HomeMy WebLinkAboutS-362808�e HAS GR 8 � `moo cs5 Lee � 16727 �IST6><°O� ioxnl, t� ONE -LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES, AND EQUIPMENT LIGHTING FIXTURES /DEVICES ABBREVIATIONS LADDER LOGIC SYMBOL LEGEND CIRCUIT BREAKER SERVICE ENTRANCE, SWITCHGEAR, SPDT - SINGLE POLE, DOUBLE THROW INDICATOR LIGHT INDICATOR LIGHT RELAY SIGNED: 05/23/12 XXX /YY - CB SIZE & NO. OF POLES ET - ELECTRONIC TRIP MOTOR CONTROL CENTER, OR PANELBOARD FLUORESCENT FIXTURE O BEST - SINGLE POLE, SINGLE THROW BEST - DOUBLE POLE, SINGLE THROW �.( �/`�r A -AMBER G -GREEN RELAY XYZ TR - Timed relay MI LL TM - THERMAL MAGNETIC BREAKER MCP - MOTOR CIRCUIT PROTECTOR �-�\/ WALL /CEILING MOUNTED FIXTURE WP - WEATHER -PROOF GFI - GROUND FAULT INTERRUPT P - POWER B - BLUE R - RED C - CLEAR W - WHITE 123 CR - Control relay y _�C SSY' e *ASA4 +� m� �• o BE - SERVICE ENTRANCE SURFACE MOUNTED PANELBOARD 1 J C - CONTROL GET - GROUND FAULT INTERRUPTER M J - INSTRUMENTATION FLOAT SWITCH FUSE FUSED DISCONNECT SWITCH EMERGENCY LIGHT WITH SELF CJ -POWER &CONTROL CJ . CONTROL &INSTRUMENTATION CKT. - CIRCUIT LIMIT SWITCH �O LIMIT SWITCH, NORMALLY OPEN �O FLOAT SWITCH, NORMALLY OPEN 36613 .�eaD+s:c%gO '�Ptorw. tsT'� PLUG -IN CONNECTION FLUSHED MOUNTED PANELBOARD CONTAINED BATTERY C.O. - CONDUIT ONLY W RTM RUN TIME METER N.L. - NIGHT LIGHT AL. - ALUMINUM LIMIT SWITCH FLOAT SWITCH SIGNED: 05 23 12 / / NXX FIELD CONTROL STATION WITH NEMA REQUIREMENTS. O SURFACE OR PENDANT MOUNTED FIXTURE CU. - COPPER �� LIMIT SWITCH, NORMALLY CLOSED 0�7�� FLOAT SWITCH, NORMALLY CLOSED J� OC MOTOR OPERATION COUNTER �J � y '� N3R - NEMA 3R O RECESSED FIXTURE O BOA HAND -OFF -AUTO SWITCH ETM RUN TIME METER N4 - NEMA 4 OC OPERATION COUNTER TIME DELAY CONTACT PUSHBUTTON pp - SOLID STATE N4SS - NEMA 4 STAINLESS STEEL 14F - NEMA 4 FIBERGLASS MD MOTION DETECTOR MRIL MOTOR RUN INDICATION LIGHT §F—IL o TIME DELAY CONTACT, NORMALLY OPEN, TIME TO CLOSE Q� PUSHBUTTON, NORMALLY CLOSED O (c� REDUCED REDUCED VOLTAGE STARTER N6 -NEMA 6 SEAL FAIL INDICATION LIGHT _SF �\ � N12 - NEMA 12 GASKETED PC PHOTO CONTROL CELL SEAL FAIL TRIP RESET OTIL OVER TEMPERATURE INDICATION LIGHT ti VARIABLE FREQUENCY DRIVE MOUNTING STAND MOIL MOTOR OVERLOAD INDICATION LIGHT TIME DELAY CONTACT ^ V—/\ V TIME DELAY CONTACT NORMALLY PUSHBUTTON PUSHBUTTON, NORMALLY OPEN SWITCH OUTLETS ti S ® STANDARD SWITCH, 120VAC, 20 AMP CLOSED, TIME TO OPEN O O INDICATE TYPE BY MOTOR STARTER LETTER INSTRUMENT METER THERMOSTAT HEATER, WATTAGE NOTED S ® 3 -WAY SWITCH, 120VAC, 20 AMP TIME DELAY CONTACT A B MOTOR STARTER W/ OPERATOR 3 3WAY ^ A - AMMETER VAR - VARMETER AH - AMPERE -HOUR VARH - VARHOUR METER O� O TIME DELAY CONTACT, NORMALLY OPEN, TIME TO OPEN O THERMO SWITCH, NORMALLY OPEN DEVICES C D A -HAND -OFF -AUTO ® EQUIPMENT CONNECTION 3- POSITION SWITCH, 120VAC, 20 AMP, S ® LABEL SWITCH POSITION PF - POWER FACTOR W - WATTMETER �V B - OPERATIONAL COUNTER BOA HOA HAND - OFF - MOTION OR PHOTO AM V - VOLTMETER WH - WATTHOUR METER TIME DELAY CONTACT THERMOSTAT C - RUN TIME METER D - RUN LIGHT V M A � SINGLE PHASE MOTOR. HORSEPOWER AS NOTED VA -VOLT AMMETER TIME DELAY CONTACT, NORMALLY CLOSED, TIME TO CLOSE THERMO SWITCH, NORMALLY CLOSED RACE WAY LEGEND E -FAIL LIGHT \/ S SINGLE -POLE S PILOT- LIGHTED F - EMERGENCY STOP DEE P 51rEPllVJLFGENO OK KIRK KEY INTERLOCK 1pp THREE P PHASE MOTOR. HORSEPOWER AS NOTED S DOUBLE -POLE 2 S KEY - OPERATED K P PROPOSED POWER RELAY CONTACT NC FLOWSWITCH Z S THREE WAY S LOW VOLTAGE RELAY CONTACT, INSTANTANEOUS CHANGE FLOWSMTCH, NORMALLY OPEN O W POWER TRANSFORMER 3 LV TEL PROPOSED TELEPHONE RELAY CONTACT, NO �O O a CONTROL POWER TRANSFORMER HP SINGLE PHASE MOTOR. HORSEPOWER AS NOTED S FOUR WAY 4 S MASTER M TES^ PROPOSED INSTRUMENTATION Q �;/ LLI 4 S DIMMER ❑� PUSHBUTTON .�.....�.iw PRESSURE SWITCH y TRANSFORMER ELECTRICAL PLUG D Eo PROPOSED FIBER OPTICS O FLOWSWITCH FLOWSWITCH, NORMALLY CLOSED 1 W F d FIRE SYSTEM SYMBOLS 001-01NG OR FAG/L" FL/tN LFGFNO PRESSURE SWITCH, NORMALLY OPEN �� U. OH HEAT DETECTOR CURRENT TRANSFORMER � DISCONNECT SWITCH EXPOSED RACEWAY OS SMOKE DETECTOR _ _ _ _ _ CONCEALED, UNDERGROUND, EMBEDDED, OR PRESSURE SWITCH r r VOLTAGE TRANSFORMER �� FUSED DISCONNECT SWITCH CONCRETE ENCASED RACEWAY 2 POLE SWITCH I_1 I �D FIRE ALARM DISPATCH STROBE ALARM � PRESSURE SWITCH, NORMALLY CLOSED W - HOME RUN TO PANELBOARD OR AS INDICATED y CONTACTOR N-71� COMBINATION MOTOR STARTER ® FIRE ALARM AUDIBLE /VISUAL ALARM M ! W T VIII AND DISCONNECT SWITCH C CONDUIT RUN, BROKEN AND CONTINUED SAME 0 I LU ❑ FIRE ALARM MANUAL PULL STATION SHEET OR AS NOTED / W T CAPACITOR FLEXIBLE CONDUIT n Ir a RECEPTACLES AND JUNCTION BOX SYMBOLS ADDITIONAL SYMBOLS OJ CEILING JUNCTION BOX O SOUND SYSTEM SPEAKER ENGINE GENERATOR i H CONDUIT RUN. HATCH MARKS INDICATE NUMBER OF CONDUCTORS n 3 POLE SWITCH GENERATOR CONNECTION WALL JUNCTION BOX V SOUND SYSTEM VOLUME CONTROL CALLOUT INDICATING CONDUIT SIZE, NUMBER �— RECEPTACLE Y2- GIRD, , 2 -g12 AND SIZE OF WIRE. S ❑j FLOOR JUNCTION BOX DOORBELL NJSOLID NEUTRAL DUPLEX WALL RECEPTACLE , 120V \O CALLOUT INDICATING CONDUIT PER SCHEDULE VALVE SYMBOLS TB TERMINAL BLOCK WP = WEATHERPROOF G = GROUNDED XXX IG = ISOLATED GROUND PILOT VALVE SOLENOID CONDUIT BENT UP OR TOWARD • CF = GROUND FAULT INTERRUPTER SURGE PROTECTION DEVICE DOUBLE DUPLEX D CONDUIT BENT DOWN OR AWAY ENGINEER S PLANNER S I� SINGLE RECEPTACLE, I�TiI I VALVE GENERAL NOTES SPD SURGE PROTECTION DEVICE fe 120V V V ] CAPPED CONDUIT 0 0 (ALTERNATIVE) 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE WILL SCIENTISTS b SINGLE RECEPTACLE, 208V \ 1 CHECK VALVE ELECTRICAL & SIGNAL PLAN DEVICES APPEAR IN THIS SET OF PLANS. RH2 ENGINEERING, G, INC. GROUNDING SYSTEM SYMBOLS DUPLEX FLOOR RECEPTACLE, 120V I V O O$ SV SOLENOID VALVE COIL ZS INTRUSION SWITCH 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL EQUIPMENT il 2co"' ® SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE INSTALLATION OF ALL EQUIPMENT oxiEr 1 malbox�h2 com 7.800.720.8052 1 GROUND SPECIAL PURPOSE WALL RECEPTACLE, �^ MV MOTORIZED VALVE COIL MD MOTION DETECTOR SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY BELLINGHAM eeo.en,aoeae 454 West Horton Road METAL PIPE GROUND NO O [G RATING AS NOTED CLOCK 11//VI CONTROL VALVE M LT LEVEL TRANSDUCER O MOTOR O COMPANY STANDARDS, CONTACT THE UTILITY REQUIREMENTS. COMPANY REPRESENTATIVES AND VERIFY THEIR BOTHELL vs.ssi.rrm 22722 29th Drive SE, Suite 210 ELECTRICAL SITE PLAN SYMBOLS CONNECTION POINT, EXOTHERMIC WELD. 3. NOTIFY THE ENGINEER IMMEDIATELY IF OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED LACK OF INFORMATION OR ANY OTHER EAST w NATCHEE soe.eee. CADWELD OR APPROVED EQUAL. N TELEVISION FS FLOOD SWITCH HE HEATING ELEMENT 300 Simon Street, Suite 5 UTILITY POLE AND GUY WIRE REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY • GROUND ROD SIZED PER N.E.C. USE EXOTHERMIC WELD CONNECTION AT , TELEPHONE = HH MANHOLE OR HANDHOLE LS LIMIT SWITCH PS PRESSURE SWITCH REVIEWED BY THE ENGINEER. RICHuNO aos,Suite , n4 Columbia Point Drive, Suite C THE GROUND ROD. TELEPHONE /DATA WITH CABLE HH� BURIED POWER VAULT OR MANHOLE PB PANIC BUTTON PE PRESSURE ELEMENT sLVEROaLE aw.alavaeo 2021 NW Mhyre Rd, Suite 107 PIGTAIL, BARE COPPER, LENGTH AS TACOMA zso, 17 . REQUIRED, l MINIMUM. �T TELEPHONE VAULT OR PEDESTAL OT THERMOSTAT SWITCH FE FLOW ELEMENT 621 P.6fic Avenue Suite 104 CONNECTION POINT, MECHANICAL, S=362808 SCALE: SHOWN � COMPRESSION TYPE. �F FIBER OPTICS VAULT OR PEDESTAL EY ZS INTRUSION SWITCH - KEY AE ANALYSIS ELEMENT 0 1" 2" o-n LUMINAIRE DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG PAD -MOUNT TRANSFORMER RECORD DRAWING 0.0T: 1 DrG ND. f REVISED TO CONFORM TO CON TRUCTIO RECORDS GGA E01 mN MLM ROAD 04/25/12 DAm Jul 15, 2013 %EETT Na. RH2 RING INC. DATE WENT: REN 8 Qj REVISED TO CONFORM TO CONSTRUCTION RECORDS I AHF I EH 04/25/13 17 .ae ND.: 112 -033 amNiUdeUBHS- D- EOI.DWG NO. REVISION I BY REVIEW1 DATE