HomeMy WebLinkAboutS-353602a w J LL GENERAL NOTES: 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE STARTING WORK AND SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY DISCREPANCIES. 2. UNLESS DETAILED, SPECIFIED, OR OTHERWISE INDICATED ON THE DRAWINGS, CONSTRUCTION SHALL BE AS INDICATED IN THE APPLICABLE TYPICAL DETAILS AND GENERAL NOTES. TYPICAL DETAILS SHALL APPLY EVEN THOUGH NOT REFERENCED AT SPECIFIC LOCATIONS ON DRAWINGS. 3. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. ABBREVIATIONS AB ANCHOR BOLT ABC AGGREGATE BASE COURSE AC ASPHALTIC CONCRETE AFF ABOVE FINISHED FLOOR AHR ANCHOR ALM ALARM AL ALUMINUM APPROX APPROXIMATE ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS AUTO AUTOMATIC AVG AVERAGE @ AT BCV BALL CHECK VALVE BSP BLACK STEEL PIPE BV BALL VALVE CA CONCRETE ANCHOR CB CATCH BASIN CHNL CHANNEL CJ CONSTRUCTION JOINT CLOR CENTERLINE CUP CONTROL PANEL CND CONDUIT CO CLEANOUT COMP COMPACTED CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUE (D) (OUS) OR CONTROL CP CONTROL POINT CPLG COUPLING D DRAIN, DEPTH DEG DEGREE DET DETAIL DIA OR DIAMETER DIM DIMENSION DIP DUCTILE IRON PIPE DWG DRAWING E EAST EA EACH EL OR ELEV ELEVATION ELEC ELECTRIC (AL) EMBED EMBEDMENT ENGR ENGINEER EDP EDGE OF PAVEMENT EQL EQUAL EQPT EQUIPMENT EXIST EXISTING FUG FLANGE FRP FIBERGLASS REINFORCED PLASTIC FT FOOT, FEET GP GRINDER PUMP ID INSIDE DIAMETER OR INSIDE DIMENSION IE INVERT ELEVATION INVT INVERT L LENGTH LF LINEAR FEET MAX MAXIMUM MDD MAXIMUM DRY DENSITY MECH MECHANICAL MFRS MANUFACTURER'S MH MANHOLE, SANITARY MIN MINIMUM MISC MISCELLANEOUS N NORTH NE NORTHEAST NO NUMBER NOM NOMINAL NTS NOT TO SCALE OD OUTSIDE DIAMETER PD PUMPED DRAINAGE PL PROPERTY LINE PIMP PUMP PNL PANEL PSI POUND PER SQUARE INCH PV PLUG VALVE PVC POLYVINYL CHLORIDE PVMT PAVEMENT i�lac7 \�73_V7llby RDCR REDUCER REF REFERENCE REINF REINFORCE (D) (ING) (MENT) READ REQUIRED 5 SEWAGE OR SOUTH SCH SCHEDULE SCV SWING CHECK VALVE SD STORM DRAIN SIM SIMILAR SP SUMPPUMP SPEC SPECIFICATION SS SANITARY SEWER, GRAVITY SSFM SANITARY SEWER FORCE MAIN SSMH SANITARY SEWER MANHOLE SST STAINLESS STEEL STA STATION STD STANDARD STL STEEL S/W SIDEWALK TDH TOTAL DYNAMIC HEAD TOC TOP OF CONCRETE TYP TYPICAL VERT VERTICAL VOL VOLUME W WEST, WIDTH W/ WITH W/O WITHOUT SURVEY LEGEND (EXISTING LINE WORK) I>" WATER VALVE -�'�- HYDRANT FIRE DEPT. CONNECTION WATER METER 0 POST INDICATOR VALVE S MANHOLES (SS /SD) CB _0- POWER/UTILITY POLE GUY ANCHOR JUNCTION BOX �] POWER TRANSFORMER % ) POWERITELEPHONE VAULT POWER METER s. TELEPHONE/TV RISER 7, GAS VALVE GAS METER (; - -� STREET LIGHT X SPOT ELEVATION SIGN MAILBOX ROCKERY �u- CONIFEROUSTREE DECIDUOUS TREE 8'C W. COTTONWOOD iCV IRRIGATION CONTROL VALVE E MONUMENT NOT TIED THIS SURVEY FOUND CASED MONUMENT '.°. SET PK NAIL/ALUMINUM WASHER STAMPED "PACE CONTROL" SET 5/8" IRON REBAR W/ YELLOW O PLASTIC CAP STAMPED L.S. #33130 UNLESS OTHERWISE STATED. CENTER LINES PROPERTY LINES - RIGHT -OF -WAY LINES EASEMENT LINES LOT LINES DITCH LINE -- WATER LINE SANITARY SEWER LINE - ss STORM DRAIN LINE -- GAS LINE —c UNDERGROUND POWER LINES? UNDERGROUND TELEPHONE LINES - - - - -�* UNDERGROUND CABLE TV LINES ury OVERHEAD UTILITY LINES ar, CHAIN LINK FENCE c - -- a - -- WIREFENCE x - . - - - -x WOOD FENCE MECHANICAL LINE WORK NEW OR EXISTING STRUCTURES NEW OR EXISTING STRUCTURES HIDDEN NEW PIPING (TRIPLE LINES) NEW PIPING HIDDEN (TRIPLE LINES) NEW PIPING (SINGLE LINE) NEW PIPING HIDDEN (SINGLE LINE) EXISTING PIPING (TRIPLE LINES) EXISTING PIPING HIDDEN (TRIPLE LINES) EXISTING PIPING (SINGLE LINE) EXISTING PIPING HIDDEN (SINGLE LINE) NEW EQUIPMENT OR PIPING CENTERLINE EXISTING EQUIPMENT OR PIPING CENTERLINE NEW EQUIPMENT NEW EQUIPMENT HIDDEN EXISTING EQUIPMENT NEW FITTING EXISTING TO BE REMOVED NEW PIPING CALL -OUT 3 -PW BUILDING MATERIALS EXISTING PIPING CALL -OUT PbV VIEW IN SECTION MATERIAL EXISTING REMOVE NEW CLASS "A ", "B ",AND .: 1, '� ,rf; MECHANICAL SYMBOLS "D" CONCRETE A O CLASS "C" CONCRETE SWING CHECK VALVE STEEL 7i`�� II�II PLUG VALVE CAST IRON OR /y/ FLANGE FIBERGLASS -�/ _(j X11 ALUMINUM y�y�/° ' /, '/ UNION SOIL 90' ELBOW ��� 7? 45° ELBOW VIEW IN PLAN (NEW SHOWN - EXISTING SCREENED) GRATING SPA PAVEMENT RESTRAINED FLEXIBLE COUPLING II CROSS BALL VALVE U CAP BALL VALVE BALL CHECK VALVE RESTRAINED FLANGE COUPLING ADAPTER DRAWING CROSS REFERENCE DETAIL OR SECTION N IDENTIFICATION DETAIL OR SECTION TAKEN ON THE SAME SHEET AT TITLE DETAIL OR SECTION IS TAKEN ON THE DRAWING INDICATED TYPICAL DETAIL REFERENCE BUBBLE TYPICAL DETAIL NUMBER IDENTIFICATION DETAIL OR SECTION IDENTIFICATION DETAIL OR SECTION REFERENCE BUBBLE DETAIL OR SECTION IS TO BE FOUND ON THE SAME SHEET DETAIL OR SECTION IS TO BE FOUND ON THE DRAWING INDICATED TYPICAL DETAIL IS TO BE FOUND ON THE TYPICAL DETAIL DRAWINGS AT CROSS REFERENCE DESIGN CRITERIA HYDRAULIC REQUIREMENTS PUMP TYPE NUMBER OF PUMPS RATED CAPACITY, EACH PUMP MOTOR HORSEPOWER, EACH PUMP FORCE MAIN GRINDER 2 (1 -DUTY, 1- STANDBY) 30 GPM @ 34 FT TDH 2.0 3 INCH, PVC 5- 353602