Loading...
HomeMy WebLinkAboutzT-2776SetIDOADWAY ILLUMINATtON 1\, PLAT OF TALBOT RIDGE RENTON WASHINGTON Tw277601 TRo -21 2776 ROLL 161 1 18 NE 4TH ST SR`7 6g 01'V \ g � rT I 'Project Q P w SW 43RD ST SE Location 176TH ST w w w w SCHEDULE OF DRAWINGS n J _ w _ F- w tO w _ ~ O d SE 192ND ST > SHEET N0. TITLE -' 0 1 1 COVER SHEET S. 21 TH ST k V SE 208TH S 2 ILLUMINATION PLAN w 3 ILLUMINATION DETAILS (1 OF 3) (- > MI 4 ILLUMINATION DETAILS (2 OF 3) I VICINITY MAP 5 ILLUMINATION DETAILS (3 OF 3) _9 /pia_ TRo -21 2776 ROLL 161 1 18 LUMINAIRE SCHEDU�_E LUMINAIRE N0. CITY OF RENTON LUMINAIRE I.D. NUMBER 1 SEE CITY OF RENTON SPECIAL PROVISIONS POLE LOCATION � OF POLE CURBFACE FOR BOLT SPECIFICATION. LENGTH OF BOLT CIRCUIT N0. -REMARKS MAY BE SHORTENED IF IT MEETS MANUFACTURERS 2567 100 WATT RECOMMENDED LENGTH. � 6 FT. I I � I � I 2 2566 18" MIN. I I I I I 25 FT. 1 TYPE III LIGHT DISTRIBUTION 3 II I 100 WATT 12 +5G' RT S� 6 FT. _ 1 TYPE III LIGHT DISTRIBUTION CLASS 3000 CONCRETE I � 4' -6" ® �+-o - BY I I - - 25 FT. O' 40' 80' EN SPACED I- � i 2560 100 WATT #4 HOOPS I I 25 FT. 1 12" CENTERSI - - - � 2558 100 WRTT 17 +14 RT -� 2 "CLEARANCE 3' SO OR RND FOUNDATION DETAIL LUMINAIRE SCHEDU�_E LUMINAIRE N0. CITY OF RENTON LUMINAIRE I.D. NUMBER 1 LAMP WATTAGE POLE LOCATION � OF POLE CURBFACE MOUNTING HEIGHT CIRCUIT N0. -REMARKS 1 2567 100 WATT 9 +91 RT � 6 FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 2 2566 100 WATT 11 +40 LT �` 6 FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 3 2564 100 WATT 12 +5G' RT S� 6 FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 4 2562 100 WATT 14 +iii RT Do 6 FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 5 2560 100 WATT 15 +59 RT 6 Ff. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 6 2558 100 WRTT 17 +14 RT 6 FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 7 2556 100 WATT 18 +67 RT 6 FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 8 2554 10.0 WATT 20 +� RT � 6 FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION � u (1) NUMBER TO BE AFFIXED TO POLE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAIL. WIRE NOTES RUN CONDUCTORS CONDUIT CONTACTOR AMPS REMARKS MAIN 100 3 N0. 2 (POWER) 1 GREEN N0. 8 (GND) 2" PVC 120 240 VOLT 1 ILEUM 4 N0. 10 ( ILEUM) 1 GREEN N0. 8 (GND) 2" PVC 30 240 VOLT 3 N0. 14 (PEC) a 2 N0. 10 (ILEUM) 1 GREEN N0. 8 (GND} 2" PVC 3 iVO. 14 (PEC) �4 2N0. 10 (ILEUM) 1 GREEN N0. 8 (GND) 2" PVC �5 2N0. 10 (ILEUM) 1 GREEN N0. 8 (GND) 1 -1/2" PVC CONSTRUCTION NOTES 1`� CONSTRUCT SERVICE /ILLUMINATION CABINET FOUNDTION. INSTALL SERVICE /ILLUMINATION CABINET WITH METER BASE (SEE DETAIL SHEET 5). �2 CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX {SEE DETAIL, SHEET 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS LUMINAIRE (GE M -250A2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS). CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX SEE DETAIL, SHEEP 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS LUMINAIRE (GE M -250A2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS AND INTERNAL PEC). Q4 INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD (SEE DETAIL, SHEEP 4). �5 CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH PUGET SOUND ENERGY REQUIREMENTS. T,p6- `i/ -3776 CONSTRUCTION NOTE WIRE NOTE SERVICE CABINET (I.D. N0. 0025 BREAKER AND CONTACTOR SCHEDULE CIRCUIT N0. MAIN BREAKER AMPS BRANCH BREAKER AMPS CONTACTOR AMPS REMARKS MAIN 100 - - 120 240 VOLT 1 ILEUM - 20 30 240 VOLT • • 119 ��-� �0�� 3CH. 40. SCH. 80. •f3_99 .7i'� 7iPa -0/- 2776 SERVICE CABINET FOR ILLUMINATION AND TRAFFIC SIGNAL SKYLINE ELECTRIC & MFG. CO. MODEL NO. 47700 -R COMPONENT SCHEDULE 1O METERBASE: 100 AMP, 4 JAW, A. W. NO. 121314 WITH BYPASS BLOCKS. (CONTRACTOR TO VERIFY WITH SERVING UTILITY). OPANELBOARD: 120/240 VAC, 100 AMP, 1 PHASE, 3 WIRE, COPPER BUS. WESTINGHOUSE BAB BOLT -ON BREAKERS: 1 - 100/2 MAIN 1 - 20/2 ILLUMINATION BRANCH BREAKER 1 - 15/1 CONTROL CIRCUIT BRANCH BREAKER O CONTACTOR: LIGHTING RATED, 2 POLE, 120 VAC COIL, TE /GOULD NO. 2200EB320AA 1 REQUIRED. 4 TERMINAL BLOCK TO REMOTE PHOTO- ELECTRIC CELL. 5 PHOTO -CELL BY -PASS SWITCH, SPST, 15 AMP, 277 VAC 6 GROUND FAULT RECEPTACLE, 120 VAC, DUPLEX, 20 AMP CABINET NEMA 3R, PADMOUNT, NO. 12 GA PREGALVANIZED STEEL CONTRUCTION, 2 SCREENED AND GASKETED VENTS. DOORS: HEAVY DUTY CONCEALED HINGES (LIFT -OFF TYPE). PADLOCKABLE STAINLESS STEEL VAULT HANDLE & 3 -POINT LATCH. POLISHED WIRE GLASS WINDOW IN METER DOOR. CLOSED CELL NEOPRENE GASKET, CARD HOLDER. FINISH: POLYESTER POWDER -COAT, ALUMINUM OUSIDE, WHITE INSIDE. 120/240 VAV, 10, 3 WIRE tBMASE ETER I�, 1 N m 3 24" " t CONTROL ® u _rtiSIGNAL 0 I II I I I n '---- ------' r— ,. LTG 60 I I O I O i O ' i i I 1 (REMOTE) PHOTO ELECTRIC CELL TEST SWITCH G FI 36" ii—Ti ii—Li ' IT T, ,_T 7_, ; WIRING SCHEMATIC rjT TTl i iTT i j T T , T T I _ I I I I I I �21 "� 2" —'1 �-2" FRONT 12 "� SIDE �6 SERVICE WIREWAY I 8" 12" � 2" I DEADFRONT BASE ROLL 161 1 dim 0 4 -1/2 "X16 "GALVANIZED ANCHOR BOLTS (TYP) CONDUIT ENTR. AREA — G.L. 04 O O � PLAN VIEW SIZE TO FIT SIZE TO FIT CABINET CABINET FRONT VIEW SIDE VIEW CABINET FOUNDATION APPR. I DATE APP 0VM _ r `CANNED DEC 101999 1 Q 1= Z 4 .a CONSTRUCTION NOTES 1O CONS FRUCT SERVICE /ILLUMINATION CABINET FOUNDTICN. INSTALL SERVICE /ILLUMINATION CABINET WITH METER BASE (SEE DETAIL SHEET 5). O CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX (SEE DETAIL, SHEET 4 ) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS LUMINAIRE (GE M -250A2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS). 0 CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX SEE DETAIL, SHEET 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS SEE (GE M -25OA2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS AND INTERNAL PEC). O4 INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD (SEE DETAIL, SHEET 4). O5 CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH P'JGET SOUND ENERGY REQUIREMENTS. mO 1° kI — :»i PROPOSED PSE VAULT. CONFIRM EXACT LOCATION AT TIME OF CONSTRUCTION. LUMINAIRE SCHEDULE LUMINAIRE NO. CITY OF RENTON LUMINAIRE I.D. NUMBER (l SEE CITY OF RENTON SPECIAL PROVISIONS C OF POLE MOUNTiNG CURBFACE HEIGHT CIRCUIT NO. REMARKS FOR BOLT SPECIFICATION. LENGTH OF BOLT 2567 1 D0 WATT 9 +91 RT -1 °&FT. 25 FT. MAY BE SHORTENED IF IT MEETS MANUFACTURERS TYPE III LIGHT DISTRIBUTION 2 2566 RECOMMENDED LENGTH. ''IN. 1 TYPE III LIGHT DISTRIBUTION 3 2564 100 WATT 12+ T 5'f fo 25 FT. 18 TYPE III LIGHT DISTRIBUTION 4 2562 100 WATT 114+qgR 25 FT. 1 TYPE III LIGHT DISTRIBUTION 5 2560 100 WATT 15 +59 RT ,.MFT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 6 2558 100 WATT 17 +14 R FT. 25 FT. 1 TYPE II! LIGHT DISTRIBUTION 7 2556 100 WATT 18+DeoRT i 25 FT. 1 TYPE III LIGHT DISTRIBUTION CLASS 3000 CONCRETE -- fi ( 7 - 25 FT. 4' -6" TYPE III LIGHT DISTRIBUTION 8 #7 BARS I O' 40' 80' EVENLY SPACED _ #4HOOPS " I­ - -- J 12 CENTERS _� — — — 2" CLEARANCE 3' SO OR RND FOUNDATION DETAIL Q 1= Z 4 .a CONSTRUCTION NOTES 1O CONS FRUCT SERVICE /ILLUMINATION CABINET FOUNDTICN. INSTALL SERVICE /ILLUMINATION CABINET WITH METER BASE (SEE DETAIL SHEET 5). O CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX (SEE DETAIL, SHEET 4 ) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS LUMINAIRE (GE M -250A2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS). 0 CONSTRUCT LUMINAIRE POLE FOUNDATION WITH CONCRETE PAD AND TYPE 1 JUNCTION BOX SEE DETAIL, SHEET 4) INSTALL 25 FT. LIGHT STANDARD WITH 100 WATT HPS SEE (GE M -25OA2 POWR /DOOR LUMINAIRE WITH CUT -OFF OPTICS AND INTERNAL PEC). O4 INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD (SEE DETAIL, SHEET 4). O5 CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH P'JGET SOUND ENERGY REQUIREMENTS. mO 1° kI — :»i PROPOSED PSE VAULT. CONFIRM EXACT LOCATION AT TIME OF CONSTRUCTION. LUMINAIRE SCHEDULE LUMINAIRE NO. CITY OF RENTON LUMINAIRE I.D. NUMBER (l LAMP POLE WATTAGE LOCATION C OF POLE MOUNTiNG CURBFACE HEIGHT CIRCUIT NO. REMARKS 1 2567 1 D0 WATT 9 +91 RT -1 °&FT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 2 2566 100 WATT -M.;-40 LT -7 X FT 25 FT. 1 TYPE III LIGHT DISTRIBUTION 3 2564 100 WATT 12+ T 5'f fo 25 FT. 1 TYPE III LIGHT DISTRIBUTION 4 2562 100 WATT 114+qgR 25 FT. 1 TYPE III LIGHT DISTRIBUTION 5 2560 100 WATT 15 +59 RT ,.MFT. 25 FT. 1 TYPE III LIGHT DISTRIBUTION 6 2558 100 WATT 17 +14 R FT. 25 FT. 1 TYPE II! LIGHT DISTRIBUTION 7 2556 100 WATT 18+DeoRT i 25 FT. 1 TYPE III LIGHT DISTRIBUTION 8 2554 100 WATT +.,-� RT 7 - 25 FT. 1 TYPE III LIGHT DISTRIBUTION I _ (1) NUMBER TO BE AFFIXED TO POLE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAIL. I AS - CONSTRUCTED LOCATION of LUMINAIRES Q LUMINAIRE NUMBER 1 POLE CENTERLINE OF POLE I LOCATION FROM CURBFACE 9+91 I 6.65' 2 11 +36 114' 3 12+43 9.9' 4 13 +89 I 9.9' 5 15 +48 ! 6.4' 6 17+03 7.1' 7 ! 18 +36 6.7' 8 20+43 9.7' BREAKER AND CONTACTOR SCHEDULE Roadway Illumination As- Donsttucted locations were deteranned from field survey by Triad Associates. S. 47" Street WIRE NOTES RUN CONDUCTORS CONDUIT I 1 3 NO. 2 (POWER) 1 GREEN NO. 8 (GND) 2" PVC A 4 NO. 10 (IILUM) 2" PVC AND TYPE 1 JUNCTION BOX 1 GREEN NO. 8 (GND) COMBINATION FOUNDATION WITH LUMINAIRE A3 Z4 5 ,� 3 NO. 14 (PEC) 2 NO. 10 (ILLUM) 1 GREEN N0. 8 (GND) 3 NO. 14 (PEC) 2NO. 10 (ILLUM) 1 GREEN NO. 8 (GND) 2NO. 10 (ILLUM) 1 GREEN N0. 8 (GND) 2" PVC 2" PVC 1 -1/2" PVC NOTE: LATERAL CONDUITS SHALL BE PVC SCH. 40. STREET CROSSINGS SHALL BE PVC SCH. 80. CIRCUIT NO LEGEND ® SERVICE VAULT (PSE) REMARKS LIGHTING CONTACTOR CABINET 100 COMBINATION FOUNDATION WITH LUMINAIRE - AND TYPE 1 JUNCTION BOX - COMBINATION FOUNDATION WITH LUMINAIRE 20 AND TYPE 2 JUNCTION BOX ® TYPE 1 JUNCTION BOX --- - - - - -- CONDUIT O CONSTRUCTION NOTE 0 WIRE NOTE SERVICE CABINET (I.D. NO. 0025) BREAKER AND CONTACTOR SCHEDULE Roadway Illumination CIRCUIT NO MAIN BREAKER AMPS BRANCH BREAKER AMPS CONTACTOR AMPS REMARKS MAIN 100 - - 120/240 VOLT 1 ILLUM - 20 30 240 VOLT LL s CITY OF RENTON �. DEPARTMENT OF' PUBLIC WORKS 9 Illumination Plan ROLL # 167 FR rwt REVISION /,�l3 T - 27 71 6-V SCANNED OCT 4 2000 T MEN > � r O 1 A �u =m ; o <r N J a � RECOMMENDED JT FOR APPROVAL BY • DATE -l3- BY DATE 3. L I'$ BY DATE / BY DATE BY DATE i_j LL s CITY OF RENTON �. DEPARTMENT OF' PUBLIC WORKS 9 Illumination Plan Roadway Illumination .Zoo, :......................... Plat of Talbot Rid e DESIGNED D. HAMtIN DATE August 1999 FILE NO FIELD BOOK_ PAOE- 13e oo DRAvm CHECKED D. IAMLIN SCALE 1 "'40' .I APPROVED O SHEET 2 CF 5 DATE /,�l3 T - 27 71 6-V SCANNED OCT 4 2000 T MEN > � r O 1 A �u =m ; o <r N J a � RECOMMENDED JT FOR APPROVAL BY • DATE -l3- BY DATE 3. L I'$ BY DATE / BY DATE BY DATE i_j LL s CITY OF RENTON �. DEPARTMENT OF' PUBLIC WORKS 9 Illumination Plan Roadway Illumination .Zoo, Plat of Talbot Rid e DESIGNED D. HAMtIN DATE August 1999 FILE NO FIELD BOOK_ PAOE- 13e oo DRAvm CHECKED D. IAMLIN SCALE 1 "'40' 0 APPROVED SHEET 2 CF 5 DATE /,�l3 T - 27 71 6-V SCANNED OCT 4 2000 T MEN > � r O 1 A �u =m ; o <r N J a �