Loading...
HomeMy WebLinkAboutS-371001N CO LO O O Cr) Q J a. F- IIr 0 cr O Z i� W Z EX. 8" SS (S -3659) EX. S.S. MANHOLE RIM-388.68 IE= 378.68, 8" S,W) IE= 378.78, 8" (NE) -NEW NOTE: ALL TRENCH RESTORATION SHALL BE PER CURRENT CITY OF RENTON STREET OVERLAY AND TRENCH RESTORATION DETAIL PRIVATE ROAD INT'X / I STA. 17 +24.98, NE 7th St. I STA. 20 +00, OLYMPIC AVE. NE CENTER 20' DRIVEWAY APRON OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHINGTON 98058 PHONE: 425- 260 -3412 CONTACT: DARRELL OFFE, P.E. I I I I I I I I ( I I I I I k� Imo; I\ I II I II IE= 383.80, 8" OUT) IE= 383.90, 8" IN) OLYMPIC AVENUE NE 170LF., 8 -1 PVC SSOS =2.08% r — M-- I- -- - -- -- STM - -- II a RIM =392.0 m J O O + m co 00 m o O) 4 �a MIN -EF ELEV =395.0 A 0o Yp o� op o Z STM u y RIM =393.0 w O + � N 0 W N. FF ELEV =395.0 -o o� v e0 9P n or 0020 'ro RIM = 393.43 IE= 387.43, 8" OUT) IE= 387.60, 6" IN) 22 +00 I- - - -T — —WM T i STM 5------ - - - - -- RIM =394.3 LA 8p 00 Os MIN. FF ELEV =397.0 M:.b£:60o0N .00'66Z ALL SANITARY SIDE SEWER STUBS SHALL BE PVC PLACED AT MINIMUM SLOPE = 2.00 %, TYPICAL. ,aitx EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY: IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND UTILIITES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG, 1- 800 - 424 -5555 - RIM =395.0 �V6£ 0 O q o pp IE= 389.50, 6" 1 000 o -2o I o I� Iz m 4- I Im MIN. FF ELEV -397.0 ysc -I� q a 4Oa 20 I I eb� Q o v,P y' n '%00 o. SHALLOW SANITARY SEWER MANHOLES PER STANDARD I PLAN #400.2 z Z MANHOLE FRAME AND COVER W � J Q 3 PER DRAWING 401. zy � °hx N > I 4' MIN. TO O . 127 MAX. STA. 22 +47.0 A a + 4 a O END PRIVATE SECTION 395: 0 - s 1.3.5' 395 Ir• q N o ............................ .......... 4 a 4• � sy TR. 0 .. 3 ....� �4 °4'. ,d N p OI NOTES, 1. STEPS TO BE PMYPRCPYIENE SAFETY STEPS. 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTONS ARE INSTALLED. ............................... ......... ........... ...... ........... 3. CASTING TO BE PER DRAINING 401. N 4. MANHOLE SECTONS TO BE OF REINFORCED PRECAST CONCRETE S. OPENING SHGULD BE ON DOWNSTREAM SIDE 6. ALL JOINTS SHALL BE GROUTED. 12" STORM 7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES. INCLUDING CHANNEUNG, COATED (SEALED) WITH A HIGH SOIJDS URETHANE COATING: 11 N WASSER MC- AROSHIELD OR APPROVED EOVA-; COIAR OF COATING SHALL BE WHITE. SSO5 =2.08% & RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C -443. ii X. 9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE 1701-F., 8" PVC LARGEST PPE ...... . ...... 385: 10. CONNECTIONS TD MANHO SHALL BE MADE USING WK ADAPTOR, KOR -N -SEAL .. .... . .._... ............ ......... ............ . ............ BOOTS OR APPROVED EQUAL ... 385 1� POBUC WORKS SANITARY MANXOL! BTD. ]DEPARTMENT SNALLOW �-4102 l SSMH 1 SHALLOW -54" o p z OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHINGTON 98058 PHONE: 425- 260 -3412 CONTACT: DARRELL OFFE, P.E. I I I I I I I I ( I I I I I k� Imo; I\ I II I II IE= 383.80, 8" OUT) IE= 383.90, 8" IN) OLYMPIC AVENUE NE 170LF., 8 -1 PVC SSOS =2.08% r — M-- I- -- - -- -- STM - -- II a RIM =392.0 m J O O + m co 00 m o O) 4 �a MIN -EF ELEV =395.0 A 0o Yp o� op o Z STM u y RIM =393.0 w O + � N 0 W N. FF ELEV =395.0 -o o� v e0 9P n or 0020 'ro RIM = 393.43 IE= 387.43, 8" OUT) IE= 387.60, 6" IN) 22 +00 I- - - -T — —WM T i STM 5------ - - - - -- RIM =394.3 LA 8p 00 Os MIN. FF ELEV =397.0 M:.b£:60o0N .00'66Z ALL SANITARY SIDE SEWER STUBS SHALL BE PVC PLACED AT MINIMUM SLOPE = 2.00 %, TYPICAL. ,aitx EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY: IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND UTILIITES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG, 1- 800 - 424 -5555 - RIM =395.0 �V6£ 0 O q o pp IE= 389.50, 6" 1 000 o -2o I o I� Iz m 4- I Im MIN. FF ELEV -397.0 ysc -I� q a 4Oa 20 I I eb� Q o v,P y' n '%00 o. SHALLOW SANITARY SEWER MANHOLES PER STANDARD I PLAN #400.2 z 12/19/2013 1 NO. REVISION SITE SURVEY &MAPPING xol®�N xAI: RY�11IQ" oowT� SCALE D.L. OFFS, P.E. UR VA D.L OFFE, P.E. arcNm DATUM Mme' AT ML SfI1E s Nor o,c nw BY I DATE I APPR I AFBronn �""""mNOL •� CITY OF RENTON Planning /Building /Public Works Dept. 5- 311001 GRAPHIC SCALE 0 10 20 40 1 inch = 20 feet RECOM NDED FOR APPROVAL yl � �Dtel By- Date, By- Date - By, Date- NE 7TH NORTH SHORT PLAT KRRV DEVELOPMENT, LLC SEWER PLAN & PROFILE 3506 NE 7th STREET 09/25/2013 I RANG z Z z n W � J Q 3 zy � °hx N > I O `J STA. 22 +47.0 a m O END PRIVATE SECTION 395: 0 16' 1.3.5' 395 ............................ .......... s r 0 3 OI ......390. .............a ......................................... ............................... ......... ........... ...... ........... ..:.. 390 ........... ........... ............. N 12" STORM 11 N 6" STORM ^I SSO5 =2.08% ii X. 0/: 1701-F., 8" PVC ...... . ...... 385: ... ..Z . ............. .. .... . .._... ............ ......... ............ . ............ .... ... 385 I l SSMH 1 SHALLOW -54" o p z RIM= 389.80 IE= 383.80, 8" OUT) _ Ro 380: IE =383.90, 8"7 N :...... :. rnariSo......... 28LF.,; PVC SS ®17.93% ........ ....... ......... ............... .... N"T�RO ........... ........... .......380, L "J � OLYMPIC AVENUE NE = M oG�o T EX�. S.S. MANHOLE II ron RIM= 388.68 N II II IE- 378.68, 8" S,W) : 21+00 w w -- 22 +00 �....20 +00 ..................................... IE_378.78. 8 "i�NE) -NEW ...................... : ....................................._.............._..............-....---------------------------...._.----------- ............................... z 12/19/2013 1 NO. REVISION SITE SURVEY &MAPPING xol®�N xAI: RY�11IQ" oowT� SCALE D.L. OFFS, P.E. UR VA D.L OFFE, P.E. arcNm DATUM Mme' AT ML SfI1E s Nor o,c nw BY I DATE I APPR I AFBronn �""""mNOL •� CITY OF RENTON Planning /Building /Public Works Dept. 5- 311001 GRAPHIC SCALE 0 10 20 40 1 inch = 20 feet RECOM NDED FOR APPROVAL yl � �Dtel By- Date, By- Date - By, Date- NE 7TH NORTH SHORT PLAT KRRV DEVELOPMENT, LLC SEWER PLAN & PROFILE 3506 NE 7th STREET 09/25/2013 I RANG z n .0 zy � °hx N �O `J O