HomeMy WebLinkAboutS-355712iu a w ELECTRICAL PLAN SYMBOLS ELECTRICAL ONE -LINE SYMBOLS IDENTIFICATION SYMBOLS SWITCHES /RECEPTACLES RACEWAY MEDIUM VOLTAGE LOW VOLTAGE MISCELLANEOUS a S b SINGLE POLE SWITCH e LOW VOLTAGE CIRCUIT BREAKER MOTOR IJ a = DEVICE SWITCHED DESIGNATION a 62 CIRCUIT BREAKER, MEDIUM VOLTAGE b p\ a a = TYPE HP HP = HORSEPOWER RATING ®b = CIRCUIT DESIGNATION EXPOSED CONDUIT - b a = CIRCUIT BREAKER NUMBER c J f MCP =MOTOR CIRCUIT PROTECTOR FULL LOAD AMPS AS NOTED EQUIPMENT IDENTIFICATION b = FRAME SIZE d 0 TM = THERMAL MAGNETIC a Gib IFc= SS = SOLID STATE uJ c 2 = DOUBLE POLE SWITCH A INDICATES BREAK IN CONDUIT RUN b = FRAME SIZE (MANUFACTURER TO DETERMINE a PACKAGED EQUIPMENT FRAME SIZE UNLESS INDICATED) LOAD RATING AS INDICATED c 3 = THREE -WAY SWITCH O` ANSI RELAY DEVICE = NUMBER OF POLES b a= NUMERIC VALUE O 4 = FOUR -WAY SWITCH b a = ANSI DEVICE FUNCTION d = TRIP SETTING (AT = AMP TRIP) b = HP, KW, KVA AS INDICATED INSTRUMENT IDENTIFICATION K =KEY OPERATED SWITCH EXPOSED CONDUIT HIDDEN BEHIND WALLS, b = QUANTITY (AC =MCP CONTINUOUS SETTING) - F = SWITCH AND FUSESTAT HOLDER FLOORS OR OTHER STRUCTURES e = DESIGNATION P = SWITCH AND PILOT LIGHT O a TRANSFORMER I = INTERRUPTING RATING a= DEVICELD. T = THERMOSTAT MEDIUMVOLTAGE EQUIPMENT /INSTRUMENT LOCATOR D = DIMMER SWITCH - - UNDERGROUND CONDUIT, DIRECT BURIED DISCONNECT SWITCH b = KVA RATING OR IN DUCTBANK c c = NUMBER OF PHASES L = LOW VOLTAGE LIGHT SWITCH NON -FUSED CUT OUT O\ M = MANUAL MOTOR STARTER /) --(v) d LUMINAIRE IDENTIFICATION LOW VOLTAGE CIRCUIT BREAKER : � a d= SECOND RY VOLE O AUXILIARY OPERATOR a = SECONDARY VOLTAGE aOX b a = DEVICE SWITCHED FROM - CONDUIT IN FLOOR SLAB 0 =S= SHUNTTRIP c = OCCUPANCY SENSOR /`y MEDIUM VOLTAGE = K = KIRK KEY INTERLOCK Q b CIRCUIT DESIGNATION C = MOUNTING HEIGHT IN FEET TO BOTTOM b a = CIRCUIT DESIGNATION b =DEVICE SWITCHED DESIGNATION SINGLE FUSE CUT OUT = V = SOLENOID OJS /,// DISCONNECTING FUSE =G = GROUND FAULT INTERRUPTER GROUNDED WYE CONNECTION OF FIXTURE . KEY RELEASE � ' CONDUIT VERTICAL CHANGE IN DIRECTION CONDUIT IDENTIFICATION �a SWITCH AND SINGLE RECEPTACLE — Q DELTA CONNECTION O XXXX= CONDUIT NUMBER, Sb a= CIRCUIT DESIGNATION 0 DISCONNECT SWTICH REFER TO CONDUIT SCHEDULE b = DEVICE TYPE DESIGNATION FO a =TYPE REFER TO DISCONNECT SCHEDULE S = SWITCH AND SINGLE RECEPTACLE JQ JUNCTION BOX MEDIUM IUM VOLTAGE %% %��� INDICATES KEYNOTE 1 a DISCONNECTING FUSE L 1/V b INDICATED ON ENGINE-GENERATOR HE DRAWINGS AS (v/) (PERTAINS ONLY TO SHEET WHERE NOTE IS FOUND) �b DUPLEX RECEPTACLE DOUBLE FUSE CUT OUT �- CONDUITSEAL a a = KVA/KW a = CIRCUIT DESIGNATION d b= VOLTAGE/CONNECTION b = DEVICE TYPE DESIGNATION IJ" a c = PHASE O OPERATOR INTERFACE STATION MEDIUM VOLTAGE SINGLE FUSE 1 = STATION TYPE _0 d =WIRE a �O� -�b QUADRUPLEX RECEPTACLE FUSED DISCONNECT SWITCH a =pf a= CIRCUIT DESIGNATION I I a = TYPE, REFER TO DISCONNECT SCHEDULE DUCTBANK - b = DEVICE TYPE DESIGNATION b = FUSE RATING EQUIPMENT ENCLOSURE SPECIAL PURPOSE RECEPTACLE APPROXIMATE DIMENSIONS a a SHOWN ON DUCTBANK SCHEDULE MEDIUM VOLTAGE DOUBLE FUSE I I b ® RATING AS INDICATED ON THE b ® IN FLOOR DUPLEX RECEPTACLE a DRAWINGS GROUNDING a = CIRCUIT DESIGNATION I L� a b = DEVICE TYPE DESIGNATION -1 d a = AMPS b = VOLTAGE/CONNECTION UNDERGROUND GROUND GRID #4/0 SDBC a I c = PHASE UNLESS ROUND GROUND ®b IN FLOOR QUADRUPLEX RECEPTACLE CONDUIT SIZE AND CONDUCTORS MEDIUM VOLTAGE I11��---1f1f d =WIRE a = CIRCUIT DESIGNATION ♦ LIVE FRONT TERMINATOR LJ FUSE O GROUND ROD b = DEVICE TYPE DESIGNATION LLJJ INDIVIDUAL CONDUCTORS a CURRENT TRANSFORMER WITH ® GROUND ROD AND GROUND WELL �a DUPLEX RECEPTACLE w /SPLIT WIRE MEDIUM VOLTAGE ELBOW b SHORTING TERMINAL BLOCK b a = CIRCUIT DESIGNATION W "C -(3 -X TYPE (0), 1-#Y TYPE (N) & 1 -Z TYPE (G)) Q = a = QUANTITY - - COMPRESSION OR EXOTHERMIC b = DEVICE TYPE DESIGNATION b =RATIO _f GROUNDING CONNECTION W "C (WHERE INDICATED): W = CONDUIT TRADE SIZE a 1 MEDIUM VOLTAGE T 0 WELDING OR APPLIANCE RECEPTACLE 3 -X TYPE (0): a a = = QUANTITY TRANSFORMER as b a = CIRCUIT DESIGNATION 3 = QUANTITY ANTNT ITY b = DEVICE TYPE DESIGNATION X = SIZE OF CONDUCTORS A SST SOLID STATE b b = RATIO LUMINAIRES TYPE = INSULATION TYPE TRIP UNIT a WELDING RECEPTACLE (0) = DESIGNATES PHASE CONDUCTORS = b = DISCONNECT TYPE 1 -Y TYPE (N)(WHERE INDICATED): SOLID STATE MEDIUM VOLTAGE CONTACTOR A COMBINATION STARTER SSM MULTIFUNCTION METER 2', 4', OR 8' a CIRCUIT DESIGNATION FLUORESCENT STRIP 1 = QUANTITY -® SPECIAL PURPOSE RECEPTACLE Y = SIZE OF CONDUCTORS i b ❑ a= CIRCUIT DESIGNATION TYPE = INSULATION TYPE b WITH CONTROL POWER TRANSFORMER 2' X 2' LAY-IN TROFFER a = CIRCUIT BREAKER DISCONNECT, ATP b = DEVICE TYPE DESIGNATION (N) DESIGNATES NEUTRAL CONDUCTORS a REFER TO LUMINAIRE SCHEDULE MEDIUM VOLTAGE STARTER p TYPE T NOTED ✓ J AMMETER TEST POINT <$> -0C CLOCK RECEPTACLE 1 -Z TYPE (G)(WHERE INDICATED): 1 b= STARTER TYPE ))) 777 a b c = NEMA STARTER SIZE 2' X 4' LAY -IN TROFFER a = MOUNTING HEIGHT 1 = QUANTITY c d = OVERLOAD HEATERS REFER TO LUMINAIRE SCHEDULE Z = SIZE OF CONDUCTORS O—I -0a FAN RECEPTACLE TYPE = INSULATION TYPE - I MOV -ELBOW ARRESTOR -> i VOLTAGE TEST POINT a = MOUNTING HEIGHT (G) = DESIGNATES GROUND CONDUCTORS _ //^�� d LUMINAIRE POLE MOUNTED U(3 -X TYPE (0) & 1 -X TYPE (G)) O TWIST LOCK RECEPTACLE �`-( a a = AMP RATING U = NUMBER OF PARALLEL RUNS OK - KIRK KEY INTERLOCK O _ ^ STROBE Q a TELEPHONE OUTLET I \ UTILITY METER R= RED b a= MOUNTING HEIGHT MULTI CONDUCTOR CABLES I b 1 d G = GREEN / VARIABLE FREQUENCY DRIVE a K/2/C#16S I I WITH FEATURES AS NOTED A =AMBER DATA COMMUNICATIONS OUTLET b K (WHERE INDICATED) = NUMBER OF PAIRS a =INPUT CONTACTOR a = MOUNTING HEIGHT 21C#16S = TWO CONDUCTOR, 16 GAUGE, TWISTED a b = OUTPUT CONTACTOR - LUMINAIRE, EMERGENCY BATTERY- POWERED I� a DISCONNECT SWTICH SHIELDED PAIR I c I c = BYPASS STARTER d = INPUT CIRCUIT BREAKER - 0-0 0] 1 LIGHTNING ARRESTER a = TYPE, REFER TO DISCONNECT SCHEDULE K/31C#16S I LR LR LINE REACTOR _ LUMINAIRE, EMERGENCY /EXIT BATTERY- POWERED pE PHOTOCELL K (WHERE INDICATED) = NUMBER OF TRIPLETS I VFD 3/C #16S = THREE CONDUCTOR, 16 GAUGE, TWISTED SHIELDED TRIPLETS LL I LL LOAD REACTOR LUMINAIRE, EMERGENCY BATTERY- POWERED REMOTE Oa SMOKE =TYECTOR P N /CX TYPE VSS I b T TRANSIENT VOLTAGE �P I = IONIZATION N = NUMBER OF CONDUCTORS IN THE CABLE L — I SURGE SUPRESSOR P = PHOTOELECTRIC X O = SIZE OF CONDUTORS J LUMINAIRE, SURFACE OR PENDANT MOUNTED d = DUCT DETECTOR TYPE = INSULATION TYPE �( ko FACP FIRE ALARM CONTROL PANEL I IC LUMINAIRE, WALL MOUNTED FIBER OPTIC CABLES I I DRAWOUT CONNECTIONS FF FIRE ALARM PULL STATION FO /N I RVSS I REDUCED VOLTAGE SOLID STATE STARTER - LUMINAIRE, DUAL FLOOD /SPOT, WITH MOTION SENSOR N = NUMBER OF INDIVIDUAL FIBERS IC = INPUT CONTACTOR I� FIRE ALARM HORN /STROBE COMBINATION BC I BC = BYPASS CONTACTOR GROUND F FIRE ALARM STROBE ® ARROW POINETS IN DIRECTION OF EGRESS. DILATED. O FIRE F = E FLOW SWITCH CAPACITOR T = TAMPER SWITCH S-355712 BATTERY O LUMINAIRE, WALL WASHER RECORD DRAWING I THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED L oMP DIGITAL METERING PACKAGE IN PART ON INFORMATION PROVIDED BY OTHERS THIS DRAWING WAS PREPARED ONLY FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED ORIGINAL HEREON AND IS NOT TO BE USED ELSEWHERE STAMPED BY 1 RECORD DRAWINGS -TJW 218/12 BMC PACE ENGINEERS. INC. v ` xoa¢o LAKE WASHINGTON BEACH ADAM LLOYD CLEARY oUs ll NONE ,�, CITY I OF SEPT2010 Date z 18 1zolz 9/10/2010 ALO LIFT STATION REPLACEMENT -� RENTON 46679 DATUM � CJL puxwoxn .I By '• �PCK Planning/Building/Public Works Dept SYMBOLS LEGEND - GE-01 .o.wcww NO. REVISION BY DATE APPR 'DP"O`�a �`"""C0' . BRM 12 16 a � X m -7 D u O m TTV z? m y n -� N N0 °z mm i D z x CIJ��J