Loading...
HomeMy WebLinkAboutT-3430190a v N N -o 0 0 L7 0 T 0 c� r ;.n 0 c 0 WE 0 0 ..1 U a 0 rn N w w x CD 0 cnr`7 i- w z J x WIRE SCHEDULE �p /so` /�, P1 \ P 0���/`� Q° GP �`G °POD y � G noel 01 2„ 1 2" 11 4 -- - — 2 2 1 3r 2 1 6 -I - - - - 4 3„ 3 - - - -' 6- 3 � -- 3" 1 - 2 !_2j - -- 5 3 �, 3 1 1 3 I 2' 11 3 3 4 4 12 I 2" 6 -5 2 4 . - -- 13 2 4 3 4 4 - -- - -- 7 4 4 - - — 3, 3 2 14 3' 8 2" 3 2 1 4 2 9 ..I! 3„ 1 1 15 4 2 3„ 10 2" 16 2" ! 2 11 3" 12 I 2" 2 . - -- 13 2 2 - 3, 3 4 4 4 14 3' 3„ 3 2 1 3" 2 2 2 1 1 15 3„ 4 16 2" ! 2 2„ 3 17 2" -- -� 6 18 2" 3 2" 6 19 2„ 2 20 21 22 2 3" 1 2 2 2 1 11 2 1 2 2 i 1 1 2 2 1 1 1 1 1 3_ 2 2 - 2 3 24 3" 1 2 2 1 _1_ 5 _ - ISPARE 2 2 " -. -1 27 2' 1 28 2 -3 " SPARE 29 2„ -- 2 — -- - i733U] �i. �71�ilvkr :"d21%00i�iLl:II�GII�RF�k11IO7. NU I tJ: 1. UNLESS OTHERWISE SPECIFIED, ALL PROPOSED SIGNAL AND FIBER OPTIC CONDUIT SHALL BE RIGID PVC SCH 80. 2. ALL TWISTED PAIRS ENTERING SIDEWALK SHALL BE INSTALLED IN 2" CONDUIT. 3. ALL PVC CONDUITS CONTAINING CONDUCTORS SHALL INCLUDE GROUND WIRE. GROUND WARE SIZE SHALL MATCH THE LARGEST CONDUCTOR (MIN #8 AWG OR AS NOTED OTHERWISE IN THE WIRE NOTES). SPARE /EMPTY CONDUIT SHALL BE LABELED "CITY OF RENTON" AND SHALL CONTAIN BULL—UNE TAPE. CONSTRUCTION NOTES Oj CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE WITH MAST AND LUMINAIRE ARMS. INSTALL FOUR VEHICLE SIGNAL HEADS, ONE TYPE 722 EMERGENCY PRE- EMPTION DETECTOR (PER CDR STD DWG J032), ONE TSP ANTENNA (TO BE FURNISHED AND INSTALLED BY OTHERS), ONE VEHICLE DETECTION CAMERA, TWO REGULATORY AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE ROADWAY DECORATIVE LUMINAIRE WITH PHOTOCELL (SEE LUMINAIRE SCHEDULE, ILLUMINATION SHEET 234) ON THE SIGNAL MAST ARM. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO PUSH BUTTON ASSEMBLIES (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS), ONE REGULATORY SIGN, AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEET 261, 262 AND SPECIAL PROVISIONS. Q2 CONSTRUCT FOUNDATION AND INSTALL TYPE II SIGNAL POLE WITH MAST ARM. INSTALL TWO VEHICLE SIGNAL HEADS, ONE TYPE 722 EMERGENCY PRE- EMPTION DETECTOR (PER COR STD DWG J032), ONE VEHICLE DETEC1ON CAMERA, ONE REGULATORY SIGN AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO PUSH BUTTON ASSEMBLIES (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS) AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEET 261, 262 AND SPECIAL PROVISIONS. Q3 CONSTRUCT FOUNDATION AND INSTALL TYPE III SIGNAL POLE WITH MAST AND LUMINAIRE ARMS. INSTALL FOUR VEHICLE SIGNAL HEADS, ONE VEHICLE DETECTION CAMERA, TWO REGULATORY AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL ONE ROADWAY DECORATIVE LUMINAIRE (SEE LUMINAIRE SCHEDULE, ILLUMINATION SHEET 234), ON THE SIGNAL MAST ARM. INSTALL ONE PEDESTRIAN SIGNAL HEAD, ONE PUSH BUTTON ASSEMBLY (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS) ONE PTZ CAMERA AND ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEET 261, 262 AND SPECIAL PROVISIONS. ® INSTALL FOUNDATION AND TYPE PS SIGNAL POLE PER CDR STD DWG J021. INSTALL ONE PEDESTRIAN SIGNAL HEAD AND ONE PUSH BUTTON ASSEMBLY (PER CDR STD DWGS J024 AND J025) ON THE POLE. FOR POLE AND FOUNDATION LOCATION SEE POLE SPECIFICATIONS SHEET 261, 262 AND SPECIAL PROVISIONS. O CONSTRUCT FOUNDATION AND INSTALL TYPE II SIGNAL POLE WITH MAST ARM. INSTALL TWO VEHICLE SIGNAL HEADS, ONE VEHICLE DETECTION CAMERA, ONE REGULATORY SIGN AND ONE STREET NAME SIGN ON THE MAST ARM. INSTALL TWO PEDESTRIAN SIGNAL HEADS, TWO PUSH BUTTON ASSEMBLIES (PER DETAIL, SHEET 264 AND SPECIAL PROVISIONS) ONE TERMINAL CABINET ON THE POLE. FOR POLE AND FOUNDATION LOCATION AND DETAILS SEE POLE SPECIFICATIONS SHEET 261, 262 AND SPECIAL PROVISIONS. © CONSTRUCT TRAFFIC CONTROLLER CABINET FOUNDATION PER CDR STD DWG J028 AND FURNISH AND INSTALL TYPE "P" CONTROLLER CABINET, CONTROLLER, ALL ASSOCIATED EQUIPMENT AND CONNECT FIELD WIRING. FOUNDATION TO BE LOCATED AT RAINIER AVENUE S, AT APPROXIMATE STA 34 +67, 59' RT. SEE SPECIAL PROVISIONS. O7 CONSTRUCT FOUNDATION AND FURNISH AND INSTALL ELECTRICAL SERVICE /BPS CABINET PER ILLUMINATION SHEETS. ® SEE ILLUMINATION PLANS FOR EXISTING LUMINAIRE POLE AND ASSOCIATED JUNCTION BOX REMOVAL NOTES. VIRTUAL VEHICLE DETECTION ZONE. SHOWN FOR REFERENCE ONLY. FINAL ZONE LOCATIONS SHALL BE DETERMINED BY THE ENGINEER IN THE FIELD. 10 FOLLOWING ACTIVATION OF NEW SIGNAL SYSTEM, INCLUDING VEHICLE DETECTION VIDEO SYSTEM, REMOVE EXISTING SIGNAL POLE AND ALL ASSOCIATED EQUIPMENT AND WIRING. GRIND DOWN EXISTING FOUNDATION 2 FEET BELOW PROPOSED GRADE AND BACKFILL AND COMPACT PER SPECIAL PROVISIONS. CAP AND ABANDON EXISTING CONDUIT. SALVAGE EXISTING EQUIPMENT AS DETERMINED BY THE ENGINEER IN FIELD AND PER SPECIAL PROVISIONS. 11 REMOVE EXISTING JUNCTION BOX AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. REMOVE EXISTING UNUSED WIRING AND CAP AND ABANDON EXISTING UNUSED CONDUIT. 12 FOLLOWING ACTIVATION OF NEW SIGNAL SYSTEM, REMOVE EXISTING SIGNAL CONTROLLER CABINET, SIDE MOUNTED ELECTRICAL SERVICE CABINET AND ALL ASSOCIATED EQUIPMENT /CONDUIT /WIRING (SALVAGE PER SPECIAL PROVISIONS). REMOVE FOUNDATION AND COMPACT AND BACKFILL VOID PER SPECIAL PROVISIONS. 13 ABANDON EXISTING VEHICLE DETECTION LOOPS AND REMOVE ASSOCIATED WIRING FROM STUBOUT TO CONTROLLER. 14 EXISTING LUMINAIRE TO REMAIN. SEE ILLUMINATION PLANS FOR WIRING /CONDUIT MODIFICATIONS. 15 INSTALL NEW VEHICLE DETECTION LOOP AS PER CDR STD DWG J038 AND J039. SEE SPECIAL PROVISIONS. i6 INSTALL ONE ADVANCED TYPE 711 EMERGENCY PRE- EMPTION DETECTOR ON PREFABRICATED 3/4" THREADED INSERT MOUNTED ON LUMINAIRE POLE (APPROX 20' MOUNTING HEIGHT). FOR LUMINAIRE POLE INSTALLATION DETAILS SEE ILLUMINATION PLANS. 17 CONSTRUCT FOUNDATION AND INSTALL 336A "RAPID RIDE" COMMUNICATION CABINET AS SHOWN IN THE RAPID RIDE CABINET DETAILS ON SHEET 263. CABINET AND ASSOCIATED EQUIPMENT TO BE PROVIDED BY OTHERS. COORDINATE CABINET DEUVERY WITH KING COUNTY METRO REPRESENTATIVE. 18 SEE ILLUMINATION SHEETS FOR CONTINUATION OF CONDUIT AND WIRING. REMOVE EXISTING JUNCTION BOX AND INSTALL NEW JUNCTION BOX PER PLANS. MAINTAIN CONNECTIONS TO EXISTING CONDUIT AND WIRING IN 19 BOX. COMPLETE NEW WIRING INSTALLATION PER WARE SCHEDULE ON THIS SHEET. ©0 INSTALL TYPE 25 -TA VAULT WITH FIBER SPLICE ENCLOSURE AND COIL 50 FEET OF EACH FIBER CABLE. SEE DETAILS ON SHEET 265. 21 APPROXIMATE PSE POWER SOURCE LOCATION, COORDINATE FINAL CONNECTION WITH PSE REPRESENTATIVE. -' /I O\ T=3430190 EXISTING TRAFFIC SIGNAL SHALL REMAIN FULLY OPERATIONAL UNTIL DAY OF CHANGEOVER WHEN UNIFORMED POLICE 6 SERVICE "s 7 L� , 2 OFFICER SHALL DIRECT TRAFFIC. 0 5 10 20 40 60 BID ENLARGED SIGNAL DETAIL SCALE IN FEET DOCUMENTS SCALE: 1" = 5' -0" 11 14-11 SURVEYED: KPG 25O P Fqs r ��� .0 RAINIER AVENUE S (SR 167) DRAWING NO. "AS,, DRAWN BY: JM CITY OF RENTON - - C�P` N 9 P . DESIGN BY: JF F E H R & PEERS 7539h Ave N 2502 Jefte son Ave Pub Wor<s Deportment S GRADY WAY TO S 2ND ST PROJECT NO. TED40_3430 o TRANSPORTATION CONSULTANTS Seale. Wp98109 Tacoma, WA 98402 SIGNALIZATION PLAN FED AID NO. CM0167(048) CHECK BY: JF ___ "- 4 Q' i 41'1 A.e . .L c u o m,.�u a (206129E1849 (Zj3) 67T -0%� APP D FOR CONSTRUCTION DATE: NOV 2011 LE PROJMGR: TN � Lt et RAINIER AVE S & S 4TH PLACE fSSI ONAL Ed - -- ,�i sib 2280 �, n � BY: DATE: / flle SHEET NO. 250 OF 304 NUMBER REVISION DESCRIPTION BY APP. DATE FILE: 0655DSIGOt.dwg 77 - - a a z m a j.�.j o d� i oa c W a .p o w N O a