HomeMy WebLinkAboutS-362814�' OT H "aar
16727
8acrssa%8��
�raxnt
BUBBLER TUBE FOR BELLOWS.
JACKETED CABLE FOR LEVEL
TRANSDUCER.
SIGNED: 05/23/12
MILL
0 0
-__ -
4p �Aa/Y
I
VAULT LID MARKED
0 0 I
2" UNISTRUT. SECURE UNISTRUT
"ELECTRICAL" WITH WELD BEAD.
TO HANDHOLE WALLS.
3,613
TO MOTOR CONTROL CENTER /RTU
TO WETWELL
o o I
PLASTIC TUBE COUPLING. SIZE
BecTSpaa�o
AS NECESSARY.
r0IST
r
JUNCTION BOX (TYPICAL).
.:
TO "MCC'. _
PUMP POWER CONDUIT �— ?-- -
- - -�] - - -____
;?�i�; - ' -- I --_
_ _ -_
_
SIGNED: 05/23/12
d'
a': ". PUMP MOTOR CABLE,
--
12" MAX, TIP 14. ° FLOAT CABLE, OR LEVEL
SEAL (TYPICAL).,, °: TRANSMITTER CABLE
I
q
_ °i:
0 0 I
SEAL PVC SLEEVE WATERTIGHT
° - - -
'.
SEAL (TYPICAL),
WITH DUCT SEAL (TYPICAL).
-
j °. <.
CONDUIT (TYPICAL). CONTRACTOR / a
- °
I'I 1 . 4 :
.°
0 0 I
r. -' .x
PVC CONDUIT SLEEVE.
/
o
(TYPICAL).
SEAL TYPICAL
o SEAL PVC SLEEVE WATERTIGHT
WITH DUCT SEAL TYPICAL).
- - - - (
UL
SHALL GROUT FILL AROUND Ja a
CONDUIT WITH NON- SHRINK GROUT e
FOR WATER TIGHTNESS. as
4
I : 2" UNISTRUT (TYPICAL).
TO "MCC ".
PUMP POWER CONDUIT - -
-__ -
-- �4� �` • _'
- --
TO WETWELL (TYPICAL)
- - - - _.
0
PVC CONDUIT SLEEVE.
TO WETWELL.
-:4
°x4 "x4°
4
a
FLEXIBLE CORD CONNECTOR
TO "RTU"
/ -_.�
- _ (TYPICAL)
�7m O
�lV i
1/4 STEEL PLATE. WELD_
d..
(TYPICAL).
(TYPICAL) - - - - - - -I
- - - - - -- I
-- - -
UNISTRUT TO PLATE AND MOUNT TO:°
aa.
G1A551DN15/0Nl 0 0
WALLS OF HANDHOLE USING (4) 3/ 8°
O
° °:
I AFEA
BELL END OF CONDUIT
I
I
STAINLESS STEEL CONCRETE ANCHORS. '. -a
-,;4::
g
0 0
(TYPICAL).
0 0
d',9.4r
SLOPE CABLE
r SLEEVE TOWARDS
E06
_.
C1P551DN15FJN1
0 0
WIRE NUT ENDS TOGETHER AND SEAL
°
WETWELL
r- n
M, EA
WATER TIGHT FOR TERMINATING
.Pa
u
°
/
TO BUILDING LIGHT SM TCHr—
B
0 0
CABLE TO FIELD WIRE (TYPICAL).
a
°
O
I
I
s °e ' .° .
a e
° - -- - '
e e a . n ° e "o ' ° " � " e' 'aa " '"c ° ' • o° o ° '
A a 6" GRANULAR FILL.
EXPLOSION PROOF JUNCTION BOX
° °
COIL MINIMUM OF 5 FEET OF
EXCESS CORD.
I
0 0
.
�
0 o
i
T
/
WITH COVER. 0 -Z GEDNEY GUJC TYPE
0 - - - --
WARE NUT ENDS TOGETHER AND
/',
!i
BOX OR EQUAL. SECURE JUNCTION
SEAL WATER TIGHT FOR TERMINATING
0 0
Z
'^
V/
BOX TO UNISTRUT USING 1/4" 12
STAINLESS STEEL BOLTS.
CABLE TO FIELD WIRE (TYPICAL).
J
LIFTING INSERTS (TYPICAL).
0 0
Q
ELECTRICAL HANDHOLE, UTILITY
VAULT
0 Fr
0 0
MODEL 233 -LA OR EQUAL.
EXPLOSION PROOF JUNCTION BOX
WITH COVER. O -Z /GEDNEY GUJC
0 0
Z
W
MOTOR
SPLICE
HANDHOLE PLAN
DETAIL
TYPE BOX EQUAL. SECURE
C
SPLICE HANDHOLE
ELEVATION
A
0
JUNCTION BOX TO UNISTRUT USING
O
0 p
- -i 1_
J
o6
NOT TO SCALE
1/4° STAINLESS STEEL BOLTS.I
LL.
NOT TO SCALE
0 0
-
Q
I
b
2" UNISTRUT. SECURE UNISTRUT
TO HANDHOLE WALLS.
0 "b
W
V
W
0 0
m
CADWELD TYPE TA. CADWELD
0 0
W
CABLE TO CABLE TEE
CADWELD TYPE RR. CADWELD
CONNECTION.
END CABLE TO UPPER REBAR
COPPER CONDUCTOR
`
- - - 0 0
- - - -
- -
CONNECTION.
0
REBAR
ELECTRICAL HANDHOLE,
UTILITY
#6 COPPER CONDUCTOR
VAULT MODEL 233 -LA
OR LIFTING INSERTS (TYPICAL).
EQUAL.
FLOAT /LEVEL TRANSMITTER
SPLICE
HANDHOLE PLAN
PROPOSED CONCRETE COVER,
GRADE
NOT TO SCALE
.
GROUND TEE DETAIL
GROUND REBAR
DETAIL
NOT TO SCALE
NOT TO SCALE
PROPOSED CONCRETE GROUND ROD
NATIVE MATERIAL COMPACTED TO 95%
RED ELECTRICAL WARNING TAPE
ENGINEERS
PLANNER S
PROTECTOR 13" DEPTH X 12" HEIGHT WITH
PER ASTM D1557 OR AS REQUIRED
CENTERED OVER EACH CONDUIT
RESTORE SURFACE TO EXISTING
SCIENTIST S
COVER. PIPE INC. #12R -12A & 12R -12T, OR
PER PLAN
IN TRENCH (TYP)
CONDITION OR BETTER PER PLANS
EQUAL.
RH2 ENGINEERING, INC.
CADWELD TYPE XA. CADWELD
http://www.rh2.com
mdb
aox0rh2com 1.800.720.8052
CADWELD TYPE OR
CABLE TO CABLE CROSS
CADWELD CABLE TO GROUND
CONNECTION.
"
cc,
°
x �'
w
BELLINGHAM aocl. a. sae
454 West Horton Road
# 6 COPPER CONDUCTOR
ROD CONNECTION.
5 8x8'
/
LONG COPPER GROUND ROD.
��°,
9
° °� °
,n
z
m o
BOTHELL "zsss,.saoo
22722 29th Drive SE, Suite 210
oz
6"
3
a
1.
EAST
WENATCHEE sos asa z000
COVER CONDUITE N HIGHEST
TRENCH /
O O
"
300 Simon Street, Swte 5
5/8" X 8' COPPER GROUND
ROD.
#6 COPPER CONDUCTOR
SAND BEDDING MATERIAL PER
RICHLAND soa.a"asta,
114 Columbia Point Drive, Suite C
(TYPICAL)
MINIMUM DEPTH BELOW BOTTOM
WSDOT SPECIFICATION 9 -03.13
OF DEEPEST CONDUIT
3"
SILVERDALE aso.s,.,aso
INSTALLED IN TRENCH
�,
ELECTRICAL CONDUIT NUMBER AND SIZE
2021 Hw Mnyre R4 Suite 107
-�
VARY AS PER SITE PLAN. MAINTAIN 12"
TACOMA ..zozaoss
GROUND TEE DETAIL
GROUND CROSS DETAIL
SPACING BETWEEN TELEMETRY CONDUITS
AND OTHER CONDUITS.
621 Pacific Avenue Suite 104
SCALE: SHOWN
NOT TO SCALE
NOT TO SCALE
v
TYPICAL ELECTRICAL TRENCH
DETAIL
0 1 2
NOT TO SCALE
DRAWING IS NOT TO SCALE
GROUND ROD
DETAIL
NOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING
SHALL BE RECORD DRAWING
IF BAR IS NOT 2" LONG
ow6 NO.
CONFIRMED WITH
SERVING UTILITY BEFORE CONSTRUCTION.
REVISED TO CONFORM
ROT. 1
owwma CCA
GROUNDING CONNECTION DETAILS
NOT TO SCALE
S=362814 TO CON TRUCTIO RECORDS
EOG
revewFU: MLM
ALM
NOT TO SCALE
04DATE72
Jul 2013
�¢T NO
w
a NT: REN75,
RH2 RING INC.
REVISED TO CONFORM TO CONSTRUCTION RECORDS AHF EH 04/25/13
17
JOB NI: 112 -033
nuNwe UBHS- D- E06.DWG
NO. I REVISION I BY REVIEW1 DATE