HomeMy WebLinkAboutS-353606wW ELECTRICAL PLAN SYMBOLS ELECTRICAL ONE -LINE SYMBOLS IDENTIFICATION SYMBOLS SWITCHES /RECEPTACLES RACEWAY MEDIUM VOLTAGE LOW VOLTAGE MISCELLANEOUS e LOW VOLTAGE CIRCUIT BREAKER MOTOR a CIRCUIT BREAKER, MEDIUM VOLTAGE b p a = TYPE HP HP = HORSEPOWER RATING ® a S b SINGLE POLE SWITCH EXPOSED CONDUIT 62 a = CIRCUIT BREAKER NUMBER c 1 a MCP= MOTOR CIRCUIT PROTECTOR EQUIPMENT IDENTIFICATION a = DEVICE SWITCHED DESIGNATION b b = FRAME SIZE d O/ TM = THERMAL MAGNETIC FULL LOAD AMPS AS NOTED If b = CIRCUIT DESIGNATION _� A— INDICATES BREAK IN CONDUIT RUN b = FRAME SIZE (MANUFACTURER TO DETERMINE a PACKAGED EQUIPMENT a S b IF c = a b a =ANSI DEVICE FUNCTION ANSI RELAY DEVICE FRAME SIZE UNLESS INDICATED) ❑ LOAD RATING AS INDICATED O 2 = DOUBLE POLE SWITCH c c = NUMBER OF POLES b a = NUMERIC VALUE O d = TRIP SETTING (AT = AMP TRIP) b = HP, KW, KVA AS INDICATED INSTRUMENT IDENTIFICATION 3 = THREE -WAY SWITCH EXPOSED CONDUIT HIDDEN BEHIND WALLS, b= QUANTITY (AC= MCP CONTINUOUS SETTING) 4 = FOUR -WAY SWITCH FLOORS OR OTHER STRUCTURES e = DESIGNATION K = KEY OPERATED SWITCH ❑ f = INTERRUPTING RATING I a TRANSFORMER F = SWITCH AND FUSESTAT HOLDER _ MEDIUM VOLTAGE — ll .11_ b a = DEVICE I.D. EQUIPMENT /INSTRUMENT LOCATOR P = SWITCH AND PILOT LIGHT UNDERGROUND CONDUIT, DIRECT BURIED DISCONNECT SWITCH c b = KVA RATING T = THERMOSTAT NON -FUSED CUT OUT d OR IN DUCTBANK c = NUMBER OF PHASES O� D = DIMMER SWITCH LOW VOLTAGE CIRCUIT BREAKER e d = PRIMARY VOLTAGE a LUMINAIRE IDENTIFICATION O AUXILIARY OPERATOR e = SECONDARY VOLTAGE p OX b L = LOW VOLTAGE LIGHT SWITCH a = DEVICE SWITCHED FROM M = MANUAL MOTOR STARTER — CONDUIT IN FLOOR SLAB X = S = SHUNT TRIP ° b = CIRCUIT DESIGNATION MEDIUM VOLTAGE = K= KIRK KEY INTERLOCK c = MOUNTING HEIGHT IN FEET TO BOTTOM a d DISCONNECTING FUSE = G= GROUND FAULT INTERRUPTER GROUNDED WYE CONNECTION OF FIXTURE Q OCCUPANCY SENSOR FLEXIBLE CABLE OR CONDUIT SINGLE FUSE CUT OUT = V = SOLENOID KEY RELEASE b a = CIRCUIT DESIGNATION a CONDUIT IDENTIFICATION b = DEVICE SWITCHED DESIGNATION Q DELTA CONNECTION 0 XXXX= CONDUIT NUMBER, ❑ a DISCONNECT SWTICH O REFER TO CONDUIT SCHEDULE SWITCH AND SINGLE RECEPTACLE Sb a = CIRCUIT DESIGNATION '0 CONDUIT VERTICAL CHANGE IN DIRECTION MEDIUM VOLTAGE / a =TYPE, REFER TO DISCONNECT SCHEDULE INDICATES KEYNOTE 1 b = DEVICE TYPE DESIGNATION DISCONNECTING FUSE O C ENGINE - GENERATOR RATINGS AS O (PERTAINS ONLY TO SHEET WHERE NOTE IS FOUND S = SWITCH AND SINGLE RECEPTACLE DOUBLE FUSE CUT OUT I— —1 b INDICATED ON THE DRAWINGS a = KVA/KW Q JUNCTION BOX a a QQQ I� d b= VOLTAGE/CONNECTION �b DUPLEX RECEPTACLE ICI c =PHASE O OPERATOR INTERFACE STATION ILb-II MEDIUM VOLTAGE SINGLE FUSE 1 = STATION TYPE a = DEVICE CIRCUIT DESIGNATION � CONDUIT SEAL �p� d = WIRE b= DEVICE TYPE DESIGNATION FUSED DISCONNECT SWITCH a =pf ��pq,a a = TYPE, REFER TO DISCONNECT SCHEDULE EQUIPMENT ENCLOSURE -`q QUADRUPLEX RECEPTACLE b = FUSE RATING b a SPECIAL PURPOSE RECEPTACLE a = CIRCUIT DESIGNATION DUCTBANK b = DEVICE TYPE DESIGNATION APPROXIMATE DIMENSIONS MEDIUM VOLTAGE DOUBLE FUSE I n b ® DRAWINGS INDICATED ON THE GROUNDING a SHOWN ON DUCTBANK SCHEDULE I O a =AMPS ®b IN FLOOR DUPLEX RECEPTACLE L d b = VOLTAGE/CONNECTION a = CIRCUIT DESIGNATION c =PHASE UNLDEGROUNDGROUND GRID #410 SDBC b= DEVICE TYPE DESIGNATION CONDUIT SIZE AND CONDUCTORS MEDIUM VOLTAGE FUSE ® d =WIRE S OTHERWISE a ♦ LIVE FRONT TERMINATOR O GROUND ROD ®b IN FLOOR QUADRUPLEX RECEPTACLE ® a= CIRCUIT DESIGNATION INDIVIDUAL CONDUCTORS aE[ CURRENT TRANSFORMER WITH GROUND ROD AND GROUND WELL b = DEVICE TYPE DESIGNATION MEDIUM VOLTAGE ELBOW b SHORTING TERMINAL BLOCK W "C -(3 -X TYPE (0), 1-#Y TYPE (N) & 1 -Z TYPE (G)) a = QUANTITY �— COMPRESSION OR EXOTHERMIC �a A b = RATIO DUPLEX RECEPTACLE w /SPLIT WIRE GROUNDING CONNECTION b a = CIRCUIT DESIGNATION W "C (WHERE INDICATED): W = CONDUIT TRADE SIZE b= DEVICE TYPE DESIGNATION > MEDIUMVOL7AGET C 3 -X TYPE (0): POTENTIAL TRANSFORMER 3 = QUANTITY a = QUANTITY me b WELDING OR APPLIANCE RECEPTACLE X = SIZE OF CONDUCTORS A SST TRIP UNIT STATE b b = RATIO LUMINAIRES a= CIRCUIT DESIGNATION TYPE = INSULATION TYPE b = DEVICE TYPE DESIGNATION (0) = DESIGNATES PHASE CONDUCTORS a MEDIUM VOLTAGE CONTACTOR SSM SOLID STATE ® 2', 4', OR 8' FLUORESCENT STRIP WELDING RECEPTACLE 1 -Y TYPE (N)(= QUANTITY INDICATED): b a = CIRCUIT DESIGNATION 1 = QUANTITY /1 MULTIFUNCTION METER b = DISCONNECT TYPE Y = SIZE OF CONDUCTORS 'OOOII` COMBINATION STARTER F-1 2' X 2' LAY -IN TROFFER a TYPE = D INSULATION ULNAE TYPE \ WITH CONTROL BR AKER DISCONNECT, T, REFER TO LUMINAIRE SCHEDULE -� b SPECIAL PURPOSE RECEPTACLE (N) DESIGNATES NEUTRAL CONDUCTORS MEDIUM VOLTAGE STARTER /1 a a = CIRCUIT BREAKER DISCONNECT, ATP�1 a = CIRCUIT DESIGNATION TYPE T NOTED ✓ 3 AMMETER TEST POINT b = DEVICE TYPE DESIGNATION 1 -Z TYPE (G)(WHERE INDICATED): b = STARTER TYPE ) 7 = b c = NEMA STARTER SIZE 2' X 4' l TO L TROFFER ^ 1 QUANTITY c d = OVERLOAD HEATERS REFER TO LUMINAIRE SCHEDULE v CLOCK RECEPTACLE Z SIZE A CONDUCTORS �P a a = MOUNTING HEIGHT TYPE = INSULATION TYPE — 2- 0­1 MOV-EUBOW ARRESTOR > VOLTAGE TEST POINT (G) = DESIGNATES GROUND CONDUCTORS _ n -u FAN RECEPTACLE d o-O LUMINAIRE POLE MOUNTED a a = MOUNTING HEIGHT U {3 -X TYPE (0) & 1 -X TYPE (G)) U = NUMBER OF PARALLEL RUNS O KIRK KEY INTERLOCK O O TWIST LOCK RECEPTACLE I UTILITY METER U�� I STROBE a a =AMP RATING 000\I !"` a = COLOR - -RED a MULTI CONDUCTOR CABLES I / d VARIABLE FREQUENCY DRIVE G = GREEN Q TELEPHONE OUTLET b K/2 /C #16S i WITH FEATURES AS NOTED A =AMBER a = MOUNTING HEIGHT K (WHERE INDICATED) = NUMBER OF PAIRS I a = INPUT CONTACTOR a DATA COMMUNICATIONS OUTLET a 21C#16S = TWO CONDUCTOR, 16 GAUGE, TWISTED b = OUTPUT CONTACTOR b SHIELDED PAIR c c= BYPASS STARTER LUMINAIRE, EMERGENCY BATTERY- POWERED a = MOUNTING HEIGHT d =INPUT CIRCUIT BREAKER 0-0 O] LIGHTNING ARRESTER DISCONNECT SWTICH W3 /C #K(WHERE INDICATED)= NUMBER OF TRIPLETS I VFD LR LINE REACTOR LUMINAIRE, EMERGENCY /EXIT BATTERY- POWERED a = TYPE, REFER TO DISCONNECT SCHEDULE 3/C#16S = THREE CONDUCTOR, 16 GAUGE, TWISTED SHIELDED TRIPLETS I LL LL LOAD REACTOR PE PHOTOCELL I b �D LUMINAIRE, EMERGENCY BATTERY- POWERED REMOTE N /CX TYPE _ NSS TRANSIENT VOLTAGE d N NUMBER OF CONDUCTORS IN THE CABLE I — — — SMOKE DETECTOR X = SIZE OF CONDUTORS L J SURGE SUPRESSOR OLUMINAIRE, SURFACE OR PENDANT MOUNTED Oa a = TYPE TYPE = INSULATION TYPE I = IONIZATION r P = PHOTOELECTRIC I j- IC J1 'Lf` Jl LUMINAIRE, WALL MOUNTED d =DUCT DETECTOR FIBER OPTIC CABLES LUMINAIRE, DUAL FLOOD /SPOT, WITH MOTION SENSOR FACP FIRE ALARM CONTROL PANEL FO /N I RVSS REDUCED VOLTAGE SOLID STATE STARTER ( -I DRAWOUT CONNECTIONS 3 N = NUMBER OF INDIVIDUAL FIBERS IC =INPUT CONTACTOR �F FIRE ALARM PULL STATION I BC BC = BYPASS CONTACTOR =� GROUND E F �� ® LUMINAIRE, EXIT ONE OR TWO FACES AS INDICATED. 01 FIRE ALARM HORN /STROBE COMBINATION E ARROW POINTS IN DIRECTION OF EGRESS. I_ YY FIRE ALARM STROBE I T CAPACITOR OF FIRE SF RI LOW SWITCH I I— BATTERY LUMINAIRE, WALL WASHER T= TAMPER SWITCH S=353606 L J DMP I DIGITAL METERING PACKAGE OYDo W,Ni 9 PACE ENGINEERS, INC. NONE CITY OF WESTVIEW LIFT STATION �OCT2010 F. ALO '��'� UPGRADE ;�° �, 488'!8 o aL R E N TO N 0 Ecrs reRE DATUM Plannin /Buildin /Public Works N3fONAL E1ZG «enPCK Fxox� . Dept. 9 9 p SYMBOLS LEGEND GE -01 In,ls'� /o NO, REVISION BY DATE APPR ^P°"BRM swencwrowa.�6 a.9