LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "SY - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238)
LUMINAIRE
#
STATION
SIGNAL CONTROLLER CABINET
OFFSET
®
LUMINAIRE TYPE
1
2
LUMINAIRE
ARM
MOUNTING,
HEIGHT
POLE
TYPE
CIRCUIT
#
DECAL
#
3
4
5
6
COMMENTS
Cl
37
38
*
RAINIER AVE S,
RAINIER AVE S,
STA
STA
35 +08
35 +OS
*
47.5
47.5'
LT
RT
"DECORATIVE" ( )- 0 /
ORATIVE L13D5W LED F(M 2110FC) 240VOCELL
DECORATIVE 135W LED M -II -FC 240V
"DECORATIVE" 135W LED (M- II -FC) 240V
*
6
6'
*
35
35'
*
40
40'
A
A
B
C
7761N
7762N
7764NL
7763NL
* SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN
*SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN
SERVICE #S3
SERVICE #S3
39
RAINIER AVE S
STA
36 +64
147.5'
LT
—
"DECORATIVE"
135W LED (M- II -FC)
240V
6'
35'
40'
C
7766NL
SERVICE
#S3
40
41
42
P48
RAINIER AVE S.
RAINIER AVE S,
RAINIER AVE S,
SHARED
STA
STA
STA
POLE
36 +64
37 +96
37 +96
'147.5'
RT
BY THE ENGINEER IN THE FIELD.
°DECORATIVE"
135W LED (M- II -FC)
C)
240V
2
6'
35'
40'
B
7765NL
SERVICE
#S3
-- -
47.5' LT
47.5' RTI
-- - - -- -- --
"DECORATIVE" 135W LED (M- II -FC) 240V
'DECORATIVE' 135W LED (M-1 - I- - FC) 240V-
"DECORATIVE" 60W— LED III -FC) 240V
--
6'
6'
4'
--
35 4O'
- - --
B 7768NL_ SERVICE
#S3
35' 40'
C 7767NL SERVICE
D 7764NL SERVICE
#S3
#S3
14' 40'
P49
PM
P51
P52
P53
P54
P55
SHARED
RAINIER AVE S,
RAINIER AVE S,
SHARED
SHARED
RAINIER AVE S,
RAINIER AVE S,
POLE
STA
STA
POLE
POLE
STA
STA
35 +97
35 +93
37+33
37 +47
47.5'
47.5'
47.5'
47.5'
LT'
RT'
LT'
RTj
CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY
"DECORATIVE"
"DECORATIVE"
"DECORATIVE"
"DECORATIVE
-(S-
60W LED (S- III -FC)
60W LED (S- III -FC)
60W LED (S III -FC)
60W LED (S- III -FC)
240V
240V
240V
240V
4'
4'
14'
40'
D
D
7763NL
7770L
SERVICE
SERVICE
#S3
#S3
14' 18'
4'
14' 18'
14' 40'
D 7769E SERVICE
D 7766NL SER VICE
#S3
#S3
4'
"DECORATIVE 60W LED (S- III -FC) 240V
"DECORATIVE" 60W LED (S- III -FC) 240V
"DECORATIVE" 60W LED (S- III -FC) 240V
4'
4'
14' 40'
14' 18'
_
D 7765NL SERVICE
#S3
D 7772L SERVICE
#S3
4'
14' 18'
D 7771L SERVICE
#S3
P56
P57
SHARED
SHARED
POLE
POLE
-
-- -
j
--
"DECORATIVE" RATIVE"
60W LED (S- III -FC)
240V
4' _
- - -
4'
14' i
40'
D
7768NL
SERVICE
#S3
- - — — — - -- -- --
"DECORATIVE" 60W LED (S- III -FC) 240V
14' 40'
1 D 7767NL SERVICE
#S3
CCGI
LEGEND
EXISTING NEW DESCRIPTION
SIGNAL POLE WITH MAST ARM
DENOTES a. • TYPE I OR PS POLE
POLE DECAL{
xxxx
EXISTING LUMINAIRE
O- DECORATIVE PEDESTRIAN LUMINAIRE
&_0 DECORATIVE ROADWAY LUMINAIRE
DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE
RAINIER AVE S
rtL
5
r I 37
I I �
1
10 I I 13 1 13 2 13 1
F 13
\096H
35
I I
'I II
II 7 I
it I
I c
iSTA —
0 l_
I I
I I EXTR
13
I
EXTR
SERVICE "S3 "Q3
SEE SIGNAL PLAN
FOR DETAILS
L>_1
m
SIGNAL CONTROLLER CABINET
CONDUCTORS
®
ELECTRICAL SERVICE CABINET
1
2
MI
ITS CABINET
l 11,
m O 0
JUNCTION BOX TYPE 1, 2, 8
3
4
5
6
2"
4"
4"
2"
6 #8
1 -96
SMFO
0
25 -TA VAULT
TPARE
CONDUIT
SEE NOTES BELOW
7
WIRE NOTE
Z
O
CONSTRUCTION NOTE
SEE NOTES BELOW
8
094H
EX 1 -48 SMFO
X",
cc� � — —
--,t—
—
-- -=
ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID 9.
FOR LOCATIONS OF
5 - �
RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER
PRIVATE LUMINAIRES TO BE
CDR STD PLAN #127.
REMOVED, SEE SITE
6.
CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL
PREPARATION PLANS.
LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED
GRIND DOWN EXISTING
BY THE ENGINEER IN THE FIELD.
FOUNDATION TO 2' BELOW
7.
NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE
PROPOSED GRADE AND CAP
THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL).
AND ABANDON EXISTING
IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL
UNUSED CONDUIT. SPLICE
36
095H
4 --
1Cc
17 0 5 10 20 40 60
SCALE IN FEET
rl �
ADDENDUM #2. REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12 -16 -11 SURVEYED' KPG
WAS Is, DRAWN BY: JIM_
DESIGN BY' JF FEHR SL PEERS
CHECK BY. JF . TRANSPORTATION CONSULTANTS
n5 n 4r� . -. - -__ W414 Ale E
01 ^'ec, lka �'� PROJ MGR: TN 9uL.
FSSIONAL EN�A - 203115/6 A %_0 G
NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DILL01.dwg u
CONSTRUCTION NOTES
Qi CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE,
POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL
INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL
PROVISIONS.
O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, 'WRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND
DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS.
SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS.
O CONSTRUCT FOUNDATION PER DETAILS ON SHEET 263 AND FURNISH AND INSTALL ELECTRICAL SERVICE CABINET PER COR STD
DWGS J010 AND J011 WITH BACK -TO -BACK BATTERY BACKUP SYSTEM PER SPECIAL PROVISIONS. FOR LOCATION AND PANEL
SCHEDULE, SEE ILLUMINATION CIRCUIT DIAGRAM AND DETAILS SHEET 238. COORDINATE CONNECTION DETAILS TO THE POWER
SOURCE WITH THE POWER COMPANY REPRESENTATIVE PRIOR TO INSTALLATION OF FOUNDATION. SEE SPECIAL PROVISIONS.
® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION.
O LUMINAIRE TO BE PART OF A SIGNAL SYSTEM. APPLY DECAL NUMBERING TO POLE, FOR ADDITIONAL INSTALLATION DETAILS SEE
SIGNAL PLANS.
O
Q7 EXISTING SIGNAL POLE MOUNTED LUMINAIRE. FOR REMOVAL NOTES SEE SIGNAL PLANS.
10 FOR EXISTING JUNCTION BOX REMOVAL /MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS.
13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING.
INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF
14 TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION.
17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS ".
WIRE NOTES
I \ ) A /A --
6
EXTR 2
GENERAL NOTES
1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS &
SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE
CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS.
2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT
TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION.
3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE
ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH
PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425)
456 -2701 PRIOR TO INSTALLATION OF METER BASE.
4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR
SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION.
CITY OF RENTON
.0
753 ft Ave N 2502Je8ewAve Pub is Woras Deportment
Sw*,WA98109 Tacoma, WA 98402 APP O D FOR CONSTRUCTION
(206)286.1640 (253) 627-0720
NWN.kpg.COm BY DATE' H!L✓//2
L0
M
N
LLJ
x
O
O
rl)
M
F-
®RACEWAY/:;
CONDUIT
SIZE
CONDUCTORS
1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE
COMMENTS
1
2
2" i
2"
2 #8
4 #8
=
SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL-LINE
SEE NOTES BELOW
SEE NOTES BELOW
3
4
5
6
2"
4"
4"
2"
6 #8
1 -96
SMFO
SEE NOTES BELOW
TPARE
SEE NOTES BELOW
SEE NOTES BELOW
7
EX.
Z
EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80.
ALL FIBER CONDUIT
SEE NOTES BELOW
8
4" i
EX 1 -48 SMFO
RE -ROUTE
NOTES (CONTINUED)
5.
ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID 9.
FOR LOCATIONS OF
RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER
PRIVATE LUMINAIRES TO BE
CDR STD PLAN #127.
N
NOTES:
w
1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE
MIN 1 -#8
GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED
IN THE WIRE
=
SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL-LINE
TAPE AND LABELED "CITY OF RENTON ".
2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID
PVC SCH 40,
Z
EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80.
ALL FIBER CONDUIT
AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE
FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS.
GENERAL
NOTES (CONTINUED)
5.
ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID 9.
FOR LOCATIONS OF
RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER
PRIVATE LUMINAIRES TO BE
CDR STD PLAN #127.
REMOVED, SEE SITE
6.
CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL
PREPARATION PLANS.
LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED
GRIND DOWN EXISTING
BY THE ENGINEER IN THE FIELD.
FOUNDATION TO 2' BELOW
7.
NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE
PROPOSED GRADE AND CAP
THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL).
AND ABANDON EXISTING
IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL
UNUSED CONDUIT. SPLICE
INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED.
EXISTING WIRING IF
8.
ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN
NECESSARY TO MAINTAIN
ACCORDANCE WITH SECTION 8-20.3(1)A OF THE SPECIFICATIONS. THE
CONNECTIONS 10NS AI EXISTING
PRIVATE LUMINAIRES TO
CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE
REMAIN. BACKFILL AND
ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE
COMPACT ALL VOIDS PER
CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY
SPECIAL PROVISIONS.
REPRESENTATIVE.
BID
1
0
DOCUMENTS
RAINIER AVENUE S (SR 167)
DRAWING No. _234_
S GRADY WAY TO S 2ND ST
PROJECT NO. TE 403400
ILLUMINATION AND INTERCONNECT PLAN
FEDAIDNO. CM0167000)
DATE: NOV 2011
STA 33 +50 TO STA 38 +00
SHEET NO. 234 OF 904_
D
z
m
a
a
n
� O
� v
I
C)
A a
a �
� w
o O
N