Loading...
HomeMy WebLinkAboutW-358214CONTRACTOR TO RESTORE CURB, SIDEWALK, FULL WIDTH GRIND AND OVERLAY (2" MIN. DEPTH) AND SHOULDER/LANDSCAPED WHERE HMA CL )j -, COMPACTED DEPTH PER STANDARD SPECIFICATIONS DISTURBED BY CONSTRUCTION TO CITY EDGE GRIND AND TACK STANDARDS, EACH SIDE. ALL SURFACES EXISTING ASPHALT ROADWAY MAINTAIN CONTINUOUS SLOPE EXISTING SUBBASE EXISTING CONCRETE THROUGH EDGE GRIND (NO BREAK) PROVIDE TRENCH RESTORATION SIDEWALK 2% 2% PER DETAIL THIS SHEET. w NATIVE MATERIAL ROADWAY RESTORATIONGRIND AND OVERLAY SCALE NOT TO IN LANDSCAPED OR CULTIVATED AREAS, THE CONTRACTOR SHALL RESTORE THE TRENCH TO MATCH EXISTING GRADE. PROVIDE 8" OF TOPSOIL UNDER NEW SOD. TOPSOIL SHALL BE CLEAN AND FREE FROM ROCKS AND DEBRIS. SEE TECHNICAL PROVISIONS FOR ADDITIONAL INFORMATION. SEE TRENCH DETAIL FOR TRENCH BACKFlLL REQUIREMENTS. LANDSCAPED SURFACE RESTORATION HMA CL )C, COMPACTED PER STANDARD SPECIFICATIONS. DEPTH OF REPLACEMENT PATCH TO BE 1' THICKER THAN EXISTING, 3" MIN. DEPTH SAW CUT ACP, WHEEL CUT BST 0 NOT TO SCALE MAX PAY WIDTH = MAX. TRENCH WIDTH + 24" PATCH TO EXTEND 12" BEYOND TRENCH EXTENTS, BOTH SIDES. IS ial EXISTING ROADWAY SUBBASE 6' MIN. CRUSHED SURFACING TOP COURSE / V COMPACT TO 95% MAX. DRY DENSITY J SEE TRENCH DETAIL FOR TRENCH BACKFlLL CUT AND PATCH ALL PAVEMENT (MDD), MODIFIED PROCTOR. REQUIREMENTS. DAMAGED DURING CONSTRUCTION. TRENCH RESTORATION - PERMANENT PATCH NOT TO SCALE EXISTING CURB, TYP. EXISTING GRASS /LANDSCAPING SEE VALVE BOX DETAIL VALVE BOX BASE, SEE DETAIL THIS SHEET INSTALL VALVE PLUMB AND VERTICAL PRETEST CLUSTERS PRIOR TO INSTALLATION. GATE OR BUTTERFLY VALVE (GATE VALVE SHOWN) VALVE BOX AND MARKER NOTES 1. EACH VALVE SHALL BE PROVIDED WITH AN ADJUSTABLE CAST IRON VALVE BOX OF 5' INSIDE DIAMETER. VALVE BOXES SHALL HAVE A TOP SECTION WITH AND 18" MINIMUM LENGTH. THE VALVE BOX SHALL BE RICH NO. 940 OR APPROVED EQUAL. VALVE BOX EARS SHALL BE PLACE IN LINE WITH THE PIPE IT SERVES. 2. 15" MINIMUM, 36" MAXIMUM FOR OPERATOR NUT. EXTENSION SHALL BE INSTALLED WHEN OPERATOR DEPTH EXCEEDS 36 ". 3. PROVIDE CONCRETE COLLAR IN LANDSCAPED AREAS AND WHERE BRONZE VALVE MARKER IS TO BE INSTALLED. CONCRETE COLLAR MAY BE REDUCED TO 18" SQUARE WHERE APPROVED BY THE CITY. 4. PROVIDE BRONZE VALVE MARKER AT VALVE SPECIFIED AS TO BE NORMALLY CLOSED'. BACKFlLL AROUND VALVE WITH COMPACTED CRUSHED ROCK PROVIDE 4" THICK CONCRETE SUPPORT BLOCK UNDER VALVE, TYP. ISOLATION VALVE DETAIL e NOT TO SCALE I]ULAIIUN VALVE NUMP: 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL FITTINGS REQUIRED TO TRANSITION BETWEEN PIPE AND VALVE. 2. THE CONTRACTOR SHALL CONFIRM THE PROPER OPERATION OF ALL VALVES PRIOR TO FINAL CONNECTION OF VALVE. 3. EXTENSIONS ARE REQUIRED WHEN THE VALVE NUT IS MORE THAN 3.5 FEET BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF ONE (1) FOOT LONG, ONLY ONE EXTENSION PER VALVE. ALL EXTENSIONS ARE TO MADE OF STEEL SIZED AS NOTED, AND PAINTED WITH TWO COATS OF CARBON ELASTIC (ATCO NO. 2221) AS SPECIFIED BY PRESERVATIVE PAINT CO. OR APPROVED EQUAL 4. FOR EXTENSIONS LONGER THAN 4 FEET AND /OR VALVES LARGER THAN 12' DIAMETER, BAR SHALL BE 1Y47 DIAMETER. 5. USE MARKER POST WHEN VALVE IS LOCATED OUT OF TRAVELED WAY OR AT THE DIRECTION OF THE CITY. W- 358214 REVISED TO CONFORM TO CONSTRUCTION RECORDS /"I 9/23/13 RH2 ENGINEERING INC. DATE BRONZE VALVE MARKER a PLAN NOT TO SCALE VALVE BOX AND UD FLUSH WITH GRADE 3000 P.S.I. CONC. COLLAR (36° SO x 8" THICK) 'NTH WIRE FABRIC. VALVE BOX CENTERED OVER OPERATING NUT VALVE - PROFILE N FINISHED GRADE w a VALVE MARKER DETAIL 8 NOT TO SCALE OLYMPIC #13 -55XX OVERLAY RISERS MAY BE USED TO MATCH GRADE. RECESSED HANDLE ADJUST BOX TO MATCH GRADE ALIGN LID TYPE LID OLYMPIC 045 EARS WITH WATER MAIN. ADJUSTABLE TOP SECTION, OLYMPIC VB940 "SEATTLE' SHE, 12" LENGTH TOP OF OPERATING NUT EXTENSION SHALL BE NO MORE THAN 25 FROM FINISHED GRADE VALVE OPERATING NUT EXTENSION, SEE DETAIL THIS SHEET. PROVIDE 36" DIAMETER x 6' THICK CONCRETE RING IF VALVE BOX LOCATED OUTSIDE OF PAVED AREA WATERED AND COMPACTED CRUSHED ROCK AROUND VALVE BOX AND BELOW VALVE ST IRON VALVE BOX BASE, STALL VERTICAL TO PREVENT MING OF OPERATOR. VALVE BOX DETAIL e NOT TO SCALE Yy ENTIRE LENGTH 4.25' DIA. 1/8" MIN. THICKNESS 1/8" MIN. THICKNESS 2" SQUARE 1" CIA SOLID METAL STOCK, LENGTH AS REQUIRED 3y' SET SCREW 2.25' INSIDE MEASUREMENT 2.25" DEPTH OPERATING NUT EXTENSION e NOT TO SCALE U REVISED TO CONFORM TO CONSTRUCTION RECORDS LLC KMP N0. REVISION 13Y REVH C, O° SICNBIk 11/13112 SICNER 11/13/12 ). a cl 4Vj a 0 W F a OQZ 0 L W °fO Wa V Z `Aft a `` 0 C6 Z5 Q Ullftft IL y 0 a Q W � � Z a N MI N E E R S NNER S NTISTS RH2 ENGINEERING, INC. http: / /www rh2.com mailbox&'h2com 1.800.720.8052 BELLINGHAM 3sasoa.onues 454 West Horton Road BOTHELL azs9s saoo 22722 29th Drive SE, Suite 210 EAST WENATCHEE 509.ee6.2900 300 Simon Street, Suite 5 RICHLAND 509.9aBS18r 114 Columbia Point Drive. Suite C SILVERDALE 360.876,7960 2021 NW Mhyre Rd. Suite 107 TACOMA 2.,. 72 loss 621 Pacific Avenue Suite 104 SCALE: SHOWN 0 1" 2" DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG xm: 1 1 Dxx: xo. mm+ :KRS DT2 Sep 23, 2013 REN 110 -093 .W) DATE mrnulc CT— D— DETAILDWG W,--5Se) 14-