GENERAL SEWER AND DRAINAGE NOTES
1. THE CONTRACTOR SHALL VERIFY THE LOCATION AND ELEVATION OF THE
EXISTING SIDE SEWER OR SERVICE DRAIN AT THE POINT OF CONNECTION
PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY
THE AHJ INSPECTOR AND OWNER'S REPRESENTATIVE OF ANY
DISCREPANCIES.
2. UNLESS NOTED OTHERWISE ON PLANS, PIPE MATERIALS FOR SANITARY SIDE
5. BEDDING FOR PIPES AND STRUCTURES SHALL BE IN ACCORDANCE WITH
AHJ STANDARDS AND SPECIFICATIONS. BEDDING MATERIAL FOR PVC PIPE
SHALL BE MECHANICALLY COMPACTED TO 95% OF MAXIMUM DRY DENSITY
AS MEASURED BY ASTM D -698.
6. TEES ON NEW PIPE LESS THAN 24" DIAMETER SHALL BE PREFABRICATED.
TEES ON EXISTING PIPE OR ON NEW PIPE WITHOUT PREFABRICATED TEES
SHALL BE CONNECTED BY CORE DRILLING AND FLEXIBLE CONNECTION. SEE
SPECIFICATIONS.
7. TEES, CATCH BASIN CONNECTIONS, SIDE SEWERS, AND SERVICE DRAINS
SHALL BE PLACED AT A MINIMUM SLOPE OF 2% AND A MAXIMUM SLOPE
OF 50% UNLESS OTHERWISE INDICATED ON THE PLANS.
8. SERVICE DRAINS AND SIDE SEWERS SHALL BE CONNECTED OR
RECONNECTED AS APPROVED BY THE AHJ INSPECTOR.
9. RELAY EXISTING SERVICE DRAINS AND SIDE SEWERS TO CLEAR OVER OR
UNDER THE NEW UTILITY AS APPROVED BY THE AHJ INSPECTOR.
10. WHERE A NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS,
POLYETHYLENE PLASTIC FOAM SHALL BE PLACED AS A CUSHION BETWEEN
THE UTILITIES.
11. PROVIDE DUCTILE IRON PIPE SLEEVE WHERE SS, SSS, OR SD PASSES
UNDERNEATH OR THROUGH ANY FOOTINGS, STEM WALLS, RETAINING WALLS,
OR ROCKERIES.
12. A SEPARATE SEWER /DRAINAGE SIDE SEWER PERMIT FROM THE AHJ IS
REQUIRED. AT THE TIME OF APPLYING FOR THIS PROJECT'S SIDE SEWER
PERMIT THE APPROVED AHJ PLAN COVER SHEET AND DRAINAGE CONTROL
PLAN SET MUST BE PRESENTED WITH PERMIT APPLICATION.
13. PROVIDE FITTINGS, AS REQUIRED, TO CONNECT TO EXISTING UTILITIES IN
RIGHT -OF -WAY.
14. PROVIDE SWEEPING TEES OR WYES AT ALL PIPE TO PIPE CONNECTION
LOCATIONS.
15. ADJUST RIM ELEVATION OF CATCH BASINS, AREA DRAINS AND CLEANOUT
CASTINGS TO MATCH SURROUNDING GRADES, UNLESS OTHERWISE NOTED.
16. COORDINATE CONNECTION OF SANITARY SIDE SEWER WITH MECHANICAL
PLANS. PROVIDE FITTINGS AS REQUIRED TO MAKE CONNECTION.
1
�/Tn tS
PORTION OF: SE 1/4 & NE 1/4 OF THE SW 1/4, SECTION 04, T. 23 N., R. 05 E., W.M.
STORM DRAINAGE NOTES
1. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE
APPROVED DRAINAGE CONTROL PLAN IN THE APPROVED BUILDING PERMIT
PLAN SET, WHICH IS ON FILE WITH THE AHJ. ANY DEVIATION FROM THE
APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE AHJ AND
THE OWNER'S REPRESENTATIVE.
2. A COPY OF THE APPROVED DRAINAGE CONTROL PLANS MUST BE ON THE
JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
3. ALL REQUIRED STORM WATER FACILITIES MUST BE CONSTRUCTED AND IN
OPERATION PRIOR TO CONSTRUCTION OF IMPERVIOUS SURFACING UNLESS
OTHERWISE APPROVED BY THE AHJ AND THE OWNER'S REPRESENTATIVE.
4. CONNECT ALL ROCKERY, WALL, AND BUILDING FOOTING DRAINS TO THE
STORM SYSTEM AT A CATCH BASIN UNLESS OTHERWISE NOTED.
5. PROVIDE FOOTING DRAIN CLEANOUTS AT A MAXIMUM 100' ON CENTER AND
PROVIDE NO FEWER THAN TWO PER STRUCTURE. COORDINATE LOCATION
WITH THE OWNER'S ARCHITECT AND ENGINEER. CONTRACTOR SHALL
DOCUMENT AS -BUILT LOCATION OF INSTALLED CLEANOUTS ON
CONTRACTOR'S AS- BUILTS. MAINTAIN AS- BUILTS AS WORK PROGRESSES.
6. ROOF DOWNSPOUT TIGHTLINES CONVEYING STORMWATER FROM ONE
DOWNSPOUT SHALL BE OF 4 -INCH DIAMETER PVC STORM DRAIN. ROOF
DOWNSPOUT TIGHTLINES CONVEYING STORMWATER FROM TWO OR MORE
DOWNSPOUTS SHALL BE OF 6 -INCH DIAMETER PVC STORM DRAIN.
7. TYPE 1 AND TYPE 2 CATCH BASIN STRUCTURES PER THE CITY OF RENTON
STANDARD PLANS AND SPECIFICATIONS.
8. PROVIDE A MINIMUM OF 2.0% SLOPE ON ALL DRAINAGE AND DOWNSPOUT
CONNECTION LINES, UNLESS NOTED OTHERWISE.
9. PROVIDE STORM DRAIN STENCILING IN PAVEMENT AT ALL STORM DRAIN
CATCH BASINS, INLETS AND AREA DRAINS THAT ARE IN OR WITHIN ONE
FOOT OF A PAVED AREA. STENCILING SHALL BE IN ACCORDANCE WITH
PUBLIC AGENCY STANDARDS.
INFILTRATION AND LID FACILITIES PROTECTION NOTES
1. REDIRECT SHEET FLOW, BLOCK DRAIN INLETS AND /OR CURB OPENINGS IN
PAVEMENT AND INSTALL FLOW DIVERSION MEASURES TO PREVENT
CONSTRUCTION SILT LADEN WATER AND DEBRIS FROM ENTERING
EXCAVATIONS AND FINISH SURFACES FOR BIORETENTION FACILITIES AND
POROUS PAVEMENTS.
2. WHERE AMENDED SOILS, BIORETENTION FACILITIES, POROUS PAVEMENTS,
AND OTHER INFILTRATION FACILITIES ARE INSTALLED, THESE AREAS MUST BE
PROTECTED AT ALL TIMES FROM BEING OVER COMPACTED. IF AREAS
BECOME COMPACTED, REMEDIATE AND TILL SOIL IN ACCORDANCE WITH
OWNER'S GEOTECHNICAL ENGINEER REPRESENTATIVE REQUIREMENTS AT NO
ADDITIONAL COST TO OWNER IN ORDER TO RESTORE INFILTRATION.
3. INSTALL FLOW DIVERSION MEASURES OUTSIDE OF THE CRITICAL ROOT ZONE
OF TREES TO BE PROTECTED. AT NO TIME SHALL CONSTRUCTION
STORMWATER BE DIRECTED TO TREES TO BE PROTECTED. CONSTRUCTION
STORMWATER SHALL NOT POND WITHIN A TREE'S CRITICAL ROOT ZONE.
WATER SERVICE NOTES
1. ALL MATERIALS FOR WATER DISTRIBUTION SHALL BE NEW.
2. APPLY FOR AND PAY ALL FEES ASSOCIATED WITH OBTAINING NEW WATER
SERVICES. COORDINATE WITH CITY OF RENTON.
3. ALL WATER SERVICE PIPING ON PRIVATE PROPERTY MUST BE INSPECTED BY
CITY OF RENTON PRIOR TO BACKFILLING TRENCH.
4. COORDINATE CONNECTION OF FIRE AND WATER SERVICES WITH
ARCHITECTURAL PLANS. PROVIDE FITTINGS AS REQUIRED TO MAKE
CONNECTIONS.
5. FIRE SERVICE SIZING SHOWN ON PLAN FOR DISTRIBUTION LINE IS
PRELIMINARY. CONTRACTOR'S FIRE SPRINKLER DESIGNER TO DETERMINE
SIZING DISTRIBUTION FOR MAXIMUM FLOW. HORIZONTAL ALIGNMENT OF FIRE
SPRINKLER PIPING SHALL BE AS SHOWN ON PLAN.
NPDES /ECOLOGY PERMIT NOTES
1. THE CONTRACTOR SHALL APPLY FOR THE NATIONAL POLLUTANT DISCHARGE
ELIMINATION SYSTEM AND STATE WASTE DISCHARGE GENERAL PERMIT FOR
STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY
(NPDES PERMIT) THROUGH WASHINGTON STATE DEPARTMENT OF ECOLOGY.
2. THE CONTRACTOR SHALL SUBMIT A NOTICE OF INTENT TO COMPLY WITH
ECOLOGY'S BMP'S IN ACCORDANCE WITH NPDES PERMIT. THE CONTRACTOR
SHALL ALSO PUBLISH A NOTICE ON TWO SEPARATE DAYS IN THE
NEWSPAPER WHICH HAS GENERAL CIRCULATION IN THE COUNTY IN WHICH
THE CONSTRUCTION IS TO TAKE PLACE. THE NOTICE MUST ANNOUNCE THAT
THE PROJECT IS SEEKING COVERAGE UNDER ECOLOGY'S GENERAL PERMIT.
PRE - CONSTRUCTION MEETING
PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL SCHEDULE
AND ATTEND A PRE - CONSTRUCTION CONFERENCE WITH THE CITY OF RENTON.
THE CONTRACTOR SHALL NOTIFY THE OWNER AND THE OWNER'S PROFESSIONAL
ENGINEERING CONSULTANTS OF THE PRE - CONSTRUCTION MEETING TIME AND
LOCATION. IF A PRE - CONSTRUCTION MEETING IS NOT REQUIRED, A FIRST
GROUND DISTURBANCE MEETING WITH THE OWNER AND CONSULTANT DESIGN
TEAM IS REQUIRED PRIOR TO ANY CONSTRUCTION ACTIVITY.
HORIZONTAL AND VERTICAL CONTROL NOTES*
*PROVIDED BY BENCHMARK SURVEYING LLC
HORIZONTAL DATUM:
NAD 1983/91 UTILIZING CITY OR RENTON MONUMENTS NO. 58 AND 1843 ON NE
12TH ST.
VERTICAL DATUM:
NAVD 88 PER CITY OF RENTON CONTROL NETWORK
CONTROLLING BENCHMARK: CITY OF RENTON MONUMENT NO. 57:
3" BRASS DISC W/ "X" IN CASE AT INT. OF NE 12TH ST. & EDMONDS AVE. NE.
ELEVATION = 326.43' (99.496 METERS)+
BENCHMARKS:
SITE BENCHMARK NO. 1: FOUND & ACCEPTED PK NAIL AT THE INTERSECTION OF
KIRKLAND AVE. NE & NE 15TH ST. ELEVATION = 376.12
SITE BENCHMARK NO. 2: FOUND & ACCEPTED PK NAIL AT THE INTERSECTION OF
KIRKLAND AVE. NE & NE 16TH ST. ELEVATION = 379.91
ELECTRONIC INFORMATION TRANSFER AGREEMENT (EITA)
AN AUTOCAD ®2010 FILE (IN 2D) WILL BE PROVIDED TO THE CONTRACTOR FOR
HORIZONTAL LAYOUT OF CIVIL UTILITIES (STORM. SEWER. AND WATER). GRADING
CONTOURS. STRIPING. LANDSCAPING. AND SPOT ELEVATIONS AND /OR PAVING
(WALKS. DRIVES. CURBS) SHOWN ON PLAN VIEW OF THESE SHEETS. PRIOR TO
RELEASE OF AUTOCAD FILE, CONTRACTOR WILL BE REQUIRED TO SIGN AN
ELECTRONIC INFORMATION TRANSFER AGREEMENT (EITA) FORM FROM SvR
DESIGN COMPANY. PLEASE NOTIFY PROJECT CONTACT AT SvR DESIGN COMPANY
AT (206) 223 -0326 FOR A COPY OF THE EITA FORM.
SEWER (SSS) AND SERVICE DRAIN (SD) SHALL BE PVC PIPE
AND FITTINGS
6 Date: 0 13
PER ASTM D3034, SDR35 WITH RUBBER GASKET JOINTS.
Date:
a
3. DUCTILE IRON PIPE SHALL BE PER ANSI A21.51 CLASS 50 WITH PUSH -ON
z
JOINTS. FITTINGS FOR DUCTILE IRON PIPE SHALL BE DUCTILE
PER ANSI
A21.10 OR ANSI A21.53 WITH PUSH -ON JOINTS. GLANDS ON
MECHANICAL
JOINT PIPE AND FITTINGS SHALL BE DUCTILE.
0
o=
0
4. PIPES WITH LESS THAN 18" COVER SHALL BE DUCTILE IRON
PIPE. ROOF
DOWNSPOUT TIGHTLINES AND BUILDING FOOTING DRAINS ARE
EXCEPTIONS
TO THIS REQUIREMENT AND MAY HAVE A MINIMUM OF 12 INCHES OF
COVER UNLESS NOTED OTHERWISE ON PLANS.
5. BEDDING FOR PIPES AND STRUCTURES SHALL BE IN ACCORDANCE WITH
AHJ STANDARDS AND SPECIFICATIONS. BEDDING MATERIAL FOR PVC PIPE
SHALL BE MECHANICALLY COMPACTED TO 95% OF MAXIMUM DRY DENSITY
AS MEASURED BY ASTM D -698.
6. TEES ON NEW PIPE LESS THAN 24" DIAMETER SHALL BE PREFABRICATED.
TEES ON EXISTING PIPE OR ON NEW PIPE WITHOUT PREFABRICATED TEES
SHALL BE CONNECTED BY CORE DRILLING AND FLEXIBLE CONNECTION. SEE
SPECIFICATIONS.
7. TEES, CATCH BASIN CONNECTIONS, SIDE SEWERS, AND SERVICE DRAINS
SHALL BE PLACED AT A MINIMUM SLOPE OF 2% AND A MAXIMUM SLOPE
OF 50% UNLESS OTHERWISE INDICATED ON THE PLANS.
8. SERVICE DRAINS AND SIDE SEWERS SHALL BE CONNECTED OR
RECONNECTED AS APPROVED BY THE AHJ INSPECTOR.
9. RELAY EXISTING SERVICE DRAINS AND SIDE SEWERS TO CLEAR OVER OR
UNDER THE NEW UTILITY AS APPROVED BY THE AHJ INSPECTOR.
10. WHERE A NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS,
POLYETHYLENE PLASTIC FOAM SHALL BE PLACED AS A CUSHION BETWEEN
THE UTILITIES.
11. PROVIDE DUCTILE IRON PIPE SLEEVE WHERE SS, SSS, OR SD PASSES
UNDERNEATH OR THROUGH ANY FOOTINGS, STEM WALLS, RETAINING WALLS,
OR ROCKERIES.
12. A SEPARATE SEWER /DRAINAGE SIDE SEWER PERMIT FROM THE AHJ IS
REQUIRED. AT THE TIME OF APPLYING FOR THIS PROJECT'S SIDE SEWER
PERMIT THE APPROVED AHJ PLAN COVER SHEET AND DRAINAGE CONTROL
PLAN SET MUST BE PRESENTED WITH PERMIT APPLICATION.
13. PROVIDE FITTINGS, AS REQUIRED, TO CONNECT TO EXISTING UTILITIES IN
RIGHT -OF -WAY.
14. PROVIDE SWEEPING TEES OR WYES AT ALL PIPE TO PIPE CONNECTION
LOCATIONS.
15. ADJUST RIM ELEVATION OF CATCH BASINS, AREA DRAINS AND CLEANOUT
CASTINGS TO MATCH SURROUNDING GRADES, UNLESS OTHERWISE NOTED.
16. COORDINATE CONNECTION OF SANITARY SIDE SEWER WITH MECHANICAL
PLANS. PROVIDE FITTINGS AS REQUIRED TO MAKE CONNECTION.
1
�/Tn tS
PORTION OF: SE 1/4 & NE 1/4 OF THE SW 1/4, SECTION 04, T. 23 N., R. 05 E., W.M.
STORM DRAINAGE NOTES
1. THE STORM DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE
APPROVED DRAINAGE CONTROL PLAN IN THE APPROVED BUILDING PERMIT
PLAN SET, WHICH IS ON FILE WITH THE AHJ. ANY DEVIATION FROM THE
APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE AHJ AND
THE OWNER'S REPRESENTATIVE.
2. A COPY OF THE APPROVED DRAINAGE CONTROL PLANS MUST BE ON THE
JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
3. ALL REQUIRED STORM WATER FACILITIES MUST BE CONSTRUCTED AND IN
OPERATION PRIOR TO CONSTRUCTION OF IMPERVIOUS SURFACING UNLESS
OTHERWISE APPROVED BY THE AHJ AND THE OWNER'S REPRESENTATIVE.
4. CONNECT ALL ROCKERY, WALL, AND BUILDING FOOTING DRAINS TO THE
STORM SYSTEM AT A CATCH BASIN UNLESS OTHERWISE NOTED.
5. PROVIDE FOOTING DRAIN CLEANOUTS AT A MAXIMUM 100' ON CENTER AND
PROVIDE NO FEWER THAN TWO PER STRUCTURE. COORDINATE LOCATION
WITH THE OWNER'S ARCHITECT AND ENGINEER. CONTRACTOR SHALL
DOCUMENT AS -BUILT LOCATION OF INSTALLED CLEANOUTS ON
CONTRACTOR'S AS- BUILTS. MAINTAIN AS- BUILTS AS WORK PROGRESSES.
6. ROOF DOWNSPOUT TIGHTLINES CONVEYING STORMWATER FROM ONE
DOWNSPOUT SHALL BE OF 4 -INCH DIAMETER PVC STORM DRAIN. ROOF
DOWNSPOUT TIGHTLINES CONVEYING STORMWATER FROM TWO OR MORE
DOWNSPOUTS SHALL BE OF 6 -INCH DIAMETER PVC STORM DRAIN.
7. TYPE 1 AND TYPE 2 CATCH BASIN STRUCTURES PER THE CITY OF RENTON
STANDARD PLANS AND SPECIFICATIONS.
8. PROVIDE A MINIMUM OF 2.0% SLOPE ON ALL DRAINAGE AND DOWNSPOUT
CONNECTION LINES, UNLESS NOTED OTHERWISE.
9. PROVIDE STORM DRAIN STENCILING IN PAVEMENT AT ALL STORM DRAIN
CATCH BASINS, INLETS AND AREA DRAINS THAT ARE IN OR WITHIN ONE
FOOT OF A PAVED AREA. STENCILING SHALL BE IN ACCORDANCE WITH
PUBLIC AGENCY STANDARDS.
INFILTRATION AND LID FACILITIES PROTECTION NOTES
1. REDIRECT SHEET FLOW, BLOCK DRAIN INLETS AND /OR CURB OPENINGS IN
PAVEMENT AND INSTALL FLOW DIVERSION MEASURES TO PREVENT
CONSTRUCTION SILT LADEN WATER AND DEBRIS FROM ENTERING
EXCAVATIONS AND FINISH SURFACES FOR BIORETENTION FACILITIES AND
POROUS PAVEMENTS.
2. WHERE AMENDED SOILS, BIORETENTION FACILITIES, POROUS PAVEMENTS,
AND OTHER INFILTRATION FACILITIES ARE INSTALLED, THESE AREAS MUST BE
PROTECTED AT ALL TIMES FROM BEING OVER COMPACTED. IF AREAS
BECOME COMPACTED, REMEDIATE AND TILL SOIL IN ACCORDANCE WITH
OWNER'S GEOTECHNICAL ENGINEER REPRESENTATIVE REQUIREMENTS AT NO
ADDITIONAL COST TO OWNER IN ORDER TO RESTORE INFILTRATION.
3. INSTALL FLOW DIVERSION MEASURES OUTSIDE OF THE CRITICAL ROOT ZONE
OF TREES TO BE PROTECTED. AT NO TIME SHALL CONSTRUCTION
STORMWATER BE DIRECTED TO TREES TO BE PROTECTED. CONSTRUCTION
STORMWATER SHALL NOT POND WITHIN A TREE'S CRITICAL ROOT ZONE.
WATER SERVICE NOTES
1. ALL MATERIALS FOR WATER DISTRIBUTION SHALL BE NEW.
2. APPLY FOR AND PAY ALL FEES ASSOCIATED WITH OBTAINING NEW WATER
SERVICES. COORDINATE WITH CITY OF RENTON.
3. ALL WATER SERVICE PIPING ON PRIVATE PROPERTY MUST BE INSPECTED BY
CITY OF RENTON PRIOR TO BACKFILLING TRENCH.
4. COORDINATE CONNECTION OF FIRE AND WATER SERVICES WITH
ARCHITECTURAL PLANS. PROVIDE FITTINGS AS REQUIRED TO MAKE
CONNECTIONS.
5. FIRE SERVICE SIZING SHOWN ON PLAN FOR DISTRIBUTION LINE IS
PRELIMINARY. CONTRACTOR'S FIRE SPRINKLER DESIGNER TO DETERMINE
SIZING DISTRIBUTION FOR MAXIMUM FLOW. HORIZONTAL ALIGNMENT OF FIRE
SPRINKLER PIPING SHALL BE AS SHOWN ON PLAN.
NPDES /ECOLOGY PERMIT NOTES
1. THE CONTRACTOR SHALL APPLY FOR THE NATIONAL POLLUTANT DISCHARGE
ELIMINATION SYSTEM AND STATE WASTE DISCHARGE GENERAL PERMIT FOR
STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY
(NPDES PERMIT) THROUGH WASHINGTON STATE DEPARTMENT OF ECOLOGY.
2. THE CONTRACTOR SHALL SUBMIT A NOTICE OF INTENT TO COMPLY WITH
ECOLOGY'S BMP'S IN ACCORDANCE WITH NPDES PERMIT. THE CONTRACTOR
SHALL ALSO PUBLISH A NOTICE ON TWO SEPARATE DAYS IN THE
NEWSPAPER WHICH HAS GENERAL CIRCULATION IN THE COUNTY IN WHICH
THE CONSTRUCTION IS TO TAKE PLACE. THE NOTICE MUST ANNOUNCE THAT
THE PROJECT IS SEEKING COVERAGE UNDER ECOLOGY'S GENERAL PERMIT.
PRE - CONSTRUCTION MEETING
PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL SCHEDULE
AND ATTEND A PRE - CONSTRUCTION CONFERENCE WITH THE CITY OF RENTON.
THE CONTRACTOR SHALL NOTIFY THE OWNER AND THE OWNER'S PROFESSIONAL
ENGINEERING CONSULTANTS OF THE PRE - CONSTRUCTION MEETING TIME AND
LOCATION. IF A PRE - CONSTRUCTION MEETING IS NOT REQUIRED, A FIRST
GROUND DISTURBANCE MEETING WITH THE OWNER AND CONSULTANT DESIGN
TEAM IS REQUIRED PRIOR TO ANY CONSTRUCTION ACTIVITY.
HORIZONTAL AND VERTICAL CONTROL NOTES*
*PROVIDED BY BENCHMARK SURVEYING LLC
HORIZONTAL DATUM:
NAD 1983/91 UTILIZING CITY OR RENTON MONUMENTS NO. 58 AND 1843 ON NE
12TH ST.
VERTICAL DATUM:
NAVD 88 PER CITY OF RENTON CONTROL NETWORK
CONTROLLING BENCHMARK: CITY OF RENTON MONUMENT NO. 57:
3" BRASS DISC W/ "X" IN CASE AT INT. OF NE 12TH ST. & EDMONDS AVE. NE.
ELEVATION = 326.43' (99.496 METERS)+
BENCHMARKS:
SITE BENCHMARK NO. 1: FOUND & ACCEPTED PK NAIL AT THE INTERSECTION OF
KIRKLAND AVE. NE & NE 15TH ST. ELEVATION = 376.12
SITE BENCHMARK NO. 2: FOUND & ACCEPTED PK NAIL AT THE INTERSECTION OF
KIRKLAND AVE. NE & NE 16TH ST. ELEVATION = 379.91
ELECTRONIC INFORMATION TRANSFER AGREEMENT (EITA)
AN AUTOCAD ®2010 FILE (IN 2D) WILL BE PROVIDED TO THE CONTRACTOR FOR
HORIZONTAL LAYOUT OF CIVIL UTILITIES (STORM. SEWER. AND WATER). GRADING
CONTOURS. STRIPING. LANDSCAPING. AND SPOT ELEVATIONS AND /OR PAVING
(WALKS. DRIVES. CURBS) SHOWN ON PLAN VIEW OF THESE SHEETS. PRIOR TO
RELEASE OF AUTOCAD FILE, CONTRACTOR WILL BE REQUIRED TO SIGN AN
ELECTRONIC INFORMATION TRANSFER AGREEMENT (EITA) FORM FROM SvR
DESIGN COMPANY. PLEASE NOTIFY PROJECT CONTACT AT SvR DESIGN COMPANY
AT (206) 223 -0326 FOR A COPY OF THE EITA FORM.
R=370603
PLEASE king Day 811
BEFORE YOU DIG
PERMIT CORRECTIONS 7/11/1
E PERMIT CORRECTIONS 9 30 1 BENCHMARK AS NOTED rm loea Q, RHA KIRKLAND AVENUE
DESIGN COMPANYD 1C
PERMIT CORRECTIONS 10/23/13 RM CITY OF TOWNHOMES
1105 SECOND AVE. SUITE 200 RENTON
dz RENTON, WA 98056
SEATTLE. WA 98101 ars Eta DATUM
aEa x e Planning /Building /Public Works Dept. 20.223.0326
P 20.223.0125 pB NOTES
wwwsvrdesigu.cOm NO. REVISION BY DATE APPR srA�.m �"'c'KC0R0M'r //pp ,Q q C.� / SECT
VA' ?�75G/�=5
T
U
w
cr
CC
O
Lu
31.2
CITY OF RENTON
Approved by: 6
6 Date: 0 13
Approved by: D
Date:
Approved by: D
Date:
Approved by: D
Date: 3
PLEASE king Day 811
BEFORE YOU DIG
PERMIT CORRECTIONS 7/11/1
E PERMIT CORRECTIONS 9 30 1 BENCHMARK AS NOTED rm loea Q, RHA KIRKLAND AVENUE
DESIGN COMPANYD 1C
PERMIT CORRECTIONS 10/23/13 RM CITY OF TOWNHOMES
1105 SECOND AVE. SUITE 200 RENTON
dz RENTON, WA 98056
SEATTLE. WA 98101 ars Eta DATUM
aEa x e Planning /Building /Public Works Dept. 20.223.0326
P 20.223.0125 pB NOTES
wwwsvrdesigu.cOm NO. REVISION BY DATE APPR srA�.m �"'c'KC0R0M'r //pp ,Q q C.� / SECT
VA' ?�75G/�=5
T
U
w
cr
CC
O
Lu
31.2