -1' TYPE 1 JB TYPE 1 JB -- ; 3 NO 2 TO SERVICE POINT PEC L_ _ __' SERVICE /ILLUMINATION CABINET B 2 NO. 8 METER BASE ! 132 -1 2 N0. 8 ILLUM CKT 1 2 NO. 8 ILLUM CKT 2 132 -8 3 NO. 14--1 PHOTO =CELL TYPE 1 JB; ; L aD 2 NO. 10 TYPICAL ALL LUMINAIRES Z: N B2 -7 TYPE 1 JB; ; J 2 NO. 8 TYPE 1 JB! B2 -2 - TYPE 1 JB B2 -3 132 -4 0 B2 -5 132 -6 z N 2 N0. 8 ' 2 N0. 8 2 N0. 8 ' 2 NO. 8"- 7.4241,0,0 TYPE 1 JB TYPE 1 ,JB TYPE'1 JB TYPE '1 JB b e> 0 n m -Di ti N SERVICE CABINET FOR ILLUMINATION AND TRAFFIC SIGNAL SKYLINE ELECTRIC & MFG. CO. MODEL NO. 47700 -R COMPONENT SCHEDULE OMETER'BASE: 100 AMP, 4 JAW, A. W. NO. 1 21 314 WITH BYPASS BLOCKS. (CONTRACTOR TO VERIFY WITH SERVING UTILITY). OPANELBOARD: 120/240 VAC, 100 AMP, 1 PHASE, 3 WIRE, COPPER BUS. WESTINGHOUSE BAB BOLT -ON BREAKERS: 1 - 100/2 MAIN 1 - 20/2 ILLUMINATION BRANCH BREAKER 1 - 15/1 CONTROL CIRCUIT BRANCH BREAKER O3 CONTACTOR: LIGHTING RATED, 2 POLE, 120 VAC COIL, TE /GOULD NO. 2200EBy320AA 1 REQUIRED. 4 TERMINAL BLOCK TO REMOTE PHOTO- ELECTRIC CELL. o PHOTO -CELL BY -PASS SWITCH, SPST, 15 AMP, 277 VAC GROUND FAULT RECEPTACLE, 120 VAC, DUPLEX, 20 AMP CABINET NEMA 3R, PADMOUNT, NO. 12 CA'PREGALVANIZED STEEL CONTRUCTION, 2 SCREENED AND GASKETED VENTS. DOORSI: HEAVY DUTY CONCEALED HINGES (LIFT -OFF TYPE). PADLOCKABLE STAINLESS STEEL VAULT HANDLE & 3 -POINT LATCH: POLISHED WIRE GLASS WINDOW IN METER DOOR. CLOSED CELL NEOPRENE GASKET, CARD HOLDER. FINISH: POLYESTER POWDER' -COAT, ALUMINUM OUSIDE, WHITE INSIDE. 120/240 VAV, 1 0, 3 WIRE (REMOTE) - -- METER PHOTO BASE ELECTRIC CELL 'LJ ' i I_- _- ____ - -I so" 24" CITY OF RENTON i li' -�� I _ N r _" ❑ ' MAIN m 3 CONTROL SIGNAL � LTG. O O 0 LST DATE: DWG. NAME: I i o � a I I I 'r r -. TT1 ' -T T' -T T'' r - - -I r-�--I 36" I I — - WIRING SCHEMATIC Ills Illl I_T T I �_T T I ! i Rl I 1 �21 I 1 2"� �2" FRONT 12" SIDE �6 SERVICE'NIREWAY I 8" 2" DEADFRONT BAS E' 77Eo - u / -1z�y LIGHTING STANDARD & JUNCTION BOX 7' I 0 v o ov ° °ov D DO d'-0 d v p p v 4 e ° v O d O e o o v 6 Dv OvD o O ^O a p ° 4 ? D. Do 0 p = e0 N O O 4 0 D e e o J 0 e Qo De a o e D° 6D A 0 Dv o Dv D DD STREET LIGHT POLE \-JUNCTION BOX PLAN VIEW INDIVIDUAL JUNCTION BOX pv Bo O °DOov 0 e p v o D p D e e w4 D Z H D AID Dno 4 0 0 4 NOTE: e ° D D c CLASS "B" CONCRETE TO BE USED 0D. 'a Ov v v D IN CONSTRUCTION OF PAD, PLAN VIEW 1 DATE 11 REVISION TEST SWITCH G li 4 -1/2 "X16 "GALVANIZED ANCHOR BOLTS (TYP) CONDUIT ENTR. AREA - DIAMETER = 7/8" f 4 -7/8" LOAD LINE 1/4„ FUS 1/4„ 1/8" O 0 1 i8 CUTTING RINGS FUSE KIT SIDE VIEW oY o ADOPTED CITY OF RENTON %19� STANDARD PLANS 0 LST DATE: DWG. NAME: EPDXY FILL INLINE SPLICE EPDXY FILL WYE SPLICE SPLICE KIT ADOPTED CITY OF RENTON STANDARD PLANS Nt0 LST DATE: DWG. NAME: SP PAGE: 4" DEEP SP PAGE: RECOMMENDED FOR APPROVAL BY DA DATEW BY DATE 1 BY DATE — G.L. BY DATE �` / 5 ZS BY DATE N u O a .4191 WAS x CITY OF RENTON c. I �1 BEPAR_FMENT,OF PUBLIC WORKS PLAN VIEW eo,3 Illumination Details (2'of 2) SIZE TO FIT SIZE TO FIT Roodwcy Illumination CABINET CABINET r IRM APRa2 +.zom Plat of LaColino FRONT VIEW SIDE VIEW DATE September 1999 FILE NO '.DESIDNED D. HAMLIN '.DMWN D. HAMLIN _ CABINET FOUNDATION 'cMECXED SCALE NONE ; END 1300 _ PAOE— . N0. REVISION 9Y APFR. DATE APPROVED SHEET 10 OF 10 SCANNED MAR a 0 2000 b da [n H N I� y N