Loading...
HomeMy WebLinkAboutS-355702w w LL GENERAL NOTES: SURVEY LEGEND-(EXISTTNG LINEWORK) MECHANICAL LINE WORK 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE STARTING WORK AND SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY DISCREPANCIES. NEW OR EXISTING STRUCTURES 2. UNLESS DETAILED, SPECIFIED, OR OTHERWISE INDICATED ON THE IXI WATER VALVE MONUMENT NOT TIED THIS SURVEY DRAWINGS, CONSTRUCTION SHALL BE AS INDICATED IN THE APPLICABLE HYDRANT NEW OR EXISTING STRUCTURES HIDDEN TYPICAL DETAILS AND GENERAL NOTES. TYPICAL DETAILS SHALL APPLY FIRE DEPT. CONNECTION ® FOUND CASED MONUMENT EVEN THOUGH NOT REFERENCED AT SPECIFIC LOCATIONS ON DRAWINGS. R] WATER METER SET PK NAIUALUMINUM WASHER NEW PIPING (TRIPLE LINES) 3. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART 0 POST INDICATOR VALVE STAMPED "PACE CONTROL" NEW PIPING HIDDEN (TRIPLE LINES) — OF WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 0 C MANHOLES (SS /SD) SET 5/8" IRON REBAR W/ YELLOW — — — — — — — ❑ CB C PLASTIC CAP STAMPED L.S. #33130 NEW PIPING (SINGLE LINE) -o- POWER/UTILITY POLE UNLESS OTHERWISE STATED. ABBREVIATIONS C GUYANCHOR NEW PIPING HIDDEN (SINGLE LINE) — — — — — — — z JUNCTION BOX AB ANCHOR BOLT R OR RAD RADIUS LA POWER TRANSFORMER EXISTING PIPING (TRIPLE LINES) _- ABC AGGREGATE BASE COURSE RDCR REDUCER AC ASPHALTIC CONCRETE REC RECORD �_ �j T J POWER/TELEPHONE VAULT AFF ABOVE FINISHED FLOOR REF REFERENCE I'M EXISTING PIPING HIDDEN (TRIPLE LINES) AHR ANCHOR REINF REINFORCE (D) (ING) (MENT) Ul POWER METER CENTER LINES ALM ALARM REQD REQUIRED ❑ TELEPHONE/TV RISER PROPERTY LINES EXISTING PIPING (SINGLE LINE) AL ALUMINUM RFCA RESTRAINED FLANGED COUPLING ADAPTER GAS VALVE RIGHT-OF-WAY LINES — - ----- - - - - -- APPROX APPROXIMATE ,C] GAS METER EASEMENT LINES EXISTING PIPING HIDDEN (SINGLE LINE) — — -- ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS S SEWAGE OR SOUTH / LOT LINES STREET LIGHT AUTO AUTOMATIC SCH SCHEDULE -( DITCH LINE AVG AVERAGE SCV SWING CHECK VALVE X SPOT ELEVATION WATER LINE NEW EQUIPMENT OR PIPING CENTERLINE @ AT SD STORM DRAIN SIGN SANITARY SEWER LINE =_s SE SOUTHEAST o MAILBOX SANITARY SEWER FORCE MAIN EXISTING EQUIPMENT OR PIPING CENTERLINE - -- - -- - - - - -- - - -- BCV BALL CHECK VALVE SIM SIMILAR ROCKERY STORM DRAIN LINE --------------=o---- BSP BLACK STEEL PIPE SP SUMP PUMP GAS LINE c NEW EQUIPMENT BV BALL VALVE SPEC SPECIFICATION _]:' -- CONIFEROUSTREE UNDERGROUND POWER LINES uv SS SANITARY SEWER, GRAVITY -]/� UNDERGROUND TELEPHONE LINES °f NEW EQUIPMENT HIDDEN — — — — — — — C CIVIL, CONDUIT SSFM SANITARY SEWER FORCE MAIN `` UNDERGROUND CABLE TV LINES uTv CA CONCRETE ANCHOR SSMH SANITARY SEWER MANHOLE _% DECIDUOUSTREE OVERHEAD UTILITY LINES ----- ---- -o ','L ---- -- - - - --- EXISTING EQUIPMENT ---- -- - - -° CB CATCH BASIN SST, SSTL STAINLESS STEEL CHAIN LINK FENCE o - - - - - -- o - - - - - -- CHNL CHANNEL STA STATION J "C \N. COTTONWOOD WIRE FENCE a r -' NEW FITTING G CONSTRUCTION JOINT STD STANDARD WOOD FENCE CL OR CENTERLINE STL STEEL ICV IRRIGATION CONTROL VALVE EXISTING TO BE REMOVED CLP CONTROL PANEL SW SOUTHWEST CMP CORRUGATED METAL PIPE S/W SIDEWALK CND CONDUIT NEW PIPING CALL -OUT CO CLEANOUT TEL TELEPHONE COMP COMPACTED TDH TOTAL DYNAMIC HEAD CONC CONCRETE TOC TOP OF CONCRETE BUILDING MATERIALS EXISTING PIPING CALL -OUT CONN CONNECTION TYP TYPICAL CONSTR CONSTRUCTION CONT CONTINUE (D) (OUS) OR CONTROL V OR VLV VALVE VIEW IN SECTION CP CONTROL POINT VERT VERTICAL MATERIAL EXISTING REMOVE NEW CPLG COUPLING VOL VOLUME MECHANICAL SYMBOLS CFR CENTER CLASS "A", AND / O W WEST, WIDTH, WATER "D" CONCRETE E D DRAIN, DEPTH WM WATER METER r� DEG DEGREE W/ WITH CLASS "C" CONCRETE /I /f I�(I SWING CHECK VALVE DET DETAIL W/O WITHOUT / (( (( DIA OR DIAMETER DIM DIMENSION 2W NON - POTABLE WATER STEEL PLUG VALVE �T�T / DIP DUCTILE IRON PIPE � / - DMJT DISMANTLING JOINT YL1L/ 1 / yy DWG DRAWING CAST IRON ASS R �HJ 1Zx� ® E`.'! BALL VALVE E EAST, ELECTRICAL FIBERGLASS T/ EA EACH EL OR ELEV ELEVATION ALUMINUM FLANGED JOINT ELL ELBOW ELEC ELECTRICAL) EMBED EMBEDMENT SOIL ENGR ENGINEER EDP EDGE OF PAVEMENT EQL EQUAL VIEW IN PLAN (NEW SHOWN -- EXISTING SCREENED) WELDED JOINT EQPT EQUIPMENT �. EXIST EXISTING GRATING SPA SLURRY SEAL FRG FLANGE FM FORCE MAIN FRP FIBERGLASS REINFORCED PLASTIC PUSH -ON JOINT FT FOOT, FEET PAVEMENT GP GRINDER PUMP ID INSIDE DIAMETER OR INSIDE DIMENSION SCREWED JOINT IE, I.E. INVERT ELEVATION INVT INVERT L LENGTH LF LINEAR FEET FLANGED COUPLING ADAPTER M MECHANICAL MAX MAXIMUM MDD MAXIMUM DRY DENSITY MECH MECHANICAL MFRS MANUFACTURER'S MH MANHOLE, SANITARY DISMANTLING JOINT MIN MINIMUM MISC MISCELLANEOUS R N NORTH NE NORTH EAST RESTRAINED NO NUMBER FLANGED COUPLING ADAPTER NOM NOMINAL NTS NOT TO SCALE NW NORTHWEST OD OUTSIDE DIAMETER PD PUMPED DRAINAGE PL PROPERTY LINE PMP PUMP RECORD DRAWING IL PSPANEL POUND PER SQUARE INCH THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED PV PLUG VALVE IN PART ON INFORMATION PROVIDED BY OTHERS PVC POLYVINYL CHLORIDE PVMT PAVEMENT THIS DRAWING WAS PREPARED ONLY FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREON AND IS NOT TO BE USED ELSEWHERE Date 2/82012 IL A By DRAWING CROSS REFERENCE DETAIL OR SECTION NIDENTIFICATION DETAIL OR SECTION TAKEN ON THE SAME SHEET AT TITLE DETAIL OR SECTION IS TAKEN ON THE DRAWING INDICATED TYPICAL DETAIL REFERENCE BUBBLE TYPICAL DETAIL NUMBER IDENTIFICATION DETAIL OR SECTION IDENTIFICATION DETAIL OR SECTION REFERENCE BUBBLE DETAIL OR SECTION IS TO BE FOUND ON THE SAME SHEET DETAIL OR SECTION IS TO BE FOUND ON THE DRAWING INDICATED TYPICAL DETAIL IS TO BE FOUND ON THE TYPICAL DETAIL DRAWINGS AT CROSS REFERENCE DESIGN CRITERIA HYDRAULIC REQUIREMENTS PUMP TYPE NUMBER OF PUMPS RATED CAPACITY, EACH PUMP MOTOR HORSEPOWER, EACH PUMP FORCE MAIN SUBMERSIBLE, CHOPPER 2 (1 -DUN, 1- STANDBY) 125 GPM @ 24 FT TDH 5.0 4 INCH, DI 5- 355102 r D �x 9�I D u > TIC/ Oy ��y N o >O nW �a w z� IInn r � I