Loading...
HomeMy WebLinkAboutT-3430174G 0 v a 3 C O T U i 0 v rn 0 i 0 a rn 0 i J CL F— I et N I A `C2 rl) N LO r� M 13 V) L e Lm - ®j J Q I x. rNwhiL a 34 w LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "SY - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238) LUMINAIRE # STATION SIGNAL CONTROLLER CABINET OFFSET ® LUMINAIRE TYPE 1 2 LUMINAIRE ARM MOUNTING, HEIGHT POLE TYPE CIRCUIT # DECAL # 3 4 5 6 COMMENTS Cl 37 38 * RAINIER AVE S, RAINIER AVE S, STA STA 35 +08 35 +OS * 47.5 47.5' LT RT "DECORATIVE" ( )- 0 / ORATIVE L13D5W LED F(M 2110FC) 240VOCELL DECORATIVE 135W LED M -II -FC 240V "DECORATIVE" 135W LED (M- II -FC) 240V * 6 6' * 35 35' * 40 40' A A B C 7761N 7762N 7764NL 7763NL * SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN *SEE SIGNAL PLANS FOR INFORMATION NOT SHOWN SERVICE #S3 SERVICE #S3 39 RAINIER AVE S STA 36 +64 147.5' LT — "DECORATIVE" 135W LED (M- II -FC) 240V 6' 35' 40' C 7766NL SERVICE #S3 40 41 42 P48 RAINIER AVE S. RAINIER AVE S, RAINIER AVE S, SHARED STA STA STA POLE 36 +64 37 +96 37 +96 '147.5' RT BY THE ENGINEER IN THE FIELD. °DECORATIVE" 135W LED (M- II -FC) C) 240V 2 6' 35' 40' B 7765NL SERVICE #S3 -- - 47.5' LT 47.5' RTI -- - - -- -- -- "DECORATIVE" 135W LED (M- II -FC) 240V 'DECORATIVE' 135W LED (M-1 - I- - FC) 240V- "DECORATIVE" 60W— LED III -FC) 240V -- 6' 6' 4' -- 35 4O' - - -- B 7768NL_ SERVICE #S3 35' 40' C 7767NL SERVICE D 7764NL SERVICE #S3 #S3 14' 40' P49 PM P51 P52 P53 P54 P55 SHARED RAINIER AVE S, RAINIER AVE S, SHARED SHARED RAINIER AVE S, RAINIER AVE S, POLE STA STA POLE POLE STA STA 35 +97 35 +93 37+33 37 +47 47.5' 47.5' 47.5' 47.5' LT' RT' LT' RTj CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY "DECORATIVE" "DECORATIVE" "DECORATIVE" "DECORATIVE -(S- 60W LED (S- III -FC) 60W LED (S- III -FC) 60W LED (S III -FC) 60W LED (S- III -FC) 240V 240V 240V 240V 4' 4' 14' 40' D D 7763NL 7770L SERVICE SERVICE #S3 #S3 14' 18' 4' 14' 18' 14' 40' D 7769E SERVICE D 7766NL SER VICE #S3 #S3 4' "DECORATIVE 60W LED (S- III -FC) 240V "DECORATIVE" 60W LED (S- III -FC) 240V "DECORATIVE" 60W LED (S- III -FC) 240V 4' 4' 14' 40' 14' 18' _ D 7765NL SERVICE #S3 D 7772L SERVICE #S3 4' 14' 18' D 7771L SERVICE #S3 P56 P57 SHARED SHARED POLE POLE - -- - j -- "DECORATIVE" RATIVE" 60W LED (S- III -FC) 240V 4' _ - - - 4' 14' i 40' D 7768NL SERVICE #S3 - - — — — - -- -- -- "DECORATIVE" 60W LED (S- III -FC) 240V 14' 40' 1 D 7767NL SERVICE #S3 CCGI LEGEND EXISTING NEW DESCRIPTION SIGNAL POLE WITH MAST ARM DENOTES a. • TYPE I OR PS POLE POLE DECAL{ xxxx EXISTING LUMINAIRE O- DECORATIVE PEDESTRIAN LUMINAIRE &_0 DECORATIVE ROADWAY LUMINAIRE DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRE RAINIER AVE S rtL 5 r I 37 I I � 1 10 I I 13 1 13 2 13 1 F 13 \096H 35 I I 'I II II 7 I it I I c iSTA — 0 l_ I I I I EXTR 13 I EXTR SERVICE "S3 "Q3 SEE SIGNAL PLAN FOR DETAILS L>_1 m SIGNAL CONTROLLER CABINET CONDUCTORS ® ELECTRICAL SERVICE CABINET 1 2 MI ITS CABINET l 11, m O 0 JUNCTION BOX TYPE 1, 2, 8 3 4 5 6 2" 4" 4" 2" 6 #8 1 -96 SMFO 0 25 -TA VAULT TPARE CONDUIT SEE NOTES BELOW 7 WIRE NOTE Z O CONSTRUCTION NOTE SEE NOTES BELOW 8 094H EX 1 -48 SMFO X", cc� � — — --,t— — -- -= ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID 9. FOR LOCATIONS OF 5 - � RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER PRIVATE LUMINAIRES TO BE CDR STD PLAN #127. REMOVED, SEE SITE 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL PREPARATION PLANS. LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED GRIND DOWN EXISTING BY THE ENGINEER IN THE FIELD. FOUNDATION TO 2' BELOW 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE PROPOSED GRADE AND CAP THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). AND ABANDON EXISTING IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL UNUSED CONDUIT. SPLICE 36 095H 4 -- 1Cc 17 0 5 10 20 40 60 SCALE IN FEET rl � ADDENDUM #2. REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12 -16 -11 SURVEYED' KPG WAS Is, DRAWN BY: JIM_ DESIGN BY' JF FEHR SL PEERS CHECK BY. JF . TRANSPORTATION CONSULTANTS n5 n 4r� . -. - -__ W414 Ale E 01 ^'ec, lka �'� PROJ MGR: TN 9uL. FSSIONAL EN�A - 203115/6 A %_0 G NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DILL01.dwg u CONSTRUCTION NOTES Qi CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE, POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, COR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL PROVISIONS. O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, 'WRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS. SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS. O CONSTRUCT FOUNDATION PER DETAILS ON SHEET 263 AND FURNISH AND INSTALL ELECTRICAL SERVICE CABINET PER COR STD DWGS J010 AND J011 WITH BACK -TO -BACK BATTERY BACKUP SYSTEM PER SPECIAL PROVISIONS. FOR LOCATION AND PANEL SCHEDULE, SEE ILLUMINATION CIRCUIT DIAGRAM AND DETAILS SHEET 238. COORDINATE CONNECTION DETAILS TO THE POWER SOURCE WITH THE POWER COMPANY REPRESENTATIVE PRIOR TO INSTALLATION OF FOUNDATION. SEE SPECIAL PROVISIONS. ® EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. O LUMINAIRE TO BE PART OF A SIGNAL SYSTEM. APPLY DECAL NUMBERING TO POLE, FOR ADDITIONAL INSTALLATION DETAILS SEE SIGNAL PLANS. O Q7 EXISTING SIGNAL POLE MOUNTED LUMINAIRE. FOR REMOVAL NOTES SEE SIGNAL PLANS. 10 FOR EXISTING JUNCTION BOX REMOVAL /MODIFICATION CONSTRUCTION NOTES SEE SIGNAL PLANS. 13 SEE WIRE SCHEDULE ON SIGNAL PLANS FOR CONDUIT CONTAINING SIGNAL WIRING. INSTALL 1" GRS CONDUIT FROM JUNCTION BOX TO BUS SHELTER FOOTING. REFER TO METRO STANDARDS FOR CONSTRUCTION OF 14 TRANSIT PASSENGER FACILITIES AND DETAILS, SHEET 27 FOR CONDUIT STUB LOCATION. 17 INSTALL NEW TYPE 8 TRAFFIC RATED JUNCTION BOX. LID SHALL BE LABELED "ITS ". WIRE NOTES I \ ) A /A -- 6 EXTR 2 GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425) 456 -2701 PRIOR TO INSTALLATION OF METER BASE. 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. CITY OF RENTON .0 753 ft Ave N 2502Je8ewAve Pub is Woras Deportment Sw*,WA98109 Tacoma, WA 98402 APP O D FOR CONSTRUCTION (206)286.1640 (253) 627-0720 NWN.kpg.COm BY DATE' H!L✓//2 L0 M N LLJ x O O rl) M F- ®RACEWAY/:; CONDUIT SIZE CONDUCTORS 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE COMMENTS 1 2 2" i 2" 2 #8 4 #8 = SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL-LINE SEE NOTES BELOW SEE NOTES BELOW 3 4 5 6 2" 4" 4" 2" 6 #8 1 -96 SMFO SEE NOTES BELOW TPARE SEE NOTES BELOW SEE NOTES BELOW 7 EX. Z EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT SEE NOTES BELOW 8 4" i EX 1 -48 SMFO RE -ROUTE NOTES (CONTINUED) 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID 9. FOR LOCATIONS OF RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER PRIVATE LUMINAIRES TO BE CDR STD PLAN #127. N NOTES: w 1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 -#8 GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE = SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL-LINE TAPE AND LABELED "CITY OF RENTON ". 2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40, Z EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS. GENERAL NOTES (CONTINUED) 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID 9. FOR LOCATIONS OF RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER PRIVATE LUMINAIRES TO BE CDR STD PLAN #127. REMOVED, SEE SITE 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL PREPARATION PLANS. LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED GRIND DOWN EXISTING BY THE ENGINEER IN THE FIELD. FOUNDATION TO 2' BELOW 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE PROPOSED GRADE AND CAP THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). AND ABANDON EXISTING IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL UNUSED CONDUIT. SPLICE INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. EXISTING WIRING IF 8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN NECESSARY TO MAINTAIN ACCORDANCE WITH SECTION 8-20.3(1)A OF THE SPECIFICATIONS. THE CONNECTIONS 10NS AI EXISTING PRIVATE LUMINAIRES TO CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE REMAIN. BACKFILL AND ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE COMPACT ALL VOIDS PER CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY SPECIAL PROVISIONS. REPRESENTATIVE. BID 1 0 DOCUMENTS RAINIER AVENUE S (SR 167) DRAWING No. _234_ S GRADY WAY TO S 2ND ST PROJECT NO. TE 403400 ILLUMINATION AND INTERCONNECT PLAN FEDAIDNO. CM0167000) DATE: NOV 2011 STA 33 +50 TO STA 38 +00 SHEET NO. 234 OF 904_ D z m a a n � O � v I C) A a a � � w o O N