HomeMy WebLinkAboutzD-2330SetC)
M
N
I
N
CL
s
X
X
X
I
n
N
1
IL
3
w
z
Li
L,
N
2 "S
O
NE 4TH ST /�mOfrOE AVE NE
EX CB TYPE 2; -7,2"
STA. 2 +76
RIM EL= RIM 39.93
/- N,S 36 "IE= 332.76
3 00
TOO -EL 340.12
Tel
EX CB TYPE 1
RIM EL= 339.48
E,W 8 "IE =336.2
z
0
Q
w
v
z
w
Ll-
'EE
Tel
36"S
FENCE ALONG PL
— N MEW
Tel Tel
FE
SHRUBS, BLACKBE
L 23' NORTH OF EXOCATE CB -1 16 "W
. CB�
i 12's Ste -
6+00
POSSIBLE BURIED TINES CONIC
CE:t- --T _ LOCATE -`I
STREET LIG QWEST, n, I
x
WATERFILLED DITCH - REMOVE TREES, IF NEEDED -
ALONG TOE OF SLOPE FOR PIPE ALIGNMENT
LOCATION, SIZE, APPX ROCK APRON
SEE DETAIL
EX CB TYPE 1
RIM EL =345.7
E 8 "I E = -__
Tel O
I o
1 00
-1
I o
I ^c�
R
I
u
EX CB TYPE 2, 72"
STA. 6 +49
RIM EL= 345.76
N,S 36 "IE= 332.35
W 18" IE= 339.13
X=36' SD
12 "S S_
1(D
IN k
m
'-' Te I
1 6 "W -
� D
7 +00
WATER
FILLED D�-�- -
T�N APPX _
CHECKED FOR COMPLIANCE RECOMMENDED
TO CITY STANDARDS FOR APPROVAL
Richard W. Marshall Date 8/10/07 BY Daniel Carey 8/10/07
Ronald J. Straka Date 6/10/ 7 BY
Date
CALL 48 HOURS BEFORE YOU DIG
811 OR (old #1- 800 -424 -5555)
EXISTING UTILITY LOCATIONS ARE APPROXIMATE, NOT ALL UTILTIES MAY BE SHOWN.
CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES.
GENERAL NOTES:
A. THIS PLAN DEVELOPED FROM PLANS AND ELEVATIONS IN CITY FILES.
NOT SURVEYED. LOCATIONS MAY VARY.
REF: R -1516 MONROE AVE NE, NE 4TH ST TO NE 2ND ST.
ELEVATION CONVERTED TO NAVD 1988 FROM NGVD 1929.
DRAWING NOTES:
1O CONTRACTOR SHALL INSTALL EROSION CONTROL, INCLUDING
FILTER FABRIC PROTECTION FOR DOWNSTREAM CATCHBASINS.
2O TRENCH PATCH SHALL BE PER CITY DETAIL HR -23 TYPICAL
PATCH FOR FLEXIBLE PAVEMENT PERPENDICULAR TO ROAD CL.
E RESTORE CURB, GUTTER, SIDEWALK PER CITY DETAIL DRAWINGS.
ADJUST AS NEEDED TO MATCH EXISTING.
® RESTORE DISTURBED AREA, FERTILIZING, SEEDING, MULCHING
ORIGNAL PLANS STAMPED BY: RJS, DWC . '____.-
RONALD J. STRAKA ON :8/10/07 IF NOT ONE INCH
S
PE #29727 EXPIRES: 10/16/07 NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY
RJS
AS-BUILT SURVEY BY:
TOUMA ENGINEERS
AS -BUILT PLANS STAMPED BY:
MOUNIR H. TOUMA ON:11 /27/07
PE #9470 EXPIRES: 6/22/09
t
MONROE AVE NE STORM SYSTEM
OVERFLOW PROJECT
8/9/2007
FlELDBOOK:
PAGE:
DRAWING NO:
1
SHEET* OF:
x 2
POSSIBLE BURIED LINES
POTHOLE 8 "SS
CALL TO LOCATE REMOVE FENCE AS NEEDED
FOR CONSTRUCTION.
BEFORE CONSTR.
STREET LIGHTS, QWEST REPLACE AT COMPLETION
350...
350 - .....................
.. ...............................
... POTHOLE: LOCATION ..... ...... ...........
BEFORE CONSTR.(1)
................... ....... ............ ...................
...................
_
................... : ................... : ................... : ................... ................... .. ................. : ................... . ...................
SCALE: : IZ: 1 "= 10' PROFILE ALONG NEW PIPELINE
.......... - ...... ---
VERT: 1 "_ 10°
16 "W
..:.:
FLANGE JOINT, ELBOW:
340 —
........................._
..::_::_,�.,........:.
:...................:......... �.. �.............. _ ... .........................:.....
E 5 4-..lE ..335.1.0.:...................:
. :.
.............
:
SEE DETAIL
NO MACHINERY ALLOWED ON SLOPE:
DOWNSTREAM CB
AT
McDONALDS RIM:
EL 339:-48
_ :-
p
EL 339.93
...... ..................:
.....
..............
-330 ..:
330 -
.......................................:..................:.................:
..................:............ ........... ..................:.....
12 "SS DEADMAN :ANCHOR
...': -..: ............................................:..........
.............................�'
103± LF 24 HDPE
IE -334.4 25 FT FROM CL CB
LAY PIPE ON TOP OF SLOPE
TOP 335.5± EST SEE DETAIL
(FROM FLANGE TO END,
CB -1 TYPE 1, 72"
: CONFIRM LENGTH NEEDED IN FIELD)
32O — :.souo..
STA 6 +26, 7.6'L
COVER ..................:...........
.......:...................:...
0 031
45t LF 24 ': HDPE -8-88 FT/ FT ....:.......
............:.................:
:. :' -:._..
::. :.....................................:.......................................:......................................
TREES, DEBRIS
...............................
— .320 :
:
RIM EL -346 --
RIM 346.40
: (CB WALL TO FLANGE, INCLUDING FITTINGS,
: HAND REMOVE BRUSH, SMALL :
N,S 36 "IE 332.3
CONFIRM LENGTH NEEDED IN FIELD ) .
ON SLOPE AS NEEDED TO INSTALL NEW PIPE.
W 24" IE 33&:,4-
W24" 336.50
PROVIDE MIN. 6" CLEARANCE
BETWEEN EX. 12 "SS AND NEW
10 -
............. :.............
STORM ..PIPE.. ..................:.. ................:............ .......:..................._ - --
..................._........ ...... ........... _.........................................._.........................—
310
CONTRACTOR TO CONFIRM EX. :PLACE
ETHAFOAM PADDING
STORM PIPE TYPE
AND ELEVATION.
BETWEEN PIES (6 INCHES +)
PIPE: ANCHOR
SADDLE EX.-STORM
PIPE WITH NEW
-12 FT FROM END
CB AND REMOVED
STORM PIPE
SEE :DETAIL
IN NEW CB.
— 300
3OO -
.......................................................
..............................
.. ...............................
END...... pi......
OF PE
STAG -+26, 136' R
APPX
EL '28&* 284.86
29O —
...................... ...............................
...................
.................:....... ............:..................
:.......
.................. :: ;:...........
: ROCK APRON
9
SEE DETAIL
® o
gLALALA
EX GROUND :APPX
CHECKED FOR COMPLIANCE RECOMMENDED
TO CITY STANDARDS FOR APPROVAL
Richard W. Marshall Date 8/10/07 BY Daniel Carey 8/10/07
Ronald J. Straka Date 6/10/ 7 BY
Date
CALL 48 HOURS BEFORE YOU DIG
811 OR (old #1- 800 -424 -5555)
EXISTING UTILITY LOCATIONS ARE APPROXIMATE, NOT ALL UTILTIES MAY BE SHOWN.
CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES.
GENERAL NOTES:
A. THIS PLAN DEVELOPED FROM PLANS AND ELEVATIONS IN CITY FILES.
NOT SURVEYED. LOCATIONS MAY VARY.
REF: R -1516 MONROE AVE NE, NE 4TH ST TO NE 2ND ST.
ELEVATION CONVERTED TO NAVD 1988 FROM NGVD 1929.
DRAWING NOTES:
1O CONTRACTOR SHALL INSTALL EROSION CONTROL, INCLUDING
FILTER FABRIC PROTECTION FOR DOWNSTREAM CATCHBASINS.
2O TRENCH PATCH SHALL BE PER CITY DETAIL HR -23 TYPICAL
PATCH FOR FLEXIBLE PAVEMENT PERPENDICULAR TO ROAD CL.
E RESTORE CURB, GUTTER, SIDEWALK PER CITY DETAIL DRAWINGS.
ADJUST AS NEEDED TO MATCH EXISTING.
® RESTORE DISTURBED AREA, FERTILIZING, SEEDING, MULCHING
ORIGNAL PLANS STAMPED BY: RJS, DWC . '____.-
RONALD J. STRAKA ON :8/10/07 IF NOT ONE INCH
S
PE #29727 EXPIRES: 10/16/07 NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY
RJS
AS-BUILT SURVEY BY:
TOUMA ENGINEERS
AS -BUILT PLANS STAMPED BY:
MOUNIR H. TOUMA ON:11 /27/07
PE #9470 EXPIRES: 6/22/09
t
MONROE AVE NE STORM SYSTEM
OVERFLOW PROJECT
8/9/2007
FlELDBOOK:
PAGE:
DRAWING NO:
1
SHEET* OF:
x 2
0
M
C'7
N
I
N
CL
L1J
X
X
X
X
r
N
V)
w
zz
w
J
t%.
FLANGE JOINT, TYPICAL
24" IPS BACK —UP RING (2)
PRESSURE CLASS 160
24" FLANGE ADAPTER-
DR 17, PRESSURE
CLASS 160 (2)
BUTT —FUSED JOINT (TYP)
24 BOLTS, NUTS, WASHERS
1 1/4" X 12.5 "(MIN)
VERIFY LENGTH NEEDED
SPOOL, 2' MIN. 24" ELBOW
(APPX 30% VERIFY WITH
ACTUAL GROUND SLOPE)
BUTT —FUSED JOINT (TYP)
COMPACTED BEDDING
CONTRACTOR TO ADJUST ELBOW LOCATIONS AND
SPOOL LENGTHS AS NEEDED TO FIT SLOPE.
REVIEW WITH CITY BEFORE FABRICATING.
�_I ANIr,F 1r)INIT P-I Rn\A/ nP -TAII
CONCRETE SHALL BE KEYED 12" MIN.
AGAINST UNDISTURBED EARTH BOTH FACES
CLASS 5 1/2 SACK
CONCRETE 3000 PSI MIP
3" CLR
#4 REBAR 8" O.C. EA
CENTER IN CONCRETE
5'
mewrn
1.5' MIN.
NTS
ANVIL FIG. TYPE 212 PIPE CLAMP OR EQUAL
SPLIT AT SPRINGLIKE. CLAMP ID 24"
CLAMP TIGHT TO PIPE
('ONCRETE ANCHOR AROUND PIPE
6' MIN. _)
SECTION VIEW
3" COVER
(TYP)
CONCRETE DEADMAN ANCHOR DETAIL (NTS)
RECOMMENDED
FOR APPROVAL
BY Daniel Carey 8/10/0
BY
ORIGINAL PLANS STAMPED BY.
RONALD J. STRAKA ON:8 /10/07
PE #29727 EXPIRES- 10/16/07
•. wo
COLLAR (2"
WELDED TO
OR 2 BOLTS
THREADED EP
SHAPE END
TO A POINT
's�
ROCK APRON (Nn)
ANVIL FIG. TYPE 212 PIPE CLAMP WITH GALV. FINISH
OR EQUAL. SPLIT AT SPRINGLIKE.
CLAMP ID 26" MIN TO ALLOW PIPE TO SLIDE THRU CLAMP.
FILLET 1 12" TYP
DLT, 7/8" DIA,
\SHERS 2" DIA,
PLATE
ao cu
0i
d-
cu
PLATE DETAIL
1/4" PLATE ASTM A36 STEEL
GALV. AFTER FABRICATION PER ASTM A123.
CONFIRM THAT PLATE WILL MATCH
CLAMP FITTING AND BOLT DIMENSIONS
BEFORE FABRICATION.
1g" X 5' PIN PILE EACH SIDE
ASTM A36 STEEL GALV. AFTER FABRICATION PER ASTM A153,
OR 5' PIN WITH THREADED END (12 ")
PIPE ANCHOR DETAIL
NTS
HMA, 2 "(MIN)
CLASS 1/2"
ROCKS 12 " -18" DIA
TWO TO THREE LAYERS THICK
,
6.5' MIN.
MIN Ml'
IN r MIN 1 Ml'
IN Ml'
IN
*MINIMUM ATB:
PRINCIPAL /MINOR /COLLECTOR ARTERIAL STREETS
AND INDUSTRIAL ACCESS STREETS — 6" ATB CLASS `E' or `B'
RESIDENTIAL ACCESS STREETS — 2" ATB CLASS `E' or `B'
D SURFACING TOP COURSE
'ECS FOR PIPE BEDDING
) BACKFILL REQMTS.
TYPICAL PATCH FOR FLEXIBLE PAVEMENT
PERPENDICULAR TO ROAD CENTERLINE
DWG NAME: HR -23 (NTS)
AS-BUILT SURVEY BY: