HomeMy WebLinkAboutR-372406F ,vl DEMOLITION CONSTRUCTION NOTES: _ 1. CONCRETE FOUNDATIONS AND CONCRETE APRON AROUND THE BUILDING SHALL BE REMOVED. SEE ALSO ARCHITECTURAL r x 20 10 0 20 40 PLANS. 2. ALL UTILITY SERVICE LINES WITHIN NEW BUILDING FOOTPRINT SHALL BE REMOVED. DISCONNECT AND CAP ALL UTILITY SCALE — — 4 _! FEET SERVICES PRIOR TO BUILDING DEMOLITION. COORDINATE WITH UTILITY PURVEYORS. E IN 3 ARRANGE TO PURCHASE A CAP OFF PERMIT. A RECONNECT PERMIT IS ALSO REQUIRED. WATER AND SEWER DISTRICT AND _ PRIOR TO DEMOLISHING THE BUILDING, THE CONTRACTOR SHALL CONTACT SOOS CREEK W of —4 4. EXISTING SIDE SEWER IS NOT SHOWN ON SURVEY. CONTRACTOR TO ABANDON PER SOOS DISTRICT REQUIREMENTS. r 7 eusgnovr � ` I � 5. SEE ELECTRICAL AND MECHANICAL PLANS FOR POWER, LIGHTING, PHONE, AND COMMUNICATION DEMOLITION AND RELOCATION. — 5 9 — // 6. SEE MECHANICAL PLANS FOR GAS DEMOLITION AND RELOCATION. 10 v E�5 a . K. j I 7. DO NOT SHUT OFF OR CAP UTILITIES WITHOUT PRIOR NOTICE. COORDINATE WORK WITH LOCAL UTILITY PURVEYORS. a o 0 O`TOB "- / — -- S. VERIFY THAT ALL UTILITY SERVICES TO BE DEMOLISHED HAVE BEEN DISCONNECTED. a '- N - m p W W 9. ERECT BARRIERS, SHORING AND THE LIKE TO PROTECT PERSONNEL, CONSTRUCTION, ADJACENT PROPERTIES, AND VEGETATION w � TO REMAIN, COMPLY WITH ALL STATE AND LOCAL AGENCY REQUIREMENTS. y m 10. PROVIDE FOR THE PROTECTION OF PERSONS PASSING AROUND OR THROUGH THE AREA OF DEMOLITION. m a a i C INC s Z O J O w 0 m 0 eo N E m e m LL a x 0 IL 0 N � V1 l , 6 ���Aiiiv► Vii. ~J'���0 *i�i��v��s�i�iGi�it ����� @ ii °NvA�ii�iiiin►iyii�9.i.ii��1� ! a t& "A...�..• 4 400A ill WA I� `mss II E%II SIDS j',II III�_ P1150II /, ss PAR�ING SPACES i�AH/(ING SPA PARKING SPA m ., Y i ASPHAL T PA vIN0 n SITE DEMOLITION PLAN SCALE: 1 " = 20' W cn I ✓S SS ALr _PA Vim DEMO rc % % % SAWCUT Mr REMOVE [ CAP UTI REMOVE L L d REMOVE REMOVE XREMOVE 11. PROTECT FROM HARM ANY TREES, OR OTHER OBJECTS SELECTED TO REMAIN. 12. DO NOT DAMAGE EXISTING CONSTRUCTION TO REMAIN. 13. MAINTAIN VEHICULAR AND PEDESTRIAN TRAFFIC ROUTES: ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, SIDEWALKS, AND ADJACENT FACILITIES; DO NOT CLOSE OR OBSTRUCT STREETS, SIDEWALKS, OR PASSAGEWAYS WITHOUT PERMISSION FROM AUTHORITIES HAVING JURISDICTION; MAINTAIN FIRE ACCESS ALONG ACCESS ROAD AT ALL TIMES; MEET ALL APPLICABLE CODES AND ORDINANCES. 14. SPRINKLE DEBRIS AS NECESSARY TO LIMIT DUST TO LOWEST PRACTICABLE LEVEL. DO NOT SPRINKLE TO EXTENT CAUSING FLOODING, CONTAMINATED RUNOFF OR ICING. 15. REMOVE EXISTING ABOVE -GRADE AND BELOW -GRADE IMPROVEMENTS AS INDICATED AND AS NECESSARY TO FACILITATE NEW CONSTRUCTION. CARE SHALL BE TAKEN THAT DAMAGE DOES NOT OCCUR TO EXISTING PAVEMENT WHICH IS TO REMAIN IN PLACE AND THAT ALL PAVEMENT REMOVALS ARE ACCOMPLISHED BY MAKING A NEAT VERTICAL SAW CUT AT THE BOUNDARIES OF THE AREA TO BE REMOVED. 16. COMPLETELY REMOVE TREES, GROWTH AND UNDERBRUSH INCLUDING COMPLETE ROOT SYSTEMS AS REQUIRED FOR NEW CONSTRUCTION IN PLANTERS INDICATED FOR REMOVAL ONLY. REMOVAL OPERATIONS SHALL BE PERFORMED IN A MANNER TO PROTECT PROPERTY. 17. MAKE CUTS AT CLOSEST PAVING JOINT. LITTON LEGEND PAVEMENT UTILITY LINE LITY LINE BUILDING ASPHALT PAVEMENT CONCRETE PAVEMENT, STAIRS WITH RAILING ITEM DEMOLITION KEY NOTES: O ABANDON U PLUG OR CAP STORM DRAIN PIPE U PROTECT EXIST UTILITY VAULT O PROTECT EXIST TRAFFIC SIGN ® PROTECT EXIST PP O5 PROTECT EXIST CONCRETE RETAINING WALL I PROTECT EXIST SS MH O7 PROTECT EXIST CURB V cn I ✓S SS ALr _PA Vim DEMO rc % % % SAWCUT Mr REMOVE [ CAP UTI REMOVE L L d REMOVE REMOVE XREMOVE 11. PROTECT FROM HARM ANY TREES, OR OTHER OBJECTS SELECTED TO REMAIN. 12. DO NOT DAMAGE EXISTING CONSTRUCTION TO REMAIN. 13. MAINTAIN VEHICULAR AND PEDESTRIAN TRAFFIC ROUTES: ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, SIDEWALKS, AND ADJACENT FACILITIES; DO NOT CLOSE OR OBSTRUCT STREETS, SIDEWALKS, OR PASSAGEWAYS WITHOUT PERMISSION FROM AUTHORITIES HAVING JURISDICTION; MAINTAIN FIRE ACCESS ALONG ACCESS ROAD AT ALL TIMES; MEET ALL APPLICABLE CODES AND ORDINANCES. 14. SPRINKLE DEBRIS AS NECESSARY TO LIMIT DUST TO LOWEST PRACTICABLE LEVEL. DO NOT SPRINKLE TO EXTENT CAUSING FLOODING, CONTAMINATED RUNOFF OR ICING. 15. REMOVE EXISTING ABOVE -GRADE AND BELOW -GRADE IMPROVEMENTS AS INDICATED AND AS NECESSARY TO FACILITATE NEW CONSTRUCTION. CARE SHALL BE TAKEN THAT DAMAGE DOES NOT OCCUR TO EXISTING PAVEMENT WHICH IS TO REMAIN IN PLACE AND THAT ALL PAVEMENT REMOVALS ARE ACCOMPLISHED BY MAKING A NEAT VERTICAL SAW CUT AT THE BOUNDARIES OF THE AREA TO BE REMOVED. 16. COMPLETELY REMOVE TREES, GROWTH AND UNDERBRUSH INCLUDING COMPLETE ROOT SYSTEMS AS REQUIRED FOR NEW CONSTRUCTION IN PLANTERS INDICATED FOR REMOVAL ONLY. REMOVAL OPERATIONS SHALL BE PERFORMED IN A MANNER TO PROTECT PROPERTY. 17. MAKE CUTS AT CLOSEST PAVING JOINT. LITTON LEGEND PAVEMENT UTILITY LINE LITY LINE BUILDING ASPHALT PAVEMENT CONCRETE PAVEMENT, STAIRS WITH RAILING ITEM a a N N N N N M 10 n m "z L A ^r€ 3 G a <� E LL V � ° J w • r > = a Cm C-) z' J z O H O m i_u 0 i_u H : co WENDYS 10619 SE CARR ROAD R=372406 �oYS STORE NO. 10542 NEW RESTAURANT E2000- 2013 -UM -T1 ULTRA MODERN Abossein 4129/I+ Engineering, L. L. C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462 -9441 FAX: (425) 462 -9451 E -Moil: csermekbossencom www.abossein.corn 0 a IN COMPLIANCE WITH CITY OF RENTON STANDARDS BY: ,:7— DATE: f S•ASe BY: DATE: N PROTECT ITEM AS DESCRIBED BY KEY NOTE a BY: DATE: Call before you dig BY: DATE: E2000- 2013 -UM T1' 9 -12 -2013 JOB No. SHEET No. 213087 C3.0 I z °z °a a a 0 0 DEMOLITION KEY NOTES: O ABANDON AND PLUG OR CAP STORM DRAIN PIPE O2 PROTECT EXIST UTILITY VAULT O PROTECT EXIST TRAFFIC SIGN ® PROTECT EXIST PP O5 PROTECT EXIST CONCRETE RETAINING WALL © PROTECT EXIST SS MH O7 PROTECT EXIST CURB ® REMOVE EXIST ROCKERY IN ENTIRE LENGTH (NOT SHOWN ON SURVEY) O PROTECT EXIST TRANSFORMER 10 PROTECT EXIST WATER METER a a N N N N N M 10 n m "z L A ^r€ 3 G a <� E LL V � ° J w • r > = a Cm C-) z' J z O H O m i_u 0 i_u H : co WENDYS 10619 SE CARR ROAD R=372406 �oYS STORE NO. 10542 NEW RESTAURANT E2000- 2013 -UM -T1 ULTRA MODERN Abossein 4129/I+ Engineering, L. L. C. MECHANICAL - ELECTRICAL CIVIL - LEED FIRE PROTECTION 2100 112TH AVE. NE BELLEVUE, WA 98004 PH: (425) 462 -9441 FAX: (425) 462 -9451 E -Moil: csermekbossencom www.abossein.corn 0 a IN COMPLIANCE WITH CITY OF RENTON STANDARDS BY: ,:7— DATE: f S•ASe BY: DATE: N PROTECT ITEM AS DESCRIBED BY KEY NOTE a BY: DATE: Call before you dig BY: DATE: E2000- 2013 -UM T1' 9 -12 -2013 JOB No. SHEET No. 213087 C3.0 I z °z °a a a 0 0