Loading...
HomeMy WebLinkAboutT-34301734 3 0 J 0 T 0 U N 1. 0 c i 0 z GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL —A —DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456 -2701 PRIOR TO INSTALLA11ON OF METER BASE. 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER COR STD PLAN #127. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY REPRESENTATIVE. 9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT. SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNEC11ONS TO EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. 0 LEGEND EXISTING NEW DESCRIPTION — @wmen— SIGNAL POLE WITH MAST ARM owolas oL OO ® TYPE I OR PS POLE POLE OEGLLi xxxx EXISTING LUMINAIRE 0-0 DECORATIVE PEDESTRIAN LUMINAIRE &_0 DECORATIVE ROADWAY- LUMINAIRE --A DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE m SIGNAL CONTROLLER CABINET ® ELECTRICAL SERVICE CABINET 0M ITS CABINET x z 11 m O Il JUNCTION BOX TYPE 1, 2, 8 2" j 6 #8 ® 25 —TA VAULT - - -- CONDUIT A WIRE NOTE Q CONSTRUCTION NOTE 1N N F- W W 2 N O U7 ¢ H (n MrW Z J U H WIRE NOTES ®RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS OFFSET 1 2" 2 #8 SEE NOTES BELOW 2 2" 4 #8 SEE NOTES BELOW 3 2" j 6 #8 SEE NOTES BELOW 4 4" 52.3' SPARE 5 4" 1 -96 SMFO SEE NOTES BELOW 6 2" 35' SEE NOTES BELOW 7 EX. SERVICE SEE NOTES BELOW 8 4" EX. 1 -48 SMFO RE —ROUTE "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 40' D 7750NL SERVICE #S2 P43 RAINIER AVE S, STA 29 +27 50.0' RT "DECORATIVE" 60W LED (S— III —FC) 240V 4' NOTES: 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 —#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL —LINE TAPE AND LABELED "CITY OF RENTON ". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S2 & SY — SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) LUMINAIRE # STATION OFFSET LUMINAIRE TYPE LUMINAIRE ARM MOUNTING HEIGHT POLE TYPE CIRCUIT # DECAL # COMMENTS 28 RAINIER AVE S, STA 29 +24 52.3' LT "DECORATIVE" 135W LED (M— II —FC) 240V 6' 35' 40' C 7750NL SERVICE #S2 P42 SHARED POLE "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 40' D 7750NL SERVICE #S2 P43 RAINIER AVE S, STA 29 +27 50.0' RT "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 40' D 7749L SERVICE #S2 29 RAINIER AVE S, STA 29 +94 49.0' RT "DECORATIVE" 135W LED (M— II —FC) 240V 6' 35' 40' C 7751NL SERVICE #S3 30 RAINIER AVE S, STA 30 +64 49.0' LT " DECORATIVE" 135W LED (M— II —FC) 240V 6' 35' 40' B 7752NL SERVICE #S3 31 RAINIER AVE S, STA 31 +01 58.5' RT "DECORATIVE" 135W LED (M— II —FC) 240V 12' 35' 38' B 7753N SERVICE #S3, MODIFIED POLE HEIGHT. 32 RAINIER AVE S, STA 31 +42 55.5' LT "DECORATIVE" 135W LED (M— II —FC) 240V 12' 35' 40' C 7754N SERVICE #S3 33 RAINIER AVE S, STA 32 +70 50.5' LT "DECORATIVE" 135W LED (M— II —FC) 240V 12' 35' 40' B 7756N SERVICE #S3 34 RAINIER AVE S, STA 32 +70 52.3' RT "DECORATIVE" 135W LED (M— II —FC) 240V 12' 35' 35' C 7755N SERVICE #S3, MODIFIED POLE HEIGHT. 35 RAINIER AVE S, STA 33 +22 50.5' LT "DECORATIVE" 135W LED (M— II —FC) 240V 12' 35' 40' C 7758N SERVICE #S3 36 RAINIER AVE S, STA 33 +26 52.3' RT "DECORATIVE" 135W LED (M— II —FC) 240V 12' 35' 40' B 7757N SERVICE #S3 P44 RAINIER AVE S, STA 29 +90 51.0' LT "DECORATIVE" 6OW LED (S— III —FC) 240V 4' 14' 18' D 7760L SERVICE #S3 P45 SHARED POLE "DECORATIVE" 60W LED (S— III —FC) 240V 4' 14' 40' D 7751NL SERVICE #S3 P46 SHARED POLE "DECORATIVE" 6OW LED (S— III —FC) 240V 4' 14' 40' D 7752NL SERVICE #S3 P47 RAINIER AVE S, STA 30 +52 48.0' RT "DECORATIVE" 60W LED S— III —FC 240V 4' 14' 18' D 7759L SERVICE #S3 CONSTRUCTION NOTES O CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, CDR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. ® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. 0 SEE SIGNAL PLANS FOR CONSTRUCTION NOTES REGARDING INSTALLATION OF ADDITIONAL SIGNAL SYSTEM EQUIPMENT. 10 FOR EXISTING JUNCTION BOX REMOVAL /MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. 17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS ". 19 MODIFIED POLE HEIGHT TO MAINTAIN 35' MOUNTING HEIGHT ABOVE ROADWAY. SEE LUMINAIRE SCHEDULE. 0 T-3430113 0 5 10 20 40 60 BID SCALE IN FEET DOCUMENTS ADDENDUM #2, REMOVED PRIVATE POLE REMOVAL NOTES JJA JI- 12 -16 -11 11 -14 -11 SURVEYED: KPG wn FqS DRAWN BY: JM KPG'r �L CITY OF RENTON RAINIER AVENUE S (SR ST DRAWING No. 233 _LL S GRADY WAY TO S 2ND ST PROJECT NO. TED403430 DESIGN BY: JF FEHR & PEERS 7530 AveN 2502JefiersoAAve Public Works Department CHECK BY: JF TRANSPORTATION CONSULTANTS Sea81e,WA98109 Tacoma, WA 9M02 ILLUMINATION AND INTERCONNECT PLAN FED AID NO. CM0167(048) w.n,o„i,a .om4,ww.o. APPR D FOR CONSTRUCTION DATE: NOV 2011 s 4s 4 o Wt 4M M.. w.o ", (206)2861840 (253) 627 -0720 Ik ec, rEaE PROJ MGR: TN Wt. 3 fssi Na�� seam. wA 9eis4 °"� mGU o -� u.� www.kpg.com SHEET NO. 233 OF 304 NUMBER REVISION DESCRIPTION BY APP. DATE ONALE FILE:0655DILL01.dwg �2W�576 -4M0 .�".w. .d,.".w BY: DATE./ �f STA 29 +00 TO STA 33 +50 a z �y M m ti N Oa c G n CA yO wa v a .p K I.` o VII 0 c