LEGEND
EXISTING
DENOTES EX
ME Derx1
xxxx
NEW DESCRIPTION
@mm — SIGNAL POLE WITH MAST ARM
• TYPE I OR PS POLE
GENERAL NOTES
1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS &
SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE
CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS.
2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT
TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION.
3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE
ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH
PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425)
456 -2701 PRIOR TO INSTALLATION OF METER BASE.
4. THE LOCATON OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR
SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION.
5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID
RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER
CDR STD PLAN #127.
6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL
LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED
BY THE ENGINEER IN THE FIELD.
7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE
THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL).
IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL
INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED.
8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN
ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE
CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE
ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE
CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY
REPRESENTATIVE.
9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE `1
PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW
PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT.
SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO
EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL
VOIDS PER SPECIAL PROVISIONS.
Ln
M
N
H
w
w
N
O
0
N
L0
w
z
J
LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S4 & S5" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238)
LUMINAIRE,
#
EXISTING LUMINAIRE
`1-0
DECORATIVE PEDESTRIAN LUMINAIRE
�--
DECORATIVE ROADWAY LUMINAIRE
SEE
DECORATIVE PEDESTRIAN /ROADWAY LUMINAIRI
m
SIGNAL CONTROLLER CABINET
®
ELECTRICAL SERVICE CABINET
EM
ITS CABINET
m LI D1
JUNCTION BOX TYPE 1, 2, 8
SEE NOTES BELOW
3
m
25 —TA VAULT
----
CONDUIT
A
WIRE NOTE
O
CONSTRUCTION NOTE
GENERAL NOTES
1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS &
SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE
CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS.
2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT
TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION.
3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE
ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH
PUGET SOUND ENERGY REPRESENTATIVE SHERI CLARKE AT (425)
456 -2701 PRIOR TO INSTALLATION OF METER BASE.
4. THE LOCATON OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR
SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION.
5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID
RESISTANT LIDS. ALL JUNCTION BOXES SHALL HAVE LOCKING LIDS PER
CDR STD PLAN #127.
6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL
LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED
BY THE ENGINEER IN THE FIELD.
7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE
THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL).
IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL
INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED.
8. ILLUMINATION SHALL BE MAINTAINED DURING CONSTRUCTION IN
ACCORDANCE WITH SECTION 8- 20.3(1)A OF THE SPECIFICATIONS. THE
CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE
ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE
CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY
REPRESENTATIVE.
9. FOR LOCATIONS OF PRIVATE LUMINAIRES TO BE REMOVED, SEE SITE `1
PREPARATION PLANS. GRIND DOWN EXISTING FOUNDATION TO 2' BELOW
PROPOSED GRADE AND CAP AND ABANDON EXISTING UNUSED CONDUIT.
SPLICE EXISTING WIRING IF NECESSARY TO MAINTAIN CONNECTIONS TO
EXISTING PRIVATE LUMINAIRES TO REMAIN. BACKFILL AND COMPACT ALL
VOIDS PER SPECIAL PROVISIONS.
Ln
M
N
H
w
w
N
O
0
N
L0
w
z
J
LUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "S4 & S5" - SEE CIRCUIT AND PANEL SCHEDULES SHEET 238)
LUMINAIRE,
#
FOR
STATION
BOX REMOVAL /MODIFICATION
OFFSET
LUMINAIRE TYPE
SEE
LUMINAIRE
MOUNTING
POLE
CIRCUIT
DECAL
COMMENTS
2
I, 2"
4 #8
SEE NOTES BELOW
3
2"
6 #8
SEE NOTES BELOW
4
4"
SPARE - -
5
ARM
HEIGHT
TYPE
#
#
_
SEE NOTES BELOW
47
RAINIER
AVE
S,
STA
42 +28
52.0'
LT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
C
7786NL
SERVICE
#S4
48
RAINIER
AVE
S,
STA
42 +28
52.0'
RT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
B
7785NL
SERVICE
#S4
49
RAINIER
AVE
S,
STA
43 +52
58.5'
LT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
12'
35'
40'
! B
7788N
SERVICE
#S4
50
RAINIER
AVE
S,
STA
43 +48
56.5'
RT
"DECORATIVE"
135W
LED
(M- II -FC)
240V
6'
35'
40'
C
7787NL
SERVICE
#S4
P66
SHARED
POLE
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
40'
j D
7786NL
SERVICE
#S4
P67
SHARED
POLE
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
14'
40'
D
7785NL
SERVICE
#S4
P68
RAINIER
AVE
S,
STA
43 +08
53.5'
LT
"DECORATIVE"
60W
LED
(S- III -FC)
240V
4'
1C-
9
1 D
7790L
SERVICE
#S4
51
RAINIER
AVE
S,
STA
44 +51
56.5'
RT
"DECORATIVE"
135W
LED
M -II -FC
240V
1 12'
1 35'
1 40'
C
7789N
I SERVICE
#S5
CONSTRUCTION NOTES
Oj CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS SHEET 239. FURNISH AND INSTALL DECORATIVE LUMINAIRE,
POLE, ARM, CONDUIT /WIRING ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL
INSTALLATION DETAILS SEE ILLUMINATION SHEET 239, CDR STANDARD DRAWINGS J007, J008, J009, J013, J015 AND SPECIAL
PROVISIONS.
O REMOVE EXISTING LUMINAIRE POLE, LUMINAIRE, JUNCTION BOX, WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. GRIND
DOWN EXISTING FOUNDATION 2' BELOW PROPOSED GRADE. BACKFILL AND COMPACT ALL VOIDS PER SPECIAL PROVISIONS.
SALVAGE CITY OWNED POLE AND LUMINAIRE PER SPECIAL PROVISIONS.
0
10
FOR
EXISTING JUNCTION
BOX REMOVAL /MODIFICATION
CONSTRUCTION NOTES SEE SIGNAL PLANS.
13
SEE
WIRE SCHEDULE ON
SIGNAL PLANS FOR CONDUIT
CONTAINING SIGNAL WIRING.
C*T
N
H
w
w
x
CD
CD
Ln
a
w
z
J
x
WIRE NOTES
®RACEWAY
/I
CONDUIT 1
CONDUCTORS
COMMENTS
SIZE
1
2"
2 #8
SEE NOTES BELOW
2
I, 2"
4 #8
SEE NOTES BELOW
3
2"
6 #8
SEE NOTES BELOW
4
4"
SPARE - -
5
4"
_ 9 - - --
1 -96 SMFO
SEE NOTES BELOW
S
6
2"
_
SEE NOTES BELOW
7
EX.
SEE NOTES BELOW
8
I
4"
EX, 1 -48 SMFO
RE -ROUTE
NOTES:
1. ALL CONDUIT CONTAINING CONDUCTORS SHALL HAVE MIN 1 -#8
GROUND WIRE (UNLESS GROUND WIRE SIZE IS SPECIFIED IN THE WIRE
SCHEDULE OTHERWISE). SPARE CONDUIT SHALL CONTAIN BULL-LINE
TAPE AND LABELED "CITY OF RENTON ".
2. ALL SIGNAL AND LIGHTING CONDUIT SHALL BE RIGID PVC SCH 40,
EXCEPT UNDER ROADWAY USE RIGID PVC SCH 80. ALL FIBER CONDUIT
AND SPARE 4" CONDUIT SHALL BE RIGID PVC SCH 80 WITH FLEXIBLE
FABRIC INNERDUCT INSTALLED PER SPECIFICATIONS.
0 5 10 20 40 60
SCALE IN FEET
T- 3430116
BID
DOCUMENTS
ADDENDUM 02, REMOVED PRIVATE POLE REMOVAL NOTES JJA JF 12 -16 -11 _ t t -t a -t SURVEYED. KPG.. _-
P' p KPH RAINIER AVENUE S (SR 167) DRAWING NO. 236
o� WAS,, ti DRAWN BY: JIM CITY OF RENTON -
O
�P'. DESIGN BY: JF S GRADY WAY TO S 2ND ST PROJECT NO, gp40�g3o
FEHR & PEERS 753b Ave N 2502JeffmAve Pubic worts Deportment
FED AID NO. CM0167��481
CHECK BY: JF _ TRANSPORTATION CONSULTANTS Seattle, WA 99109 Tacoma, WA 98402 ILLUMINATION AND INTERCONNECT PLAN
",", ,.0 APPR V D FOR CONSTRUCTION
9' RFCSrra °O �Ea� PROJ MGR: TN a;.� o� -..e. (06)29fr1640 (253) 627 -0720 DATE: _NOV 2011
Sg G _ -- s um.e. wn www,kpg.COfll BY: DATF� SHEET NO. 236 OF 304_
NUMBER REVISION DESCRIPTION BY APP. DATE P TONALEN n FILE:0655DILL01.dwg '2�'' V644M //t STA 42 +00 TO STA 45 +00