Loading...
HomeMy WebLinkAboutS-362814�' OT H "aar 16727 8acrssa%8�� �raxnt BUBBLER TUBE FOR BELLOWS. JACKETED CABLE FOR LEVEL TRANSDUCER. SIGNED: 05/23/12 MILL 0 0 -__ - 4p �Aa/Y I VAULT LID MARKED 0 0 I 2" UNISTRUT. SECURE UNISTRUT "ELECTRICAL" WITH WELD BEAD. TO HANDHOLE WALLS. 3,613 TO MOTOR CONTROL CENTER /RTU TO WETWELL o o I PLASTIC TUBE COUPLING. SIZE BecTSpaa�o AS NECESSARY. r0IST r JUNCTION BOX (TYPICAL). .: TO "MCC'. _ PUMP POWER CONDUIT �— ?-- - - - -�] - - -____ ;?�i�; - ' -- I --_ _ _ -_ _ SIGNED: 05/23/12 d' a': ". PUMP MOTOR CABLE, -- 12" MAX, TIP 14. ° FLOAT CABLE, OR LEVEL SEAL (TYPICAL).,, °: TRANSMITTER CABLE I q _ °i: 0 0 I SEAL PVC SLEEVE WATERTIGHT ° - - - '. SEAL (TYPICAL), WITH DUCT SEAL (TYPICAL). - j °. <. CONDUIT (TYPICAL). CONTRACTOR / a - ° I'I 1 . 4 : .° 0 0 I r. -' .x PVC CONDUIT SLEEVE. / o (TYPICAL). SEAL TYPICAL o SEAL PVC SLEEVE WATERTIGHT WITH DUCT SEAL TYPICAL). - - - - ( UL SHALL GROUT FILL AROUND Ja a CONDUIT WITH NON- SHRINK GROUT e FOR WATER TIGHTNESS. as 4 I : 2" UNISTRUT (TYPICAL). TO "MCC ". PUMP POWER CONDUIT - - -__ - -- �4� �` • _' - -- TO WETWELL (TYPICAL) - - - - _. 0 PVC CONDUIT SLEEVE. TO WETWELL. -:4 °x4 "x4° 4 a FLEXIBLE CORD CONNECTOR TO "RTU" / -_.� - _ (TYPICAL) �7m O �lV i 1/4 STEEL PLATE. WELD_ d.. (TYPICAL). (TYPICAL) - - - - - - -I - - - - - -- I -- - - UNISTRUT TO PLATE AND MOUNT TO:° aa. G1A551DN15/0Nl 0 0 WALLS OF HANDHOLE USING (4) 3/ 8° O ° °: I AFEA BELL END OF CONDUIT I I STAINLESS STEEL CONCRETE ANCHORS. '. -a -,;4:: g 0 0 (TYPICAL). 0 0 d',9.4r SLOPE CABLE r SLEEVE TOWARDS E06 _. C1P551DN15FJN1 0 0 WIRE NUT ENDS TOGETHER AND SEAL ° WETWELL r- n M, EA WATER TIGHT FOR TERMINATING .Pa u ° / TO BUILDING LIGHT SM TCHr— B 0 0 CABLE TO FIELD WIRE (TYPICAL). a ° O I I s °e ' .° . a e ° - -- - ' e e a . n ° e "o ' ° " � " e' 'aa " '"c ° ' • o° o ° ' A a 6" GRANULAR FILL. EXPLOSION PROOF JUNCTION BOX ° ° COIL MINIMUM OF 5 FEET OF EXCESS CORD. I 0 0 . � 0 o i T / WITH COVER. 0 -Z GEDNEY GUJC TYPE 0 - - - -- WARE NUT ENDS TOGETHER AND /', !i BOX OR EQUAL. SECURE JUNCTION SEAL WATER TIGHT FOR TERMINATING 0 0 Z '^ V/ BOX TO UNISTRUT USING 1/4" 12 STAINLESS STEEL BOLTS. CABLE TO FIELD WIRE (TYPICAL). J LIFTING INSERTS (TYPICAL). 0 0 Q ELECTRICAL HANDHOLE, UTILITY VAULT 0 Fr 0 0 MODEL 233 -LA OR EQUAL. EXPLOSION PROOF JUNCTION BOX WITH COVER. O -Z /GEDNEY GUJC 0 0 Z W MOTOR SPLICE HANDHOLE PLAN DETAIL TYPE BOX EQUAL. SECURE C SPLICE HANDHOLE ELEVATION A 0 JUNCTION BOX TO UNISTRUT USING O 0 p - -i 1_ J o6 NOT TO SCALE 1/4° STAINLESS STEEL BOLTS.I LL. NOT TO SCALE 0 0 - Q I b 2" UNISTRUT. SECURE UNISTRUT TO HANDHOLE WALLS. 0 "b W V W 0 0 m CADWELD TYPE TA. CADWELD 0 0 W CABLE TO CABLE TEE CADWELD TYPE RR. CADWELD CONNECTION. END CABLE TO UPPER REBAR COPPER CONDUCTOR ` - - - 0 0 - - - - - - CONNECTION. 0 REBAR ELECTRICAL HANDHOLE, UTILITY #6 COPPER CONDUCTOR VAULT MODEL 233 -LA OR LIFTING INSERTS (TYPICAL). EQUAL. FLOAT /LEVEL TRANSMITTER SPLICE HANDHOLE PLAN PROPOSED CONCRETE COVER, GRADE NOT TO SCALE . GROUND TEE DETAIL GROUND REBAR DETAIL NOT TO SCALE NOT TO SCALE PROPOSED CONCRETE GROUND ROD NATIVE MATERIAL COMPACTED TO 95% RED ELECTRICAL WARNING TAPE ENGINEERS PLANNER S PROTECTOR 13" DEPTH X 12" HEIGHT WITH PER ASTM D1557 OR AS REQUIRED CENTERED OVER EACH CONDUIT RESTORE SURFACE TO EXISTING SCIENTIST S COVER. PIPE INC. #12R -12A & 12R -12T, OR PER PLAN IN TRENCH (TYP) CONDITION OR BETTER PER PLANS EQUAL. RH2 ENGINEERING, INC. CADWELD TYPE XA. CADWELD http://www.rh2.com mdb aox0rh2com 1.800.720.8052 CADWELD TYPE OR CABLE TO CABLE CROSS CADWELD CABLE TO GROUND CONNECTION. " cc, ° x �' w BELLINGHAM aocl. a. sae 454 West Horton Road # 6 COPPER CONDUCTOR ROD CONNECTION. 5 8x8' / LONG COPPER GROUND ROD. ��°, 9 ° °� ° ,n z m o BOTHELL "zsss,.saoo 22722 29th Drive SE, Suite 210 oz 6" 3 a 1. EAST WENATCHEE sos asa z000 COVER CONDUITE N HIGHEST TRENCH / O O " 300 Simon Street, Swte 5 5/8" X 8' COPPER GROUND ROD. #6 COPPER CONDUCTOR SAND BEDDING MATERIAL PER RICHLAND soa.a"asta, 114 Columbia Point Drive, Suite C (TYPICAL) MINIMUM DEPTH BELOW BOTTOM WSDOT SPECIFICATION 9 -03.13 OF DEEPEST CONDUIT 3" SILVERDALE aso.s,.,aso INSTALLED IN TRENCH �, ELECTRICAL CONDUIT NUMBER AND SIZE 2021 Hw Mnyre R4 Suite 107 -� VARY AS PER SITE PLAN. MAINTAIN 12" TACOMA ..zozaoss GROUND TEE DETAIL GROUND CROSS DETAIL SPACING BETWEEN TELEMETRY CONDUITS AND OTHER CONDUITS. 621 Pacific Avenue Suite 104 SCALE: SHOWN NOT TO SCALE NOT TO SCALE v TYPICAL ELECTRICAL TRENCH DETAIL 0 1 2 NOT TO SCALE DRAWING IS NOT TO SCALE GROUND ROD DETAIL NOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALL BE RECORD DRAWING IF BAR IS NOT 2" LONG ow6 NO. CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION. REVISED TO CONFORM ROT. 1 owwma CCA GROUNDING CONNECTION DETAILS NOT TO SCALE S=362814 TO CON TRUCTIO RECORDS EOG revewFU: MLM ALM NOT TO SCALE 04DATE72 Jul 2013 �¢T NO w a NT: REN75, RH2 RING INC. REVISED TO CONFORM TO CONSTRUCTION RECORDS AHF EH 04/25/13 17 JOB NI: 112 -033 nuNwe UBHS- D- E06.DWG NO. I REVISION I BY REVIEW1 DATE