DRIVEWAY TYPE
O DRIVEWAY DROP W/O LANDSCAPE STRIP — MATCH EX. DRIVEWAY WIDTH — 2 LOCATIONS
POUR BACK TO EX. CONCRETE DRIVEWAY
16' DRIVEWAY DROP W/LANDSCAPE STRIP — 6 LOCATIONS
I
16' DRIVEWAY DROP W/O LANDSCAPE STRIP — 3 LOCATIONS
FOUND CONCRETE MON
IN CASE' WITH
1 1/2" BRASS DISK AND PUNCH AT
INTERSECTION OF N.E.
14TH AND
MONTEREY AVE. N.E.
DOWN 0.6'
N 187048.36
E 1304459.92
EL 283.09
k\
N
812011
ST/A6. •/ 0+00
n
SAW CLFF EX.
ASPHALT ALONG
DRNIEWAY
10N,_
REMOVE EXCESS
ASPHALT
2+00
W
LLI IJ
— — — — — - -- — -
_T
>
INN
Ld
IN
NOTE:
@ADJUST TO FINAL GRADE
- q
\P\
00
R-200.0
RT. SIDE 0 PLAT
BOUNDARY
PORTION OF THE SW 1/4, SE 1/4 OF SECTION 5, TOWNSHIP 23 N, RANGE 5 EAST, W.M.
- 16
vd \
RIM 266.22
IE=263.12, 12"
\.O\
MONTEREY AVENUE NE
FOUND CONCRETE MON �INCASE_Wl
LEAD AT INTERSECTION OF N.E. 127
. N.E.
AVE
7
(CITY OF RENTON C.P.N. 71)
N 186463.1572
7
@ E 1304865.211
EL 284.63
vo 8/16/2011
? STA=0+00, AS-BUILT WATER PLANS
C) I x CITY OF RENTON, W-034201
_272
<
LLi
1u)
vd It I
------ -- AS-BUILT AS-BUILT
106U R, 12 N-12 CB#3, TYPE-1 ILLI, -1
_,�'CB#5, TYPE
WS—=4.67% THRU-CURB INLET
IE=258.20, 12" W/VANED GRATE
@ IE=258 N0 �21
E) RIM=260.60
IE=257.62, 12
@
@
2�I_F., 12" N-12
06=6.10%
MONTEREY AVENUE NE
Aq-RL4I11I
CB 41 TYPE -1L
V
RIM - 959.83 INT'X MONTEREY AVE NE NE 12th STREE T
2
E=256.2 1 STA. -5 +87.42
(MONTEREY)
IE=256.1 12" W STA.=4+55.94 (NE 12th)
INSTALL PUPLik 'SIGNS -0
th - --STREET"
AS-BUILT
-W
CB#7, INLET
RIM=255.62
1-Tr-N-12 05=5.28% IE=254.01, 8"D.I.
AS-BUILT
CB 6, TYPE-1 ADJUST TO FINAL GRADE
W S
0LID LOCKING LID INSTALL SOLID LOCKING LID
RIM=256.67
IE=253.86, 12-,(S) ;�E=2,57__60, 12"'W"
IE=253.93, 12 (E) E=25"S.51 8-( ""NEW
11LF., 12" N-12 CS=1.91% IE=253.65 , T�N) NEW
D.L. OFFE, P.E.
SCALE
1 AT
Fwm"
51'NE MGOId,•Y3y
NOTE,
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE
APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND
HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND
UTILIITES PRIOR TO COMMENCING CONSTRUCTION. NO
REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES
ARE SHOWN HEREON. THE ENGINEER ASSUMES NO
RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES
NOT SHOWN IN THEIR PROPER LOCATION.
CALL BEFORE YOU DIG, 1-800-424-5555
STORM WATER MANAGEMENT NOTES:
(1) FLOW CONTROL BMP'S CONSTRUCTED ON EACH LOT
SHALL BE OPERATED, MAINTAINED AND KEPT IN GOOD
REPAIR BY EACH LOT OWNER.
(2) FULL INFILTRATION FLOW CONTROL BMP'S WILL BE UTILIZED
FOR LOTS 1-9. BMP TO BE INSTALLED BY
BUILDER AS PART OF BUILDING PERMIT — UNDER SEPARATE
PERMIT.
** — FULL INFILTRATION FLOW CONTROL BMP'S ARE REQUIRED
UTILIZING SEVERAL OPTIONS SEE SHEET 5 FOR TWO OPTIONS.
SEE STORM WATER NOTES (2).
CITY OF
RENTON
DATUM
Plan ning/Building/Public Works Dept.
R=365207
GRAPHIC SCALE
0 15 30 60
1 inch = 50 feet
NELSON PLAT
SIGNATURE CUSTOM HOMES of WA, LLC
ROAD/STORM PLANS
AS-BUILT 04-20-2013
V)
P4
0
C-4
C',
3; M 0
u
rA 0
L A
Off" V_3C,5_�-07 I I I IRi❑
105/28/20121
1 �anmac I
4 _; 9
T