HomeMy WebLinkAboutS-362808�e HAS
GR 8 � `moo cs5
Lee �
16727
�IST6><°O�
ioxnl, t�
ONE -LINE DIAGRAM SYMBOLS
PANELBOARDS,
SWITCHES, AND EQUIPMENT
LIGHTING FIXTURES /DEVICES
ABBREVIATIONS
LADDER LOGIC SYMBOL LEGEND
CIRCUIT BREAKER
SERVICE ENTRANCE, SWITCHGEAR,
SPDT - SINGLE POLE, DOUBLE THROW
INDICATOR LIGHT
INDICATOR LIGHT
RELAY
SIGNED: 05/23/12
XXX /YY - CB SIZE & NO. OF POLES
ET - ELECTRONIC TRIP
MOTOR CONTROL CENTER, OR
PANELBOARD
FLUORESCENT FIXTURE
O
BEST - SINGLE POLE, SINGLE THROW
BEST - DOUBLE POLE, SINGLE THROW
�.(
�/`�r
A -AMBER G -GREEN
RELAY
XYZ TR - Timed relay
MI LL
TM - THERMAL MAGNETIC BREAKER
MCP - MOTOR CIRCUIT PROTECTOR
�-�\/
WALL /CEILING MOUNTED FIXTURE
WP - WEATHER -PROOF
GFI - GROUND FAULT INTERRUPT
P - POWER
B - BLUE R - RED
C - CLEAR W - WHITE
123 CR - Control relay
y
_�C
SSY' e *ASA4
+�
m� �• o
BE - SERVICE ENTRANCE
SURFACE MOUNTED PANELBOARD
1 J
C - CONTROL
GET - GROUND FAULT INTERRUPTER
M
J - INSTRUMENTATION
FLOAT SWITCH
FUSE
FUSED DISCONNECT SWITCH
EMERGENCY LIGHT WITH SELF
CJ -POWER &CONTROL
CJ . CONTROL &INSTRUMENTATION
CKT. - CIRCUIT
LIMIT SWITCH
�O
LIMIT SWITCH, NORMALLY OPEN
�O FLOAT SWITCH, NORMALLY OPEN
36613
.�eaD+s:c%gO
'�Ptorw. tsT'�
PLUG -IN CONNECTION
FLUSHED MOUNTED PANELBOARD
CONTAINED BATTERY
C.O. - CONDUIT ONLY
W
RTM
RUN TIME METER
N.L. - NIGHT LIGHT
AL. - ALUMINUM
LIMIT SWITCH
FLOAT SWITCH
SIGNED: 05 23 12
/ /
NXX
FIELD CONTROL STATION WITH NEMA
REQUIREMENTS.
O SURFACE OR PENDANT MOUNTED
FIXTURE
CU. - COPPER
��
LIMIT SWITCH, NORMALLY CLOSED
0�7�� FLOAT SWITCH, NORMALLY CLOSED
J�
OC
MOTOR OPERATION COUNTER
�J
� y
'�
N3R - NEMA 3R
O RECESSED FIXTURE
O
BOA HAND -OFF -AUTO SWITCH
ETM RUN TIME METER
N4 - NEMA 4
OC OPERATION COUNTER
TIME DELAY CONTACT
PUSHBUTTON
pp
- SOLID STATE
N4SS - NEMA 4 STAINLESS STEEL
14F - NEMA 4 FIBERGLASS
MD MOTION DETECTOR
MRIL MOTOR RUN INDICATION LIGHT
§F—IL
o
TIME DELAY CONTACT, NORMALLY OPEN,
TIME TO CLOSE
Q� PUSHBUTTON, NORMALLY CLOSED
O
(c�
REDUCED
REDUCED VOLTAGE STARTER
N6 -NEMA 6
SEAL FAIL INDICATION LIGHT
_SF
�\
�
N12 - NEMA 12 GASKETED
PC PHOTO CONTROL CELL
SEAL FAIL TRIP RESET
OTIL OVER TEMPERATURE INDICATION LIGHT
ti
VARIABLE FREQUENCY DRIVE
MOUNTING STAND
MOIL MOTOR OVERLOAD INDICATION LIGHT
TIME DELAY CONTACT
^
V—/\ V
TIME DELAY CONTACT NORMALLY
PUSHBUTTON
PUSHBUTTON, NORMALLY OPEN
SWITCH OUTLETS
ti
S ® STANDARD SWITCH, 120VAC, 20 AMP
CLOSED, TIME TO OPEN
O O
INDICATE TYPE BY
MOTOR STARTER
LETTER
INSTRUMENT METER
THERMOSTAT
HEATER, WATTAGE NOTED
S ® 3 -WAY SWITCH, 120VAC, 20 AMP
TIME DELAY CONTACT
A B
MOTOR STARTER W/ OPERATOR
3 3WAY
^
A - AMMETER VAR - VARMETER
AH - AMPERE -HOUR VARH - VARHOUR METER
O� O
TIME DELAY CONTACT, NORMALLY OPEN,
TIME TO OPEN
O THERMO SWITCH, NORMALLY OPEN
DEVICES
C D
A -HAND -OFF -AUTO
®
EQUIPMENT CONNECTION
3- POSITION SWITCH, 120VAC, 20 AMP,
S ® LABEL SWITCH POSITION
PF - POWER FACTOR W - WATTMETER
�V
B - OPERATIONAL COUNTER
BOA HOA HAND - OFF - MOTION OR PHOTO
AM
V - VOLTMETER WH - WATTHOUR METER
TIME DELAY CONTACT
THERMOSTAT
C - RUN TIME METER
D - RUN LIGHT
V M A
�
SINGLE PHASE MOTOR.
HORSEPOWER AS NOTED
VA -VOLT AMMETER
TIME DELAY CONTACT, NORMALLY
CLOSED, TIME TO CLOSE
THERMO SWITCH, NORMALLY CLOSED
RACE WAY LEGEND
E -FAIL LIGHT
\/
S SINGLE -POLE
S PILOT- LIGHTED
F - EMERGENCY STOP
DEE
P
51rEPllVJLFGENO
OK
KIRK KEY INTERLOCK
1pp
THREE P
PHASE MOTOR.
HORSEPOWER AS NOTED
S DOUBLE -POLE
2
S KEY - OPERATED
K
P PROPOSED POWER
RELAY CONTACT NC
FLOWSWITCH
Z
S THREE WAY
S LOW VOLTAGE
RELAY CONTACT, INSTANTANEOUS CHANGE
FLOWSMTCH, NORMALLY OPEN
O
W
POWER TRANSFORMER
3
LV
TEL PROPOSED TELEPHONE
RELAY CONTACT, NO
�O
O
a
CONTROL POWER TRANSFORMER
HP
SINGLE PHASE MOTOR.
HORSEPOWER AS NOTED
S FOUR WAY
4
S MASTER
M
TES^ PROPOSED INSTRUMENTATION
Q
�;/
LLI
4
S DIMMER
❑� PUSHBUTTON
.�.....�.iw
PRESSURE SWITCH
y
TRANSFORMER
ELECTRICAL PLUG
D
Eo PROPOSED FIBER OPTICS
O
FLOWSWITCH
FLOWSWITCH, NORMALLY CLOSED
1
W
F
d
FIRE SYSTEM SYMBOLS
001-01NG OR FAG/L" FL/tN LFGFNO
PRESSURE SWITCH, NORMALLY OPEN
��
U.
OH HEAT DETECTOR
CURRENT TRANSFORMER
�
DISCONNECT SWITCH
EXPOSED RACEWAY
OS SMOKE DETECTOR
_ _ _ _ _ CONCEALED, UNDERGROUND, EMBEDDED, OR
PRESSURE SWITCH
r
r
VOLTAGE TRANSFORMER
��
FUSED DISCONNECT SWITCH
CONCRETE ENCASED RACEWAY
2 POLE SWITCH
I_1 I
�D FIRE ALARM DISPATCH STROBE ALARM
�
PRESSURE SWITCH, NORMALLY CLOSED
W
- HOME RUN TO PANELBOARD OR AS INDICATED
y
CONTACTOR
N-71�
COMBINATION MOTOR STARTER
® FIRE ALARM AUDIBLE /VISUAL ALARM
M
!
W
T
VIII
AND DISCONNECT SWITCH
C CONDUIT RUN, BROKEN AND CONTINUED SAME
0
I
LU
❑ FIRE ALARM MANUAL PULL STATION
SHEET OR AS NOTED
/
W
T
CAPACITOR
FLEXIBLE CONDUIT
n Ir a
RECEPTACLES AND JUNCTION BOX SYMBOLS
ADDITIONAL SYMBOLS
OJ
CEILING JUNCTION BOX
O SOUND SYSTEM SPEAKER
ENGINE GENERATOR
i H CONDUIT RUN. HATCH MARKS INDICATE NUMBER
OF CONDUCTORS
n 3 POLE SWITCH
GENERATOR CONNECTION
WALL JUNCTION BOX
V SOUND SYSTEM VOLUME CONTROL
CALLOUT INDICATING CONDUIT SIZE, NUMBER
�—
RECEPTACLE
Y2- GIRD, , 2 -g12 AND SIZE OF WIRE.
S
❑j
FLOOR JUNCTION BOX
DOORBELL
NJSOLID
NEUTRAL
DUPLEX WALL RECEPTACLE , 120V
\O
CALLOUT INDICATING CONDUIT PER SCHEDULE
VALVE SYMBOLS
TB
TERMINAL BLOCK
WP = WEATHERPROOF
G = GROUNDED
XXX
IG = ISOLATED GROUND
PILOT VALVE SOLENOID
CONDUIT BENT UP OR TOWARD
•
CF = GROUND FAULT INTERRUPTER
SURGE PROTECTION DEVICE
DOUBLE DUPLEX
D CONDUIT BENT DOWN OR AWAY
ENGINEER S
PLANNER S
I� SINGLE RECEPTACLE,
I�TiI
I VALVE
GENERAL NOTES
SPD
SURGE PROTECTION DEVICE
fe
120V
V V
] CAPPED CONDUIT
0 0
(ALTERNATIVE)
1. THIS IS A STANDARD LEGEND. NOT ALL
OF THE INFORMATION SHOWN ON THIS PAGE WILL
SCIENTISTS
b
SINGLE RECEPTACLE, 208V
\ 1 CHECK VALVE
ELECTRICAL & SIGNAL PLAN DEVICES
APPEAR IN THIS SET OF PLANS.
RH2 ENGINEERING, G, INC.
GROUNDING SYSTEM SYMBOLS
DUPLEX FLOOR RECEPTACLE, 120V
I V
O O$
SV SOLENOID VALVE COIL ZS INTRUSION SWITCH
2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY;
EXACT LOCATIONS OF ELECTRICAL EQUIPMENT
il 2co"'
®
SHALL BE DETERMINED IN THE FIELD BY THE
CONTRACTOR. THE INSTALLATION OF ALL EQUIPMENT
oxiEr 1
malbox�h2 com 7.800.720.8052
1
GROUND
SPECIAL PURPOSE WALL RECEPTACLE,
�^
MV MOTORIZED VALVE COIL MD MOTION DETECTOR
SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE
REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY
BELLINGHAM eeo.en,aoeae
454 West Horton Road
METAL PIPE GROUND
NO
O [G
RATING AS NOTED
CLOCK
11//VI CONTROL VALVE
M LT LEVEL TRANSDUCER
O MOTOR O
COMPANY STANDARDS, CONTACT THE UTILITY
REQUIREMENTS.
COMPANY REPRESENTATIVES AND VERIFY THEIR
BOTHELL vs.ssi.rrm
22722 29th Drive SE, Suite 210
ELECTRICAL SITE PLAN SYMBOLS
CONNECTION POINT, EXOTHERMIC WELD.
3. NOTIFY THE ENGINEER IMMEDIATELY IF
OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS,
CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED
LACK OF INFORMATION OR ANY OTHER
EAST
w NATCHEE soe.eee.
CADWELD OR APPROVED EQUAL.
N
TELEVISION
FS FLOOD SWITCH HE HEATING ELEMENT
300 Simon Street, Suite 5
UTILITY POLE AND GUY WIRE
REASON. NO PAYMENT WILL BE MADE FOR
CHANGES WHICH HAVE NOT BEEN FAVORABLY
•
GROUND ROD SIZED PER N.E.C. USE
EXOTHERMIC WELD CONNECTION AT
,
TELEPHONE
= HH MANHOLE OR HANDHOLE
LS LIMIT SWITCH PS PRESSURE SWITCH
REVIEWED BY THE ENGINEER.
RICHuNO aos,Suite ,
n4 Columbia Point Drive, Suite C
THE GROUND ROD.
TELEPHONE /DATA WITH CABLE
HH� BURIED POWER VAULT OR MANHOLE
PB PANIC BUTTON PE PRESSURE ELEMENT
sLVEROaLE aw.alavaeo
2021 NW Mhyre Rd, Suite 107
PIGTAIL, BARE COPPER, LENGTH AS
TACOMA zso, 17 .
REQUIRED, l MINIMUM.
�T TELEPHONE VAULT OR PEDESTAL
OT THERMOSTAT SWITCH FE FLOW ELEMENT
621 P.6fic Avenue Suite 104
CONNECTION POINT, MECHANICAL,
S=362808
SCALE: SHOWN
�
COMPRESSION TYPE.
�F FIBER OPTICS VAULT OR PEDESTAL
EY
ZS INTRUSION SWITCH - KEY AE ANALYSIS ELEMENT
0 1" 2"
o-n LUMINAIRE
DRAWING IS NOT TO SCALE
IF BAR IS NOT 2" LONG
PAD -MOUNT TRANSFORMER
RECORD DRAWING
0.0T: 1
DrG ND.
f
REVISED TO CONFORM
TO CON TRUCTIO RECORDS
GGA
E01
mN MLM
ROAD
04/25/12
DAm Jul 15, 2013
%EETT Na.
RH2 RING INC. DATE
WENT: REN
8
Qj REVISED TO CONFORM TO CONSTRUCTION
RECORDS I AHF I EH 04/25/13
17
.ae ND.: 112 -033
amNiUdeUBHS- D- EOI.DWG
NO. REVISION I BY REVIEW1 DATE