HomeMy WebLinkAboutS-362133w
z
U
w
0
o:
o_
�I
J
O
U)
0
r_
r
w
m
J
T
w
U)
a
z
O
Z
w
x
w
Ir
>w
w
Q
z
Q
Q
J
w
0
Fr
w
LEGEND
! G
0
SANITARY SEWER CLEANOUT
EXISTING
PROPOSED
ROADWAY
s
—�
ROADWAY CENTERUNE
a+
----- ----�-
PROPERTY / LOT LINE
A
A
RIGHT -OF -WAYBOUNDARY
4
LINE
LINE
M
M
EASEMENT LINE
- — —
— — -
BUILDING SETBACK LINE
- -- ------- - ----- -----
- - - - -. -. _.....
ROLLED CURB AND GUTTER
A
- — — -
VERTICAL CURB AND GUTTER
t
t
CONTOUR (MINOR)
-- - - -- - --
-- ail --
CONTOUR (MAJOR)
- -- 820 - --
--
FOOTING DRAIN FLOWPATH
.�--
i-►
SPOT ELEVATION
x
T
TOP/TOE OF SLOPE
.J 1 - ---- j_.
-------- 1_- _ -_J -.
CONCRETE SIDEWALK
f...........;r...:.....s::3
0
CONCRETE BLOCK WALL
ROCKERY
0
BARRICADE
;..
PAD MOUNTED TRANSFORMER
BOLLARDS
.
.
MAILBOX
I:
o
DOWNSPOUTS
o
0
STORK DRAINAGE
CATCH BASIN TYPE 1 W /GRATE
s
CATCH BASIN TYPE 1 W /SOLID LID
X
SIGNAL JUNCTION BOX
CATCH BASIN TYPE 2 W /GRATE
C
SANITARY SEWER STUB MARKER POST
CATCH BASIN TYPE 2 W /SOLID LID
C
STORM DRAIN MANHOLE
OO C,
_
BEEHIVE MANHOLE
+
YARD DRAIN (ROUND LID)
0
TRAFFIC SIGNAL POLE W /UGHT
YARD DRAIN
STORM DRAIN STUB MARKER POST
STORM DRAIN CLEAN -OUT
_
STORM DRAIN PIPE
D
-
ROOF DRAIN
------ ------ - - - - --
�-
SO SERVICE 6' CPEP WITH
FIBER OPTIC STUB MARKER POST
INVERT O END OF PIPE
_ o
CATCH BASIN
SANITARY SEWER MANHOLE
! G
0
SANITARY SEWER CLEANOUT
0 ocs
0
SANITARY SEWER GRAVITY
s
—�
SANITARY SEWER FORCE MAIN
a+
----- ----�-
TRAFFIC
STRAIGHT /RIGHT TURN ARROW
A
A
STRAIGHT /RIGHT TURN ARROW
4
LEFT /RIGHT TURN ARROW
M
M
STRAIGHT /LEFT /RIGHT TURN ARROW
DEBRIS PILE
+
LEFT TURN ARROW
h
..
RIGHT TURN ARROW
A
POWER POLE W /LIGHT
STRAIGHT ARROW
t
t
HANDICAP PARKING
&
&
BIKE LANE
coo
TRAFFIC SIGN
.�--
i-►
INFORMATION SIGN
T
T
STREET LIGHT
t
�}E
CONSTRUCTION SEQUENCE:
1. THE CONTRACTOR SHALL COMPLETE THE INSTALLATION OF THE
SANITARY SEWER UNES WITHIN ONLY ONE ROADWAY BLOCK AT A
TIME AND SHALL COMPLETE THE TEMPORARY HOT -MIX ASPHALT
RESTORATION OF EACH ROADWAY BLOCK BEFORE BEGINNING
WORK IN ANOTHER BLOCK.
2. TEMPORARY RESTORATION OF TRENCHES FOR OVERNIGHT USE
SHALL BE ACCOMPLISHED BY USING HOT -MIX ASPHALT (HMA).
STEEL PLATES MAY BE USED OVERNIGHT TO COVER THE LAST
SECTION OF TRENCH. STEEL PLATES MUST BE PINNED DOWN
AND ASPHALT RAMPS /WEDGES MUST BE PLACED ROUND THE
PLATES. STEEL PLATES SHALL NOT BE USED ON STEEP GRADES
OR WHERE STEEL PLATES PRESENT A ROADWAY HAZARD.
{i`iil;Ceffvr-5l 1142:
Qi - WETLAND WITH BUFFER
T.E.S.C.P.
— — — CLEARING LIMITS
—x— FILTER FABRIC FENCE
CUTOFF SWALE
- INTERCEPTOR DITCH
-- - - -�-- N.G.P.E. FENCE
® J OBM A.u. S. up EERS LLC
WOO 205
WARNING: FWcraiWay,WA98009 I ®I ®ICI
THE UTILITY LOCATIONS SHOWN www•esmcivil.com
Girl Erpi,s,Lp I Pnject Ya�iwgsmnt I LaM,copaMM1ilaturc
ARE APPROXIMATE ONLY. DEPTH
UNKNOWN. CALL 1- 800 - 424 -5555. ESM JOB #1352- 020 -011
fs
0
0
ROCK CHECK DAM
SEDIMENT FILTER
STRAW BALE
GRAVEL CONE
RIP RR PAD
CONSTRUCTION ENTRANCE
3
No.
STREAM WITH BUFFER
SURVEY
09 PROPOSED MONUMENT IN CASE
® FOUND MONUMENT IN CASE
@am PROPOSED MONUMENT (AS DEFINED)
®am FOUND MONUMENT (AS DEFINED)
A DELTA
(R) RADIAL BEARING < >
(NR) NON- RADIAL BEARING
L RC LENGTH
ABBREVIATIONS GENERAL NOTES:
1. ALL WORK MATERIAL SHALL BE IN CONFORM
WITH THE
AVE AVENUE ID INSIDE DIAMETER LATEST STANDARDS AND SPECIFICATIONS OF THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT AND THE 2008 EDITION OF
AC ASBESTOS CEMENT PIPE IE INVERT ELEVATION THE WSDOT /APWA STANDARDS AND SPECIFICATIONS, AS
APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE
ADJ ADJACENT IN INCHES RENTON STANDARD PLANS & SPECIFICATIONS. SOME STANDARD
ALUM ALUMINUM DETAIL DRAWINGS MAY HAVE BEEN MODIFIED FOR THE CONTRACT.
L LENGTH THE CONTRACTOR SHALL REFER TO DETAIL DRAWINGS INCLUDED
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE LB POUNDS IN THE CONTRACT DOCUMENTS. A SET OF APPROVED PLANS
SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
R ANGLE POINT LF LINEAL FEET
2. ALL LOCATIONS OF EXISTING UTILITIES SHOWN RE APPROXIMATE
ASPH ASPHALT MAX MAXIMUM AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY
ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS MFR MANUFACTURER THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
DISTURBANCE. FOR UTILITY LOCATES CALL 800- 424 -5555 (OR
ASSY ASSEMBLY MH MANHOLE 811) A MINIMUM OF 72 HOURS PRIOR TO EXCAVATION.
BF BLIND FLANGE MIN MINIMUM 3. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE
BLDG BUILDING MJ MECHANICAL JOINT SUBMITTED AT THE PRE — CONSTRUCTION MEETING. ANY
MODIFICATIONS TO THE APPROVED TRAFFIC CONTROL PLAN SHALL
BILK BLOCK MISC MISCELLANEOUS BE RESUBMITTED AND APPROVED PRIOR TO IMPLEMENTATION.
80 BLOW OFF N NORTH 4. ALL FITTINGS SHALL BE BLOCKED PER CITY OF RENTON
BOW /BW BOTTOM OF WALL NO NUMBER STANDARD DETAILS UNLESS OTHERWISE NOTED.
BVC BEGIN VERTICAL CURVE 5. THE CONTRACTOR SHALL USE A VACUUM STREET SWEEPER TO
NITS NOT TO SCALE REMOVE DUST AND DEBRIS FROM PAVEMENT AREA AS DIRECTED
BW BACK OF WALK OC ON CENTER BY THE ENGINEER. FLUSHING OF STREETS SHALL NOT BE
PERMITTED.
CTR CENTER OD OUTSIDE DIAMETER
CB CATCH BASIN 6. BEFORE COMMENCEMENT OF TRENCHING, THE CONTRACTOR
OHW ORDINARY HIGH WATER SHALL PROVIDE A CATCH BASIN FILTER FOR ALL DOWNHILL
CI CAST IRON STORM DRAIN INLETS AND CATCH BASINS. THE CONTRACTOR
PI POINT OF INTERSECTION SHALL PERIODICALLY INSPECT THE CONDITION OF ALL FILTERS
CL /(� CENTERLINE PP POWER POLE AND REPLACE AS NECESSARY.
CLR CLEAR PVT POINT OF VERTICAL INTERSECTION 7. PAVEMENT MARKINGS (E.G. LANE LINE BUTTONS OR PAINT, STOP
CMP CORRUGATED METAL PIPE BARS, CROSSWALKS, ETC.) DAMAGED OR REMOVED DURING
PE POLYETHYLENE CONSTRUCTION SHALL BE REPLACED IN KIND.
CO CLEANOUT PERF PERFORATED
CONIC CONCRETE PVC POLYVINYL CHLORIDE
C CONDUIT PVMT PAVEMENT
CONN CONNECTION PVT POINT OF VERTICAL TANGENCY
CONTR CONTRACTOR PC POINT OF CURVATURE
CONT CONTINUED PT POINT OF TANGENCY NOTE:
CY CUBIC YARDS OTT• QUANTITY
1. LOT LINES ARE BASED ON CIS INFORMATION AND RE FOR
CL CLASS ABET RETAINING ONLY.
2• GRAVITY SANITARY SEWER PIPE MATERIAL:
CF CUBIC FEET RR RAILROAD PVC SDR35 - 4' TO 15' OF COVER
PVC C900 - LESS THAN 4' OF COVER
CPS CUBIC FEET PER SECOND
R RADIUS . PVC C900 - OVER 15' OF COVER
DC DEGREE OF CURVATURE RED REDUCER • PVC C905 - PIPE DIA. GREATER THAN 18" WITH LESS THAN
DI DUCTILE IRON REINF REINFORCED 4' OF COVER OR GREATER THAN 15' OF COVER
DIA /0 DIAMETER REQ REQUIRED
DOT DEPARTMENT OF TRANSPORTATION R/W RIGHT OF WAY
DIM DIMENSION S SOUTH SURVEY DATUM:
DWGS DRAWINGS SCH SCHEDULE HORIZONTAL DATUM:
D DRAIN SO STORM DRAIN NAD83(91) WASHINGTON STATE PLANE COORDINATE SYSTEM NORTH
EOP EDGE OF PAVEMENT SF SQUARE FEET ZONE
E EAST SHT SHEET VERTICAL DATUM:
NAVD 1988 CITY OF RENTON PUBLISHED BENCH MARKS
ELEV ELEVATION SPECS SPECIFICATIONS #1909 CASED MONUMENT WITH LEAD AND TACK AT THE INTERSECTION
EL ELEVATION SO SQUARE OF SE 139th PLACE AND 156TH AVENUE SE.
ELEC ELECTRICAL ELEVATION = 408.64
SS SANITARY SEWER
EVC END VERTICAL CURVE STA STATION #2088 CASE MONUMENT WITH %" BRASS DISC AT THE INTERSECTION
SE 142ND PLACE AND 156TH AVENUE SE.
EXIST EXISTING STD STANDARD ELEVATION = 372.34
FDC FIRE DEPARTMENT CONNECTION TC TOP OF CURB CITY OF RENTON PUBLISHED BENCH DESCRIPTIONS RE REVERSED
FOR
FG FINISH GRADE TEL TELEPHONE BENCHMARKS #2088 AND #1909
FIG FIGURE THRD THREADED SITE CONTROL:
FIN FINISHED THRU THROUGH ESM CONTROL POINT LOCATED 27' NW OF THE INTERSECTION OF SE
FL /FL FLOWLINE TOW/TW TOP OF WALL 136TH ST AND 168TH AVENUE SE.
N 178033.9669, E 1323118.6406, ELEVATION = 466.25
FL FLANGE TYP TYPICAL
FT FEET ESM CONTROL POINT LOCATED 511' WEST OF THE INTERSECTION OF
vERT VERTICAL SE 136TH ST AND 168TH AVENUE SE ON THE SOUTHERLY EDGE OF
FM FORCE MAIN ASPHALT.
W WEST N 178031.6592, E 1322625.8698, ELEVATION = 454.97
GA GAUGE W/ WITH
GALV GALVANIZED W/0 WITHOUT
GI GALVANIZED IRON WSS WATER SAMPLING STATION
GV GATE VALVE CHECKED FOR COMPLIANCE TO CITY STANDARDS
S=362 13 3 RECORD DRAWING
ESM , 0511
walrx xnw ism CITY O R
ESM iz N75 N0�"T�" "'D im5 "991 A:
In ISM /24/12 Two RENTON
.0
ESM 13 DOVER
°I DATUM
•*^�� Planning /Building /Public Works Dept.
IF Iq! CHE Hill
REVISION BY DATE APPR
HERITAGE PLAT SANITARY SEWER EXTENSION 04/23/20111
PHASE 1 (LIBERTY HIGH SCHOOL)
oxwc xu
LEGEND AND GENERAL NOTES LG -01
Git3L - 3ro9133
a:
WETLAND FLAG
-J\;_
POWER POLE W /DROP LINE & LIGHT
e
BIKE RACK
POWER POLE W /DROP LINE, LIGHT & TRANSFORMER
DEBRIS PILE
POWER POLE W /DROP LINE & TRANSFORMER
..
FIRE PIT
POWER POLE W /LIGHT
BOLLARD
POWER POLE W /LIGHT & TRANSFORMER
HORSE SHOE PIT
POWER POLE
t
MAILBOX
POWER POLE W/TRANSFORMER
11
POST MARKER
;..
PAD MOUNTED TRANSFORMER
-(z
SOIL LOG
POWER VAULT /MANHOLE
SIGN
SIGNAL CONTROL BOX
SEPTIC DISTRIBUTION BOX
SIGNAL JUNCTION BOX
SANITARY SEWER STUB MARKER POST
TRAFFIC PEDESTRIAN POLE
-
SEPTIC VENT
_
TRAFFIC SIGNAL POLE
STORM PIPE INLET /OUTLET
TRAFFIC SIGNAL POLE W /UGHT
STORM DRAIN STUB MARKER POST
FIBER OPTIC MANHOLE
"
-
�-
ROOF DRAIN
FIBER OPTIC STUB MARKER POST
ll
CATCH BASIN
..
TELEPHONE GUY ANCHOR
ri
CABLE TV MARKER POST
_
TELEPHONE ANCHOR POLE
..
CABLE TV RISER
TELEPHONE JUNCTION BOX (UG)
f=
SATELLITE DISH
TELEPHONE MANHOLE
LUMINAIRE W /ARM
TELEPHONE STUB MARKER POST
LUMINAIRE
,.
TELEPHONE POLE
LANDSCAPE UGHT
c
TELEPHONE RISER
YARD LIGHT (UNDER 10' TALL)
FIRE DEPT CONNECTION
GAS STUB MARKER POST
HOSE BIB
u.
GAS VALVE
L:
IRRIGATION CONTROL VALVE
°LO
OIL FILLER CAP
C'+
WATER MANHOLE
F,
GUY ANCHOR
WATER STUB MARKER POST
P -'T
GUY POLE
MONITORING WELL
POWER GRATE
INDICATOR VALVE
D
ELECTRICAL JUNCTION PULL/BOX
SPRINKLER HEAD
ELECTRICAL STUB MARKER POST
__
WATER VAULT
1>11
ELECTRICAL METER
WATER WELL
c
GAS
GUARD RAIL
—OIL—
OIL
FENCE, BOARD
P
POWER (BURIED)
---- - - - - ><
FENCE, BARB -WIRE .
— P
— —
POWER (AERIAL)
FENCE, CHAIN -UNK
-Fa
FIBER OPTICS
- - -- --
FENCE, ELECTRIC
- T
TELEPHONE (BURIED)
- <j > - - - - --
FENCE HOG WIRE
— — T
— —
TELEPHONE (AERIAL)
FENCE, SPLIT RAIL
TV CABLE (BURIED)
- —
FENCE, WIRE
— —
—
TV CABLE (AERIAL)
- -
FENCE WROUGHT IRON
-
CREEK OR STREAM CENTERUNE
t
RAILROAD TRACKS
Qi - WETLAND WITH BUFFER
T.E.S.C.P.
— — — CLEARING LIMITS
—x— FILTER FABRIC FENCE
CUTOFF SWALE
- INTERCEPTOR DITCH
-- - - -�-- N.G.P.E. FENCE
® J OBM A.u. S. up EERS LLC
WOO 205
WARNING: FWcraiWay,WA98009 I ®I ®ICI
THE UTILITY LOCATIONS SHOWN www•esmcivil.com
Girl Erpi,s,Lp I Pnject Ya�iwgsmnt I LaM,copaMM1ilaturc
ARE APPROXIMATE ONLY. DEPTH
UNKNOWN. CALL 1- 800 - 424 -5555. ESM JOB #1352- 020 -011
fs
0
0
ROCK CHECK DAM
SEDIMENT FILTER
STRAW BALE
GRAVEL CONE
RIP RR PAD
CONSTRUCTION ENTRANCE
3
No.
STREAM WITH BUFFER
SURVEY
09 PROPOSED MONUMENT IN CASE
® FOUND MONUMENT IN CASE
@am PROPOSED MONUMENT (AS DEFINED)
®am FOUND MONUMENT (AS DEFINED)
A DELTA
(R) RADIAL BEARING < >
(NR) NON- RADIAL BEARING
L RC LENGTH
ABBREVIATIONS GENERAL NOTES:
1. ALL WORK MATERIAL SHALL BE IN CONFORM
WITH THE
AVE AVENUE ID INSIDE DIAMETER LATEST STANDARDS AND SPECIFICATIONS OF THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT AND THE 2008 EDITION OF
AC ASBESTOS CEMENT PIPE IE INVERT ELEVATION THE WSDOT /APWA STANDARDS AND SPECIFICATIONS, AS
APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE
ADJ ADJACENT IN INCHES RENTON STANDARD PLANS & SPECIFICATIONS. SOME STANDARD
ALUM ALUMINUM DETAIL DRAWINGS MAY HAVE BEEN MODIFIED FOR THE CONTRACT.
L LENGTH THE CONTRACTOR SHALL REFER TO DETAIL DRAWINGS INCLUDED
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE LB POUNDS IN THE CONTRACT DOCUMENTS. A SET OF APPROVED PLANS
SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
R ANGLE POINT LF LINEAL FEET
2. ALL LOCATIONS OF EXISTING UTILITIES SHOWN RE APPROXIMATE
ASPH ASPHALT MAX MAXIMUM AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY
ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS MFR MANUFACTURER THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
DISTURBANCE. FOR UTILITY LOCATES CALL 800- 424 -5555 (OR
ASSY ASSEMBLY MH MANHOLE 811) A MINIMUM OF 72 HOURS PRIOR TO EXCAVATION.
BF BLIND FLANGE MIN MINIMUM 3. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE
BLDG BUILDING MJ MECHANICAL JOINT SUBMITTED AT THE PRE — CONSTRUCTION MEETING. ANY
MODIFICATIONS TO THE APPROVED TRAFFIC CONTROL PLAN SHALL
BILK BLOCK MISC MISCELLANEOUS BE RESUBMITTED AND APPROVED PRIOR TO IMPLEMENTATION.
80 BLOW OFF N NORTH 4. ALL FITTINGS SHALL BE BLOCKED PER CITY OF RENTON
BOW /BW BOTTOM OF WALL NO NUMBER STANDARD DETAILS UNLESS OTHERWISE NOTED.
BVC BEGIN VERTICAL CURVE 5. THE CONTRACTOR SHALL USE A VACUUM STREET SWEEPER TO
NITS NOT TO SCALE REMOVE DUST AND DEBRIS FROM PAVEMENT AREA AS DIRECTED
BW BACK OF WALK OC ON CENTER BY THE ENGINEER. FLUSHING OF STREETS SHALL NOT BE
PERMITTED.
CTR CENTER OD OUTSIDE DIAMETER
CB CATCH BASIN 6. BEFORE COMMENCEMENT OF TRENCHING, THE CONTRACTOR
OHW ORDINARY HIGH WATER SHALL PROVIDE A CATCH BASIN FILTER FOR ALL DOWNHILL
CI CAST IRON STORM DRAIN INLETS AND CATCH BASINS. THE CONTRACTOR
PI POINT OF INTERSECTION SHALL PERIODICALLY INSPECT THE CONDITION OF ALL FILTERS
CL /(� CENTERLINE PP POWER POLE AND REPLACE AS NECESSARY.
CLR CLEAR PVT POINT OF VERTICAL INTERSECTION 7. PAVEMENT MARKINGS (E.G. LANE LINE BUTTONS OR PAINT, STOP
CMP CORRUGATED METAL PIPE BARS, CROSSWALKS, ETC.) DAMAGED OR REMOVED DURING
PE POLYETHYLENE CONSTRUCTION SHALL BE REPLACED IN KIND.
CO CLEANOUT PERF PERFORATED
CONIC CONCRETE PVC POLYVINYL CHLORIDE
C CONDUIT PVMT PAVEMENT
CONN CONNECTION PVT POINT OF VERTICAL TANGENCY
CONTR CONTRACTOR PC POINT OF CURVATURE
CONT CONTINUED PT POINT OF TANGENCY NOTE:
CY CUBIC YARDS OTT• QUANTITY
1. LOT LINES ARE BASED ON CIS INFORMATION AND RE FOR
CL CLASS ABET RETAINING ONLY.
2• GRAVITY SANITARY SEWER PIPE MATERIAL:
CF CUBIC FEET RR RAILROAD PVC SDR35 - 4' TO 15' OF COVER
PVC C900 - LESS THAN 4' OF COVER
CPS CUBIC FEET PER SECOND
R RADIUS . PVC C900 - OVER 15' OF COVER
DC DEGREE OF CURVATURE RED REDUCER • PVC C905 - PIPE DIA. GREATER THAN 18" WITH LESS THAN
DI DUCTILE IRON REINF REINFORCED 4' OF COVER OR GREATER THAN 15' OF COVER
DIA /0 DIAMETER REQ REQUIRED
DOT DEPARTMENT OF TRANSPORTATION R/W RIGHT OF WAY
DIM DIMENSION S SOUTH SURVEY DATUM:
DWGS DRAWINGS SCH SCHEDULE HORIZONTAL DATUM:
D DRAIN SO STORM DRAIN NAD83(91) WASHINGTON STATE PLANE COORDINATE SYSTEM NORTH
EOP EDGE OF PAVEMENT SF SQUARE FEET ZONE
E EAST SHT SHEET VERTICAL DATUM:
NAVD 1988 CITY OF RENTON PUBLISHED BENCH MARKS
ELEV ELEVATION SPECS SPECIFICATIONS #1909 CASED MONUMENT WITH LEAD AND TACK AT THE INTERSECTION
EL ELEVATION SO SQUARE OF SE 139th PLACE AND 156TH AVENUE SE.
ELEC ELECTRICAL ELEVATION = 408.64
SS SANITARY SEWER
EVC END VERTICAL CURVE STA STATION #2088 CASE MONUMENT WITH %" BRASS DISC AT THE INTERSECTION
SE 142ND PLACE AND 156TH AVENUE SE.
EXIST EXISTING STD STANDARD ELEVATION = 372.34
FDC FIRE DEPARTMENT CONNECTION TC TOP OF CURB CITY OF RENTON PUBLISHED BENCH DESCRIPTIONS RE REVERSED
FOR
FG FINISH GRADE TEL TELEPHONE BENCHMARKS #2088 AND #1909
FIG FIGURE THRD THREADED SITE CONTROL:
FIN FINISHED THRU THROUGH ESM CONTROL POINT LOCATED 27' NW OF THE INTERSECTION OF SE
FL /FL FLOWLINE TOW/TW TOP OF WALL 136TH ST AND 168TH AVENUE SE.
N 178033.9669, E 1323118.6406, ELEVATION = 466.25
FL FLANGE TYP TYPICAL
FT FEET ESM CONTROL POINT LOCATED 511' WEST OF THE INTERSECTION OF
vERT VERTICAL SE 136TH ST AND 168TH AVENUE SE ON THE SOUTHERLY EDGE OF
FM FORCE MAIN ASPHALT.
W WEST N 178031.6592, E 1322625.8698, ELEVATION = 454.97
GA GAUGE W/ WITH
GALV GALVANIZED W/0 WITHOUT
GI GALVANIZED IRON WSS WATER SAMPLING STATION
GV GATE VALVE CHECKED FOR COMPLIANCE TO CITY STANDARDS
S=362 13 3 RECORD DRAWING
ESM , 0511
walrx xnw ism CITY O R
ESM iz N75 N0�"T�" "'D im5 "991 A:
In ISM /24/12 Two RENTON
.0
ESM 13 DOVER
°I DATUM
•*^�� Planning /Building /Public Works Dept.
IF Iq! CHE Hill
REVISION BY DATE APPR
HERITAGE PLAT SANITARY SEWER EXTENSION 04/23/20111
PHASE 1 (LIBERTY HIGH SCHOOL)
oxwc xu
LEGEND AND GENERAL NOTES LG -01
Git3L - 3ro9133