HomeMy WebLinkAboutzT-3190SetIs 4 i a 0 M a c 0 o " a g a W W_ w W V CL Z O Z 0 lb rO a PORTION N.W. 1/4, S.W. 1/4, SEC. 29, TWPo 23 N., RGE, 5 E., W.M. tit►.• w -*s o r TR F;i z FE ac kR I. EXISTING PROPOSED TYPE M —C —III H.P.S. LUMINAIRE, ARM AND ALUMINUM DAVIT STYLE POLE LIGHT BASE AND JUNCTION BOX WITH CONCRETE PAD ELECTRICAL SERVICE CABINET PVC CONDUIT (SEE WIRING SCHEDULE) 8 ■ TYPE 1 JUNCTION BOX WITH CONCRETE PAD QWIRE NOTE OCONSTRUCTION NOTE CONSTRUCTION NOTES 1 ROUTE CONDUIT TO EXISTING JUNCTION 80X. INSTALL CONDUCTORS PER WIRING SCHEDULE. 2 INSTALL CONDUCTORS PER HARING SCHEDULE AT EXISTING JUNCTION BOX. SPLICE NEW CONDUCTORS TO EXISTING ILLUMINATION CIRCUIT. POLE SCHEDULE POLE NO. .16- STREET 00 o� LL z E WE � 00 3E MAST ARM CIRCUIT NO. 1 6801 B z,u �- W .0 W a3 o: U 0 M —C —III c" c° cE 8' 1 2 mE WELLS AVE. S. 1 E 22.5' RT. 100 M —C —III v+ 8' c� a� 0 lb rO a PORTION N.W. 1/4, S.W. 1/4, SEC. 29, TWPo 23 N., RGE, 5 E., W.M. tit►.• w -*s o r TR F;i z FE ac kR I. EXISTING PROPOSED TYPE M —C —III H.P.S. LUMINAIRE, ARM AND ALUMINUM DAVIT STYLE POLE LIGHT BASE AND JUNCTION BOX WITH CONCRETE PAD ELECTRICAL SERVICE CABINET PVC CONDUIT (SEE WIRING SCHEDULE) 8 ■ TYPE 1 JUNCTION BOX WITH CONCRETE PAD QWIRE NOTE OCONSTRUCTION NOTE CONSTRUCTION NOTES 1 ROUTE CONDUIT TO EXISTING JUNCTION 80X. INSTALL CONDUCTORS PER WIRING SCHEDULE. 2 INSTALL CONDUCTORS PER HARING SCHEDULE AT EXISTING JUNCTION BOX. SPLICE NEW CONDUCTORS TO EXISTING ILLUMINATION CIRCUIT. POLE SCHEDULE POLE NO. POLE ID NO. STREET POLE LOCATION POLE OFFSET LAMP WATTAGE DISTRIBUTION MOUNTING HEIGHT MAST ARM CIRCUIT NO. 1 6801 B WELLS AVE. S. 86 +05 22.5' RT. 100 M —C —III 25 8' 1 2 6810B WELLS AVE. S. 1 87 +55.5 22.5' RT. 100 M —C —III 25' 8' 1 3 6803B WELLS AVE. S. 88 +90 22.5' RT. 100 M —C —III 25' 8' 1 4 6813B WELLS AVE. S. 90 +42.5 22.5' RT. 100 M —C —III 25' 8' 1 5 6816B S. 35TH ST. 1+69 20.5' LT. 100 M —C —III 25' 8' 1 6 6818B S. 35TH ST. 3 +39 20.5' LT. 100 M —C —III 25' 8' 1 7 6820B S. 35TH ST. 5 +44 26' RT. 1 00 M —C —III 25' 1 8' 1 WIRING SCHEDULE I - 31900I RUN NO. CONDUIT CONDUCTORS REMARKS 1 1.5" PVC (SCHEDULE 40) 2— , 1 — #8 GREEN 2 1.5" PVC (SCHEDULE 80) 2—#89 1—#8 GREEN 3 EXISTING 1.5" 12—#8, 1—#8 GREEN RECOMMENDM FOR APPROVAL By DATE 41W�,.�Q� Byl DATE /A - 0!� By DATE H E HERMAN TRAFFIC ENGINEERING �,� •^awe t�,�' II -p-�Y 15324e 133rd Covet, Rmonk 980S9 °""n afam 425-277-1740 Id. 425- 277- S7lifax htNcpipust,not 1pi90 o 1 An Is AerS 0 9 I J o°• t` r- r a 0 W Z O W Q W I V 0.188 WALL BRACKET ALUM. ALLOY 6063–T6 1/2" BNC LOCKBOLT GR. 18-8 S.S. FLUSH JOINT 4-1/2" O.D. f TAPERED ALUM. POLE 0.188 WALL ALLOY 6063–T6 SATIN GROUND FINISH SIZE AS REQUIRED ::;;iomlw 80 –1 /2" 2" N. P. S. N,0. D. SLIPFI TTER ADIUS 18'-3" SHAFT 151 HANDHOLE. 4 "x6" OPENING W /COVER AND S.S. SCREWS 8" 0. D. BASE FLANGE ALLOY 356 –T6 WITH r-GROUND UG BOLT COVERS do S.S. SCREWS 1' -6" -•I I� -11 -1 /4" SQ. 11" TO 12" D I A 20 ' -0" 25 0 o BOLT CIRCLE 4 1 2" OF BOLT ABOVE E 4" CONCRETE PAD FINI ED GRADE LL_ Z 'E (4) 1 " BNC GALV. STEEL to O 3 ANCHOR BOLTS WITH 4' }- z� NUTS AND WASHERS too f. L LJ a'. a: 30' U P SL 18 –3 DID .cE 28'- 3 33 –3 5 0.188 0.188 mg 6 gill c c 0.1 c a` = 8 DATE I REWSIC SUFFIXED PREFIXED CITY 0 2 N.P.S. SLIPFITTER lb .Ti INNNI 0 ar STANDARD 25 FOOT DAVIT POLE ADOPTED Standard plans LST DATE: 10/30/96 DWG. NAME: JR -01 SP PAGE: J002 SINGLE OR DOUBLE MAST ARM AS Rcni 16ocn 3 14, 2" BY 3/4" REDUCING WASHER 3/4" ROMEX CONNECTOR WITH LOCKNUT . 3R DOUBLE MAST ARM, INSTALL 2ND CABLE BETWEEN LUMINAIRES WHEN BOTH LUMINAIRES ARE ON SAME CIRCUIT MAST ARM WIRING DETAIL 2" STRAIN RELIEF DETAIL ADOP7'SD an a Standard • L9 .w• �I T DA9'�: P10/30/96 DWO. NAME: JR —OS SP PAGE: J000 FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS – S.E.C. OR EQUAL TYPICAL DESIGN "B" JUNCTION BOX SPLICE KITS GROUND LUG CLEAR EPDXY SPLICE KIT ON ALL THRU 2" MIN. GROUT WIRE RUNS UNDER POLE 4" CONCRETE BASE PAD —� 5"� 1111 �` G8GREEN ROUND WIRE 2— (SIZED AS REQ'D) LIGHTING SYSTEM WIRES TO CONTACTOR 5/8 "x8' COPPER–CLAD GROUND ROD - MOUNTING HEIGHT 15 FEET TO LUMINAIRE 8ROUN�P° 4' -PVC CON SYSTEM DUIT CONCRETE FOUNDATION 30 SQ. OR DI A. 1/4n MINIMUM -DRAIN HOLE TOP OF CONCRETE FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. �lll.IlAw 11=�t1= -111 TYPICAL LIGHTING UNDERGROUND SYSTEM ADOPTED cr" or �on+oct st..wwa Pima L9T Um I V96 1 1 (ii) BY APPA DWG. NAME: JR -06 SP PAGE: JO07 INSTALL DECAL NUMBERS VERTICALLY. INSTALL IN DRY WEATHER 50 P OR ABOVE. i� NUMBERING EXAMPLES 1 30' 35' P SL 18 –3 2 28'- 3 33 –3 5 0.188 0.188 3 6 4 7 C 8 LETTER LETTER SUFFIXED PREFIXED CITY PUGET POWER OWNED OWNED 0 ar STANDARD 25 FOOT DAVIT POLE ADOPTED Standard plans LST DATE: 10/30/96 DWG. NAME: JR -01 SP PAGE: J002 SINGLE OR DOUBLE MAST ARM AS Rcni 16ocn 3 14, 2" BY 3/4" REDUCING WASHER 3/4" ROMEX CONNECTOR WITH LOCKNUT . 3R DOUBLE MAST ARM, INSTALL 2ND CABLE BETWEEN LUMINAIRES WHEN BOTH LUMINAIRES ARE ON SAME CIRCUIT MAST ARM WIRING DETAIL 2" STRAIN RELIEF DETAIL ADOP7'SD an a Standard • L9 .w• �I T DA9'�: P10/30/96 DWO. NAME: JR —OS SP PAGE: J000 FUSE KITS QUICK DISCONNECT 10 AMP IN LINE FUSE KITS – S.E.C. OR EQUAL TYPICAL DESIGN "B" JUNCTION BOX SPLICE KITS GROUND LUG CLEAR EPDXY SPLICE KIT ON ALL THRU 2" MIN. GROUT WIRE RUNS UNDER POLE 4" CONCRETE BASE PAD —� 5"� 1111 �` G8GREEN ROUND WIRE 2— (SIZED AS REQ'D) LIGHTING SYSTEM WIRES TO CONTACTOR 5/8 "x8' COPPER–CLAD GROUND ROD - MOUNTING HEIGHT 15 FEET TO LUMINAIRE 8ROUN�P° 4' -PVC CON SYSTEM DUIT CONCRETE FOUNDATION 30 SQ. OR DI A. 1/4n MINIMUM -DRAIN HOLE TOP OF CONCRETE FOUNDATION TO BE LEVEL WITH TOP OF SIDEWALK OR CURB. �lll.IlAw 11=�t1= -111 TYPICAL LIGHTING UNDERGROUND SYSTEM ADOPTED cr" or �on+oct st..wwa Pima L9T Um I V96 1 1 (ii) BY APPA DWG. NAME: JR -06 SP PAGE: JO07 INSTALL DECAL NUMBERS VERTICALLY. INSTALL IN DRY WEATHER 50 P OR ABOVE. i� NUMBERING EXAMPLES CURB 45" TRAFFIC FLOW PLAN VIEW DECAL: RELECTORIZED 2 "- 21 _ w GOTHIC GOLD 21 3 OR WHITE LEGEND ON BLACK BACKGROUND STREET LIGHT STANDARD DECAL NUMBERING SYSTEM ADOPTED a" w Standard plans LST DATIC: 12/96 DWO. NAME: JR -09A SP PAGE: JO09 UW N 0 R/W LINE SIDEWALK CURB C ROADWAY cr CURB SIDEWALK R/W LINE 10' MIN. CLEARANCE FROM DRIVEWAY ALTERNATE PLAN VIEW H 1 30' 35' P SL 18 –3 2 28'- 3 33 –3 5 0.188 0.188 3 6 4 7 C 8 LETTER LETTER SUFFIXED PREFIXED CITY PUGET POWER OWNED OWNED CURB 45" TRAFFIC FLOW PLAN VIEW DECAL: RELECTORIZED 2 "- 21 _ w GOTHIC GOLD 21 3 OR WHITE LEGEND ON BLACK BACKGROUND STREET LIGHT STANDARD DECAL NUMBERING SYSTEM ADOPTED a" w Standard plans LST DATIC: 12/96 DWO. NAME: JR -09A SP PAGE: JO09 UW N 0 R/W LINE SIDEWALK CURB C ROADWAY cr CURB SIDEWALK R/W LINE 10' MIN. CLEARANCE FROM DRIVEWAY ALTERNATE PLAN VIEW H 25' 30' 35' 40' SL 18 –3 23 –3 28'- 3 33 –3 T 0.188 0.188 10.219 0.219 19-2" TAPERED ALUM. POLE 6VETROH 4* T' WALL ALLOY 6063 –T6 SATIN GROUND FINISH ,H, HANDHOLE 4 "x6" OPENING W /COVER do S.S. SCREWS. GROUND LUG INSIDE POLE 1. -6w STREET LIGHT CONDUIT TRENCH DEPTH 24" ALTERNATE STREET CROSS SECTION TYPICAL LIGHT BASE AND JUNCTION BOX CONCRETE PAD 7' -0" VARIABLE 3' -0" -} 10 _ MIN. 1' -6" 4" T P4 �I FRONT VIEW SIDE VIEW TYPICAL JUNCTION BOX "B" CONCRETE PAD 9 4" i ZA dam M T FRONT VIEW SIDE VIEW TYPICAL JUNCTION BOX "C" CONCRETE PAD 4 • IF own m T FRONT VIEW SIDE VIEW r �Y V 11 ^ } M , TYPICAL CONCRETE PAD DETAILS ADOPTED Standard plans LMIT DATE: 10/30/96 DWO. NAME: JR -36A SP PAGE: JO 15 10' UTILITY EASEMENT cr 1,_sr 6VERHANG TO 4' 'H .5 ' 6 'Sl' FACE OF CURB TO CENTER OF ROLE STREET LIGHT CONDUIT TRENCH DEPTH 24" TYPICAL STREET LIGHT FOUNDATION LOCATION (MODIFIED) LIGHT BASE AND JUNCTION BOX LOCATIONS ADOPTED crnr ore+oN 1i) Standard plans LST DATE: 12/96 DWG. NAME: JR -35 SP PAGE: J014 T- 3I9�002 RECOMMENDED FOR APPROVAL BY DATE BY DATE BY D ATE ss=i :1 1�`�► �awL HERMAN TRAFFIC ENGINEERING HIE 15324 SoutMast 133rd Comet, MMon.1INpINn0pi11 99059 s� AM X X Ast 0 O► s h a 0 ITI e e ITEM .L- Box 60 o� Ll- z NOTES: 00 3E F-- Diamond Plate Steel - A786 k u . All dimensions are minimum. Exact configurations vory among different manufacturers. U ' .... Cp c° �E The noted lid thickeners overall minimums. The Diamond Pattern for Type 1 or Type 2 �. �E ' �1 Boxes shill be 28X minimum of overall thickness. vo o.� Lid support members shall be welded to the frame. 4000PSI concrete is allowed if box reinforcement consists of 6 X 6 - W3 X W3 welded wire fabric welded to the frame. When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12' deep extension boxes. When noted in the contract. Type 2 Boxes shall be provided with a 10' X 27 1/2" 10 gage divider plate complete with fasteners. Non - concrete Boxes may be submitted for approval. Evaluation will include on H -20 Load Test. J JUNCTION BOX DIMENSION TABLE I c ~ ITEM QQX TYPE - T 1 tfi TYPE (L 2 W Ll A Box Outside len th 22 22 33 Z Box Outside Width 17 17w 22 1Z2 Box Inside Length 18 19 28 ~ Box Inside Width 13 14 17 _ W Lid Length 18 18 26 1/2 Ce _ Lid Width 13 13 17 PLAN ve• W Box Depth 12w 12 12 _ Lid & Frame Depth 5 16 5/16w 5 16 U Wall Thi knm Min. 1 1 2 1 1 2 1 1 2 We Reinforcement W-3 W-2.5 W-2.5 _ Legend See Detoil See Detail ISn Dotal -' ELEVATION VEw s h a 0 ITI e e ITEM .L- Box 60 o� Ll- z a :_ 00 3E F-- Diamond Plate Steel - A786 �z u . F— Ll zW a'. a. U C Cp c° �E mE �E ' �1 �` °' c vo o.� s h a 0 ITI e e ITEM MATERIALS Box 6000 PSI =x:mte See Notes Frame Diamond Plate Steel - A786 Lid Su art 1 Thick StMI C, L w T. - AN Lid Diamond Plate Steel - A786 Anchors Steel Wire or Tee Plate Reinforcement ASTM A -82 Steel *GALVANIZED STEEL LEGEND DETAIL (Mark W SIGNALS LIGHTING • TS -LT TELEMETRY 7RAFnC SIGNAL SYSTEM LEGEND For►n Letters with 1/8* Wald Bead. Grind off Diamond Pattern before forming letter. L IT-A. r-am. 1LLk*MATION SYSTEM LEGEND EPDXY FILL INLINE SPLICE Le i C GRAbEL PAD COWAVED 'T1t7IC01 ASNCIM eac NSTALLATION DETAILS �' ■ TYPE Y sac 0 TYPE 01' sac HOOK DETAL FILM SybdKIS a M..... w JUNCTION BOX DETAILS ADOPTED affor■IMI Standard plans IST DATE: 11 /89 DWG. NAME: JR -36 SP PAGE: J016 r-r,,nvv r-11 a WYE SPLICE SPLICE KIT a � a. DIAMETER = 7/8" Nunn wnmww� 4- 7/8 "�I LOAD LINE 1/4" FUSE ��4" 1/8" 0 1 /8" CUTTING RINGS Z O ft 4waft*ft 1 9 141 FUSE KIT FUSE KIT & SPLICE KIT DETAILS ADOPTED air w ■nw � i " M. JR -12 SP PAGE: JO 13 LIGHTING STANDARD & JUNCTION BOX 7' ov O ov oov O •o s ov, oo ��� oov `oil , o o O Q o v ►v ,V 0 e PLAN VIEW '° v b ' ' O � � ,0 3 . s e o � 4 � ►o ►0 r o � o �► � O V o v lov ► p� STREET LIGHT POLE VJUNCTION BOX SIDE VIEW INDIVIDUAL JUNCTION BOX ov 00 0 0 b�'q 0 V V, Oiv ►♦ ♦ ♦� ►�� ♦��i� 1' PLAN VIEW 1' 400 1 4" DEEP NOTE: CLASS 'B' CONCRETE TO BE USED IN CONSTRUCTION OF PAD CONCRETE PAD DETAILS ADOPTED Ciff or ■tro Standard plans LST DATE: 10/30/96 DWG. NAME: JR -07 SP PAGE: J008 FFt 0�,t , T- 3/Q003 RECOMMENDED FOR APPROVAL BY DATE BY DATE 8Y DATE HIE HERMAN TRAFFIC ENGINEERING 15324 500h.s:e 133rd eon, Re"M wMI101198011 cos' 42S•277•1740 tell. 425- 277 -571 i fu hq@cofflcast.n" w� w z•.s 0 0 N v Q �< a c, o v a w a E� 0 4 Z g � W Z Z 0 44 j �C W Z W V :3E \E °nN qc_ c�� .c rn c 0 CD zi w Y W vii o v a a Q � w M � � 0 Q S, 0 V) 0 z PORTION N.W. 1/4, S.W. 1/4, SEC. 29, TWP-a 23 N., RGE, 5 E., W.M. mrie.- w —Jr9 e 4 �L 1 J i i \R LEGEND EXISTING L- a� cu v LL �' 00 x._ CL Ir— .o a AND 'U w �-- J a u WATTAGE DISTRIBUTION c ° :o E ARM —v :3E \E °nN qc_ c�� .c rn c 0 CD zi w Y W vii o v a a Q � w M � � 0 Q S, 0 V) 0 z PORTION N.W. 1/4, S.W. 1/4, SEC. 29, TWP-a 23 N., RGE, 5 E., W.M. mrie.- w —Jr9 e 4 �L 1 J i i \R LEGEND EXISTING PROPOSED POLE POLE LAMP TYPE M —C —III H.P.S. LUMINAIRE, ARM �`•'� ��� AND ALUMINUM DAVIT STYLE POLE LIGHT BASE AND JUNCTION BOX ® WITH CONCRETE PAD ELECTRICAL SERVICE CABINET --- -- PVC CONDUIT (SEE WIRING SCHEDULE) e TYPE 1 JUNCTION BOX WITH CONCRETE PAD WIRE NOTE CONSTRUCTION NOTE CONSTRUCTION NOTES O1 ROUTE CONDUIT TO EXISTING JUNCTION BOX. INSTALL CONDUCTORS PER WIRING SCHEDULE. O2 INSTALL CONDUCTORS PER WIRING SCHEDULE AT EXISTING JUNCTION BOX. SPLICE NEW CONDUCTORS TO EXISTING ILLUMINATION CIRCUIT. POLE SCHEDULE i � SSaBo POLE POLE POLE POLE LAMP CONDUCTORS MOUNTING MAST CIRCUIT N0. ID NO. STREET LOCATION OFFSET WATTAGE DISTRIBUTION HEIGHT ARM NO. 1 6801 B WELLS AVE. S. -86 � §-- 22.5' RT. 100 M —C -111 25' 8' 1 2 6810B WELLS AVE. S. 87 +5�.�.57 22.5' RT. 100 M— C--III 25 8 ' 1 3 6803B WELLS AVE. S. 88 +947 J22.5 RT. 100 M —C —III 25' 8' 1 4 6813B WELLS AVE. S. 90 +42.5 22.5' RT. 100 M —C —III 25' 8' 1 5 6816B S. 35TH ST. 1+69.5 20.5 LT. 100 M —C -111 25' 8' 1 6 6818B S. 35TH ST. 3 +3440 20.5' LT. 100 M —C —III 25 8' 1 7 6820B S. 35TH ST. 5 +44 L A _ 26' RT. 100 M —C —III T 25' 8' 1 WIRING SCHEDULE RUN NO. CONDUIT CONDUCTORS REMARKS 1 1.5" PVC (SCHEDULE 40) 2 — #8, 1 — #8 GREEN 2 " 2 ' j PVC (SCHEDULE 80) 2—#8, 1 — #8 GREEN 3 EXISTING 1.5 2 — #8, 1 — #8 GREEN ROLL 20 F IR 5�0 3. A 7"' *a /9 0 04 RECORD WXtWENT BY:— opt��- M, t� -rl -oL RECOMMENDED FOR APPROVAL BY DATE. t/&) lez., 0 �vl I L', r . DATE HIE HERMAN TRAFFIC ENGINEERING 15324 Southeast 133rd Court, Renton, Washington 98059 425- 277 -1740 tel. 42 5 -2 77- 5 718 fax hte@comcast.net .' 'a� �► SCArMEO MAY 1 12006 043 3/970040 SCANNED APR 2 2 s