HomeMy WebLinkAboutT-3430232�i
I�
0
N
3
a
Y
IRRIGATION SCHEDULE
SYMBOL
MANUFACTURER
MODEL NO.
DESCRIPTION
9
RAINBIRD
SURVEYED: KPG
DRAWN BY: EM
DESIGN BY: EM
CHECK BY: EG
PROJ MGR: JF
FILE: 0655DIRR01.dwg
BUBBLER SERIES -1402
FULL- CIRCLE FLOOD BUBBLER - INSTALL PER DETAIL SHEET 293.
RAINIER AVENUES (SR 167)
S GRADY WAY TO S 2ND ST
IRRIGATION SCHEDULE AND DETAILS
ES
RAINBIRD
1800 -15 STRIP SERIES
SHRUB HEAD - 6" PLASTIC POP -UP. 5'x15', 5'x30' AT 30 PSI. SIDE & END STRIP NOZZLE, INSTALL
ON FLEXIBLE RISER
EST SST
A 0
RAINBIRD
1800 -15 STRIP SERIES
LAWN HEAD - 6" PLASTIC POP -UP. 5'x15', 5'x30' AT 30 PSI. SIDE & END STRIP NOZZLE, INSTALL
ON FLEXIBLE RISER
VA
8H
RAINBIRD
8 SERIES MPR
SHRUB HEAD - 6" PLASTIC POP -UP. ADJ TO 8' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
8Q
e m m
RAINBIRD
REVISION DESCRIPTION
12 SERIES MPR
LAWN HEAD - 6" PLASTIC POP -UP. ADJ TO 12' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
DATE
120 12H 12F
1E�i a
RAINBIRD
12 SERIES MPR
SHRUB HEAD - 6" PLASTIC POP -UP. ADJ TO 12' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
t � C
RAINBIRD
15 SERIES MPR
SHRUB HEAD - 6" PLASTIC POP -UP. 15' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
15Q 15H 15F
U o @
RAINBIRD
15 SERIES MPR
LAWN HEAD - 6" PLASTIC POP -UP. 15' RADIUS AT 30 PSI. INSTALL ON FLEXIBLE RISER
15Q 15H 15F
SENTINEL SATILUTE
(2) 24- STATION OUTDOOR CONTROLLERS (A & B), STAINLESS STEEL PEDESTAL MOUNTED WITH CONCRETE
IR
TORO
A- SSAK24PS16NS1
FOUNDATION. SEE SIGNAL PLANS FOR ELECTRICAL SERVICE. PROVIDE 3 SPARE WIRES (RED) FROM
CONTROLLER
B- SSAK24PS16NS1
THROUGH EACH CONTROL VALVE BOX, TO FURTHEST VALVE BOX FROM CONTROLLER. PROVIDE TELEPHONE LINE TO
CONTROLLERS FOR TELEPHONE MODEM.
WEATHERMATIC
2100
AUTOMATIC CONTROL VALVE - SIZE AS NOTED ON PLAN.
POC -A
POINT OF
CONNECTION EQUIPMENT, APPROX. STA 26 +65, 50' RT. SEE DETAILS THIS SHEET AND SHEET 293.
X
FEBCO
850
1 1/2" DOUBLE CHECK VALVE.
Q
WEATHERMATIC
2100
1 1/2" MASTER SHUTOFF VALVE AND TORO TS FLOW SENSOR
QO
RAINBIRD
44 -LRC
1" BRASS QUICK COUPLER VALVE WITH LOCKING VINYL COVER. INSTALL PER DETAIL. INSTALL ONE AT
DOUBLE CHECK
VALVE ASSEMBLY.
1 1/2" IRRIGATION METER. SEE WATER PLANS FOR MORE INFORMATION.
POC -B
POINT OF
CONNECTION EQUIPMENT, APPROX.
STA 35 +82, 44' LT. SEE DETAILS THIS SHEET AND SHEET 293.
X
FEBCO
850
1 1/2" DOUBLE CHECK VALVE.
0
WEATHERMATIC
2100
1 1/2" MASTER SHUTOFF VALVE AND TORO TFS FLOW SENSOR
O
RAINBIRD
44 -LRC
1" BRASS QUICK COUPLER VALVE WITH LOCKING VINYL COVER. INSTALL PER DETAIL. INSTALL ONE AT
DOUBLE CHECK
VALVE ASSEMBLY.
M
1 1/2" IRRIGATION METER. SEE WATER PLANS FOR MORE INFORMATION.
- -
PVC SCH 40, IRRIGATION MAIN LINE - 24" MIN COVER
PVC SCH 40, LATERAL SUPPLY LINE- 18" MIN. COVER - SIZE AS NOTED.
- - -
- -
SLEEVING, PVC SCHEDULE 40, SIZE TWICE INSERT PIPE DIA.
iS 1F A
INDICATES VALVE & CONTROLLER # "A" OR "B" INDICATES CONTROLLER A OR B
10.5
INDICATES APPROX. GPM
"1S" INDICATES VALVES FOR STREETSCAPE PLANTER ZONES.
1"
INDICATES VALVE SIZE
"1F" INDICATES VALVES FOR FILTERRA /TREE GRATE ZONES.
IRRIGATION
MAIN LINE
DOUBLE CHECK VALVE
PRESSURE REDUCING VALVE
MASTER SHUT OFF VALVE AND FLOW SHUT OFF VALVE
INSTALL IN SEPARATE VALVE BOX
- IRRIGATION METER
N =H
1" QUICK COUPLER VALVE
TO PRESSURE MAIN
NOTE:
CONNECTION TO PRESSURE MAIN SHALL NOT BE
MADE UNTIL IRRIGATION MAIN LINE IS PRESSURE
TESTED.
TYPICAL POINT OF CONNECTION ASSEMBLY
NTS
c
c
LL
L
LL
(t
SIDE ELEVATION
POC VALVE BOX IRRIGATION GENERAL NOTES
1. COORDINATE INSTALLATION OF IRRIGATION SYSTEM WITH INSTALLATION OF OTHER
QUICK COUPLER UTILITIES, INCLUDING JOINT TRENCH AND FILTERRA UNITS. LOCATE AND PROTECT
(2) STAINLESS STEEL CLAMPS ALL UNDERGROUND UTILITIES DURING INSTALLATION OF IRRIGATION SYSTEM.
TO STAKE 2, IRRIGATION SYSTEM SHALL BE INSTALLED, TESTED, MAINTAINED AND GUARANTEED
P.V.C. NIPPLE
3' #4 REBAR STAKE AS PER SPECIFICATIONS.
3. IRRIGATION SYSTEM IS DESIGNED TO OPERATE FROM 30 PSI. CONTRACTOR SHALL
FIELD CHECK EXISTING WATER PRESSURE, ADJUSTING PRV AS NECESSARY TO
360' PVC TRIPLE SWING JOINT PROVIDE OPTIMUM PERFORMANCE.
P.V.C. PRESSURE MAIN 4. LOCATIONS OF IRRIGATION MAIN LINE, LATERALS, SLEEVING AND VALVES INDICATED
ON DRAWINGS ARE SCHEMATIC ONLY. ADJUST LOCATIONS AS NECESSARY. DO
PVC TEE OR ELBOW WITH NOT OVERSPRAY ONTO PAVED SURFACES.
THREADED OUTLET
5. IRRIGATION MAIN LINE LOCATION IS DIAGRAMMATIC. LINE SHALL BE PLACED IN
PLANTING AREAS WHERE EVER POSSIBLE.
6. MAIN LINE SHALL BE BURIED TO A DEPTH OF 24" BELOW FINISH GRADE. LATERAL
LINE FOR SPRAY ZONES SHALL BE BURIED TO A DEPTH OF 18" BELOW FINISH
QUICK COUPLER OR GRADE. LATERAL LINE FOR BUBBLER ZONES SHALL BE BURIED TO A DEPTH OF 12"
SPRINKLER BODY BELOW FINISH GRADE.
360' PVC TRIPLE SWING JOINT
PVC THREADED TEE AT 7• SLEEVE UNDER ALL PAVED SURFACES, CONCRETE SIDEWALK AND BETWEEN FILTERRA
MAINLINE UNITS AND SIDEWALK. SEE IRRIGATION PLANS FOR LOCATION OF PVC SLEEVING,
SLEEVING SHALL BE 2 TIMES THE DIAMETER OF THE INSERT PIPE AND WIRES.
SECTION THROUGH MAIN LINE
QUICK COUPLING VALVE/ TRIPLE SWING JOINT
NTS
NOTE:
ALL THE FITTINGS AND PIPE TO BE SAME DIA. AS
IPS FEMALE CONNECTION OF QUICK COUPLER/
SPRINKLER HEAD
INSTALL IN DCVA BOX
QUICK COUPLING VALVE,
SEE DETAIL THIS SHEET
PVC I COPPER BACK TO METER
8. CONTROLLER WIRES SHALL BE TAPED TOGETHER IN A BUNDLE AT 10' INTERVALS.
SNAKE WIRE IN BOTTOM OF PIPE TRENCH WHERE POSSIBLE. WHERE PIPE TRENCH IS
UNAVAILABLE WIRES SHALL BE PLACED IN SLEEVING. WIRES TO CONTROLLER SHALL
BE PLACED IN 1" / 1.5" SLEEVE, USE 3M DBY SPLICE KITS.
9. ALL EQUIPMENT SHALL BE AS SPECIFIED OR APPROVED EQUAL BY CITY OF RENTON.
SYSTEM IS SPECIFICALLY DESIGNED FOR IRRIGATION EQUIPMENT SHOWN ON PLANS
AND SUBSTITUTION WILL REQUIRE REDESIGN AND RECALCULATION OF IRRIGATION
ZONES.
10. NO GALVANIZED FITTINGS. ONLY BRASS OR SCH 40 PVC SHALL BE USED.
11. IRRIGATION TRENCHING NEAR ANY TREES TO REMAIN SHALL BE DONE WITH THE
MINIMUM AMOUNT OF DISTURBANCE POSSIBLE. TRIM AND CUT CLEAN ANY EXPOSED
OR DAMAGED ROOTS.
FINISH GRADE
ALL FITTINGS PVC
L- J
PVC IRRIGATION MAIN °
°OO , �O O °°o• °° °0 °OQ °.. o0 °O °°
°
°
_ °
0.
° .
STACKED METER BOXES PER CITY OF
RENTON STANDARDS. SIZE TO FIT
EQUIPMENT.
COMPACT BACKFILL
APPROVED DOUBLE CHECK VALVE, INSTALL
PER CITY OF RENTON STANDARDS.
COPPER UNION AND PIPE
PRESSURE REDUCING
VALVE
0
J
LL
II f 111 1 PRESSURE MAIN CONNECT
1�--� TO MASTER SHUT OFF
VALVE (INSTALLED IN
8" MIN DEPTH PEA SEPARATE BOX)
GRAVEL, WITH FILTER
FABRIC
INSTALL ASSEMBLY IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN - 340.8.
SEE POINT OF CONNECTION ASSEMBLY, THIS SHEET.
DETAIL DOUBLE CHECK VALVE ASSEMBLY
NTS
T- 3430232
a
z
m
a
j�•j
n /1I
O
ro
a �
o w
K
a .p
0
0 0
z
1
�j k -mow
va�iawa
Q 3�6
i
5
11 -14,11
o
a
aLL
w
SURVEYED: KPG
DRAWN BY: EM
DESIGN BY: EM
CHECK BY: EG
PROJ MGR: JF
FILE: 0655DIRR01.dwg
gp04k
BID
75391h AvenueN 2502 Jefferson AV¢0U¢
SeatOe, WA 98109 Tacoma, WA 98402 DOCUMENTS
(206128&1640 253621 -0720
( 1
www.kpg.00m
e. CITY OF RENTON
Public Works Depa tment
APP VED FOR CONSTRUCTION
;/ /
BY: DATE � /�L
RAINIER AVENUES (SR 167)
S GRADY WAY TO S 2ND ST
IRRIGATION SCHEDULE AND DETAILS
DRAWING NO. 292
PROJECTNO. TED403430
FED AID NO. - CM0167(046)
DATE: NOV 2011
SHEET NO. 292 OF 304
NUMBER
REVISION DESCRIPTION
BY
APP.
DATE
a
z
m
a
j�•j
n /1I
O
ro
a �
o w
K
a .p
0
0 0
z